Click on Series name for product info on aimtec.com Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver FEATURES: * * * * * AC-DC Constant current LED Driver Input range 90-277VAC/47-440Hz High Efficiency up to 89% Operating temperature -40 to 80C Dimmable via analog / 0-10Vdc / PWM (C version see table) * * * * * Over Temperature Protection Open frame Power Factor Correction SCP, Over Current Protection 5 Years Limited Warranty Models Single output Model Max Output Power (W) * Output Voltage Range (V) AMEOR60-50120AZ AMEOR60-36170AZ AMEOR60-24250AZ AMEOR60-12500AZ 60 59.8 60 60 36-50 24-36 12-24 5-12 Output Current (A) Input Voltage (VAC/Hz) Input Voltage (VDC) Efficiency (%) 90-277/47-440 90-277/47-440 90-277/47-440 90-277/47-440 130-390 130-390 130-390 130-390 89 88 87 85 1.2 1.66 2.5 5 *Exceeding the maximum output power will permanently damage the converter All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add "-NA" to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMEOR60-AZ's AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to `dirty' electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Inrush current <2ms Leakage current AC current Power Factor External fuse Start up time Surge voltage Conditions Typical 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 30 50 0.5 0.75 0.67 0.33 Maximum Units A mA A 0.99 0.97 250V/1.5A 250 2sec 440 ms V Maximum Units Output Specifications Parameters Current accuracy Line regulation Load regulation Ripple & Noise * Hold-up time Current adjustment range Minimum Load Voltage www.aimtec.com F 052.1e R3.L Conditions Typical 3 1 3 75 90 100-0 LL-HL 0-100% load 20MHz Bandwidth % % % mV p-p ms % See the models table Tel: +1 514 620 2722 1 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver * Tested with 0.1F (M/C) or (C/C) and 10F (E/C) parallel capacitors at the end. Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance Typical 3 sec/3.5mA Rated Units 3000 VAC M >1000 General Specifications Parameters Conditions Typical Switching frequency Maximum 130 Over current protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Wires Weight Dimensions (L X H X W) MTBF KHz AMEOR60-50120AZ AMEOR60-36170AZ AMEOR60-24250AZ AMEOR60-12500AZ Refer to Constant Current vs. Constant Voltage Mode curve Continuous Auto recovery >105C With derating over 60C -40 to +80 1.27 1.77 2.55 5.2 A oC 100 oC oC -40 to +95 0.02 Free air convection % / oC 95 UL1015 18AWG * 20CM 220 5.83 x 1.97 x 1.3 inches 148 x 50 x 33 mm >400,000 hrs (MIL-HDBK-217F at +25C) Units % RH g Environment Approval Test Shock Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.L CE Designed to meet UL8750, IEC/EN 60950-1 standards, EN55022, class B Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver Dimensions Top View 148.00 (5.83) 139.00 (5.47) 4.50 (0.18) 4.50 (0.18) 50.00 (1.97) 41.00 (1.61) 4 Mounting Holes-M3 5.00 (0.20) 28.00 (1.10) 200.00 (8.00) Side View 200.00 (8.00) Input/Output Wires are 18 AWG 20cm NOTE: to adjust the output current connect a 20K Ohm pot between blue and white wire Wire connection: Connection Wire Brown Blue Green Red Black Blue (Dimming) White (Dimming) AC L AC N Ground +V output -V Output + Vs dimming -Vs dimming AMEOR60-AZ Analog (resistive) Dimming Application Circuit BROWN L GREEN +Vout RED Model Number 1st LED 1 AC AMEPR60-AZ BLUE -Vout N 1 BLUE WHITE www.aimtec.com F 052.1e R3.L BLACK AMEPR60-50120AZ AMEPR60-36170AZ AMEPR60-24250AZ AMEPR60-12500AZ Maximum Pot Value (k) 26.00 16.95 26.10 34.10 Pot Tel: +1 514 620 2722 3 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver AMEOR60-AZ Analog (0-10V) Dimming Application Circuit AMEOR60-AZ PWM (1KHz) Dimming Application Circuit Temperature graph www.aimtec.com F 052.1e R3.L Tel: +1 514 620 2722 4 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver Free Air Convection 60 C Output Power (%) 100 80 Safe Operating Area 60 40 30 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature C Efficiency Vs. Input Voltage & Output Current (Constant current load) AMEOR60-50120AZ (%) Efficiency Vs. Input Voltage & Output Current 110Vac, 0.24, 81.4 230Vac, 1.2, 110Vac 88.01.2,230Vac 110Vac, 87.9 230Vac, 0.24, 74.0 (A) AMEOR60-36170AZ www.aimtec.com F 052.1e R3.L Tel: +1 514 620 2722 5 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver (%) Efficiency Vs. Input Voltage & Output Current 110Vac, 0.34, 81.4 230Vac,110Vac 1.7, 88.01.7, 110Vac, 230Vac 87.9 230Vac, 0.34, 74.6 (A) www.aimtec.com F 052.1e R3.L Tel: +1 514 620 2722 6 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver Efficiency Vs. Input Voltage & Output Current (Constant current load) Continued AMEOR60-24250AZ (%) Efficiency Vs. Input Voltage & Output Current 110Vac, 0.5, 81.7 230Vac, 2.5, 110Vac 87.0 230Vac 110Vac, 2.5, 85.4 230Vac, 0.5, 78.1 (A) AMEOR60-12500AZ (%) Efficiency Vs. Input Voltage & Output Current 230Vac, 5, 110Vac 84.9 110Vac, 5,230Vac 83.9 110Vac, 1, 73.4 230Vac, 1, 72.9 www.aimtec.com F 052.1e R3.L (A) Tel: +1 514 620 2722 7 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver PFC Value vs. Output Load Current (constant current mode) AMEOR60-50120AZ PFC value Vs. Output Load Current (value) 115VAC, 50%, 0.98 115VAC, 115VAC 100%, 1.00 230VAC 230VAC, 100%, 0.96 230VAC, 50%, 0.91 (load) AMEOR60-36170AZ PFC value Vs. Output Load Current (value) 115VAC, 50%, 0.98 115VAC, 115VAC 100%, 0.99230VAC 230VAC, 100%, 0.96 230VAC, 50%, 0.88 www.aimtec.com F 052.1e R3.L (load) Tel: +1 514 620 2722 8 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver PFC Value vs. Output Load Current (constant current mode) Continued AMEOR60-24250AZ PFC value Vs. Output Load Current (value) 115VAC, 50%, 0.98 230VAC, 50%, 0.77 115VAC, 115VAC 100%, 1.00230VAC 230VAC, 100%, 0.94 (load) AMEOR60-12500AZ www.aimtec.com F 052.1e R3.L Tel: +1 514 620 2722 9 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver Constant Current vs. Constant Voltage Mode AMEOR60-50120AZ (A) Constant Current Vs. Constant Voltage Normal Input, 50, 1.22 Normal Input, 36, 1.21 36 38 40 Normal Input, Normal Input, 50.4, 0.00 52, 0.00 (V) AMEOR60-36170AZ (A) Constant Current Vs. Constant Voltage Normal Input, 24, 1.71 Normal Input, 36, 1.73 24 26 28 Normal Input, Normal Input, 36.4, 0.00 38, 0.00 (V) www.aimtec.com F 052.1e R3.L Tel: +1 514 620 2722 10 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver Constant Current vs. Constant Voltage Mode Continued AMEOR60-24250AZ (A) Constant Current Vs. Constant Voltage Normal Input, 12, 2.51 Normal Input, 24, 2.53 12 14 16 Normal Input, Normal Input, 24.5, 0.00 26, 0.00 (V) AMEOR60-12500AZ (A) Constant Current Vs. Constant Voltage Normal Input, 5, 5.04 Normal Input, 12, 5.02 5 6 7 Normal Input, Normal Input, 14, 0.00 12.3, 0.00 (V) www.aimtec.com F 052.1e R3.L Tel: +1 514 620 2722 11 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver Dimming Control (Output Current vs. Radj) AMEOR60-50120AZ (A) Output Current vs. Resistance adjustment Normal Input, Normal Input, 4.26 , 90% 1.50 , 80% Normal Input, Normal 0.88 ,Input, 70% Normal 0.45 , Input, 60% Normal 0.25 , Input, 50% Normal 0.15 , Input, 40% Normal 0.10 , Input, 30% Normal Input, 0.02 , 20% Normal Input, 0.01 , 10% 0.007, 0% Normal Input, 0.007 26.00 , 100% 0.01 K() AMEOR60-36170AZ (A) Output Current vs. Resistance adjustment Normal Input, Normal Input, 3.05 , 90% 1.58 , 80% Normal Input, Normal 0.96 ,Input, 70% Normal 0.63 , Input, 60% Normal 0.43 , Input, 50% Normal 0.29 , Input, 40% Normal 0.19 , Input, 30% Normal 0.12 , Input, 20% Normal 0.06 , Input, 10% 0, 0% www.aimtec.com F 052.1e R3.L Normal Input, 0 16.95 , 100% 0.06 K() Tel: +1 514 620 2722 12 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOR60-AZ up to 5A | AC-DC / DC-DC LED driver Constant Current vs. Constant Voltage Mode Continued AMEOR60-24250AZ (A) Output Current vs. Resistance adjustment Normal Input, Normal Input, 4.29 , 90% 1.84 , 80% Normal Input, Normal 0.88 ,Input, 70% Normal 0.50 , Input, 60% Normal 0.35 , Input, 50% Normal 0.11 , Input, 40% Normal Input, 0.00 , 30% Normal Input, 0.00 , 20% Normal Input, 0.00 , 10% 0, 0% Normal Input, 0 26.10 , 100% 0.00 K() AMEOR60-12500AZ (A) Output Current vs. Resistance adjustment Normal Input, Normal Input, 3.74 , 90% 1.54 , 80% Normal Input, Normal 0.60 , Input, 70% Normal 0.30 , Input, 60% Normal Input, 0.06 , 50% Normal Input, 0.03 , 40% Normal Input, 0.01 , 30% Normal Input, 0.00 , 20% Normal Input, 0.00 , 10% 0, 0% Normal Input, 0 34.10 , 100% 0.00 K() NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.L Tel: +1 514 620 2722 13 of 13 Toll free: + 1 888 9 AIMTEC (924 6832) North America only