5
MY MY
Contact resistance 50 mΩ max.
Operate time 20 ms max.
Release time 20 ms max.
Operating frequency Mechanically 18,000 operations/hour
Under rated load 1,800 operations/hour
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Single contact type Unsealed: 2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Sealed: 1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Hermetically sealed: 1,000 VAC, 50/60 Hz for 1 minute
700 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Bifurcated contact type 1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts
Vibration Mechanical durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Shock Mechanical durability 1,000 m/s2 (approx. 100 G)
Malfunction durability 200 m/s2 (approx. 20 G)
Ambient temperature Operating Unsealed: -55° to 70°C (-67° to 158°F)
Sealed: -55° to 60°C (-67° to 140°F)
Hermetically sealed: 25° to 60°C (77° to 140°F)
Humidity 35% to 85% RH
Ser vice Life Mechanically Single contact type:
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
Mechanically Bifurcated contact type:
AC: 50 million operations min.
DC: 20 million operations min. (5 million operations for the sealed/hermetically
sealed types) (at operating frequency of 1,800 operations/hour)
Electrically See “Characteristic Data”
Weight Sealed/unsealed: Approx. 35 g (1.23 oz)
Hermetically sealed: Approx. 50 g (1.76 oz)
■CHARACTERISTICS
Non-latching
Note: Data shown are of initial value.
Contact resistance 50 mΩ max.
Operate time AC: 30 ms max.; DC: 15 ms max.
Release time AC: 30 ms max.; DC: 15 ms max.
Operating frequency Mechanically 18,000 operations/hour
Under rated load 1,800 operations/hour
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity, and between
set and reset coils
Vibration Mechanical durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Shock Mechanical durability 1,000 m/s2 (approx. 100 G)
Malfunction durability 200 m/s2 (approx. 20 G)
Ambient temperature Operating -55° to 70°C (-67° to 158°F)
Humidity 45% to 85% RH
Ser vice Life Mechanically 100 million operations min. (at operating frequency of 18,000 operations/hour)
Electrically See “Characteristic Data”
Weight Approx. 30 g (1.06 oz)
Latching