DRA4 CMX Series
• 54mm 4 Channel DIN Rail Mount SSR Assembly
• DC Ratings up to 200 VDC and 8 Amps
• 3-10 and 20-28VDC control
• Cage style screw terminals for easy connection
• Fits standard 35mm DIN rail
• Includes LED Status indicator
PRODUCT SELECTION
Description 3 A 8 A (3)
3-10 VDC Control DRA4-CMX200D3 DRA4-CMX100D10
20-28 VDC Control DRA4-CMXE200D3 DRA4-CMXE100D10
OUTPUT SPECIFICATIONS (1)
Description 3 A 8 A (3)
Operating Voltage [VDC] 1-200 1-100
Maximum Off-State Leakage Current @ Rated Voltage [µAdc] 100 100
Maximum Load Current [A] (2) (3) 3 8
Minimum Load Current [A] 0 0
Maximum On-State Resistence [Ohm] 0.2 0.01
Maximum Surge Current (10msec) [Apk] 30 100
Maximum On-State Voltage Drop @ Rated Current [VDC] 0.6 0.1
INPUT SPECIFICATIONS (1)
Description DRA4-CMX DRA4-CMXE
Control Voltage Range 3.0-10.0 VDC 20.0-2 8.0 VDC
Must Turn On Voltage 3.0 VDC 20.0 VDC
Must Turn Off Voltage 1 .0 VDC 1 .0 VDC
Typycal Input Current 15 mAdc @ 5Vdc 12 mAdc @ 20 Vdc
Nominal Input Impedance 300 Ohm 780 Ohm
Maximum Turn-On Time [msec] 1 1
Maximum Turn-Off Time [µsec] 300 300
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength (4) 2500 Vrms
Minimum Insulation Resistance (@ 500 VDC)(4) 109 Ohms
Maximum Capacitance, Input/Output 15 pF
Ambient Operating Temperature Range -30 to 80°C
Ambient Storage Temperature Range -30 to 125°C
Weight (typical) 0.23 oz. (104.6g)
Encapsulation Thermally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See derating chart on page 3.
3) Steady state load Current exceeding 8 amps will damage socket.
4).Dielectric and insulation resistance is measured between input and output.
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116950 3 and 10A CMX relays only
Rv. 110811
ANNEX - ENVIROMENTAL INFORMATION