FEATURES * 1 0,000-count LCD display excellent resolution *100Aac/dc Ammeter with low 10A range (1mA resolution) * Tapered jaws for crowded wiring areas (O.60"- 15mm Jaw opening) (O.45"- 12mm Cable diameter) *600Vac/dc voltmeter * Analog output in Aac/dc to data loggers, etc * Auto-ranging & Adc zero push-button * Data HOLD & PEAK functions * Relative function to compare two measurements * Ohm range & continuity test with beeper * Auto Power OFF and low battery indicator * IEC/EN 61010 safety rated & CE mark * 600Vrms overload protection UT L AT I V E UN F Frequency Range DC Current (positive only) Measurement Ranges Accuracy & Resolution RE G OUT ELECTRICAL AC Current Measurement Ranges Accuracy & Resolution CM605 & DC P LO SPECIFICATIONS MODEL 2 Ranges: 10A, 100A 10A: 2.0% of Reading 10cts - 1mA Resolution 80A: 2.0% of Reading 10cts - 10mA Resolution > 80A: 3.5% of Reading 10cts - 10mA Resolution 2 Ranges: 50 to 500Hz C TIO 2 Ranges: 10A, 100A 10A: 2.5% of Reading 10cts - 1mA Resolution 80A: 2.5% of Reading 10cts - 10mA Resolution > 80A: 4.5% of Reading 10cts - 10mA Resolution AC Volts Measurement Ranges 600Vrms Accuracy & Resolution 1.5% of Reading 5cts - 100mV Resolution Frequency 40 to 500Hz Input Impedance 10M, < 50pF DC Volts (positive only)* 600V Measurement Ranges Accuracy & Resolution 1.0% of Reading 2cts - 100mV Resolution Input Impedance 10M Resistance (Ohms) Measurement Ranges 10k (9999) Accuracy & Resolution 1.0% of Reading 3cts - 1 Resolution Test Voltage < 3.0Vdc Continuity Measurement Ranges Buzzer < 100 25 Resolution 1 Test Voltage < 3.0Vdc Analog Output Output 10mV/Aac & Adc through front banana jacks Frequency 0 to 20kHz @ 3db Output Impedance 3k, < 50pF Other Functions Adc Zero & One touch push button (ZERO Button) to Zero Adc, or other readings. Relative Function Relative function also used in the other ranges to compare two measurements. HOLD Function Holds A & V measurements when pressed (HOLD button) PEAK Function Captures PEAK (1ms) V or A measurement when activated (PEAK Button) Auto-Ranging "AUTO" displayed on LCD Over Range "OL" displayed on LCD for all measurements Auto Power OFF Auto Power OFF after approx 10 minute with Over-Ride Low Battery Low Battery indication on LCD MECHANICAL Max. Cable Diameter O 0.45" (12mm) Max. Jaw Opening O 0.60" (15mm) Power Source Two 1.5V AAA (LR03) batteries (included) Dimensions & Weight 7.95 x 2.76 x 1.33" (202 x 70 x 34mm) - 6.5 oz (180g) IEC/EN 61010-1 and 2-032 - 600V CAT II and 300V CAT III - Pollution Degree 2 Safety Standards Class 2 - Double or reinforced insulation, CE mark *For negative measurement, add 2cts to the accuracy PRODUCT INCLUDES Soft carrying case, test leads, two 1.5V AAA batteries and user manual. CATALOG NO. DESCRIPTION 7000.02 Clamp-On Meter Model CM605 (100Aac/dc, Low Current) Technical Assistance (800) 343-1391 ION L T R SO E AC A UT R C A AC/D m N AN For general industrial monitoring and troubleshooting CURRE Model CM605 Special product features 1 CLAMP-ON METERS 100Aac/dc Low Current www.aemc.com N