PHOENIX CONTACT GmbH & Co. KG Page 1 / 5
http://www.phoenixcontact.com Jul 12, 2009
Extract from the online
catalog
CTNC-UFB-5DC/E
Order No.: 2762087
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2762087
CTNC-UFB-5DC/E Order No.: 2762087
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2762087
PHOENIX CONTACT GmbH & Co. KG Page 2 / 5
http://www.phoenixcontact.com Jul 12, 2009
Attachment plug with surge voltage coarse and fine protection, for
coaxial signal interfaces with floating shield, signal voltage 5 V.
Connection: TNC female/male connector
Commercial data
EAN 4017918064839
Pack 10 pcs.
Customs tariff 85363010
Weight/Piece 0.11418 KG
Catalog page information Page 117 (TT-2002)
Product notes
WEEE/RoHS-compliant since:
06/16/2006
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
General
Housing material Aluminum
Color black
Ambient temperature (operation) -40 °C ... 80 °C
Mounting type Connection-specific intermediate plugging
Design Attachment plug
Degree of protection IP20
Direction of action Line-Shield/Earth Ground
Width 25.40 mm
Height 93.00 mm
Length 25.40 mm
Protective circuit
IEC category C2
C3
CTNC-UFB-5DC/E Order No.: 2762087
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2762087
PHOENIX CONTACT GmbH & Co. KG Page 3 / 5
http://www.phoenixcontact.com Jul 12, 2009
VDE requirement class C2
C3
Nominal voltage UN5 V DC
Arrester rated voltage UC (Core-Earth) 5 V DC
Nominal current IN185 mA (25°C)
Operating effective current IC at UC≤ 300 µA
Nominal discharge surge current In (8/20) µs
(Core-GND)
10 kA
Output voltage limitation at 1 kV/µs (Core-Core)
spike
≤ 13 V
Output voltage limitation at 1 kV/µs (Core-Earth)
spike
≤ 500 V
Output voltage limitation at 1 kV/µs (Core-Earth)
static
≤ 500 V
Output voltage limitation at 1 kV/µs (Core-GND)
static
≤ 13 V
Residual voltage at In, (conductor-GND) ≤ 10 V
Protection level UP (Core-Earth) ≤ 500 V
Protection level UP (Core-GND) ≤ 13 V
Response time tA (Core-Earth) ≤ 500 ns
≤ 100 ns
Cut-off frequency fg (3 dB), asym. (PE) in 50 Ohm
system
170 MHz
Resistance in series 22 Ω
Connection data
Type of connection TNC 50 Ω
Connection type IN TNC socket
Connection type OUT TNC plug
Connection, protective circuit
Standards/regulations Draft IEC 64644-1
E VDE 0845-3-1
CTNC-UFB-5DC/E Order No.: 2762087
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2762087
PHOENIX CONTACT GmbH & Co. KG Page 4 / 5
http://www.phoenixcontact.com Jul 12, 2009
Drawings
Diagram
Dimensioned drawing
Circuit diagram
CTNC-UFB-5DC/E Order No.: 2762087
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2762087
PHOENIX CONTACT GmbH & Co. KG Page 5 / 5
http://www.phoenixcontact.com Jul 12, 2009
Address
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 00
Fax +49 5235 3 41200
http://www.phoenixcontact.com
© 2009 Phoenix Contact
Technical modifications reserved;