First Sensor APD Data Sheet Part Description AD500-10 TO Order # 3001157 Features * o 500 m active area * High QE for = 850-1064 nm * Low noise * Low slope multiplication curve Description Application RoHS Circular active area APD chip with IR enhanced sensitivity. Very low dark current due to guard ring diode. Metal can type hermetic TO5i package with clear glass window. * Pulsed 1064 nm laser detection * Laser range finding * Fluorescence detection 2011/65/EU Absolute maximum ratings Parameter Storage temp Operating temp Gain (IP0 = 1 nA) Peak DC current Spectral response (M = 100; 23 C) Min -55 -40* 1000 Max 125 100 Unit C C 0.25 mA PIN 1 GR 60 50 Schematic PIN 2 70 Responsivity (A/W) Symbol TSTG TOP Mmax IPEAK 40 30 20 10 PIN 3 0 500 600 700 800 900 1000 1100 Wavelength (nm) PIN 4 Electro-optical characteristics @ 23 C Symbol ID C tR tR VBR Characteristic Active area Active area Dark current Capacitance Responsivity Responsivity Rise time Cut-off frequency Breakdown voltage Temperature coefficient Rev. 05/02/2018 Test Condition M = 100 M = 100 M = 100; = 905 nm M = 100; = 1064 nm M = 100; = 1064 nm; RL = 50 -3dB IR = 2 A subject to change without notice www.first-sensor.com Min 220 Typ o 500 0.2 1.5 0.5 59 49 4 90 300 3.3 Max 10 600 contact@first-sensor.com Unit m mm nA pF A/W A/W ns MHz V V/K Page 1/2 ata Sheet First Sensor APD Data Sheet D500-10 TO # 3001157 Part Description AD500-10 TO Order # 3001157 Quantum efficiency (23 C) Capacitance as fct of reverse bias (23 C) 100 8 6 Capacitance (pF) Quantum efficiency (%) 7 80 60 40 20 5 4 3 2 1 0 0 500 600 700 800 900 1000 1100 0 20 Wavelength (nm) Multiplication as fct of reverse bias 60 80 100 Dark current as fct of reverse bias 1000 Dark current per element (A) 1,0E-07 100 Multiplication 40 Reverse bias (V) 23C 10 40C 60C 1 1,0E-08 1,0E-09 23C 40C 1,0E-10 60C 1,0E-11 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 Reverse bias (V) Reverse bias (V) Application hints: * Current should be limited by a protecting resistor or current limiting - IC inside the power supply * Guard ring should be connected to ground * For low light level applications blocking of ambient light should be used * For high gain applications bias voltage should be temperature compensated * Please consider basic ESD protection while handling * Use low noise read-out - IC * For further questions please refer to document "Instructions for handling and processing" and application notes for APDs and APD-Arrays Package dimension: Small quantities: Foam pad, boxed (12 cm x 16.5 cm) Rev. 05/02/2018 subject to change without notice www.first-sensor.com contact@first-sensor.com Page 2/2 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: First Sensor: AD100-10-TO5I AD500-10 3001157