Specification sheet Deltapi N Series Pneumatic Transmitters Model NDA Differential pressure transmitter GENERAL CHARACTERISTICS The blind type dIfferential pressure transmitter, mod. NDA, is used to measure a differential pressure and convert it into a proportional pneumatic signal. The instrument works on the force-balance principle and consists of two main units: the measuring unit comprises a main body which houses a bellows unit, clamped in the main body forging by means of a flange. The bellows unit releves the differential pressure between the negative and positive connection ports; it can withstand the maximum rated static pressure on either side without damage. the transmission unit converts the differential force applied to the measuring element into a proportional output pneumatic signal. The output pressure, generated by a flapper nozzle relay, is fed to a feedback bellows with a rising pressure until the bellows force balances that of the measuring element. Span value continuously adjustable by an internal micrometric screw. Zero value adjustable by an external screw. Mounting in a vertical position on 2in diameter pipe by a special bracket. OPTIONAL EXTRA FEATURES A zero elevation or suppression device allows to set as a zero of the transmitter a measured variable value different from zero. The sum of the zero suppression value (S) plus the calibrated span cannot exceed the upper range limit (M) suitable by the diaphragm capsule : S + span M (see table). Air filter regulator can be directly mounted on the transmitter, with or without pressure gauge, and connected with piping and fittings either in stainless steel or copper. Special versions of air filter regulator and gauges, in stainless steel, are available on request. Oxygen measurements a special degreasing and final test operations can be required on the oxygen measuring transmitter. SPECIFICATIONS The data were obtained from laboratory tests on standard instruments with: carbon steel or AISI 316L body and flange; AISI 316L bellows unit; gasket: PTFE; calibration span: 800 kPa - 8 bar (bellows A), 1700 kPa - 17 bar (bellows B), 3500 kPa - 35 bar (bellows C), 7000 kPa - 70 bar (bellows D). MEASURING BELLOWS A B C D SPAN LIMITS min. and max. 170 and 1700 kPa 1.7 and 17 bar 350 and 3500 kPa 3.5 and 35 bar 700 and 7000 kPa 7 and 70 bar 1400 and 10000 kPa 14 and 100 bar RANGE LIMITS lower and upper (M) MAXIMUM ZERO SUPPRESSION (S) -2500 and +2500 kPa -25 and +25 bar -5000 and +5000 kPa -50 and +50 bar -10000 and +10000 kPa -100 and +100 bar -10000 and +10000 kPa -100 and +100 bar 2330 kPa 23.3 bar 4650 kPa 46.5 bar 9300 kPa 93 bar 8600 kPa 86 bar MAXIMUM ZERO ELEVATION STATIC PRESSURE LIMITS Full vacuum and 2500 kPa 25 bar 5000 kPa 50 bar 10000 kPa 100 bar 10000 kPa 100 bar 2.5 MPa (*) 25 bar (*) 5 MPa (*) 50 bar (*) 10 MPa (*) 100 bar (*) 10 MPa (*) 100 bar (*) (*) Equal to Maximum Working pressure as well as Overrange Limit Air supply nom. 140 kPa (1.4 bar, 20 psi); min. 125 kPa (1.25 bar, 18 psi); max. 175 kPa (1.75 bar, 25 psi) Output signal 20 to 100 kPa/0.2 to 1 bar, 3 to 15 psi or 0.2 to 1 kg/cm2 Static air consumption 350 Nl/h Maximum output flow - with rising output pressure: 30 Nl/min. - with falling output pressure: 40 Nl/min. Accuracy 0.5% F.S.D. (typical) Thermal drift (for ambient temperature variation between -20 C and + 65 C) Bellows A - span 170 to 340 kPa (1.7 to 3.4 bar): 0.6%/10C - span 340 to 1700 kPa (3.4 to 17 bar): 0.3%/10C Bellows B - span 350 to 700 kPa (3.5 to 7 bar): 0.6%/10C - span 700 to 3500 kPa (7 to 35 bar): 0.3%/10C Bellows C - span 700 to 1400 kPa (7 to 14 bar): 0.8%/10C - span 1400 to 7000 kPa (14 to 70 bar): 0.4%/10C Bellows D - span 1400 to 2800 kPa (14 to 28 bar): 1%/10C - span 2800 to 10000 kPa (28 to 100 bar): 0.5%/10C Pressure effect for variation of - Bellows A - 1.75 MPa (17.5 bar): 0.25% - Bellows B - 3.5 MPa (35 bar): 0.25% - Bellows C - 5 MPa (50 bar): 0.3% - Bellows D - 5 MPa (50 bar): 0.3% Degree of protection in accordance with IEC 529 IP55 Ambient temperature limits -40 and + 120C Body and flange material Carbon steel, AISI 316L, Monel Body bolts and nuts material high tensile carbon steel; AISI 316 Class A4-70 per ISO3506; high tensile stainless steel, in compliance with NACE MR0175 Measuring bellows material AISI 316 L, Monel Gasket material PTFE, Viton Cover material thermoplastic resin Surface protections - carbon steel body and flange: zinc plating and chrome passivation - AISI 316L body and flange: no protection Process connections (see figure ref. D and E) 1/2 in NPT-F Pneumatic connections - Air supply (in figure ref. A): 1/4 in NPT-F - Output (in figure ref. B): 1/4 in NPT-F Pressure gauge Brass with stainless steel case (all stainless steel on request) external diameter 51 mm; 0-200 kPa, 0-2 bar and 0-30 psi indication on 82 mm/260 scale. Air filter regulator with copper or stainless steel piping, as specified. Die cast aluminium alloy with light grey epoxy finish. Net weight (maximum) 7 kg approx Packing expanded polythene box ORDERING INFORMATION Select one character or set of characters from each category and specify complete catalog number. PRODUCT CODE abc de fg hi j k lm BASE MODEL VERSION BODY AND FLANGE MEASURING ELEMENT GASKETS OUTPUT EXTRAS Code abc BASE MODEL NDA Differential pressure transmitter de VERSION Standard with body bolts and nuts in high tensile carbon steel Standard with body bolts and nuts in AISI 316 Standard with body bolts and nuts in high tensile stainless steel fg 01 11 21 BODY AND FLANGE 01 11 21 Carbon steel / Carbon steel AISI 316L / AISI 316L Monel / Monel MEASURING ELEMENT hi Range limits kPa psi 2500 362 5000 725 10000 1450 10000 1450 2500 362 2500 362 5000 725 Bellows material AISI 316L AISI 316L AISI 316L AISI 316L Monel AISI 316L (*) AISI 316L (*) Span limits kPa (psi) - (Note 1) 170 and 1700 (24.6 and 246) 350 and 3500 (50.7 and 507) 700 and 7000 (101.5 and 1015) 1400 and 10000 (203 and 1450) 170 and 1700 (24.6 and 246) 170 and 1700 (24.6 and 246) 350 and 3500 (50.7 and 507) 01 02 03 04 21 41 42 Note 1: Multiply by 10 the value in kPa (MPa) to obtain mbar (bar). (*) Suitable for oxygen service GASKETS j Measuring element seal Viton PTFE (*) (*) k Fulcrum diaphragm seal Viton PTFE (*) 2 3 Suitable for oxygen service OUTPUT 3 to 15 psi 3 to 15 psi with zero elevation device 3 to 15 psi with zero suppression device 0.2 to 1.0 kg/cm2 0.2 to 1.0 kg/cm2 with zero elevation device 0.2 to 1.0 kg/cm2 with zero suppression device 20 to 100 kPa / 0.2 to 1 bar 20 to 100 kPa / 0.2 to 1 bar with zero elevation device 20 to 100 kPa / 0.2 to 1 bar with zero suppression device EXTRAS Identification lm tag material Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Piping material -Stainless Steel Copper Stainless Steel Copper According to ANSI/ISA S 51.1-1979 standard terminology Air filter regulator -with with with with Compliance to NACE class II bolting, according to specification MR0175, latest revision Pressure gauge ---with with 1 2 3 4 5 6 7 8 9 02 10 11 13 14 SS/NDA Rev 7 MOUNTING DIMENSIONS The Company's policy is one of continuous product improvement and the right is reserved to modify the specifications contained herein without notice. ABB Ltd. Howard Road St. Neots, Cambs. England PE19 8EU Tel. (01480) 475321 Facsimile (01480) 217948 ABB Inc. 125 East County Line Road Warminster, Pa 18974 USA Tel. (215) 674-6000 Facsimile (215) 674-7183 ABB Instrumentation spa Via Statale, 113 22016 Lenno (CO) Italia Tel. 0344 58111 Facsimile 0344 56278