02/11/2015 www.crouzet.com 35 mm - 2 Relays 8A PU2R1 Part number 88867305 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external power supply to the control input 3-wire sensor control option Part numbers Type 88 867 305 Functions PU2R1 A - At - B - C - H - Ht - Di - D - Ac - Bw Timing Output Nominal rating Connections Supply voltage 0,1s100h 2 timed changeover relays 8A 11-pin 24 V DC / 24 240 V AC Specifications Timing Timing ranges (7 ranges) Repetition accuracy with constant parameters Drift Temperature Drift Voltage Display accuracy according to IEC/EN 61812-1 Minimum pulse duration typically (relay version) Minimum pulse duration typically (solid state version) Minimum pulse duration typically (relay version under load) Maximum reset time by de-energisation typically (relay version) Maximum reset time by de-energisation typically (solid state version) Immunity from micro power cuts : typical Supply Multi-voltage power supply Frequency (Hz) Operating range Operating factor Max. absorbed power 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h TK2R1 : 0.6s - 2.5s - 20s - 160 s 0.5 % (IEC/EN 1812-1) 0,05 % / C 0.2 % / V 10 % / 25 C 30 ms 50 ms 100 ms 100 ms 350 ms > 10 ms Depending on version 50 / 60 85 to 110 % Un (85 to 120 % Un for 12V AC/DC) 100 % 0,6 W 24 V AC/DC 1,5 W 230 V AC 32 VA 230 V AC Output specification 1 or 2 changeover relays, AgNi (cadmium-free) Rated power Maximum breaking current Minimum breaking current Voltage breaking capacity Electrical life (operations) 2000 VA/80 W 2000 VA/80 W 8 A AC 8A DC 10 mA / 5 V DC 250 V AC/ DC Mechanical life (operations) 5x106 2.5 kV /1 min / 1 mA / 50 Hz 5 kV, wave 1.2 / 50 s Breakdown voltage acc. to IEC/EN 61812-1 Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1 10 5 operations 8 A 250 V resistive Solid state output Rated power Derating Maximum admissible current Minimum breaking current Leakage current Voltage breaking capacity Maximum voltage drop at terminals Electrical life (operations) Mechanical life (operations) Breakdown voltage acc. to IEC/EN 60664-1, IEC/EN 60255-5 Input type 0,7 A AC/DC 20 C (0,5 A UL) 5 mA / C 20 A 10 ms 10 mA < 5 mA 250 V AC/ DC 3 wire 4V - 2 wire 8V 108 108 2.5 kV to 1 mA / 1 min Volt-free contact 3-wire PNP output control option residual voltage : 0.4V whatever the timer power supply General characteristics Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 Conformity to standards www.crouzet.com IEC/EN 61812-1 IEC/EN 61000-6-1 IEC/EN 61000-6-2 IEC/EN 61000-6-3 IEC/EN 61000-6-4 CE, UL, cUL, CSA, GL -20 +60 -30 +60 Certifications Temperature limits use (C) Temperature limits stored (C) Installation category Voltage surge category (acc. to IEC/EN 60664-1) Creepage distance and clearance acc. to IEC/EN 60664-1 4 kV / 3 Protection (IEC/EN 60529) IP 20 IP 40 Degree of protection acc. to IEC/EN 60529 Front face IP 50 (except Tk2R1) Vibration resistance f = 10 55 Hz acc. to IEC/EN 60068-2-6 A = 0,35 mm Relative humidity no condensation acc. to IEC/EN 6006893 % sans condensation 2-30 Electromagnetic compatibility - Immunity to electrostatic Level III (Air 8 KV / Contact 6 KV) discharges acc to IEC/EN 61000-4-2 Immunity to radiated, radio-frequency, electromagnetic Level III 10V/m (80 M Hz to 1 G Hz) field acc. IEC/EN 61000-4-3 Immunity to rapid transient bursts acc. to IEC/EN 61000-4Level III (direct 2kV / Capacitive coupling clamp 1 KV) 4 Immunity to shock waves on power supply acc. to IEC/EN Level III (2 KV / common mode 2 KV/residual current mode 1KV) 61000-4-5 Immunity to radio frequency in common mode acc. to Level III (10V rms : 0.15 M Hz to 80 M Hz) IEC/EN 61000-4-6 Immunity to voltage dips and breaks acc. to IEC/EN 61000- 30 %/10 ms 4-11 60 %/100 ms > 95 %/5 s Mains-borne and radiated emissions acc. to EN 55022 Class B (CISPR22), EN55011 (CISPR11) Fixing : Symmetrical DIN rail 35 mm Connection capacity - without ferrule 2 x 2,5 mm2 Connection capacity - with ferrule 2 x 1,5 mm2 Spring terminals, 2 terminals per connection point flexible wire Spring terminals, 2 terminals per connection point - rigid wire Housing material Weight : casing 17,5 mm Weight : casing 22,5 mm Weight : plug-in casing 1,5 mm2 2,5 mm2 Self-extinguishing 60 g 90 g 80 g Accessories Accessories Code 11-pin connector base 25622080 Display State displayed by 1 LED - Flashing green when on Green LED operation indicator Pulsing : - timer on, no timing in progress (except functions Di-D and Li-L) Flashing : - timing in progress Permanently lit : - Relay waiting, no timing in progress Dimensions (mm) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 Dimensions (mm) Accessories Curves Function A Function A Delay on energisation 2 timers or 2 relays, including 1 instantaneous Curves Function Ac Function Ac Temporisation combinee fermeture / ouverture 2 relais temporises ou 2 relais dont 1 instantane Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 Curves Function At 2 relays Function At Timing on energisation with memory 2 timers or 2 relays, including 1 instantaneous Curves Function B Function B Timing on impulse one shot 2 timers or 2 relays, including 1 instantaneous Curves Function Bw Function Bw Pulse output (adjustable) 2 timers or 2 relays, including 1 instantaneous Curves Function C Function C Timing after impulse 2 timers or 2 relays, including 1 instantaneous Curves Function D Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 Function D Flip-flop Pause start 2 timers or 2 relays, including 1 instantaneous Curves Function Di Flip-flop Pause start 2 timers or 2 relays, including 1 instantaneous Curves Function H Function H Timing on energisation 2 timers or 2 relays, including 1 instantaneous Curves Function Ht Function Ht Delay on energisation with memory 2 timers or 2 relays, including 1 instantaneous Connections 11-pin 2 relay outputs Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 02/11/2015 Functions Functions A - At / H - Ht / B / C / Di - D / Ac / Bw Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com