LITE-ON DCC
RELEASE
LITE-ON Technology Corp. / Optoelectronics
No.90,Chien 1 Road, Chung Ho, New Taipei City 23585, Taiwan, R.O.C.
Tel: 886-2-2222-6181 Fax: 886-2-2221-1948 / 886-2-2221-0660
http://www.liteon.com/opto
Through Hole Lamp
Product Data Sheet
LTL-4238
Spec No.: DS-20-92-0001
Effective Date: 04/14/2000
Revision: -
BNS-OD-FC001/A4
BNS-OD-FC001/A4
BNS-OD-FC001/A4
BNS-OD-FC001/A4
Features
* High Intensity.
* Popular T-1 3/4 diameter Package.
* Selected minimun intensities.
* General purpose leads.
* Reliable and rugged.
Package Dimensions
Part No.
Lens
Source Color
LTL-4238
Water Clear
Green
Notes:
1. All dimensions are in millimeters (inches).
2. Tolerance is ±0.25mm(.010") unless otherwise noted.
3. Protruded resin under flange is 1.0mm(.04") max.
4. Lead spacing is measured where the leads emerge from the package.
5. Specifications are subject to change without notice.
Part No. : LTL-4238
Page : 1 of 4
BNS-OD-C131/A4
Absolute Maximum Ratings at TA=25
Parameter
Maximum Rating
Unit
Power Dissipation
100
mW
Peak Forward Current
(1/10 Duty Cycle, 0.1ms Pulse Width)
120
mA
Continuous Forward Current
30
mA
Derating Linear From 50
0.4
mA/
Reverse Voltage
5
V
Operating Temperature Range
-55 to + 100
Storage Temperature Range
-55 to + 100
Lead Soldering Temperature
[1.6mm(.063") From Body]
260 for 5 Seconds
Part No. : LTL-4238
Page : 2 of 4
BNS-OD-C131/A4
Electrical / Optical Characteristics at TA=25
Parameter
Symbol
Min.
Typ.
Max.
Unit
Test Condition
Luminous Intensity
IV
29
90
mcd
IF = 10mA
Note 1,4
Viewing Angle
2θ1/2
16
deg
Note 2 (Fig.6)
Peak Emission Wavelength
λP
565
nm
Measurement
@Peak (Fig.1)
Dominant Wavelength
λd
569
nm
Note 3
Spectral Line Half-Width
Δλ
30
nm
Forward Voltage
VF
2.1
2.6
V
IF = 20mA
Reverse Current
IR
100
μA
VR = 5V
Capacitance
C
35
pF
VF = 0 , f = 1MHz
Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
(Commission International De L'Eclairage) eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
4. The Iv guarantee should be added ±15%.
Part No. : LTL-4238
Page : 3 of 4
BNS-OD-C131/A4
Typical Electrical / Optical Characteristics Curves
(25 Ambient Temperature Unless Otherwise Noted)
Part No. : LTL-4238
Page : 4 of 4
BNS-OD-C131/A4