1E2B
Cylindrical Proximity Sensor
E2B
The high reliability and new
design for standard industrial
in-door applications with the
best balance of costs-
performance.
All standard models M8, M12, M18 and M30
Single and double sensing distance
Normally open (NO), normally closed (NC)
IP67 for protection in wet environments
Round visible LED for operation control
Standard temperature range –25°C to 70°C
Ordering Information
Double sensing distance, DC 3-wire models
Size Sensing
distance Connection Body
material
Body
length Output Operation mode NO Operation mode NC
M8
Shielded 2 mm
Pre-wired
Stainless
steel
Short PNP E2B-S08KS02-WP-B1 2M OMS E2B-S08KS02-WP-B2 2M OMS
NPN E2B-S08KS02-WP-C1 2M OMS E2B-S08KS02-WP-C2 2M OMS
Long PNP E2B-S08LS02-WP-B1 2M OMS E2B-S08LS02-WP-B2 2M OMS
NPN E2B-S08LS02-WP-C1 2M OMS E2B-S08LS02-WP-C2 2M OMS
M8 connector
(3-pin)
Short PNP E2B-S08KS02-MC-B1 OMS E2B-S08KS02-MC-B2 OMS
NPN E2B-S08KS02-MC-C1 OMS E2B-S08KS02-MC-C2 OMS
Long PNP E2B-S08LS02-MC-B1 OMS E2B-S08LS02-MC-B2 OMS
NPN E2B-S08LS02-MC-C1 OMS E2B-S08LS02-MC-C2 OMS
Non-
Shielded 4mm
Pre-wired
Short PNP E2B-S08KN04-WP-B1 2M OMS E2B-S08KN04-WP-B2 2M OMS
NPN E2B-S08KN04-WP-C1 2M OMS E2B-S08KN04-WP-C2 2M OMS
Long PNP E2B-S08LN04-WP-B1 2M OMS E2B-S08LN04-WP-B2 2M OMS
NPN E2B-S08LN04-WP-C1 2M OMS E2B-S08LN04-WP-C2 2M OMS
M8 connector
(3-pin)
Short PNP E2B-S08KN04-MC-B1 OMS E2B-S08KN04-MC-B2 OMS
NPN E2B-S08KN04-MC-C1 OMS E2B-S08KN04-MC-C2 OMS
Long PNP E2B-S08LN04-MC-B1 OMS E2B-S08LN04-MC-B2 OMS
NPN E2B-S08LN04-MC-C1 OMS E2B-S08LN04-MC-C2 OMS
M12
Shielded 4 mm
Pre-wired
Brass
Short PNP E2B-M12KS04-WP-B1 2M OMS E2B-M12KS04-WP-B2 2M OMS
NPN E2B-M12KS04-WP-C1 2M OMS E2B-M12KS04-WP-C2 2M OMS
Long PNP E2B-M12LS04-WP-B1 2M OMS E2B-M12LS04-WP-B2 2M OMS
NPN E2B-M12LS04-WP-C1 2M OMS E2B-M12LS04-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M12KS04-M1-B1 OMS E2B-M12KS04-M1-B2 OMS
NPN E2B-M12KS04-M1-C1 OMS E2B-M12KS04-M1-C2 OMS
Long PNP E2B-M12LS04-M1-B1 OMS E2B-M12LS04-M1-B2 OMS
NPN E2B-M12LS04-M1-C1 OMS E2B-M12LS04-M1-C2 OMS
Non-
Shielded 8mm
Pre-wired
Short PNP E2B-M12KN08-WP-B1 2M OMS E2B-M12KN08-WP-B2 2M OMS
NPN E2B-M12KN08-WP-C1 2M OMS E2B-M12KN08-WP-C2 2M OMS
Long PNP E2B-M12LN08-WP-B1 2M OMS E2B-M12LN08-WP-B2 2M OMS
NPN E2B-M12LN08-WP-C1 2M OMS E2B-M12LN08-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M12KN08-M1-B1 OMS E2B-M12KN08-M1-B2 OMS
NPN E2B-M12KN08-M1-C1 OMS E2B-M12KN08-M1-C2 OMS
Long PNP E2B-M12LN08-M1-B1 OMS E2B-M12LN08-M1-B2 OMS
NPN E2B-M12LN08-M1-C1 OMS E2B-M12LN08-M1-C2 OMS
2Inductive Sensors
*1. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).
Single sensing distance, DC 3-wire models
M18
Shielded 8 mm
Pre-wired
Brass
Short PNP E2B-M18KS08-WP-B1 2M OMS E2B-M18KS08-WP-B2 2M OMS
NPN E2B-M18KS08-WP-C1 2M OMS E2B-M18KS08-WP-C2 2M OMS
Long PNP E2B-M18LS08-WP-B1 2M OMS E2B-M18LS08-WP-B2 2M OMS
NPN E2B-M18LS08-WP-C1 2M OMS E2B-M18LS08-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M18KS08-M1-B1 OMS E2B-M18KS08-M1-B2 OMS
NPN E2B-M18KS08-M1-C1 OMS E2B-M18KS08-M1-C2 OMS
Long PNP E2B-M18LS08-M1-B1 OMS E2B-M18LS08-M1-B2 OMS
NPN E2B-M18LS08-M1-C1 OMS E2B-M18LS08-M1-C2 OMS
Non-
Shielded 16 mm
Pre-wired
Short PNP E2B-M18KN16-WP-B1 2M OMS E2B-M18KN16-WP-B2 2M OMS
NPN E2B-M18KN16-WP-C1 2M OMS E2B-M18KN16-WP-C2 2M OMS
Long PNP E2B-M18LN16-WP-B1 2M OMS E2B-M18LN16-WP-B2 2M OMS
NPN E2B-M18LN16-WP-C1 2M OMS E2B-M18LN16-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M18KN16-M1-B1 OMS E2B-M18KN16-M1-B2 OMS
NPN E2B-M18KN16-M1-C1 OMS E2B-M18KN16-M1-C2 OMS
Long PNP E2B-M18LN16-M1-B1 OMS E2B-M18LN16-M1-B2 OMS
NPN E2B-M18LN16-M1-C1 OMS E2B-M18LN16-M1-C2 OMS
M30
Shielded 15 mm
Pre-wired
Brass
Short PNP E2B-M30KS15-WP-B1 2M OMS E2B-M30KS15-WP-B2 2M OMS
NPN E2B-M30KS15-WP-C1 2M OMS E2B-M30KS15-WP-C2 2M OMS
Long PNP E2B-M30LS15-WP-B1 2M OMS E2B-M30LS15-WP-B2 2M OMS
NPN E2B-M30LS15-WP-C1 2M OMS E2B-M30LS15-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M30KS15-M1-B1 OMS E2B-M30KS15-M1-B2 OMS
NPN E2B-M30KS15-M1-C1 OMS E2B-M30KS15-M1-C2 OMS
Long PNP E2B-M30LS15-M1-B1 OMS E2B-M30LS15-M1-B2 OMS
NPN E2B-M30LS15-M1-C1 OMS E2B-M30LS15-M1-C2 OMS
Non-
Shielded 30 mm
Pre-wired Long PNP E2B-M30LN30-WP-B1 2M OMS E2B-M30LN30-WP-B2 2M OMS
NPN E2B-M30LN30-WP-C1 2M OMS E2B-M30LN30-WP-C2 2M OMS
M12 connector
(4-pin) Long PNP E2B-M30LN30-M1-B1 OMS E2B-M30LN30-M1-B2 OMS
NPN E2B-M30LN30-M1-C1 OMS E2B-M30LN30-M1-C2 OMS
Size Sensing
distance Connection Body
material
Body
length Output Operation mode NO Operation mode NC
Size Sensing
distance Connection Body
material
Body
length Output Operation mode NO Operation mode NC
M8
Shielded 1 mm
Pre-wired
Stainless
steel
Short PNP E2B-S08KS01-WP-B1 2M OMS E2B-S08KS01-WP-B2 2M OMS
NPN E2B-S08KS01-WP-C1 2M OMS E2B-S08KS01-WP-C2 2M OMS
Long PNP E2B-S08LS01-WP-B1 2M OMS E2B-S08LS01-WP-B2 2M OMS
NPN E2B-S08LS01-WP-C1 2M OMS E2B-S08LS01-WP-C2 2M OMS
M8 connector
(3-pin)
Short PNP E2B-S08KS01-MC-B1 OMS E2B-S08KS01-MC-B2 OMS
NPN E2B-S08KS01-MC-C1 OMS E2B-S08KS01-MC-C2 OMS
Long PNP E2B-S08LS01-MC-B1 OMS E2B-S08LS01-MC-B2 OMS
NPN E2B-S08LS01-MC-C1 OMS E2B-S08LS01-MC-C2 OMS
Non-
Shielded 2mm
Pre-wired
Short PNP E2B-S08KN02-WP-B1 2M OMS E2B-S08KN02-WP-B2 2M OMS
NPN E2B-S08KN02-WP-C1 2M OMS E2B-S08KN02-WP-C2 2M OMS
Long PNP E2B-S08LN02-WP-B1 2M OMS E2B-S08LN02-WP-B2 2M OMS
NPN E2B-S08LN02-WP-C1 2M OMS E2B-S08LN02-WP-C2 2M OMS
M8 connector
(3-pin)
Short PNP E2B-S08KN02-MC-B1 OMS E2B-S08KN02-MC-B2 OMS
NPN E2B-S08KN02-MC-C1 OMS E2B-S08KN02-MC-C2 OMS
Long PNP E2B-S08LN02-MC-B1 OMS E2B-S08LN02-MC-B2 OMS
NPN E2B-S08LN02-MC-C1 OMS E2B-S08LN02-MC-C2 OMS
M12
Shielded 2 mm
Pre-wired
Brass
Short PNP E2B-M12KS02-WP-B1 2M OMS E2B-M12KS02-WP-B2 2M OMS
NPN E2B-M12KS02-WP-C1 2M OMS E2B-M12KS02-WP-C2 2M OMS
Long PNP E2B-M12LS02-WP-B1 2M OMS E2B-M12LS02-WP-B2 2M OMS
NPN E2B-M12LS02-WP-C1 2M OMS E2B-M12LS02-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M12KS02-M1-B1 OMS E2B-M12KS02-M1-B2 OMS
NPN E2B-M12KS02-M1-C1 OMS E2B-M12KS02-M1-C2 OMS
Long PNP E2B-M12LS02-M1-B1 OMS E2B-M12LS02-M1-B2 OMS
NPN E2B-M12LS02-M1-C1 OMS E2B-M12LS02-M1-C2 OMS
Non-
Shielded 5mm
Pre-wired
Short PNP E2B-M12KN05-WP-B1 2M OMS E2B-M12KN05-WP-B2 2M OMS
NPN E2B-M12KN05-WP-C1 2M OMS E2B-M12KN05-WP-C2 2M OMS
Long PNP E2B-M12LN05-WP-B1 2M OMS E2B-M12LN05-WP-B2 2M OMS
NPN E2B-M12LN05-WP-C1 2M OMS E2B-M12LN05-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M12KN05-M1-B1 OMS E2B-M12KN05-M1-B2 OMS
NPN E2B-M12KN05-M1-C1 OMS E2B-M12KN05-M1-C2 OMS
Long PNP E2B-M12LN05-M1-B1 OMS E2B-M12LN05-M1-B2 OMS
NPN E2B-M12LN05-M1-C1 OMS E2B-M12LN05-M1-C2 OMS
3E2B
Accessories (Order separately)
Sensors cables
M18
Shielded 5 mm
Pre-wired
Brass
Short PNP E2B-M18KS05-WP-B1 2M OMS E2B-M18KS05-WP-B2 2M OMS
NPN E2B-M18KS05-WP-C1 2M OMS E2B-M18KS05-WP-C2 2M OMS
Long PNP E2B-M18LS05-WP-B1 2M OMS E2B-M18LS05-WP-B2 2M OMS
NPN E2B-M18LS05-WP-C1 2M OMS E2B-M18LS05-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M18KS05-M1-B1 OMS E2B-M18KS05-M1-B2 OMS
NPN E2B-M18KS05-M1-C1 OMS E2B-M18KS05-M1-C2 OMS
Long PNP E2B-M18LS05-M1-B1 OMS E2B-M18LS05-M1-B2 OMS
NPN E2B-M18LS05-M1-C1 OMS E2B-M18LS05-M1-C2 OMS
Non-
Shielded 10 mm
Pre-wired
Short PNP E2B-M18KN10-WP-B1 2M OMS E2B-M18KN10-WP-B2 2M OMS
NPN E2B-M18KN10-WP-C1 2M OMS E2B-M18KN10-WP-C2 2M OMS
Long PNP E2B-M18LN10-WP-B1 2M OMS E2B-M18LN10-WP-B2 2M OMS
NPN E2B-M18LN10-WP-C1 2M OMS E2B-M18LN10-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M18KN10-M1-B1 OMS E2B-M18KN10-M1-B2 OMS
NPN E2B-M18KN10-M1-C1 OMS E2B-M18KN10-M1-C2 OMS
Long PNP E2B-M18LN10-M1-B1 OMS E2B-M18LN10-M1-B2 OMS
NPN E2B-M18LN10-M1-C1 OMS E2B-M18LN10-M1-C2 OMS
M30
Shielded 10 mm
Pre-wired
Brass
Short PNP E2B-M30KS10-WP-B1 2M OMS E2B-M30KS10-WP-B2 2M OMS
NPN E2B-M30KS10-WP-C1 2M OMS E2B-M30KS10-WP-C2 2M OMS
Long PNP E2B-M30LS10-WP-B1 2M OMS E2B-M30LS10-WP-B2 2M OMS
NPN E2B-M30LS10-WP-C1 2M OMS E2B-M30LS10-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M30KS10-M1-B1 OMS E2B-M30KS10-M1-B2 OMS
NPN E2B-M30KS10-M1-C1 OMS E2B-M30KS10-M1-C2 OMS
Long PNP E2B-M30LS10-M1-B1 OMS E2B-M30LS10-M1-B2 OMS
NPN E2B-M30LS10-M1-C1 OMS E2B-M30LS10-M1-C2 OMS
Non-
Shielded 20 mm
Pre-wired
Short PNP E2B-M30KN20-WP-B1 2M OMS E2B-M30KN20-WP-B2 2M OMS
NPN E2B-M30KN20-WP-C1 2M OMS E2B-M30KN20-WP-C2 2M OMS
Long PNP E2B-M30LN20-WP-B1 2M OMS E2B-M30LN20-WP-B2 2M OMS
NPN E2B-M30LN20-WP-C1 2M OMS E2B-M30LN20-WP-C2 2M OMS
M12 connector
(4-pin)
Short PNP E2B-M30KN20-M1-B1 OMS E2B-M30KN20-M1-B2 OMS
NPN E2B-M30KN20-M1-C1 OMS E2B-M30KN20-M1-C2 OMS
Long PNP E2B-M30LN20-M1-B1 OMS E2B-M30LN20-M1-B2 OMS
NPN E2B-M30LN20-M1-C1 OMS E2B-M30LN20-M1-C2 OMS
Size Type Features Material Order codes
Nut Cable Straight Angled
M8
Brass (CuZn)
PVC 2 m XS3F-M8PVC3S2M-EU XS3F-M8PVC3A2M-EU
PVC 5 m XS3F-M8PVC3S5M-EU XS3F-M8PVC3A5M-EU
PVC 2 m XS3F-LM8PVC3S2M XS3F-LM8PVC3A2M
3-pin PVC 5 m XS3F-LM8PVC3S5M XS3F-LM8PVC3A5M
M12
PVC 2 m XS2F-M12PVC4S2M-EU XS2F-M12PVC4A2M-EU
PVC 5 m XS2F-M12PVC4S5M-EU XS2F-M12PVC4A5M-EU
PVC 2 m XS2F-LM12PVC4S2M XS2F-LM12PVC4A2M
4-pin PVC 5 m XS2F-LM12PVC4S5M XS2F-LM12PVC4A5M
Size Sensing
distance Connection Body
material
Body
length Output Operation mode NO Operation mode NC
4Inductive Sensors
Connectivity
The E2B sensors are available with the following connectors and cable materials:
Pre-wired models
Standard cable lengths are 2 m and 5 m.
Standard cable material: PVC (dia 4 mm)-WP
Connector models
Standard connectors: M12, M8 (4 pin) -MC
Model number legend
Example: E2B-M12LS04-M1-B1 Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO
E2B-S08KN04-WP-B1 5M Standard, M8 stainless steel, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO,
cable length=5 m
1. Basic name
E2B
2. Housing shape and material
M: Cylindrical, metric threaded, brass
S: Cylindrical, metric threaded, stainless steel
3. Housing size
08: 8 mm
12: 12 mm
18: 18 mm
30: 30 mm
4. Barrel length
K: Standard length
L: Long body
5. Shield
S: Shielded
N: Non-shielded
6. Sensing distance
Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm
7. Kind of connection
WP: pre-wired, PVC, dia 4mm (standard)
M1: M12 connector (4 pin)
MC: M8 connector (3 pin)
8. Power source and output
B: DC, 3-wire, PNP open collector
C: DC, 3-wire, NPN open collector
9. Operation mode
1: Normally open (NO)
2: Normally closed (NC)
10.Cable length
Blank: Connector type
Numeral: Cable length
234 5 6 7 89 101
E2B-@@@@@-@-@@-@
5E2B
Specifications
Double sensing distance, DC 3-wire models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
Size M8 M12
Type Shielded Non-shielded Shielded Non-shielded
Item E2B-S08KS02-__-B1
E2B-S08KS02-__-C1
E2B-S08KN04-__-B1
E2B-S08KN04-__-C1
E2B-M12KS04-__-B1
E2B-M12KS04-__-C1
E2B-M12KN08-__-B1
E2B-M12KN08-__-C1
Sensing distance 2 mm 4 mm 4 mm 8 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 8 × 8 × 1 mm 12 × 12 × 1 mm 12 × 12 × 1 mm 24 × 24 × 1 mm
Response frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type B models: PNP open collector, C models: NPN open collector
Control output Load current 200 mA max. (30 VDC max.)
Indicator Round visible LED indicator for cable type sensors.
Operation mode B1/-C1 models: NO; B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection,
Ambient air temperature Operating & Storage: –25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of –25 to 70°C
Ambient humidity Operating and Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance M8: 500 m/s², 10 times each in X, Y and Z directions
M12-M30: 1,000 m/s², 10 times each in X, Y and Z directions
Standards and listing IP67 after IEC 60529
EMC after EN60947-5-2
Connection method (1) Pre-wired models (standard is dia 4.0 mm PVC with length = 2 m, 5 m)
(2) Connector models (Head M8: M8-3pin, Head M12-M30: M12-4Pin)
Material
Case Stainless steel Brass-nickel plated
Sensing surface PBT
Cable Standard cable is PVC dia 4 mm.
Weight
(packaged)
Pre-wired models Approx. 85 g
Connector models Approx. 35 g
6Inductive Sensors
Double sensing distance, DC 3-wire models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded
Item E2B-M18KS08-__-B1
E2B-M18KS08-__-C1
E2B-M18KN16-__-B1
E2B-M18KN16-__-C1
E2B-M30KS15-__-B1
E2B-M30KS15-__-C1
E2B-M30LN30-__-B1
E2B-M30LN30-__-C1
Sensing distance 8 mm 16 mm 15 mm 30 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 24 × 24 × 1 mm 48 × 48 × 1 mm 45 × 45 × 1 mm 90 × 90 × 1 mm
Response frequency (See note 1.) 500 Hz 400 Hz 250 Hz 100 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type B models: PNP open collector, C models: NPN open collector
Control output Load current 200 mA max. (30 VDC max.)
Indicator Round visible LED indicator for cable type sensors.
Operation mode B1/-C1 models: NO; B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection,
Ambient air temperature Operating & Storage: –25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of –25 to 70°C
Ambient humidity Operating and Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance M8: 500 m/s², 10 times each in X, Y and Z directions
M12-M30: 1000 m/s², 10 times each in X, Y and Z directions
Standards and listing IP67 after IEC 60529
EMC after EN60947-5-2
Connection method (1) Pre-wired models (standard is dia 4.0 mm PVC with length = 2 m, 5 m)
(2) Connector models (Head M8: M8-3pin, Head M12-M30: M12-4Pin)
Material
Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is PVC dia 4 mm.
Weight
(packaged)
Pre-wired models Approx. 85 g
Connector models Approx. 35 g
7E2B
Single sensing distance, DC 3-wire models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
Size M8 M12
Type Shielded Non-shielded Shielded Non-shielded
Item E2B-S08KS01-__-B1
E2B-S08KS01-__-C1
E2B-S08KN02-__-B1
E2B-S08KN02-__-C1
E2B-M12KS02-__-B1
E2B-M12KS02-__-C1
E2B-M12KN05-__-B1
E2B-M12KN05-__-C1
Sensing distance 1 mm 2 mm 2 mm 5 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 8 × 8 × 1 mm 12 × 12 × 1 mm 12 × 12 × 1 mm 24 × 24 × 1 mm
Response frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type B models: PNP open collector, C models: NPN open collector
Control output Load current 200 mA max. (30 VDC max.)
Indicator Round visible LED indicator for cable type sensors.
Operation mode B1/-C1 models: NO; B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection
Ambient air temperature Operating & Storage: 25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C
Ambient humidity Operating and Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance M8: 500 m/s², 10 times each in X, Y and Z directions
M12-M30: 1000 m/s², 10 times each in X, Y and Z directions
Standards and listing IP67 after IEC 60529
EMC after EN60947-5-2
Connection method (1) Pre-wired models (standard is dia 4.0 mm PVC with length = 2 m,5 m)
(2) Connector models (Head M8: M8-3pin, Head M12-M30: M12-4Pin)
Material
Case Stainless steel Brass-nickel plated
Sensing surface PBT
Cable Standard cable is PVC dia 4 mm.
Weight
(packaged)
Pre-wired models Approx. 65 g
Connector models Approx. 15 g
8Inductive Sensors
Single sensing distance, DC 3-wire models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
Size M18 M30
Type Shielded Non-shielded Shielded Non-shielded
Item E2B-M18KS05-__-B1
E2B-M18KS05-__-C1
E2B-M18KN10-__-B1
E2B-M18KN10-__-C1
E2B-M30KS10-__-B1
E2B-M30KS10-__-C1
E2B-M30LN20-__-B1
E2B-M30LN20-__-C1
Sensing distance 5 mm 10 mm 10 mm 20 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 24 × 24 × 1 mm 48 × 48 × 1 mm 45 × 45 × 1 mm 90 × 90 × 1 mm
Response frequency (See note 1.) 500 Hz 400 Hz 250 Hz 100 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type B models: PNP open collector, C models: NPN open collector
Control output Load current 200 mA max. (30 VDC max.)
Indicator Round visible LED indicator for cable type sensors.
Operation mode B1/-C1 models: NO; B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection,
Ambient air temperature Operating & Storage: 25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C
Ambient humidity Operating and Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance M8: 500 m/s², 10 times each in X, Y and Z directions
M12-M30: 1000 m/s², 10 times each in X, Y and Z directions
Standards and listing IP67 after IEC 60529
EMC after EN60947-5-2
Connection method (1) Pre-wired models (standard is dia 4.0 mm PVC with length = 2 m,5 m)
(2) Connector models (Head M8: M8-3pin, Head M12-M30: M12-4Pin)
Material
Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is PVC dia 4 mm.
Weight
(packaged)
Pre-wired models Approx. 65 g
Connector models Approx. 20 g
9E2B
Engineering data (Reference value)
Operating range Influence of sensing object size and materials
M8 Shielded models Non-shielded models
M12 Shielded models Non-shielded models
Sensing distance X (mm)
E2B-S08
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
Distance Y (mm)
X
Y
8 –6 –4 –2 0 2 4 6 8
E2B-S08@S01
E2B-S08@N02
E2B-S08@N04
E2B-S08@S02
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@S01
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@N02
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25 30
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@S02
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25
3
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@N04
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70
6
5
4
3
2
1
E2B-M12@S04
E2B-M12@S02
E2B-M12@N05
Sensing distance X (mm)
E2B-M12
9
8
7
6
5
4
3
2
1
0
Distance Y (mm)
X
Y
–16 –12 8 –4 0 4 8 12 16
E2B-M12@N08
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M12@S02
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M12@N05
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
6
5
4
3
2
1
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M12@S04
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25 30 35
5
4
3
2
1
Brass
Copper
Iron
Aluminium
t = 1
mm
X
@d
E2B-M12@N08
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
9
8
7
6
5
4
3
2
1
Stainless steel (SUS304)
10 Inductive Sensors
M18 Shielded models Non-shielded models
M30 Shielded models Non-shielded models
Operating range Influence of sensing object size and materials
Distance Y (mm)
Sensing distance X (mm)
E2B-M18
18
16
14
12
10
8
6
4
2
0
X
Y
30 –20 –10 0 10 20 30
E2B-M18@S05
E2B-M18@S08
E2B-M18@N16
E2B-M18@N10
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@S05
Sensing distance X (mm)
Side length of sensing object d (mm)
6
5
4
3
2
1
0 10 20 30 40 50 60 70 80 90
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@N10
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
12
10
8
6
4
2
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@S08
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
9
8
7
6
5
4
3
2
1
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@N16
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
18
16
14
12
10
8
6
4
2
Sensing distance X (mm)
E2B-M30
35
30
25
20
15
10
5
0
Distance Y (mm)
X
Y
–60 –40 -20 0 20 40 60
E2B-M30@S15
E2B-M30@S10
E2B-M30@N30
E2B-M30@N20
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30@S10
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70
12
10
8
6
4
2
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30@N20
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90 100
25
20
15
10
5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30@S15
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90 100
20
16
12
8
4
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30LN30
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90 100
35
30
25
20
15
10
5
11E2B
Operation
DC 3-wire models
PNP Output
Operation mode Model Timing chart Output circuit
NO E2B-@-@-B1
NC E2B-@-@-B2
Sensing
object
(%) 100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
main
circuit
RL
Brown
Black
Blue
10 to 32 VDC
load current: 200 mA max
3
1
243
1
4
M12 connector
Pin Arrangement M8 connector (3 pin)
Pin Arrangement
Pin 2 of the M12 connector is not used.
: NC
: NO
(%) 100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
main
circuit
RL
Brown
Black
Blue
10 to 32 VDC
load current: 200 mA max
3
1
243
1
4
M12 connector
Pin Arrangement M8 connector (3 pin)
Pin Arrangement
Pin 4 of the M12 connector is not used.
: NC
: NO
12 Inductive Sensors
DC 3-wire models
NPN Output
Operation mode Model Timing chart Output circuit
NO E2B-@-@-C1
NC E2B-@-@-C2
Sensing
object
(%) 100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
RL
Brown
Black
OR
Blue
10 to 32 VDC
: NC
: NO
load current: 200 mA max
main
circuit
Pin 2 of the M12 connector is not used.
3
1
24
M12 connector
Pin Arrangement
3
1
4
M8 connector (3 pin)
Pin Arrangement
(%) 100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
RL
Brown
Black
OR
Blue
10 to 32 VDC
: NC
: NO
load current: 200 mA max
main
circuit
Pin 4 of the M12 connector is not used.
3
1
24
M12 connector
Pin Arrangement
3
1
4
M8 connector (3 pin)
Pin Arrangement
13E2B
Dimensions
M8 size
Pre-wired models (Shielded)
Short body
Pre-wired models (Non-shielded)
Long body
Connector models (Shielded)
Short body
Connector models (Non-shielded)
Long body
M8×1
Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
13
27
4
42
M8×1
Operating indicator
(yellow LED,4×90°)
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
627
4
42
6.6 dia.
13
M8×1
Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
13
49
4
64
M8×1
Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
13
6.6 dia.
49
4
64
6
M8×1 Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
M8×1
27
4
44
13
13
M8×1
Two,clamping nuts
M8×1
Operating indicator
(yellow LED,4×90°)
6
44
27
4
6.6 dia.
M8×1
Operating indicator
(yellow LED,4×90°)
Two,clamping nuts
M8×1
13
49
4
66
M8×1
Operating indicator
(yellow LED,4×90°)
Two,clamping nuts
M8×1
13
49
4
66
6
6.6 dia.
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M8
GF
8.5 dia.
+0.5
0
13
14 Inductive Sensors
M12 size
Pre-wired models (Shielded)
Short body
Pre-wired models (Non-shielded)
Long body
Connector models (Shielded)
Short body
Connector models (Non-shielded)
Long body
17 Operating indicator
(yellow)
307.9
47
4
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
17 7
307.9
47
4
10.5 dia.
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
Operating indicator
(yellow)
17 Operating indicator
(yellow)
537.9
70
4
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
17 Operating indicator
(yellow)
7
537.9
70
4
10.5 dia.
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
M12×1
M12×1
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
31
51
4
17
M12×1
M12×1
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
7
31
51
4
17
10.5 dia.
17
M12×1
M12×1
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
54
74
4
17
M12×1 M12×1
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
7
54
74
4
10.5 dia.
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M12
GF
12.5 dia.
+0.5
0
17
15E2B
M18 size
Pre-wired models (Shielded)
Short body
Pre-wired models (Non-shielded)
Long body
Connector models (Shielded)
Short body
Connector models (Non-shielded)
Long body
24
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Operating indicator
(yellow)
36 5.6
56
4
M18×1
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
24 Operating indicator
(yellow)
10
36 5.6
56
4
16.4 dia.
M18×1
Two,clamping nuts
24
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Operating indicator
(yellow)
585.6
78
4
M18×1
Two,clamping nuts
24
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Operating indicator
(yellow)
10
585.6
78
4
16.4 dia.
M18×1
Two,clamping nuts
24
M12×1
M18×1
Two,clamping nuts
10
39
59
4Operating indicator
(yellow LED 4×90°)
M12×1
M18×1
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
10
39
59
4
24
16.4 dia.
24
M12×1
M18×1
Two,clamping nuts
61
81
4Operating indicator
(yellow LED 4×90°)
24
M12×1
M18×1
Two,clamping nuts
10
61
81
4Operating indicator
(yellow LED 4×90°)
16.4 dia.
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M18
GF
18.5 dia.
+0.5
0
24
16 Inductive Sensors
M30 size
Pre-wired models (Shielded)
Short body
Pre-wired models (Non-shielded)
Long body
Connector models (Shielded)
Short body
Connector models (Non-shielded)
Long body
36
M30×1.5
Two,clamping nuts
Operating indicator
(yellow)
41
60
5
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
6.1
M30×1.5
Two,clamping nuts
Operating indicator
(yellow)
15
41
60
5
36
4-dia. vinyl-insulated round cable
with 3 conductors (conductor cross section :
0.141 mm² ; insulator diameter : 0.85 mm) ;
standard length : 2 m
6.1
27.8 dia.
36
M30×1.5
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
63
82
5
6.1
Operating indicator
(yellow)
36
M30×1.5
Two,clamping nuts
Operating indicator
(yellow)
15
63
82
5
4-dia. vinyl-insulated round cable
with 3 conductors (conductor cross section :
0.141 mm² ; insulator diameter : 0.85 mm) ;
standard length : 2 m
6.1
27.8 dia.
M12×1
M30×1.5
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
44
64
5
36
M12×1
M30×1.5
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
15
44
64
5
36
27.8 dia.
M12×1
M30×1.5
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
36
66
86
5
M12×1
M30×1.5
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
36
15
66
86
5
27.8 dia.
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M30
GF
30.5 dia.
+0.5
0
36
17E2B
Accessories (Order separately)
Sensor I/O connectors
M8 connector (3 pin)
PVC type (Unit: mm)
Pin arrangement
Sensor I/O connectors
M12 connector (4 pin)
PVC type
Pin arrangement
1-Brown
3-Blue
4-Black
1-Brown
2-White
3-Blue
4-Black
13
4
9 dia.
50
305
31.9
L (Cable length)
21.5
5 dia.
M8×1
Straight
XS3F-M8PVC3S2M-EU (L = 2 m)
XS3F-M8PVC3S5M-EU (L = 5 m)
XS3F-LM8PVC3S2M (L = 2 m)
XS3F-LM8PVC3S5M (L = 5 m)
1
3
4
9 dia.
21
50
305
23.1
L (Cable length)
M8×1
5 dia.
Right-angle
XS3F-M8PVC3A2M-EU (L = 2 m)
XS3F-M8PVC3A5M-EU (L = 5 m)
XS3F-LM8PVC3A2M (L = 2 m)
XS3F-LM8PVC3A5M (L = 5 m)
31
4
Straight
XS2F-M12PVC4S2M-EU (L = 2 m)
XS2F-M12PVC4S5M-EU (L = 5 m)
XS2F-LM12PVC4S2M (L = 2 m)
XS2F-LM12PVC4S5M (L = 5 m)
14.9 dia.
50
30 5
40.7
L (Cable length)
1
3
2
4
5 dia.
M12×1
Right-angle
XS2F-M12PVC4A2M-EU (L = 2 m)
XS2F-M12PVC4A5M-EU (L = 5 m)
XS2F-LM12PVC4A2M (L = 2 m)
XS2F-LM12PVC4A5M (L = 5 m)
14.9 dia.
28.3
50
30
32.1
L (Cable length)
1
3
24
5
5 dia.
M12×1
2
1
4
3
18 Inductive Sensors
Precautions
This product is not designed or rated for ensuring
safety of persons. Do not use it for such purpose.
Never use this product with an AC power supply.
Otherwise, explosion may result.
Safety precautions
Load short-circuit
Do not short-circuit the load, or the E2B may be damaged.
The E2B’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
Wiring
Be sure to wire the E2B and load correctly, otherwise it may be dam-
aged.
Connection with no load
Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2B in operation, otherwise it may damage internal ele-
ments.
Do not expose the product to flammable or explosive gases.
Do not disassemble, repair, or modify the product.
Correct use
Designing
Power reset time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sen-
sor before supplying power to the load.
Effects of surrounding metal
When mounting the proximity sensor within a metal panel, ensure
that the clearances given in the Table1 are maintained. Failure to
maintain these distance may cause deterioration in the performance
of the sensor.
Table 1
Single sensing distance type
<Shielded>
(Unit: mm)
<Non-shielded>
(Unit: mm)
Double sensing distance type
<Shielded>
(Unit: mm)
<Non-shielded>
(Unit: mm)
WARNING
Item Size
M8 M12 M18 M30
l0000
d8121830
D0000
m4.5 8 20 40
n12 18 27 45
l
m
n
m
D
d dia.
l
Item Size
M8 M12 M18 M30
l6 152230
d24 40 55 90
D6 152230
m8 204070
n24 36 54 90
l
m
n
m
D
d dia.
l
Item Size
M8 M12 M18 M30
l02.43.66
d8182745
D02.43.66
m4.5 12 24 45
n12 18 27 45
l
m
n
m
D
d dia.
l
Item Size
M8 M12 M18 M30
l12 15 25 45
d24 40 70 140
D12 15 25 45
m8 204890
n24 40 70 140
l
m
n
m
D
d dia.
l
19E2B
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power supply transformer
When using a DC power supply, make sure that the DC power supply
has an insulated transformer. Do not use a DC power supply with an
auto-transformer.
Mutual interference
When installing two or more proximity sensors face to face or side by
side, ensure that the minimum distances given in the Table2 are
maintained.
Table 2 Unit: (mm)
Wiring
High-tension lines
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to pre-
vent against Proximity Sensor damage or malfunctioning.
Cable extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
Mounting
Do not tighten the sensor mounting nuts with excessive force.
Maintenance and inspection
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, looseness, or distortion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environ-
mental conditions.
5. Check for proper lighting of indicators (for models with a set indi-
cator.)
Never disassemble or repair the Sensor.
Environment
Water resistivity
The Proximity Sensors are tested intensively on water resistance, but
in order to ensure maximum performance and life expectancy avoid
immersion in water and provide protection from rain or snow.
Operating environment
Ensure storage and operation of the Proximity Sensor within the
given specifications.
Inrush current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
<SUITABILITY FOR USE>
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the cus-
tomer’s application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
<CHANGE IN SPECIFICATIONS>
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON
representative at any time to confirm actual specifications of purchased product.
Size M8 M12 M18 M30
Type Shielded Non-shielded Shielded Non-shielded Shielded Non-shielded Shielded Non-shielded
Model
E2B-( )
S08
@
S01 S08
@
S02 S08
@
N02 S08
@
N04 M12
@
S02 M12
@
S04 M12
@
N05 M12
@
N08 M18
@
S05 M18
@
S08 M18
@
N10 M18
@
N16 M30
@
S10 M30
@
S15 M30
@
N20 M30
@
N30
A20 20 80 80 30 30 120 120 50 60 200 200 100 110 300 350
B15 15 60 60 20 20 100 100 35 35 110 120 70 90 200 300
(Shielded) (Non-shielded)
Table 3
Size Torque
M8 7 N·m
M12 12 N·m
M18 30 N·m
M30 50 N·m
20 Inductive Sensors
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND
SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated
products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the
product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by
itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is
it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations
subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS
BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of
the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request.
Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading
errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner,
for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. D17E-EN-03A