NTC thermistors for inrush current limiting
Inrush Current Limiters (ICLs)
Series/Type: P27
Ordering code: B57127P0xxxM301
Date: 2015-06-22
Version: P2
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Content of header bars 1 and 2 of data sheet will be
automatically
entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
(header 1 + top left bar): NTC thermistors for inrush current limiting
Identification/Classification 2
(header 2 + bottom left header bar): Inrush Current Limiters (ICLs)
Ordering code: (top right header bar) B57127P0xxxM301
Series/Type: (bottom right header bar) P27
Preliminary data (optional): Preliminary data
Department: PPD VAR PD
Date: 2015-06-22
Version: P2
NTC thermistors for inrush current limiting B57127P0xxxM301
Inrush Current Limiters (ICLs) P27
Preliminary data
PPD VAR PD 2015-06-22
Please read Cautions and warnings and Page 2 of 5
Important notes at the end of this document.
Application
Switch-mode power supplies
Soft-start motors, e.g. in vacuum cleaners
Features
Black coated thermistor disk
Coating material is flame retardant (UL 94 V-0 approved)
Kinked leads of tinned copper wire
Lead spacing 7.5 mm
High stability of electrical characteristic
Terminals solderable in accordance with IEC 60068-2-20, test ta, method 1
ICL support to fulfill the requirements according EN 61000 of power circuits
UL approval (E69802)
RoHS-compatible
NTC thermistors for inrush current limiting B57127P0xxxM301
Inrush Current Limiters (ICLs) P27
Preliminary data
PPD VAR PD 2015-06-22
Please read Cautions and warnings and Page 3 of 5
Important notes at the end of this document.
Drawing
1) seating plane in accordance with IEC 60717
Approx. weight: 10 g
General technical data
Climatic category (IEC 60068-1) 55/170/21
Max. power (at 25 °C) Pmax 12 W
Resistance tolerance RR/RR ± 20 %
Rated temperature TR 25 °C
Dissipation factor (in air) δ
th
approx. 50 mW/K
Thermal cooling time constant (in air) τ
th
approx. 200 s
Heat capacity C
th
approx. 10000 mJ/K
Electrical specification and ordering codes
R
25
I
C
test
C
test
C
test
Max R
min
Ordering
(0...25 °C)
at 280Vac
at 240 Vac at 120 Vac Energy
(at I
, 25 °C)
Code
A µF µF µF J
0.5 30 1300 3500 16000 200 0.011 B57127P0508M301
1 30 1300 3500 16000 200 0.013 B57127P0109M301
2 23 1300 3500 16000 200 0.022 B57127P0209M301
5 20 1300 3500 16000 200 0.033 B57127P0509M301
7 17 1300 3500 16000 200 0.045 B57127P0709M301
10 15 1300 3500 16000 200 0.053 B57127P0100M301
b 31.0max mm
th 7.0 max mm
h 39.0 max mm
LL 25.0 min mm
LD 1.0 ± 0.05 mm
LS 7.5 ± 0.8 mm
NTC thermistors for inrush current limiting B57127P0xxxM301
Inrush Current Limiters (ICLs) P27
Preliminary data
PPD VAR PD 2015-06-22
Please read Cautions and warnings and Page 4 of 5
Important notes at the end of this document.
Internal construction
The above picture shows the internal construction of EPCOS ICLs.
Note: Coating may have cracks or chips due to acting mechanical force on the wire, but this does not affect the
performance of the component.
Coating
Ceramic
Metallization Solder joint
Important notes
Page 5 of 5
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed
questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, Alu-X, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CSSP, CTVS,
DeltaCap, DigiSiMic, DSSP, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD,
MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PQSine, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries.
Further information will be found on the Internet at www.epcos.com/trademarks.