SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
1 Revision: S0
12/20/2007
www.deltaww.com
Intelligent SFP Bi-Directional Transceiver
Module for Gigabit Ethernet and Fast Ethernet
FEATURES
z RoHS compliant
z Digital Diagnostic SFF-8472 MSA compliant
z Simplex SC connector with 1550nm
Transmitter and 1310nm Receiver
z Single + 3.3V power supply and TTL logic
interface
z Bellcore GR-468 compliant
z Laser class 1 product which comply with the
requirements of IEC 60825-1 and IEC 60825-2
Description
The SPBD-1250xxxx series are hot pluggable
3.3V Small-Form-Factor (SFP) Bi-Directional
transceiver module designed expressly for
high-speed communication applications that
require rates of up to 1250Mbit/sec. It is compliant
with the Gigabit Ethernet and Fast Ethernet
standards, as well as the SFP Multisource
Agreement (MSA).
The SPBD-1250xxxx transceivers provide with
the SC receptacle that is compatible with the
industry standard SC connector. The transceiver is
also compatible with industry standard RFT
connector and cage. It also includes a LOS (Loss
Of Signal) circuit that provides a TTL logic-high
output when an unusable optical signal level is
detected.
The module includes 1550nm un-cool DFB
laser, InGaAs PIN, Preamplifer and WDM filter in a
high-integrated optical assembly for high-density
system application. The SFP Bi-Directional
transceiver can upgrade transmission capacity very
convenient without installing new fibers.
Application
z IEEE 802.3ah 1000BASE-BX
z Gigabit Ethernet
z FTTx WDM Broadband Access
z Switch to switch/backbone interface
Performance
z SPBD-1250F4Q2R data link up to 10km in
9/125um single mode fiber.
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
2 Revision: S0
12/20/2007
www.deltaww.com
1. Absolute Maximum Ratings
Parameter Symbol Min. Typ. Max. Unit Note
Storage Temperature Ts -40 85 ºC
Storage Ambient Humidity HA 5 95 %
Power Supply Voltage VCC 0 5 V
Signal Input Voltage -0.3 Vcc+0.3 V
Optical Input Power (Peak) +3 dBm
2. Recommended Operating Conditions
Parameter Symbol Min. Typ. Max. Unit Note
Operating Case Temperature TC -5 75 ºC Note (1)
Ambient Humidity HA 5 85 %
Non-condensing
Power Supply Voltage VCC 3.13 3.3 3.47 V
Power Supply Current ICC 300 mA
Power Supply Noise Rejection 100 mVp-p 100Hz to 1MHz
Data Rate 1250
-100ppm 1250 1250
+100ppm Mbps
Transmission Distance 10 km
Note (1). Measured on topside of case front center.
3. Specification of Transmitter
Parameter Symbol Min. Typ. Max. Unit Note
Average Launched Power PO -9 -6 -3 dBm Note (1)
Optical Extinction Ratio ER 9 dB
Center Wavelength C 1530 1550 1570 nm DFB Laser
Spectrum Width (-20dB) 0.88 nm
Side Mode Suppression Ratio SMSR 30 dB
Transmitter OFF Output Power POff -45
dBm
Optical Rise/Fall Time tr/tf 260 ps Note (2)
Deterministic Jitter DJ 80 ps
Total Jitter TJ 227 ps Note (3)
Relative Intensity Noise RIN12OMA -113 dB/Hz
Optical Return Loss Tolerance ORLT 12 dB
Transmitter Reflectance -10 dB
Output Eye Mask
{X1,X2,Y1,Y2,Y3}
Compliant with IEEE 802.3ah standard
{0.22,0.375,0.20,0.20,0.30} Note (4)
Note (1). Launched power (avg.) is power coupled into a single mode fiber.
Note (2). These are unfiltered 20-80% values.
Note (3). Measure at 27-1 NRZ PRBS pattern.
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
3 Revision: S0
12/20/2007
www.deltaww.com
Note (4). Eye Mask definition
4. Specification of Receiver
Parameter Symbol Min. Typ. Max. Unit Note
Input Optical Wavelength λIN 1260 1360 nm PIN-PD
Receiver Sensitivity PIN -23
dBm Note (1)
Input Saturation Power (Overload) PSAT -3 dBm
LOS-Deassert Power PA - -24 dBm
LOS-Assert Power PD -44 dBm Note (2)
LOS Hysteresis PA-PD 0.5 2 6 dB
Receiver Reflectance -12 dB Note (3)
Deterministic Jitter DJ 170 ps
Total Jitter TJ 266 ps
Output Data Rise/Fall time tr/tf 260 ps Note (4)
Note (1). Measured with 1310nm, ER=9dB; BER =<10-12@PRBS=27-1 NRZ
Note (2). When LOS asserted, the data output is Low-level (fixed)
Note (3). When the terminal is viewed from the optical path, the reflection toward the optical path of the
optical signal with a central wavelength of 1310nm transmitted to terminal.
Note (4). These are 20%~80% values
1
0
X1 X2 1-X2 1-X1
1+ Y 3
1
1- Y1
0.5
Y1
0
- Y2
N
ormalized Time
Normalized Amplitude
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
4 Revision: S0
12/20/2007
www.deltaww.com
5. Electrical Interface Characteristics
Parameter Symbol Min. Typ. Max. Unit Note
Transmitter
Total Supply Current ICC A mA Note (1)
Differential Data Input Swing VDT 500 2400 mVp-p
Differential line input Impedance RIN 80 100 120 Ohm
Transmitter Disable Input-High VDISH 2 VCC V Note (2)
Transmitter Disable Input-Low VDISL 0 0.8 V
Transmitter Fault Output-High VTXFH 2 VCC+0.3 V
Transmitter Fault Output-Low VTXFL 0 0.8 V
Transmitter Fault Pull up Resistor RTX_FAULT 4.7 10 k Note (3)
Receiver
Total Supply Current ICC B mA Note (1)
Differential Data Output Swing VDR 400 1200 mVp-p Note (4)
LOS Output Voltage-High VLOSH 2 VCC+0.3 V
LOS Output Voltage-Low VLOSL 0 0.8 V
Receiver LOS Load RRXLOS 4.7 10 k Note (3)
Note (1). A (TX)+ B (RX) = 300mA
(A: Not include termination circuit; B: using a resister of 150 between Data-output and ground)
Note (2). There is an internal 4.7 to 10k pull-up resistor to VccT.
Note (3). Pull up to VCC on host Board.
Note (4). Internally AC coupled output, but requires a 100Ohm differential termination at or internal to
Serializer/ Deserializer.
6. Digital Diagnostic Monitor Accuracy
Parameter Accuracy Unit Calibration Note
Transceiver Internal Temperature ± 3 Internal TC=-5~+75
Power Supply Internal Voltage ± 3% V Internal VCC=3.3V±5%
TX Bias Current ± 10% mA Internal Specified by nominal bias value
TX Optical Power ± 3dB dBm Internal -9 to -3dBm
RX Optical Power ± 3dB dBm Internal -23 to -3dBm
Note. Temperature and Voltage is measured internal to the transceiver.
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
5 Revision: S0
12/20/2007
www.deltaww.com
7. Pin Description
SFP Transceiver Electrical Pad Layout Host Board Connector Pad Layout
Pin Function Definitions
Pin Num. Name Function Plug Seq. Notes
1 VeeT Transmitter Ground 1 Note (1)
2 TX Fault Transmitter Fault Indication 3 Note (2)
3 TX Disable Transmitter Disable 3 Note (3)
4 MOD-DEF2 Module Definition 2 3 Note (4), 2 wire serial ID interface
5 MOD-DEF1 Module Definition 1 3 Note (4), 2 wire serial ID interface
6 MOD-DEF0 Module Definition 0 3 Note (4), Grounded in Module
7 Rate Select Not Connect 3 Function not available
8 LOS Loss of Signal 3 Note (5)
9 VeeR Receiver Ground 1
10 VeeR Receiver Ground 1
11 VeeR Receiver Ground 1
12 RD- Inv. Received Data Out 3 Note (6)
13 RD+ Received Data Out 3 Note (6)
14 VeeR Receiver Ground 1
15 VccR Receiver Power 2 Note (7)
16 VccT Transmitter Power 2 Note (7)
17 VeeT Transmitter Ground 1
18 TD+ Transmit Data In 3 Note (8)
19 TD- Inv. Transmit Data In 3 Note (8)
20 VeeT Transmitter Ground 1
Plug Seq.: Pin engagement sequence during hot plugging.
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
6 Revision: S0
12/20/2007
www.deltaww.com
Notes:
1) Circuit ground is internally isolated from frame (chassis) ground. Tx GND and Rx GND may be internally isolated
within the TRx module.
2) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K~10K resistor on the host board.
Pull up voltage between 2.0V and VccT+0.3V. The output indicates Low when the transmitter is operating
normally, and High with a laser fault including laser end-of-life. In the low state, the output will be pulled to less
than 0.8V.
3) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module
with a 4.7 – 10 K resistor. Its states are:
Low (0 – 0.8V): Transmitter on
(>0.8, < 2.0V): Undefined
High (2.0 – 3.465V): Transmitter Disabled
Open: Transmitter Disabled
4) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10Kresistor on the
host board. The pull-up voltage shall be VccT or VccR.
Mod-Def 0 is grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two-wire serial interface for serial ID
Mod-Def 2 is the data line of two-wire serial interface for serial ID
5) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10K resistor.
Pull up voltage between 2.0V and VccR+0.3V. When high, this output indicates the received optical power is
below the worst-case receiver sensitivity. Low indicates normal operation. In the low state, the output will be
pulled to less than 0.8V.
6) RD-/+: These are the differential receiver outputs. They are AC coupled 100 differential lines which should be
terminated with 100 (differential) at the user SERDES. The AC coupling is done inside the module and is thus
not required on the host board.
7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP
connector pin. Recommended host board power supply filtering is shown below page. Inductors with DC
resistance of less than 1 Ohm should be used in order to maintain the required voltage at the SFP input pin with
3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SFP
transceiver module will result in an inrush current of no more than 30 mA greater than the steady state value.
8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100
differential termination inside the module. The AC coupling is done inside the module and is thus not
required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 – 1200
mV single-ended), though it is recommended that values between 500 and 1200 mV differential (250 –
600 mV single-ended) be used for best EMI performance.
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
7 Revision: S0
12/20/2007
www.deltaww.com
8. Recommend Interface Circuit
Laser Diode
Photo Diode
1uH
1uH
0.1uF10uF
0.1uF
0.01uF
0.01uF
0.01uF
0.01uF
0.1uF10uF
RES1
RES1
100 Ohms*
RES1 RES1 RES1
10k Ohms
100 Ohms
VCC
Protocol Vcc
SerDes ICProtocol IC
PLD / PAL Mod_def 2
Mod_def 1
Mod_def 0
3.3V
3.3V
DELTA SFP Module
Preamp &
Tx_Disable
Quantizer
Tx_Fault
TD +
TD -
VeeT
RD +
RD -
Rx_LOS
VeeR
Tx_Disable
Tx_Fault
Rx_LOS
RES1 = 4.7k to 10k Ohms
VccT
VccR
Laser Driver
* Depands on SerDes IC used
EEPROM
SFP Host Board Schematic
Recommended Host Board Supply Filtering Network
Design criterion of the capacitor used is the
resonant frequency and its value must be in the
order of the nominal data rate. Short trace
lengths are mandatory.
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
8 Revision: S0
12/20/2007
www.deltaww.com
9. Outline Dimensions
Tx/Rx Wavelength Latch Color Identifier
1310nm/1550nm Black
1550nm/1310nm Yellow
1310nm/1490nm Blue
1490nm/1310nm Violet
Week (52Weeks/Year) : 1月2日=01
XXXXXXXXXXX
XXXXXXXXXXX
1040.10 and 1040.11
Made in x
Complies with 21 CFR
FS
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
9 Revision: S0
12/20/2007
www.deltaww.com
10. Enhanced Digital Diagnostic Interface
The memory map in the following describes an extension to the memory map defined in SFF-8472.
The enhanced interface uses the two wire serial bus address 1010001X(A2h) to provide diagnostic
information about the module’s present operating conditions.
2 wire address 1010000 X (A0h) 2 wire address 1010001 X (A2h)
0 0
55
Alarm and Warning Thresholds
(56 bytes)
95
Serial ID Defined by SFP MSA
(96 bytes) 56
95
Cal Constants
(40 bytes)
96 96
119
Real Time Diagnostic Interface
(24 bytes)
127
Vender Specific
(32 bytes) 120
127
Vender Specific
128 128
247
User Writable EEPROM
(120 bytes)
255
Reserved in SFP MSA
(128 bytes)
248
255
Vender Specific
(8 bytes)
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
10 Revision: S0
12/20/2007
www.deltaww.com
EEPROM Serial ID Memory Contents (2-Wire Address A0h)
Address Name of Field Value (Hex) Remark
Base ID Fields
00 Identifier 03 SFP transceiver
01 Ext. Identifier 04 Serial ID module supported
02 Connector 01 SC connector
03 00 Infiniband Compliance Codes
04-05 Transceiver code 00 00 Transceiver codes
06 Transceiver code 40 Ethernet Base-BX10 compliance
07-10 Transceiver code 00 00 00 00 Transceiver codes
11 Encoding 01 Compatible with 8B10B GE encoding code
12 BR, Nominal 0D Nominal 1300 Mbps (actual GE 1250Mbps)
13 Reserved 00 Reserved for SFF-8079
14 0A 9/125 ìm fiber, units of km (10km)
15 64 9/125 ìm fiber, units of 100 m (10000m)
16 00 50/125 ìm fiber, units of 10 m
17 00 62.5/125 ìm fiber, units of 10 m
18 00 Link length supported for copper, units of meters
19 00 Reserved
20 44 “D” (Vendor name in ASCII character)
21 45 “E” (Vendor name in ASCII character)
22 4C “L” (Vendor name in ASCII character)
23 54 “T” (Vendor name in ASCII character)
24 41 “A” (Vendor name in ASCII character)
25-35
Vendor Name
20 (Vendor name in ASCII character)
36 Channel spacing 00 Specify the channel spacing in units of GHz.
37-39 Vendor OUI 00 SFP vendor IEEE company ID
40 53 “S” (Vendor P/N in ASCII character)
41 50 “P” (Vendor P/N in ASCII character)
42 42 “B” (Vendor P/N in ASCII character)
43 44 “D” (Vendor P/N in ASCII character)
44 2D “-“ (Vendor P/N in ASCII character)
45 31 “1” (Vendor P/N in ASCII character)
46 32 “2” (Vendor P/N in ASCII character)
47 35 “5“ (Vendor P/N in ASCII character)
48 30 “0” (Vendor P/N in ASCII character)
49 46 “F” (Vendor P/N in ASCII character)
50 34 “4” (Vendor P/N in ASCII character)
51 51 “Q (Vendor P/N in ASCII character)
52 32 “2 (Vendor P/N in ASCII character)
53 52 “R” (Vendor P/N in ASCII character)
54 20 (Vendor P/N in ASCII character)
55
Vendor P/N
20 (Vendor P/N in ASCII character)
56-59 Vendor Rev 41 20 20 20 “A”
60-61 LD wavelength 06 0E (1550nm)
62 DWDM wavelength 00
63 CC_BASE XX Check sum (0~62)
Extended ID Fields
64 Reserved 00
65 Options 1A
(Tx_Diasble, Tx_Fault, LOS)
66 BR,max 00 Upper bit rate margin,units of %
67 BR,min 00 Lower bit rate margin,units of %
68-83 Vendor SN XX “DEYYWWVVRSSSSS”
84-91 Date code XX “YYMMDD”
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
11 Revision: S0
12/20/2007
www.deltaww.com
92 DDM 68 Diagnostics (Internally Calibrated)
93 Enhanced options B0 (Soft Tx_Fault, Soft LOS)
94 SFF-8472
compliance 01 SFF-8472 Compliance Rev.9.3
95 CC_EXT XX Check sum (64~94)
Vendor Specific ID Fields
96-127 Vendor Specific 00 Vendor Specific EEPROM
128-255 Reserved 00 Reserved for SFF-8079
Digital Diagnostic Monitoring Interface (2-Wire Address A2h)
Alarm and Warning Thresholds (2 Wire Address A2h)
Address # Bytes Name HEX Real Value Unit Note
00-01 2 Temp High Alarm 5A 00 90 ºC
02-03 2 Temp Low Alarm EC 00 -20 ºC
04-05 2 Temp High Warning 50 00 80 ºC
06-07 2 Temp Low Warning F6 00 -10 ºC
08-09 2 Voltage High Alarm 94 70 3.8 V
10-11 2 Voltage Low Alarm 6D 60 2.8 V
12-13 2 Voltage High Warning 87 8C 3.47 V
14-15 2 Voltage Low Warning
7A 44 3.13 V
16-17 2 Bias High Alarm 61 A0 50 mA
18-19 2 Bias Low Alarm 01 F4 1 mA
20-21 2 Bias High Warning 4E 20 40 mA
22-23 2 Bias Low Warning 01 F4 1 mA
24-25 2 TX Power High Alarm 27 10 0 dBm
26-27 2 TX Power Low Alarm 02 77 -12 dBm
28-29 2 TX Power High Warning 13 94 -3 dBm
30-31 2 TX Power Low Warning 04 EB -9 dBm
32-33 2 RX Power High Alarm 27 10 0 dBm
34-35 2 RX Power Low Alarm 0019 -26 dBm
36-37 2 RX Power High Warning 13 94 -3 dBm
38-39 2 RX Power Low Warning 00 32 -23 dBm
40-55 16 Reserved
Notes:
1) TC: Operating Case temperature
2) Ibias: Bias current at room temperature. The min. setting current is 0 mA.
3) PO: Operating optical power of transmitter at room temperature.
4) PSAT: Overload optical power of receiver
5) PIN: Sensitivity optical power of receiver
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
12 Revision: S0
12/20/2007
www.deltaww.com
Calibration Constants (2 Wire Address A2h)
Address # Bytes Name HEX Description
56-59 4 Rx_PWR (4) 00 00 00 00 Rx_PWR (4) is set to zero for “internally calibrated” devices.
60-63 4 Rx_PWR (3) 00 00 00 00 Rx_PWR (3) is set to zero for “internally calibrated” devices.
64-67 4 Rx_PWR (2) 00 00 00 00 Rx_PWR (2) is set to zero for “internally calibrated” devices.
68-71 4 Rx_PWR (1) 3F 80 00 00 Rx_PWR (1) is set to 1 for “internally calibrated” devices.
72-75 4 Rx_PWR (0) 00 00 00 00 Rx_PWR (0) is set to zero for “internally calibrated” devices.
76-77 2 Tx_I (Slope) 01 00 Tx_I (Slope) is set to 1 for “internally calibrated” devices.
78-79 2 Tx_I (Offset) 00 00 Tx_I (Offset) is set to zero for “internally calibrated” devices.
80-81 2
Tx_PWR (Slope) 01 00 Tx_PWR (Slope) is set to 1 for “internally calibrated”
devices.
82-83 2
Tx_PWR
(Offset) 00 00 Tx_PWR (Offset) is set to zero for “internally calibrated”
devices.
84-85 2 T (Slope) 01 00 T (Slope) is set to 1 for “internally calibrated” devices.
86-87 2 T (Offset) 00 00 T (Offset) is set to zero for “internally calibrated” devices.
88-89 2 V (Slope) 01 00 V (Slope) is set to 1 for “internally calibrated” devices.
90-91 2 V (Offset) 00 00 V (Offset) is set to zero for “internally calibrated” devices.
92-94 3 Reserved 00 00 00 Reserved
95 1 Checksum XX
Byte 95 contains the low order 8 bits of the sum of bytes 0 –
94.
A/D Value (2 Wire Address A2h)
Address # Bytes Name Description
96-97 2 Temperature (MSB, LSB) Internally measured module temperature
98-99 2 Supply Voltage (MSB, LSB) Internally measured supply voltage in module
100-101 2 Tx Bias Current (MSB, LSB) Internally measured Tx Bias current
102-103 2 Tx Optical Power (MSB, LSB) Measured Tx output power
104-105 2 Rx Received Power (MSB, LSB) Measured Rx input power
106-109 4 Reserved
Notes:Temperature (Signed twos complement value)
A2h Byte 96 (Temperature MSB) A2h Byte 97 (Temperature LSB)
S 26 25 24 23 22 21 20 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8
Supply Voltage, Tx Bias Current, Tx Optical Power, Rx Received Power (Unsigned values)
A2h Byte 98 (Vcc MSB) A2h Byte 99 (Vcc LSB)
A2h Byte 100 (TX Bias MSB) A2h Byte 101 (TX Bias LSB)
A2h Byte 102 (TX Power MSB) A2h Byte 103 (TX Power LSB)
A2h Byte 104 (RX Power MSB) A2h Byte 105 (RX Power LSB)
215 2
14 213 212 211 210 29 28 27 26 25 24 23 22 21 20
The digital value conversions are updated every 13ms (nominal) or 20ms (max) in rotation. After getting digital value,
each measurement could be obtained by multiplying digital value by corresponding LSB value:
Temperature = Temp (Digital Value) × LSBTe m p = Temp (Digital Value) × 1
256; when Temperature<128
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
13 Revision: S0
12/20/2007
www.deltaww.com
Temperature = Temp (Digital Value) × LSBTe m p = [Temp (Digital Value) × 1
256]-256; when Temperature128
Vcc = Vcc(Digital Value) × LSBVcc=VCC(Digital Value) × 100µV
TX Bias Current = TX Bias Current (Digital Value) × LSBTX,Bias = TX Bias Current (Digital Value) × 2µA
TX Power = TX Power (Digital Value) × LSBTXPower = TX Power (Digital Value) × 0.1µW
RX Power = RX Power (Digital Value) × LSBRXPower = RX Power (Digital Value) × 0.1µW
Optional Status/Control Bits (2 Wire Address A2h)
Address Bit Name Description
110 7 TX Disable State Not implement.
110 6 Soft TX Disable Not implement.
110 5 Reserved
110 4 RX Rate Select State Not implement.
110 3 Soft RX Rate Select Not implement.
110 2 TX Fault State Digital state of the TX Fault Output Pin.
110 1 LOS Digital state of the LOS Output Pin.
110 0 Data_Ready_Bar Indicates transceiver has achieved power up and data is
ready.
111 All Reserved Reserved for SFF-8079
Alarm/Warning Flag Bits (2 Wire Address A2h)
Address Bit Name Description
112 7 Temp High Alarm Set when internal temperature exceeds high alarm level.
112 6 Temp Low Alarm Set when internal temperature is below low alarm level.
112 5 Vcc High Alarm Set when internal supply voltage exceeds high alarm level.
112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level.
112 3 TX Bias High Alarm Set when TX Bias current exceeds high alarm level.
112 2 TX Bias Low Alarm Set when TX Bias current is below low alarm level.
112 1 TX Power High Alarm Set when TX output power exceeds high alarm level.
112 0 TX Power Low Alarm Set when TX output power is below low alarm level.
113 7 RX Power High Alarm Set when Received Power exceeds high alarm level.
113 6 RX Power Low Alarm Set when Received Power is below low alarm level.
113 5-0 Reserved Alarm
114-115 All Reserved
116 7 Temp High Warning Set when internal temperature exceeds high warning level.
116 6 Temp Low Warning Set when internal temperature is below low warning level.
116 5 Vcc High Warning Set when internal supply voltage exceeds high warning level.
116 4 Vcc Low Warning Set when internal supply voltage is below low warning level.
116 3 TX Bias High Warning Set when TX Bias current exceeds high warning level.
116 2 TX Bias Low Warning Set when TX Bias current is below low warning level.
116 1 TX Power High Warning Set when TX output power exceeds high warning level.
116 0 TX Power Low Warning Set when TX output power is below low warning level.
117 7 RX Power High Warning Set when Received Power exceeds high warning level.
117 6 RX Power Low Warning Set when Received Power is below low warning level.
117 5-0 Reserved Warning
118-119 All Reserved
SPBD-1250F4Q2R
DELTA ELECTRONICS, INC.
14 Revision: S0
12/20/2007
www.deltaww.com
Vendor Specific and User Accessible EEPROM (2 Wire Address A2h)
Address # Bytes Name Description
120-122 3 Reserved
123 1 Password Byte 3 High order byte of 32 bit password
124 1 Password Byte 2 Second highest order byte of 32 bit password
125 1 Password Byte 1 Second lowest order byte of 32 bit password
126 1 Password Byte 0 Low order byte of 32 bit password
127 1 User EEPROM Select “1” selects user writable EEPROM at locations 128-247
128-247 120 User EEPROM User writable EEPROM
248-255 8 Vendor Specific Vendor specific control functions
11. Regulatory Compliance
Feature Test Method Reference Performance
Human Body Model
(HBM)
MIL-STD-883E Method 3015.7
EIA-JESD22-A114
Electrostatic Discharge
(ESD) to the Electrical
Pins Machine Model (MM) EIA-JESD22-A115
Contact Discharge IEC/EN 61000-4-2 Electrostatic Discharge
(ESD) to the Simplex
Receptacle Air Discharge IEC/EN 61000-4-2
Radio Frequency
Electromagnetic Field
Immunity
IEC/EN 61000-4-3
Electromagnetic
Interference (EMI)
FCC Part 15 Class B
EN 55022 Class B
(CISPR 22A)
(1) Satisfied with
electrical
characteristics of
product spec.
(2) No physical damage
Laser Eye Safety
FDA/CDRH
TUV
FDA 21CFR 1040.10, 1040.11
IEC/EN 60825-1
IEC/EN 60825-2
CDRH File # 0420993
TUV Certificate #
R50032471
Component Recognition
TUV
UL/CSA
IEC/EN 60950
UL 60950
UL File # E239394
Appendix A. Document Revision
Version No. Date Description
S0 2007-12-20 Preliminary datasheet