Input
Output
Characteristic Minimum Typical Maximum Units Notes & Conditions
Output Voltage 3.3 24 VDC See Models and Ratings table
Initial Set Accuracy -7.5, +2.5 % At 70% load
Minimum Load 10 %
Line Regulation ±1.2 % Per 1% change of input voltage (±1.5% for 3V3 output)
Load Regulation % See graph
Start Up Delay 2 ms
Ripple and Noise 100 mV pk-pk 20 MHz bandwidth, measured using 0.1 µF capacitor
Transient Response 3 % deviation Recovery to within 1% in 500 µs for a 25% load change (5%
max. deviation for 3.3 & 5 V models)
Short Circuit Protection Continuous, with auto recovery, except 1 s max for
24 input V models
Maximum Capacitive Load 220 µF
Temperature Coefficient 0.03 %/˚C
Characteristic Minimum Typical Maximum Units Notes & Conditions
Input Voltage Range
4.50 5.50 VDC 5 V nominal
10.80 13.20 VDC 12 V nominal
13.50 16.50 VDC 15 V nominal
21.60 26.40 VDC 24 V nominal
Input Current See Models and Ratings table
Input Reflected Ripple 15 mA pk-pk Through 12 µH inductor and 47 µF capacitor
Input Surge
9VDC for 1 s 5 V models
18 VDC for 1 s 12 V models
21 VDC for 1 s 15 V models
30 VDC for 1 s 24 V models
Input Filter Capacitor
General
Characteristic Minimum Typical Maximum Units Notes & Conditions
Efficiency See Models and Ratings table
Isolation: Input to Output 1500 VDC For optional high isolation versions, 3000 VDC input to
output add suffix -H to model number
Switching Frequency 50 300 kHz
Isolation Resistance 109ΩInput to output, tested at 500 VDC
Isolation Capacitance 20 pF Input to output
Power Density 31.8 Win3
Mean Time Between Failure 3500 kHrs MIL-HDBK-217F, +25 °C GB
Weight 0.003 (1.5) lb (g)
Environmental
Characteristic Minimum Typical Maximum Units Notes & Conditions
Operating Temperature -40 +105 °C Derate from 100% load at +100 °C to 80% load at 105 °C
Storage Temperature -55 +125 °C
Case Temperature +115 °C
Operating Humidity 95 % RH Non-condensing
Cooling Natural convection