MeshConnect TM EM35x Mini Modules ZICM35xSP0 and ZICM35xSP2 Ember EM35x Transceiver-Based Modules TM Integrated Transceiver Modules for ZigBee (R) / Thread / IEEE 802.15.4 Development Kit Available: ZICM-EM35X-DEV-KIT-3 DESCRIPTION EM35x Mini Modules The MeshConnect TM EM35x Mini Modules from California Eastern Laboratories (CEL) combine high performance RF solutions with the market's premier ZigBee (R) and Thread stacks. Available in low and high output power options (+8 dBm and +20 dBm), these modules can accommodate variable range and performance requirements. The tiny module footprint makes them suitable for a wide range of ZigBee and Thread applications. The MeshConnect EM35x Mini Modules are certified and qualified, enabling customers to accelerate time to market by greatly reducing the design and certification phases of development. Powered by EM357 KEY FEATURES: * 32-bit ARM (R) * 12 kB SRAM * 192 kB Flash Cortex TM-M3 * Up to 23 GPIO Pins or * SPI (Master /Slave), EM358x TWI and UART * Up to 64kB SRAM * Up to 512kB Flash (Supports OTA) * Optional USB Controller * Timers and Serial Wire /JTAG Interface * 5-Channel 14-bit ADC ZICM35xSP0 Tx: +8 dBm Rx: -100 dBm Link Budget: +108 dB CEL's MeshConnect EM35x Mini Modules (ZICM35xSP0 and ZICM35xSP2) are based on the Ember EM35x (EM357 and EM358x) System on Chip (SoC) radio ICs. Each IC is a complete single-chip solution, compliant with ZigBee, Thread, and IEEE 802.15.4. specifications. ZICM35xSP2 +20 dBm -103 dBm +123 dB ADDITIONAL FEATURES ** Data Rate: 250kbps ** Advanced Power Management ** 16 RF Channels ** Industry's Premier Wireless Networking Stacks: EmbeZNet PRO TM (ZigBee) and Silicon Labs Thread ** Mini Footprint: - 0.940" x 0.655" (23.9 mm x 16.6mm) CEL's EM358x-based Mini Modules (ZICM358xSP0 and ZICM358xSP2) are ideal for customers requiring Over-the-Air (OTA) programming without an external Flash memory (such as Smart Energy or Home Automation), a larger memory footprint for complex application control, or the additional resources to run an IPv6-based networking stack like Thread. They also feature an optional on-board Universal Serial Bus (USB) 2.0 full-speed peripheral. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Date Published: October 11, 2016 Ember (R) ZigBee (R) & Thread Solutions ** Antenna Options: 1) Integrated PCB Trace Antenna 2) RF Port for External Antenna ** Supports Mesh Networks ** AES Encryption ** FCC, CE and IC Certifications ** RoHS Compliant APPLICATIONS ** Smart Energy /Grid Markets ** Commercial and Residential - Thermostats Lighting - In-Home Displays - Fixtures and Control - Smart Plugs ** Solar Inverters and Control ** Home Automation and Control ** General ZigBee and Thread - Energy Management Wireless Sensor Networking - Security Devices - HVAC Control ** Building Automation and Control Page 1 Contributor Member EM35x Mini Modules TABLE OF CONTENTS Introduction and Overview Description.............................................................................................................................................................................................. 1 Features................................................................................................................................................................................................... 1 Applications............................................................................................................................................................................................ 1 Ordering Information.............................................................................................................................................................................. 3 ZICM35xSPx Product Comparison Table.............................................................................................................................................. 4 Module Block Diagram........................................................................................................................................................................... 4 Development Tools.................................................................................................................................................................................. 5 System Level Function Transceiver IC.......................................................................................................................................................................................... 6 Antenna.................................................................................................................................................................................................... 6 Power Amplifier....................................................................................................................................................................................... 6 USB........................................................................................................................................................................................................... 7 Software /Firmware................................................................................................................................................................................. 7 Electrical Specification Absolute Maximum Ratings................................................................................................................................................................... 8 Recommended Operating Condition..................................................................................................................................................... 8 DC Characteristics.................................................................................................................................................................................. 8 RF Characteristics.................................................................................................................................................................................. 9 Pin Signal and Interfaces Pin Signals I/O Configuration............................................................................................................................................................... 10 I/O Pin Assignment................................................................................................................................................................................ 10 Module Dimensions................................................................................................................................................................................ 11 Module Land Footprint........................................................................................................................................................................... 12 Processing.......................................................................................................................................................................................... 13 Agency Certifications.................................................................................................................................................................... 15 Software Compliance.................................................................................................................................................................... 16 Shipment, Storage and Handling............................................................................................................................................. 18 Quality................................................................................................................................................................................................... 18 References.......................................................................................................................................................................................... 19 Revision History............................................................................................................................................................................... 19 This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 2 Contributor Member EM35x Mini Modules ORDERING INFORMATION Part Number MeshConnect EM35x Mini Modules Description Min/ Multiple ZICM357SP0-1-R EM357 IC, +8 dBm output power, PCB trace antenna; Tape and Reel Package 600 /600 ZICM357SP0-1C-R EM357 IC, +8dBm output power with castellation pin for external antenna; Tape and Reel Package 600 /600 ZICM357SP2-1-R * EM357 IC, +20 dBm output power, PCB trace antenna; Tape and Reel Package 600 /600 ZICM357SP2-1C-R * EM357 IC, +20dBm output power with castellation pin for external antenna; Tape and Reel Package 600 /600 ZICM357SP2-2-R EM357 IC, +20 dBm output power, PCB trace antenna; Tape and Reel Package 600 /600 ZICM357SP2-2C-R EM357 IC, +20dBm output power with castellation pin for external antenna; Tape and Reel Package 600 /600 ZICM3588SP0-1-R EM3588 IC, +8 dBm output power, PCB trace antenna; Tape and Reel Package 600 /600 ZICM3588SP0-1C-R EM3588 IC, +8dBm output power with castellation pin for external antenna; Tape and Reel Package 600 /600 ZICM3588SP2-1-R * EM3588 IC, +20 dBm output power, PCB trace antenna; Tape and Reel Package 600 /600 ZICM3588SP2-1C-R * EM3588 IC, +20dBm output power with castellation pin for external antenna; Tape and Reel Package 600 /600 ZICM3588SP2-2-R * EM3588 IC, +20 dBm output power, PCB trace antenna; Tape and Reel Package 600 /600 ZICM3588SP2-2C-R * EM3588 IC, +20dBm output power with castellation pin for external antenna; Tape and Reel Package 600 /600 Order Number MeshConnect EM35x ZICM-EM35X-DEV-KIT-3 MeshConnect EM35x Ember Companion Kit for Ember EM35x Development Kit Development Kit 1/1 *Note: ZICM35xSP2-1(C) modules are not recommended for new designs, although there are no plans to stop production. Use ZICM35xSP2-2(C) instead. The -2 part numbers allow for faster 'time to sleep' state at the expense of one less GPIO (PC6). This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 3 Contributor Member EM35x Mini Modules ZICM35xSPx PRODUCT COMPARISON TABLE MCU Order Number Flash Memory SRAM Memory Performance USB ZICM357SP0-1 ZICM357SP0-1C ZICM357SP2-1 ZICM357SP2-1C I/O 23 192 kB 12 kB - 22 ZICM357SP2-2 ZICM357SP2-2C 21 ZICM3588SP0-1 ZICM3588SP0-1C 23 ZICM3588SP2-1 ZICM3588SP2-1C 22 512 kB 64 kB u ZICM3588SP2-2 ZICM3588SP2-2C Tx Power Output Rx Sensitivity Rx Current Tx Current Sleep / Suspend Current dBm dBm mA mA A +8 -100 30 44 +20 -103 34 150 +8 -100 30 44 +20 -103 34 150 Comments 1 Reduced GPIO allows for faster 'time to sleep' state 2.4 A with entire RAM retained. Lower sleep current can be achieved by retaining less RAM 2.4 21 1) 2.4 A with entire RAM retained. Lower sleep current can be achieved by retaining less RAM 2) Reduced GPIO allows for faster 'time to sleep' state MODULE BLOCK DIAGRAMS Castellation Edge Connector EM35x Mini Module (ZICM35xSP0) 24 MHz XTAL Ember EM35x Micro Castellation Edge Connector EM35x Mini Module (ZICM35xSP2) This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Balun Radio LPF 24 MHz XTAL Ember EM35x PA Micro Radio Page 4 LNA TX/RX Switch LPF Contributor Member EM35x Mini Modules DEVELOPMENT TOOLS Ember Companion Kit CEL's MeshConnect EM35x Ember Companion Kit is designed to work with the Silicon Laboratories / Ember Development Kits (EM35X-DEV and EM35X-DEV-IAR). Each module in the CEL Development Kit is soldered on a carrier board making it pin-for-pin compatible with the Ember Development Board. Mini Modules Programming Fixture CEL's MeshConnect EM35x Mini Modules Programming Fixture is a programming assembly designed to be used with the CEL ZICM35xSPx MeshConnect Mini Modules. It is useful for production programming or during application development when multiple firmware images are required to be loaded into a CEL Mini Module for testing and debugging. The programming assembly must be used in conjunction with an Ember Debug/InSight Adapter (ISA3) from Silicon Labs. EM35x Ember Companion Kit Kit Contents: * ZICM357SP0-1C-SL * ZICM357SP2-1-SL * ZICM357SP2-1C-SL * ZICM3588SP0-1C-SL * ZICM3588SP2-1-SL * ZICM3588SP2-1C-SL EM35x Programming Fixture For more information regarding the MeshConnect Development Tools, refer to the respective documents, or visit www.cel.com/MeshConnect. DEVELOPMENT TOOLS ORDERING INFORMATION Part Number Order Number Description MeshConnect EM35x Ember Companion Kit ZICM-EM35X-DEV-KIT-3 MeshConnect EM35x Ember Companion Kit for Silicon Laboratories/ Ember EM35x Development Kit MeshConnect EM35x Programming Fixture ZICM35xSPx-PF-1 MeshConnect EM35x Mini Modules (ZICM35xSPx) Programming Fixture This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 5 Contributor Member EM35x Mini Modules TRANSCEIVER IC CEL's MeshConnect EM35x Mini Modules use the Ember EM35x transceiver (EM357 or EM358x) IC. The IC incorporates a RF transceiver with baseband modem, a hardwired MAC and an embedded ARM (R) Cortex TM-M3 microcontroller, offering an excellent low cost, high performance solution for all IEEE 802.15.4 /ZigBee /Thread applications. For more information about the EM35x IC, visit www.silabs.com. ANTENNA CEL's MeshConnect EM35x Mini Modules include an integrated Printed Circuit Board (PCB) trace antenna. An optional configuration which uses a castellation pin on the module allows the user to connect an external antenna. The ZICM35xSP0 has been certified with the PCB trace antenna and two external antennas (E-2820CA, LSR 001-0100). The ZICM35xSP2 has been certified with the PCB trace antenna and a Nearson half-wave dipole antenna (part number: S181AH-2450S) on a 4 inch cable using the castellation pin of the module. Please refer to the document Mini Module External Antenna Implementation for details describing the requirements that must be followed to take advantage of the CEL certification. See Ordering Information on Page 3. The PCB antenna employs a topology that is compact and highly efficient. To maximize range, an adequate ground plane must be provided on the host PCB. Correctly positioned, the ground plane on the host PCB will contribute significantly to the antenna performance (it should not be directly under the module PCB Antenna). The position of the module on the host board and overall design of the product enclosure contribute to antenna performance. Poor design affects radiation patterns and can result in reflection, diffraction and/or scattering of the transmitted signal. For optimum antenna performance, the MeshConnect Modules should be mounted with the PCB trace antenna overhanging the edge of the host board. To further improve performance, a ground plane may be placed on the host board under the module, up to the antenna (a minimum of 1.5" x 1.5" is recommended). The installation of an uninterrupted ground plane on a layer directly beneath the module will also allow you to run traces under this layer. CEL can provide assistance with your PCB layout. The following are some design guidelines to help ensure antenna performance: * * * * * Never place the ground plane or route copper traces directly underneath the antenna portion of the module Never place the antenna close to metallic objects In the overall design, ensure that wiring and other components are not placed near the antenna Do not place the antenna in a metallic or metalized plastic enclosure Keep plastic enclosures 1cm or more away from the antenna in any direction This radio transmitter IC: 8254A-ZICM357SP0 & IC: 8254A-ZICM357SP2 has been approved by IC Canada to operate with the antenna types listed above with the maximum permissible gain of 2dBi. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Cet emetteur radio IC: 8254A-ZICM357SP0 & IC: 8254A-ZICM357SP2 a ete approuve par IC Canada pour fonctionner avec les types d'antenne enumeres ci-dessus avec le gain maximal admissible de 2dBi. Types d'antennes non inclus dans cette liste, ayant un gain superieur au gain maximum indique pour ce type, sont strictement interdits pour une utilisation avec cet appareil. POWER AMPLIFIER CEL's MeshConnect EM35x High Power Mini Module (ZICM35xSP2) includes a Power Amplifier (PA). This PA delivers high efficiency, high gain and high output power (Pout = +20.0 dBm typical) to provide an extended range and reliable transmission for fewer nodes in a network. For the ZICM35xSP2, Power Mode 2 with Power Setting -2 is the maximum setting allowed for FCC Compliance. Operating in Power Mode 3 at higher power settings may damage the PA. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 6 Contributor Member EM35x Mini Modules USB The ZICM3588SPx-x Modules have an integrated USB 2.0-compliant, full-speed (12 Mbps) device peripheral. For more information, refer to the EM35x SoC Datasheet link provided in the References Section of this document. SOFTWARE /FIRMWARE CEL's MeshConnect EM35x Mini Modules are ideal platforms for EmberZNet PRO, the industry's most deployed and field proven ZigBee compliant stack supporting the ZigBee PRO feature set. EmberZNet PRO is a complete ZigBee protocol software package containing all the elements required for mesh networking applications. The ZICM3588SPx variants are also ideal platforms for Thread, an IP-based mesh networking stack that allows direct IPv6 connectivity to all devices within the network. For more information regarding the software development for the EM35x IC family, visit www.silabs.com. CEL provides reference software that runs multiple functions and executes various commands. For example, users can set up a simple ZigBee network to perform Range and Packet Error Rate (PER) tests between two devices. This allows the user to evaluate the module's RF performance in their own environment. The software can also place the module in various operating modes which allows for testing of low-level RF performance, GPIO functionality, etc. The ZICM35xSP0 Module uses the transceiver's primary RF ports for transmitting and should use Power Mode 1 (EMBER_TX_POWER_MODE_BOOST in the EmberZNet API). The ZICM35xSP2 Module uses the transceiver's alternate RF ports for transmitting and should use Power Mode 2 (EMBER_TX_POWER_MODE_ALTERNATE in the EmberZNet API). GPIO PC5 must also be configured as ALT_OUT (push /pull). This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 7 Contributor Member EM35x Mini Modules ABSOLUTE MAXIMUM RATINGS MeshConnect ZICM35xSPx Module Description Unit Min Max Power Supply Voltage (VDD) -0.3 3.6 VDC Voltage on any I/O Line -0.3 VDD + 0.3 VDC - - +15 +5 dBm -40 125 C - 260 C RF Input Power ZICM35xSP0 ZICM35xSP2 Storage Temperature Range Reflow Soldering Temperature Note: Exceeding the maximum ratings may cause permanent damage to the module or devices. RECOMMENDED OPERATING CONDITIONS MeshConnect ZICM35xSPx Module Description Power Supply Voltage (VDD) Input Frequency Ambient Temperature Range Unit Min Typ Max 2.1 3.3 3.6 VDC 2405 - 2480 MHz -40 25 85 C DC CHARACTERISTICS (@ 25C, VDD = 3.3V, ZICM35xSP0 TX Power Mode 1, ZICM35xSP2 TX Power Mode 2) MeshConnect ZICM35xSPx Module Description Transmit Mode Current @ +8 dBm Transmit Mode Current @ 0 dBm ZICM35xSP0 Unit Min Typ Max - 44 - mA - 31 - mA Receive Mode Current - 30 - mA Transmit Mode Current @ +20 dBm - 150 - mA - 58 - mA Transmit Mode Current @ 0 dBm ZICM35xSP2 Receive Mode Current - 34 - mA Sleep Mode Current ZICM357SPx - 1 - A Sleep Mode Current ZICM358xSPx - 2.4* - A *Note: The increased sleep current on the ZICM358xSPx is at 3.6VDC with all the RAM retained. Lower sleep currents can be achieved if less RAM is retained during sleep. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 8 Contributor Member EM35x Mini Modules RF CHARACTERISTICS (@ 25C, VDD = 3.3V, ZICM35xSP0 TX Power Mode 1, ZICM35xSP2 TX Power Mode 2) MeshConnect ZICM35xSPx Module Description Unit Min Typ Max 2405 - 2480 11 - 26 - -96.2 - 96.2 kHz - +8 - dBm - -40 - dBm Offset Error Vector Magnitude - 5 35 % Maximum Output Power (using Power Mode 2, Power Setting -2) - +20 21 dBm - -40 - dBm - 5 35 % - -100 -94 dBm 0 - - dBm - -103 -97 dBm -10 - - dBm General Characteristics RF Frequency Range RF Channels Frequency Error Tolerance MHz Transmitter Maximum Output Power Minimum Output Power Minimum Output Power ZICM35xSP0 ZICM35xSP2 Offset Error Vector Magnitude Receiver Sensitivity (1% PER, Boost Mode) Saturation (Maximum Input Level) Sensitivity (1% PER, Normal Mode) Saturation (Maximum Input Level) ZICM35xSP0 ZICM35xSP2 Note: The ZICM35xSP2, Power Mode 2 with Power Setting -2 is the maximum setting allowed for FCC Compliance. Operating in Power Mode 3 at higher power settings may damage the PA. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 9 Contributor Member EM35x Mini Modules PIN SIGNALS I/O PORT CONFIGURATION CEL's MeshConnect Module has 33 edge I/O interfaces for connection to the user's host board. See the MeshConnect Module Dimensions Section which details the layout of the 33 edge castellations. I/O PIN ASSIGNMENTS CEL MeshConnect ZICM35xSPx Module Pin Number EM35x IC Pin Number Name 1, 2, 12, 31, 33 49 GROUND 3 11 PC5 4 12 RESET 5 13 PC6 6 7 8 9 10 11 13 14 18 19 20 21 22 16, 23, 28, 37 PC7 PA7 PB3 PB4 PA0 PA1 VDD 15 16 17 18 19 20 21 25 26 27 29 30 31 32 PA2 PA3 PA4 PA5 PA6 PB1 PB2 JTCK Digital I /O 22 33 PC2 Digital I /O 23 24 25 26 27 34 35 36 38 40 PC3 PC4 PB0 PC1 PC0 Digital I / O Digital I / O Digital I / O Digital I / O Digital I / O 32 NC RF Out 14 28 29 30 24 41 42 43 This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) PB7 PB6 PB5 Notes ZICM35xSP0: Digital I/O ZICM35xSP2: Dedicated as TX_ACTIVE. The EM35x baseband controls TX_ACTIVE and drives it high when in TX mode; since it is used internally in the module, PC5 is not connected to module I/O pin 3 Active Low chip reset (Input) ZICM35xSP0: Digital I/O ZICM35xSP2-1: Digital I/O ZICM35xSP2-2: Used internally in the module; PC6 is not connected to module I/O pin 5 Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O Digital I /O JTAG clock input from debugger Digital I /O Digital I / O Digital I / O Castellation Pin for external Antenna Page 10 Contributor Member EM35x Mini Modules MODULE DIMENSIONS MeshConnect EM35x Mini Modules EM300 Series Module Pin 1 R1 C14 L2 R7 U1 C9 C6 C6A C1 L6 C6B EM357 Series ARM R6 R9 C4A C17 Pin 33 C22 R8 C5B R2 C10 Pin 11 C24 R11 C23 L5 C11 L3 C13 L4 R10 0.940" (23.87 mm) C21 C7 C7B C20 C20 ZICM35xSPx 0000-00-00-00-000 R5 C2 R4 C16 XTAL1 C15 Pin 22 0.062" (1.57 mm) 0.152" (3.86 mm) MAX 0.655" (16.63 mm) Note: All dimensions are +/- 0.005" (0.12 mm) unless otherwise specified. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 11 Contributor Member EM35x Mini Modules MODULE LAND FOOTPRINT Dimensions are shown in inches, with millimeter conversions in brackets. 0.655" [16.64] 0.465" [11.80] 0.221" [5.61] 0.236" [5.98] O0.140" [O3.56] 0.940" [23.88] 0.590" [14.98] 0.985" [25.02] 0.540" [13.73] PITCH 0.050" [1.27] 33X 0.090" [2.29] X 0.040" [1.02] 0.084" [2.13] 0.084" [2.13] 0.082" [2.09] 0.490" [12.45] 0.746" [18.95] Note: Refer to the Antenna Section in this document for layout recommendations which will yield optimal antenna performance. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 12 Contributor Member EM35x Mini Modules PROCESSING Recommended Reflow Profile Parameter Values Ramp Up Rate (from Tsoakmax to Tpeak) 3 /sec max Tsoakmin 150 C Tsoakmax 200 C Soak Time 60-120 sec TLiquidus 217 C Time above TLiquidus 60-150 sec Tpeak 250 C Time within 5 of Tpeak 20-30 sec Time from 25 to Tpeak 8 min max Ramp Down Rate 6 C /sec max Pb-Free Solder Paste Use of "No Clean" soldering paste is strongly recommended, as it does not require cleaning after the soldering process. Note: The quality of solder joints on the castellations ("half vias") where they contact the host board should meet the appropriate IPC Specification. See the Castellated Terminations Section in the latest IPC-A-610 Acceptability of Electronic Assemblies document. Cleaning In general, cleaning the populated module is strongly discouraged. Residuals under the module cannot be easily removed with any cleaning process. * * * Cleaning with water can lead to capillary effects where water is absorbed into the gap between the host board and the module. The combination of soldering flux residuals and encapsulated water could lead to short circuits between neighboring pads. Water could also damage any stickers or labels. Cleaning with alcohol or a similar organic solvent will likely flood soldering flux residuals into the two housings, which is not accessible for post-washing inspection. The solvent could also damage any stickers or labels. Ultrasonic cleaning could damage the module permanently. The best approach is to consider using a "No Clean" solder paste and eliminate the post-soldering cleaning step. Optical Inspection After soldering the module to the host board, consider optical inspection to check the following: * Proper alignment and centering of the module over the pads * Proper solder joints on all pads * Excessive solder or contacts to neighboring pads or vias Repeating Reflow Soldering Only a single reflow soldering process is encouraged for host boards. Wave Soldering If a wave soldering process is required on the host boards due to the presence of leaded components, only a single wave soldering process is encouraged. Hand Soldering Hand soldering is possible. When using a soldering iron, follow IPC recommendations (reference document IPC-7711). This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 13 Contributor Member EM35x Mini Modules Rework The MeshConnect Module can be unsoldered from the host board. Use of a hot air rework tool should be programmable and the solder joint and module should not exceed the maximum peak reflow temperature of 250 C. Caution If temperature ramps exceed the reflow temperature profile, module and component damage may occur due to thermal shock. Avoid overheating. Warning Never attempt a rework on the module itself (i.e., replacing individual components); such actions will terminate warranty coverage. Additional Grounding Attempts to improve the module or the system grounding by soldering braids, wires or cables onto the module RF shield cover is done at the customer's own risk. The ground pins at the module perimeter should be sufficient for optimum immunity to external RF interference. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 14 Contributor Member EM35x Mini Modules AGENCY CERTIFICATIONS The following Part Numbers are Certified as shown below: Part Number Certifications Antenna ZICM35xSP0-1 FCC, IC, CE PCB ZICM35xSP0-1C FCC, IC, CE E-2820-CA, LSR 001-0100 ZICM35xSP2-x FCC, IC PCB ZICM35xSP2-xC FCC, IC Nearson S181AH-2450S FCC and Canada Compliance Statement This device complies with Part 15 of the FCC Rules and with IC Canada licence-exempt RSS Standards. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Declaration De Conformite FCC Et Au Canada Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes: 1. l'appareil ne doit pas produire de brouillage, et 2. l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. Warning (Part 15.21) Changes or modifications not expressly approved by CEL could void the user's authority to operate the equipment. 20 cm Separation Distance To comply with FCC /IC Canada RF exposure limits for general population /uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operated in conjunction with any other antenna or transmitter except in accordance with FCC muti-transmitter product procedures. 20cm Distance De Separation Pour se conformer aux limites d'exposition FCC / IC Canada RF pour la population generale / exposition non controlee, l'antenne(s) utilisee pour ce transmetteur doit etre installe pour fournir une distance de separation d'au moins 20cm de toutes les personnes et ne doit pas etre co-implantes ou exploites en conjonction avec une autre antenne ou emetteur, sauf en conformite avec les procedures de produits muti-emetteur FCC. OEM Responsibility to the FCC and IC Rules and Regulations The MeshConnect Mini Module has been certified per FCC Part 15 Rules and to IC Canada license-exempt RSS Standards for integration into products without further testing or certification. To fulfill the FCC and IC Certification requirements, the OEM of the MeshConnect Module must ensure that the information provided on the MeshConnect label is placed on the outside of the final product. The MeshConnect Mini Module is labeled with its own FCC ID Number and IC ID Number. If the FCC ID and the IC ID are not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. The exterior label can use wording such as the following: This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 15 Contributor Member EM35x Mini Modules or "Contains Transmitter Module FCC ID: W7Z-ZICM357SP0" or "Contains FCC ID: W7Z-ZICM357SP0" "Contains Transmitter Module IC: 8254A-ZICM357SP0" or "Contains IC: 8254A-ZICM357SP0" "Contains Transmitter Module FCC ID: W7Z-ZICM357SP2" or "Contains FCC ID: W7Z-ZICM357SP2" "Contains Transmitter Module IC: 8254A-ZICM357SP2" or "Contains IC: 8254A-ZICM357SP2" The OEM of the MeshConnect Mini Module may only use the approved antennas (PCB Trace Antenna and external antenna) that have been certified with this module. The OEM of the MeshConnect Mini Module must test their final product configuration to comply with Unintentional Radiator Limits before declaring FCC Compliance per Part 15 of the FCC Rules. The OEM must also include in their manual the following statement: FCC and Canada Compliance Statement This device complies with Part 15 of the FCC Rules and with IC Canada licence-exempt RSS Standards. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Declaration De Conformite FCC Et Au Canada Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes: 1. l'appareil ne doit pas produire de brouillage, et 2. l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. In addition to using only the approved external antennas, the OEM must follow the layout described in the "Mini Module External Antenna Implementation Guide" to be covered by the current approval. CE Certification -- Europe The MeshConnect ZICM35xSP0 Module has been tested and certified for use in the European Union. OEM Responsibility to the European Union Compliance Rules If the MeshConnect Module is to be incorporated into a product, the OEM must verify compliance of the final product to the European Harmonized EMC and Low-Voltage/Safety Standards. A Declaration of Conformity must be issued for each of these standards and kept on file as described in Annex II of the R&TTE Directive. The manufacturer must maintain the user guide and adhere to the settings described in the manual for maintaining European Union Compliance. If any of the specifications are exceeded in the final product, the OEM is required to make a submission to the notified body for compliance testing. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 16 Contributor Member EM35x Mini Modules OEM Labeling Requirements The CE mark must be placed on the OEM product in a visible location. The CE mark shall consist of the initials CE with the following form: * If the CE marking is reduced or enlarged, the proportions given in the CE graduated drawing (to the right) must be adhered to * The CE mark must be a minimum of 5 mm in height * If the use of the module is subject to restrictions in the end application, the CE marking on the OEM product should also include the alert sign as shown in the image to the right Software Compliance The MeshConnect Mini Modules require software restrictions to meet agency certification requirements. These restrictions have been implemented in the sample application included with the Software Development Kit. If a customer is not starting with the CEL Software Development Kit, they must implement the following output power restrictions to use the FCC, IC or CE Certifications: Part Number ZICM35xSP0-1 Certification FCC /IC ETSI ZICM35xSP0-1C FCC /IC ETSI ZICM35xSP2-x ZICM35xSP2-xC FCC /IC FCC /IC RF Channel Valid TX Power Steps Typical Max Output Power 11 - 25 -43 to 8 8 dBm 26 -43 to 0 1 dBm 11 - 26 -43 to 8 8 dBm 11 - 25 -43 to 8 8 dBm 26 -43 to -7 -7 dBm 11 - 26 -43 to 8 8 dBm 11 - 24 -43 to -2 20 dBm 25 -43 to -6 17 dBm 26 -43 to -21 -5 dBm 11 - 24 -43 to -2 20 dBm 25 -43 to -12 9 dBm 26 -43 to -21 -5 dBm Note: The ZICM35xSP2, Power Mode 2 with Power Setting -2 is the maximum setting allowed for FCC Compliance. Operating in Power Mode 3 at higher power settings may damage the PA. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 17 Contributor Member EM35x Mini Modules SHIPMENT, HANDLING AND STORAGE Shipment The MeshConnect Modules are delivered in Tape and Reel for easy assembly in a manufacturing environment. The reel diameter is 12.992 inches (330 mm) and contains 600 modules Tape and Reel Dimensions Measurements are in inches [mm] Handling The MeshConnect Modules are designed and packaged to be processed in an automated assembly line. 0.0790.004 [2.000.10] 0.157 [4.00] PITCH 0.9570.004 [24.300.10] 0.0710.004 [1.750.10] A B B 0.7950.006 [20.200.15] 1.7320.011 [44.000.30] 0.0140.002 [0.350.05] 0.1690.004 [4.300.10] A 0.9450.004 [24.000.10] 0.6690.004 [17.000.10] SECTION A-A SECTION B-B Warning The MeshConnect Modules contain highly sensitive electronic circuitry. Handling without proper ESD protection may destroy or damage the module permanently. Warning The MeshConnect Modules are moisture-sensitive devices. Appropriate handling instructions and precautions are summarized in J-STD-033. Read carefully to prevent permanent damage due to moisture intake. Moisture Sensitivity Level (MSL) MSL 3, per J-STD-033 Storage Storage /shelf life in sealed bags is 12 months at < 40C and < 90% relative humidity. QUALITY CEL Modules offer the highest quality at competitive prices. Our modules are manufactured in compliance with the IPC-A-610 specification, Class II. Our modules go through JESD22 qualification processes which include high temperature operating life tests, mechanical shock, temperature cycling, humidity and reflow testing. CEL conducts RF and DC factory testing on 100% of all production parts. CEL builds the quality into our products, giving our customers confidence when integrating our products into their systems. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 18 Contributor Member EM35x Mini Modules REFERENCES Download Reference Documents 120-035X-000 - Silicon Labs /Ember EM35x SoC Datasheet Link 0011-02-17-00-000 - CEL EM35x Ember Mini Module Companion Kit Technical User Guide Link 0011-01-16-05-000 - Using the ZICM35xSPx Mini Module Programming Fixture Link 0011-00-16-11-000 - CEL ZICM35xSP2-1C External Antenna Implementation Link REVISION HISTORY Previous Versions Changes to Current Version Page(s) 0011-00-07-01-000 (Issue A) July 22, 2013 Initial Preliminary Datasheet 0011-00-07-01-000 (Issue B) August 1, 2013 Updated Development Tools Section, Antenna Section, Agency Certifications, Software Compliance Section 0011-00-07-01-000 (Issue C) February 10, 2014 Updated Tape and Reel Packaging 0011-00-07-01-000 (Issue D) March 17, 2014 Updated ZICM358xSPx Sleep Mode Current. Removed "Preliminary" status for this datasheet. Updated Software Compliance "Valid" TX Power Steps" table values 0011-00-07-01-000 (Issue E) March 18, 2014 This datasheet is now a "Preliminary Datasheet" due to the addition of new part numbers (ZICM357SP2-2, ZICM357SP2-2-R, ZICM357SP2-2C and ZICM357SP2-2C-R) to the "Ordering Information". Added new "ZICM35xSPx Product Comparison Table". 1, 3 0011-00-07-01-000 (Issue F) July 15, 2014 Removed "Preliminary" status for this datasheet. Updated Programming Fixture Product Photography 1, 5 0011-00-07-01-000 (Issue G) July 20, 2014 Added part numbers ZICM3588SP2-2(C), updated Logos 0011-00-07-01-000 (Issue H) October 11, 2016 Changed "Industry Canada" to "IC Canada" throughout document. Updated Antenna Section and added a new part number to Agency Certifications table. Added ZICM35xSP0-1C to Software compliance table. Removed option for tray configuration This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) All Page 19 4, 5, 14, 16, 17 3, 17 1, 7, 16 3 4,6,15,17,18 Contributor Member EM35x Mini Modules Disclaimer The information in this document is current as of the published date. The information is subject to change without notice. For actual design-in, refer to the latest publications of CEL Data Sheets or Data Books, etc., for the most up-to-date specifications of CEL products. Not all products and/or types are available in every country. Please check with an CEL sales representative for availability and additional information. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of CEL. CEL assumes no responsibility for any errors that may appear in this document. CEL does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from the use of CEL products listed in this document or any other liability arising from the use of such products. No license, express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of CEL or others. Descriptions of circuits, software and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples. The incorporation of these circuits, software and information in the design of a customer's equipment shall be done under the full responsibility of the customer. CEL assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits, software and information. While CEL endeavors to enhance the quality, reliability and safety of CEL products, customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely. To minimize risks of damage to property or injury (including death) to persons arising from defects in CEL products, customers must incorporate sufficient safety measures in their design, such as redundancy, firecontainment and anti-failure features. For More Information For more information about CEL MeshConnect products and solutions, visit our website at: www.cel.com/MeshConnect. Technical Assistance For Technical Assistance, visit www.cel.com/MeshConnectHelp. This document is subject to change without notice Document No: 0011-00-07-01-000 (Issue H) Page 20 Contributor Member Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: CEL: ZICM357SP0-1-MW ZICM357SP0-1C-MW ZICM357SP2-1-MW ZICM357SP2-1C-MW ZICM3588SP0-1-MW ZICM3588SP0-1C-MW ZICM3588SP2-1-MW ZICM3588SP2-1C-MW