https://www.phoenixcontact.com/us/products/2313559
09/03/2014Page1/5
Interface converters-FL COMSERVER WLAN 232/422/485-2313559
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
FL COMSERVER WLAN..., to convert a serial RS-232/422/485 or USB interface to 54 Mbps WLAN Ethernet,
supports TCP, UDP applications, incl. CD-ROM with Com Port Redirector Software and user documentation
(PDF).
Product Features
Redundant power supply and modular station structure with TBUS connectors
User-friendly configuration software
Ad-hoc or infrastructure mode
LED diagnostic indicators
Software for virtual COM ports supplied as standard
3-way electrical isolation VCC // RS-232/RS-422/RS-485 // network
Extended temperature range of -25°C to +60°C
Key commercial data
Packing unit 1 pc
Weight per Piece (excluding packing) 220.0 GRM
Custom tariff number 85176200
Country of origin Germany
Technical data
Dimensions
Width 22.5 mm
Height 99 mm
Depth 121 mm
Ambient conditions
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
https://www.phoenixcontact.com/us/products/2313559
09/03/2014Page2/5
Interface converters-FL COMSERVER WLAN 232/422/485-2313559
Technical data
Ambient conditions
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Altitude 5000 m (For restrictions see manufacturer's declaration)
Degree of protection IP20
Noise immunity EN 61000-6-2:2005
General
Electrical isolation VCC // WLAN, RS-232, RS-422, RS-485, USB
Test voltage data interface/data interface 1.5 kVrms (50 Hz, 1 min.)
Test voltage data interface/power supply 1.5 kVrms
1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Noise emission EN 61000-6-4
Net weight 190 g
Housing material PA 6.6-FR
Color green
MTBF 1153 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5
days a week, 8 hours a day))
262 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle
(5 days a week, 12 hours a day))
MTTF 2120 Years (SN 29500 standard, temperature 25°C, operating cycle 21 %
(5 days a week, 8 hours a day))
851 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25
% (5 days a week, 12 hours a day))
346 Years (SN 29500 standard, temperature 40°C, operating cycle 100 %
(7 days a week, 24 hours a day))
Conformance CE-compliant
UL, USA / Canada 508 listed
FCC Part 15, RSS 210
Power supply
Nominal supply voltage 24 V DC ±20 % (as an alternative or redundant, via backplane bus contact
and system current supply)
Supply voltage range 10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
19 V AC ... 29 V AC
Typical current consumption ≤ 100 mA (24 V DC)
Serial interface
Interface 1 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Interface V.24 (RS-232)
Connection method D-SUB-9 plug
https://www.phoenixcontact.com/us/products/2313559
09/03/2014Page3/5
Interface converters-FL COMSERVER WLAN 232/422/485-2313559
Technical data
Serial interface
File format/coding Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit
character length
Data flow control/protocols Software handshake, Xon/Xoff or hardware handshake RTS/CTS
Serial transmission speed 0.3; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 31.25; 38.4; 57.6; 75; 93.75; 115.2 kbps
Interface 2 RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Interface RS-422
Connection method Plug-in/screw connection via COMBICON
File format/coding Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit
character length
Transmission length ≤ 1200 m
Termination resistor 390 Ω
180 Ω
390 Ω (Can be connected)
Data flow control/protocols Automatic control
Serial transmission speed 0.3; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 31.25; 38.4; 57.6; 75; 93.75; 115.2; 136;
187.5 kbps
Interface 3 RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
Interface RS-485
Connection method Plug-in/screw connection via COMBICON
File format/coding Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit
character length
Termination resistor 390 Ω
180 Ω
390 Ω (Can be connected)
Data flow control/protocols Automatic control
Serial transmission speed 0.3; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 31.25; 38.4; 57.6; 75; 93.75; 115.2; 136;
187.5 kbps
Interface 4 USB interface
Interface USB
Connection method Mini-USB B, socket
Radio interface
Interface description WLAN as per IEEE 802.11 b/g
Frequency range 2.402 GHz ... 2.48 GHz (ISM bandwidth)
Transmit capacity, minimum -28 dBm (Can be set via software)
Transmit capacity, maximum 20 dBm (Can be set via software)
Data rate ≤ 54 Mbps
Minimum receiver sensitivity -85 dBm
Antenna External
https://www.phoenixcontact.com/us/products/2313559
09/03/2014Page4/5
Interface converters-FL COMSERVER WLAN 232/422/485-2313559
Technical data
Radio interface
Connection method SMA socket
Operating mode Infrastructure mode, ad-hoc mode
Security 802.11i, WPA PSK (preshared key), WPA2 PSK, AES, WEP 64 Bit/128 Bit,
TKIP
Configuration USB, serially with configuration software
Protocols supported TCP/IP, UDP
Function
Management With configuration software via USB and serial interface
Status and diagnostic indicators LEDs: UL (logic voltage), TD + RD (data activity serial), 4-level bar graph
(received wireless power), SER ERR (serial errors)
Classifications
eCl@ss
eCl@ss 4.0 27230207
eCl@ss 4.1 27230207
eCl@ss 5.0 27230207
eCl@ss 5.1 27230207
eCl@ss 6.0 27230207
eCl@ss 7.0 27230207
eCl@ss 8.0 27230207
ETIM
ETIM 2.0 EC000739
ETIM 3.0 EC000310
ETIM 4.0 EC000310
ETIM 5.0 EC000310
UNSPSC
UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 39121008
Approvals
Approvals
https://www.phoenixcontact.com/us/products/2313559
09/03/2014Page5/5
Interface converters-FL COMSERVER WLAN 232/422/485-2313559
Approvals
Approvals
UL Listed / cUL Listed / UL Listed / cUL Listed / cULus Listed
Ex Approvals
Approvals submitted
Approval details
UL Listed
cUL Listed
UL Listed
cUL Listed
cULus Listed
Phoenix Contact 2014 © - all rights reserved
http://www.phoenixcontact.com