1 AF50 - AF1650 General information AC & DC operated, UL rated, 3 phase e lin e th rs ss cto o r ta Ac con Application Control circuit types A-Line contactors are mainly used for controlling 3-phase motors and for controlling power circuits corresponding to their operating characteristics up to 690 and even 1000 VAC. and 440 VDC. *AF types: AC/DC operated with laminated magnetic circuit. Contact or types Description of 3 pole contactors AF50 - AF1650 All AF contactors can be assembled side by side. The add-on auxiliary contacts are suitable for low level currents. * 3 pole contactors with 1 NO or 1 NC factory assembled auxiliary contacts for AF50 - AF1650 contactors Quick mounting on DIN rail: EN 50022 and EN 50023 standards: Surge suppressors built in as standard on the printed circuit board. 35 x 15mm for AF50 - AF75 75mm for AF50 - AF110 Clear marking of coil voltages and frequencies. Location of side mounted accessories: on right or left hand side. Factory mounted on left hand side for CAL5 on AF50 - AF1650 A2 A1 Holes for screw mounting (screws not supplied). Distance between holes according to EN 50003. 3 Connecting point for control leads in top part of main terminals of AF50 - AF75 contactors. For AF95 & AF110 contactors these are additional power connections. 5L 2 3L 1 1L Terminal marking according to IEC 947-4-1, EN 50005, EN 50012 and NEMA standards. Location of function marker. Stops for attaching front mounted accessories. UL Terminal screws: Terminals delivered in open position with captive screws (screws of unused terminals must be tightened). * Posidrive (+,-) No 2 for all AF50 - AF75 AF50 - AF1650 Screwdriver guidance for all terminals makes it possible to use motorized screwdrivers. * M8 hex threaded socket screw for AF95 - AF1650 main terminals. All terminals provide protection against accidental direct contact with live parts according to VDE0106 - Part. 100. All AF50- AF110 contactor terminals as well as AF50 - AF1650 contactor auxiliary contact and coil terminals ensure IP20 degree of protection according to IEC 947-1. Catalog number explanation AF50 - 30 - 11 - 70 Frame size Coil voltage (see coil voltage selection chart) Power pole Auxiliary contacts 30 = 3 NO 40 = 4 NO 22 = 2 NO & 2 NC 11 = 1 NO & 1 NC 00 = No auxiliary provided 22 = 2 NO & 2 NC Coil voltage selection - AF50 to AF1650 24 - 60 DC 68 1 20 - 60 DC 72 2 AC/DC VOLTS, 40 - 60 Hz 48 - 130 AC/DC 100 - 250 AC/DC 69 70 3 250 - 500 AC//DC 71 4 1 AF400 - AF750, DC only. 2 AF50 - AF300, DC only. 3 Only option for AF1350 / AF1650. 4 AF400 - AF750 only. 1.8 1SXU000023C0202 Low Voltage Products & Systems Ac AF50 - AF1650 Non-reversing, mechanically interlocked, reversing AC & DC operated, UL rated, 3 phase AF63-30-11-70 AF95-30-11-70 AF400-30-11-70 ro co ss nt the ac to line 1 rs AF750-30-11-70 3 Pole General purpose current UL motor switching Maximum UL Listed current motor horsepower ratings AC1 80 90 105 125 140 230 250 300 350 400 550 650 750 900 1260 1350 1650 2050 54 65 80 95 110 130 156 192 248 302 414 480 602 810 -- 960 1080 -- Standard auxiliary contacts 208V 240V 480V 575/600V NO NC 15 20 25 30 30 40 50 60 75 100 125 150 200 250 -- -- -- -- 20 25 30 30 40 50 60 75 100 100 150 200 250 300 -- 400 450 -- 40 50 60 60 75 100 125 150 200 250 350 400 500 600 -- 800 900 -- 50 60 75 75 100 125 150 200 250 300 400 500 600 700 -- 900 1000 -- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Non-reversing Catalog number AF50-30-11-70 AF63-30-11-70 AF75-30-11-70 AF95-30-11-70 AF110-30-11-70 AF145-30-11-70 AF185-30-11-70 AF210-30-11-70 AF260-30-11-70 AF300-30-11-70 AF400-30-11-70 AF460-30-11-70 AF580-30-11-70 AF750-30-11-70 AF1250-30-11-70 AF1350-30-11-70 AF1650-30-11-70 AF2050-30-11-70 Mechanically interlocked Reversing List price Catalog number List price Catalog number List price $ 450 495 535 570 600 1,110 1,635 1,980 2,235 2,385 3,120 4,425 6,900 7,200 8,120 8,490 10,230 12,820 AF50M-30-11-70 AF63M-30-11-70 AF75M-30-11-70 AF95M-30-11-70 AF110M-30-11-70 AF145M-30-11-70 AF185M-30-11-70 AF210M-30-11-70 AF260M-30-11-70 AF300M-30-11-70 AF400M-30-11-70 AF460M-30-11-70 AF580M-30-11-70 AF750M-30-11-70 -- -- -- -- $ 953 1,116 1,399 1,470 1,605 2,655 3,870 4,545 5,055 6,030 6,705 13,275 18,375 19,725 -- -- -- -- AF50R-30-11-70 AF63R-30-11-70 AF75R-30-11-70 AF95R-30-11-70 AF110R-30-11-70 AF145R-30-11-70 AF185R-30-11-70 AF210R-30-11-70 AF260R-30-11-70 AF300R-30-11-70 AF400R-30-11-70 AF460R-30-11-70 AF580R-30-11-70 AF750R-30-11-70 -- -- -- -- $ 1,050 1,259 1,542 1,665 1,868 2,670 3,375 4,560 5,070 6,045 6,720 13,290 18,390 19,740 -- -- -- -- Coil voltage selection - wide range AC/DC coils All catalog numbers include a 100-250V AC/DC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Ex.: A 24V coil is required for a AF110 contactor: AF110-30-11-72 Coil voltage selection - AF50 to AF1650 24 - 60 DC 68 1 20 - 60 DC 72 2 AC/DC VOLTS, 40 - 60 Hz 48 - 130 AC/DC 100 - 250 AC/DC 69 70 3 250 - 500 AC//DC 71 4 1 AF400 - AF1250, DC only. 2 AF50 - AF300, DC only. 3 Only option for AF1350 - AF2050. 4 AF400 - AF750 only. Low Voltage Products & Systems Discount schedule AA [OA] - AF50 - AF110 Discount schedule AEA [OC] - AF145 - AF2050 1SXU000023C0202 1 A/AF/AL9 - A/AF/AL110 Contactors for ring tongue termination AC & DC operated, UL rated, 3 phase e lin e th rs ss cto o r ta Ac con UL UL Motor UL/CSA horsepower ratings Auxiliary contacts general purpose switching current current 240V 480V 575/600V NO NC AC1 21 9 2 5 7.5 25 11 3 7.5 10 30 17 5 10 15 40 28 10 20 25 80 54 20 40 50 AC operated DC operated Catalog number 1 0 1 0 1 0 1 0 0 0 1 0 1 0 1 0 1 0 A93010RT-84 A93001RT-84 A123010RT-84 A123001RT-84 A163010RT-84 A163001RT-84 A263010RT-84 A263001RT-84 A503000RT-84 List price Catalog number 363 AL93010RT-81 AL93001RT-81 AL123010RT-81 AL123001RT-81 AL163010RT-81 AL163001RT-81 AL263010RT-81 AL263001RT-81 AF503000RT-70 $ 83 90 122 172 List price $ 152 186 207 211 262 582 90 65 25 50 60 0 0 A633000RT-84 417 AF633000RT-70 647 105 80 30 60 75 0 0 A753000RT-84 475 AF753000RT-70 687 125 95 30 60 75 0 0 AF95B3011RT-70 927 AF95B3011RT-70 927 140 110 40 75 100 0 0 AF110B3011RT-70 986 AF110B3011RT-70 986 Coil voltage selection - AC coils All AC operated catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the AC coils Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Ex.: A 240V coil is required for an A75 contactor: A753000RT-80 Coil voltage selection chart - AC coils Cntr Hz type 12 24 48 110 120 125 208 60 A 81 83 84 84 34 50 A 81 83 84 Volts 220 240 277 380 415 440 480 500 600 36 80 42 86 86 51 53 55 80 85 86 55 Coil voltage selection - DC coils For other voltages, see page 1.24. All DC operated catalog numbers include a 24VDC coil. To select other coil voltages, substitute the code from the DC coils Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Coil voltage selection chart - DC coils Ex.: A 110V coil is required for an AE75 contactor: AE753000RT-86 Hz DC Auxiliary contact blocks Contr. Volts type 24 48 110 125 220 240 AE 81 83 86 87 88 89 For other voltages, see page 1.24. For additional auxiliary contact blocks, see catalog number explanation on page 1.2. Add $ 20 to list price for each additional auxiliary, and see page 1.32 for available combinations. Only side-mounted blocks are allowed to be factory installed. Auxiliary contact block with ring tongue termination Positioning Maximum number of contact blocks Front mounting 1 block (C4-pole) A/AE9 - A/AE110 1.10 1SXU000023C0202 Contact description Catalog number 2 NO & 2 NC 3 NO & 1 NC 4 NO CA5-22ERT CA5-31ERT CA5-40ERT List price $ 35 Discount schedule AA [OA] - A9 - A110 Discount schedule ABA [OF] - Auxiliary contact blocks Low Voltage Products & Systems A9 - AF1650 Non-reversing, mechanically interlocked, reversing NEMA rated, AC operated, 3 phase A26N1-30-10-84 NEMA Continuous size current A145N4-30-11-84 Maximum motor horsepower ratings Standard Aux. contacts ro co ss nt the ac to line 1 rs AF400N6-30-11-70 Non-reversing Catalog number 200V 230V 460/575V NO NC Ac Mechanically interlocked List price Catalog number Reversing List price Catalog number List price NEMA rated 00 0 1 2 3 4 5 6 7 8 9 18 27 45 90 135 270 540 810 1215 1.5 3 7.5 10 25 40 75 150 -- -- 1.5 3 7.5 15 30 50 100 200 300 450 2 5 10 25 50 100 200 400 600 900 1 1 1 1 1 1 1 1 1 1 0 0 0 1 1 1 1 1 1 1 A9N00-30-10-84 $ 78 A16N0-30-10-84 102 A26N1-30-10-84 183 A50N2-30-11-84 330 A75N3-30-11-84 413 A145N4-30-11-84 825 A260N5-30-11-84 1,815 4,425 AF460N6-3011-70 AF750N7-3011-70 7,200 AF1650N83011-70 10,230 $ 255 345 405 713 1,155 2,235 4,485 13,275 19,725 -- A9N00M-10-84 A16N0M-10-84 A26N1M-10-84 A50N2M-11-84 A75N3M-11-84 A145N4M-11-84 A260N5M-11-84 AF460N6M-11-70 AF750N7M-11-70 -- A9N00R-10-84 A16N0R-10-84 A26N1R-10-84 A50N2R-11-84 A75N3R-11-84 A145N4R-11-84 A260N5R-11-84 AF460N6R-11-70 AF750N7R-11-70 -- $ 315 413 480 810 1,298 2,250 4,500 13,290 19,740 -- Coil voltage selection - A contactors Reversing All AC operated catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Reversing contactors are designed for reversing type starter applications. The complete assembly consists of two mechanically and electrically interlocked contactors mounted as follows with line and load terminals: Ex.: A 240V coil is required for an A75 contactor: A75N3-30-11-80 * A9 - A16 -- mounted on 35mm DIN rail * A26 - A750 -- mounted on common baseplate Coil voltage selection - wide range AC/DC coils The NEMA size 6,7 and 8 contactors are provided with a wide range coil voltage. They are shown with the standard 100-250V AC/DC coil. To select other ranges substitute the code from the coil voltage selection chart for the two digits after the last dash in the catalog number. Ex.: A 24V coil is required for the AF460N6 contactor: AF460N6-3011-68 Auxiliary contact blocks For additional auxiliary contact blocks, see catalog number explanation on page 1.2. Add $ 20 to list price for each additional auxiliary, and see page 1.32 for available combinations. Mechanical interlock Mechanically interlocked contactors are designed for reversing, 2 speed, reduced voltage, etc. type starter applications. The complete assembly consists of two mechanically and electrically interlocked contactors mounted as follows with line and load terminals: For A9 - A750 contactors the NC electrical interlock is provided with the mechanical interlock. Coil voltage selection - A contactors Hz Cntr type 12 24 48 110 120 125 208 60 A 81 83 84 84 34 50 A 81 83 84 Volts 220 240 277 380 415 440 480 500 600 36 80 42 86 86 51 53 55 80 85 86 55 For other voltages, see page 1.24. Coil voltage selection - AF460N6 to AF1650N8 AC/DC VOLTS, 40 - 60 HZ 24 - 60 DC 48 - 130 AC/DC 100 - 250 AC/DC 68 1 69 70 3 250-500 AC/DC 71 2 * A9 - A16 -- mounted on 35mm DIN rail * A26 - A750 -- mounted on common baseplate Power wiring is not included. For A9 - A110 contactors the NC electrical interlock is provided with the mechanical interlock. 1 AF400 - AF750, DC only. 2 AF400 - AF750 only. 3 Only option for AF1650. Low Voltage Products & Systems Discount schedule AA [OA] - A9 - A110 Discount schedule AEA [OC] - A145 - AF750 1SXU000023C0202 1 AE9 - AF1650, AL9 - AL26 Non-reversing, mechanically interlocked, reversing NEMA rated, DC operated, 3 phase e lin e th rs ss cto o r ta Ac con AE26N1-30-11-81 AE & AF Contactors NEMA Continuous size current Maximum motor horsepower ratings Standard Aux. contacts Non-reversing 9 18 27 45 90 135 270 540 810 1215 1.5 3 7.5 10 25 40 75 150 -- -- 1.5 3 7.5 15 30 50 100 200 300 450 AF460N6R-11-68 2 5 10 25 50 100 200 400 600 900 1 1 1 1 1 1 1 1 1 1 0 0 0 1 1 1 1 1 1 1 Mechanically interlocked Catalog number 200V 230V 460/575V NO NC 00 0 1 2 3 4 5 6 7 8 AF145N4-30-11-68 List price Catalog number Reversing List price Catalog number List price NEMA rated AE9N00-30-11-81 $ 118 AE16N0-30-11-81 142 AE26N1-30-11-81 223 AE50N2-30-11-81 375 AE75N3-30-11-81 518 AF145N4-3011-70 1,110 AF260N5-3011-70 2,235 AF460N6-3011-70 4,425 AF750N7-3011-70 7,200 AF1650N83011-70 10,230 AE9N00M-11-81 AE16N0M-11-81 AE26N1M-11-81 AE50N2M-11-81 AE75N3M-11-81 AF145N4M-11-70 AF260N5M-11-70 AF460N6M-11-70 AF750N7M-11-70 -- $ 325 425 485 803 1,365 2,655 5,055 13,275 19,725 -- AE9N00R-11-81 AE16N0R-11-81 AE26N1R-11-81 AE50N2R-11-81 AE75N3R-11-81 AF145N4R-11-70 AF260N5R-11-70 AF460N6R-11-70 AF750N7R-11-70 -- $ 395 493 560 930 1,493 2,670 5,070 13,290 19,740 -- AL Contactors NEMA Continuous size current Maximum motor horsepower ratings Non-reversing 9 18 27 1.5 3 7.5 1.5 3 7.5 2 5 10 1 1 1 0 0 0 Mechanically interlocked Catalog number 208V 240V 460/575V NO NC 00 0 1 Standard Aux. contacts List price Catalog number Reversing List price Catalog number List price NEMA rated AL9N00-30-10-81 AL16N0-30-10-81 AL26N1-30-10-81 $ 155 205 253 $ 319 441 473 AL9N00M-10-81 AL16N0M-10-81 AL26N1M-10-81 AL9N00R-10-81 AL16N0R-10-81 AL26N1R-10-81 $ 379 501 533 Coil voltage selection - AE contactors Reversing All DC operated catalog numbers include a 24VDC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Reversing contactors are designed for reversing type starter applications. The complete assembly consists of two mechanically and electrically interlocked contactors mounted as follows with line and load terminals: Ex.: A 125V coil is required for an AE75 contactor: AE75N3-30-11-87 * AE9 - AE16 -- mounted on 35mm DIN rail * AE26 - AE75 -- mounted on common baseplate Coil voltage selection - AF wide range AC/DC coils All catalog numbers include a 100-250V AC/DC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Ex.: A 24V coil is required for a AF145 contactor: AF145N4-30-11-72 Auxiliary contact blocks For additional auxiliary contact blocks, see catalog number explanation on page 1.2. Add $ 20 to list price for each additional auxiliary, and see page 1.32 for available combinations. Mechanical interlock Mechanically interlocked contactors are designed for reversing, 2 speed, reduced voltage, etc. type starter applications. The complete assembly consists of two mechanically and electrically interlocked contactors mounted as follows with line and load terminals: For AE9 - AE75 contactors the NC electrical interlock is provided with the mechanical interlock. Coil voltage selection - AF50 to AF1650 24 - 60 DC 68 1 20 - 60 DC 72 2 AC/DC VOLTS, 40 - 60 Hz 48 - 130 AC/DC 100 - 250 AC/DC 250 - 500 AC/DC 69 70 4 71 3 Coil voltage selection - AE & AL contactors Hz DC Contactor type AE, AL Volts 12 - 24 81 48 83 110 86 125 87 220 88 240 89 * AE9 - AE16 -- mounted on 35mm DIN rail * AE26 - AE75 -- mounted on common baseplate Power wiring is not included. For AE9 - AE75 contactors the NC electrical interlock is provided with the mechanical interlock. 1 AF400 - AF750, DC only. 2 AF50 - AF300, DC only. 1.12 1SXU000023C0202 3 AF400 - AF750 only. 4 Only option for AF1650. Discount schedule AA [OA] - A9 - A110 Discount schedule AEA [OC] - A145 - AF750 Low Voltage Products & Systems Ac A9 - A/AE75 , EK110 - EK1000, AL9 - AL26 AC & DC operated, UL rated, 4 pole A9-40-00 A75-40-00 ro co ss nt the ac to line 1 rs EK175C4P-PL 4 Pole - 4 NO power poles UL general purpose current AC operated AC operated DC operated 21 30 40 65 80 105 21 30 40 65 80 105 DC operated Catalog number List price List price $ 120 165 228 360 413 525 AL9-40-00-81 AL16-40-00-81 AL26-40-00-81 AE45-40-00-86 AE50-40-00-86 AE75-40-00-86 $ 141 192 246 420 473 570 EK110C4P-1L 743 EK150C4P-1L 1,013 EK175C4P-1L 1,763 EK210C4P-1L 2,025 EK370C4P-1L 4,650 EK550C4P-1L 6,510 EK1000C4P-1L 9,000 EK110C4P-PL EK150C4P-PL EK175C4P-PL EK210C4P-PL EK370C4P-PL EK550C4P-PL EK1000C4P-PL 953 1,238 1,988 2,280 5,010 7,005 9,700 A9-40-00-84 A16-40-00-84 A26-40-00-84 A45-40-00-84 A50-40-00-84 A75-40-00-84 150 150 200 200 250 250 300300 400 400 600 600 1000 1 1000 1 Catalog number 4 Pole - 4 NC power poles UL general purpose current AC operated AC operated Catalog number 30 List price $ 165 A16-04-00-84 4 Pole - 2 NO & 2 NC power poles UL general purpose current AC operated AC operated DC operated 21 30 40 65 105 21 21 30 65 105 DC operated Catalog number List price Catalog number $ 120 165 228 360 525 A9-22-00-84 A16-22-00-84 A26-22-00-84 A45-22-00-84 A75-22-00-84 All AC operated catalog numbers include a 120VAC coil. All DC operated catalog numbers include a 110VDC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Hz Cntr type 12 Volts 24 48 110 120 125 208 220 240 277 380 415 440 480 500 600 60 A 81 83 84 50 A 81 83 84 84 34 36 80 42 80 Ex.: A 240V coil is required for an A75 contactor: A75-30-00-80 For other voltages, see page 1.24. Auxiliary contact blocks Coil voltage selection - EK contactors For additional auxiliary contact blocks, see catalog number explanation on page 1.2. Add $ 20 to list price for each additional auxiliary, and see page 1.32 for available combinations. Please consult factory. $ 141 215 278 420 570 AL9-22-00-81 AL16-22-00-81 AL26-22-00-81 AE45-22-00-86 AE75-22-00-86 Coil voltage selection - A contactors Coil voltage selection Accessories for EK List price Hz Contr. type 86 85 51 53 86 86 55 55 Volts 24 48 110 120 125 208 220 240 277 380 415 440 480 500 600 G 60 EK F 50 EK N 1 J DC EK Y P R W 1 B Q 2 C Z 3 3 4 M 6 5 T * For other voltages, consult factory. * 24 & 48VAC coils are not available for sizes EK550. For these applications, use an interposing control relay. Coil voltage selection - AE & AL contactors Hz Contr. DC type AE, AL Volts 12 - 24 81 48 83 110 86 125 87 220 88 240 89 For other voltages, see page 1.24. 1 Not UL Listed. IEC value AC1 for 40C. Low Voltage Products & Systems Discount schedule AA [OA] - A9 - A75 Discount schedule AEA [OC] - EK110 - EK550 1SXU000023C0202 1 e lin e th rs ss cto o r ta Ac con AF45 - AF75 AC & DC operated, UL rated, 4 pole Auxiliary contact blocks For additional auxiliary contact blocks, see catalog number explanation on page 1.8. Add $ 20 to the list price for each additional auxiliary and see page 1.32 for available combinations. If auxiliary contacts are required for AF50 - AF750 contactors, add $ 40 to the list price and change the 8th & 9th digits in the catalog number from "00" to "11". 4 Pole -- 4 NO power poles General purpose Auxiliary contacts Catalog number AC1 NO NC 65 80 105 0 0 0 0 0 0 AF45-40-00-70 AF50-40-00-70 AF75-40-00-70 List price $ 385 435 645 4 Pole -- 2 NO - 2 NC power poles General purpose Auxiliary contacts AC1 NO 65 105 0 0 Catalog number List price NC 0 0 AF45-22-00-70 AF75-22-00-70 $ 385 645 These contactors (2 NO & 2 NC power poles) can be used for controlling either 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit comprising 2 separate loads with 1 single supply (see diagrams below). When the contactor operates, there is no mechanical overlapping between the NO main poles and NC main poles: Break before Make. These contactors (2 NO & 2 NC power poles) are not suitable for a reversing starter or a wye-delta starter or for controlling a single load from 2 separate supplies. 1 single supply and 2 separate loads 2 separate supplies and 2 separate loads Supply "Main" supply "Back-up" supply A1 1 R3 A2 2 R4 R5 7 A1 R6 8 A2 1 R3 2 R4 R5 7 R6 8 Load Load Load Load Coil voltage selection - wide range AC/DC coils All catalog numbers include a 100-250V AC/DC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Ex.: A 24V coil is required for a AF45 contactor: AF45-22-00-72 Coil voltage selection - AF50 to AF75 AC/DC VOLTS, 40 - 60 HZ 24 - 60 DC 20 - 60 DC 48 - 130 AC/DC 68 1 72 2 69 100 - 250 AC/DC 70 1 AF400 - AF750, DC only. 2 AF50 - AF300, DC only. 1.14 1SXU000023C0202 Discount schedule AA [OA] - AF45 - AF75 Low Voltage Products & Systems Ac UA26 - UA110 for 3 phase capacitor switching, 3 phase AC operated UA75-30-00-84 ro co ss nt the ac to line 1 rs UA95-30-00-84 Max kvar switching capacity Standard auxiliary contacts Catalog number List price 240V 480V 575/600V NO NC 12.5 25 30 1 0 UA26-30-10-84 $ 225 16 32 40 1 0 UA30-30-10-84 338 20 40 50 0 1 0 1 UA50-30-00-84 UA50-30-11-84 345 375 27.5 55 70 0 1 0 1 UA75-30-00-84 UA75-30-11-84 450 480 35 70 75 0 1 0 1 UA95-30-00-84 UA95-30-11-84 465 495 40 80 85 0 1 0 1 UA110-30-00-84 UA110-30-11-84 525 570 For 3 phase capacitors carrying out single bank or stepped bank compensation. Max. peak current I: 100 times the capacitor nominal r.m.s. current at Ue 500V or 90 times for Ue>500V Electrical durability: 100,000 operating cycles. Power in kvar Contactor 208V 240V 480V 600V Max amps UA26 UA30 UA50 UA75 UA95 UA110 3.5 7.0 10.5 21.5 25.0 28.5 4.0 8.0 12.5 25.0 29.0 33.0 8.0 16.5 25.0 50.0 58.0 66.0 10.0 20.5 31.0 62.0 72.0 83.0 10 20 30 60 70 80 A145 A185 A210 A260 A300 43 57 66 75 88 50 66 77 87 101 100 133 153 174 203 125 166 192 218 254 120 160 185 210 245 AF400 AF460 AF580 AF750 119 142 178 214 137 164 205 247 274 329 411 495 343 410 514 618 330 396 495 595 Coil voltage selection Coil voltage selection chart All AC operated catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the Coil Voltage Selection Chart for the two digits after the last dash in the catalog number. Cntr Hz type 12 24 48 110 120 125 208 60 A 81 83 84 84 34 50 A 81 83 84 Auxiliary contact blocks Volts 220 240 277 380 415 440 480 500 600 36 80 42 86 86 51 53 55 80 85 86 55 For other voltages, see page 1.24. For additional auxiliary contact blocks, see catalog number explanation on page 1.2. Add $20 to list price for each additional auxiliary, and see page 1.32 for available combinations. Low Voltage Products & Systems Discount schedule AA [OA] - UA26 - UA110 1SXU000023C0202 e lin e h s s t ctor s o 1 cr nta A co Accessories for A/AF/AL & AE contactors Auxiliary contact blocks - Standard Maximum number of contact blocks Positioning 4 blocks: A9 - A26 AE9 - AE26 Front mounting AL9 - AL26 (single pole) 5 blocks: A30, A40, AE30, AE40, AL30, AL40 6 blocks: A45 - A110 AE45 - AE110 AF45 - AF110 CAL5-11 CA5-10 A9 - A26-40-00 A30 - A110 Front mounting 1 block: AE9 - AE110 (4 pole) 1 block: A9 - A40-30-10 AL9 - AL40-30-10 2 blocks: A9 - A75, AE9-AE45 1 block: AE50 - AE75, AL9 - AL40 Side mounting 1 block: A/AE/AF95 - A/AE/AF110 (2 pole) 2 blocks: A145 - A300, AF145-AF2050 2 blocks: A145 - A300, AF145-AF2050 Contact Description Catalog number 1 N.O. 1 N.C. CA5-10 CA5-01 1 N.O. Early make 1 N.C. Late break CC5-10 CC5-01 4 N.O. 3 N.O. & 1 N.C. 2 N.O. & 2 N.C. 4 N.C. 2 N.O./2 N.C.1 CA5-40E CA5-31E CA5-22E CA5-04E CA5-11/11E 3 N.O. & 1 N.C. 2 N.O. & 2 N.C. 1 N.O. & 3 N.C. 4 N.C. 4 N.O. 2 N.O./2 N.C.1 CA5-31M CA5-22M CA5-13M CA5-04M CA5-40N CA5-11/11M 1 N.O. & 1 N.C. CAL5-11 1 N.O. & 1 N.C. CAL18-11 List price $ 15 30 1 N.O. & 1 N.C. (inside L or R) CAL18-11 1 N.O. & 1 N.C. (outside, L or R) CAL18-11B Auxiliary contact blocks - Front mounting, switching low voltage and low current Positioning Front mounting (single pole) Maximum number of contact blocks Degree of protection Catalog number List price 4 blocks: A9 - A26 AE9 - AE26 AL9 - AL26 1 N.O. 1 N.C. 1 N.O. 1 N.C. IP40 IP40 IP40 IP40 CE5-10D0.1 CE5-01D0.1 CE5-10D2 CE5-01D2 $ 38 5 blocks: A30, A40, AE30, AE40, AL30, AL40 6 blocks: A45 - A110 AE45 - AE110 AF45 - AF110 1 N.O. 1 N.C. 1 N.O. 1 N.C. IP67 IP67 IP67 IP67 CE5-10W0.1 CE5-01W0.1 CE5-10W2 CE5-01W2 42 1 Includes 1 N.O. & 1 N.C. overlapping 1.16 Contact Description Discount schedule ABA [OF] Ac ro co ss nt the ac to line rs Accessories Auxiliary contact block technical data CA5/CAL5-11/CAL18-11/CC5 Types 1-pole CA5, 4-pole CA5 2-pole CAL5-11 and 1-pole CC5 Standards CAL18-11 CAL18-11B IEC 947-5-1 and EN 60947-5-1 Rated insulation voltage Ui according to IEC 947-5-1 according to UL/CSA V V Rated operational voltage Ue 690 600 690 690 ~V Conventional thermal current Ith 24 to 690 A 16 Rated operational current Ie in AC-15 acc. to IEC 947-5-1 24 to 127 V A 6 220 to 240 V A 4 380 to 440 V A 3 500 to 690 V A 2 in DC-13 acc. to IEC 947-5-1 A A A A A 24 V 48 V 72 V 125 V 250 V 6 2.8 1 0.55 0.3 Connecting terminals M 3.5 (+,-) pozidriv 2 screw with cable clamp (delivered in open position. Screws of unused terminals should be tightened). Connecting capacity * Rigid solid 1 or 2 x mm2 1 to 4 1 x mm2 2 x mm2 * Flexible with cable end Mechanical durability 0.75 to 2.5 0.75 to 2.5 cycles Max. switching frequency Electrical durability Max. switching frequency 10 million, A9 - A75; cycles/h 3600 cycles/h See curve below 1200 Rated making capacity Rated breaking capacity Rated short-time withstand current Icw q = 40C 5 million, A/AF95 - A/AF185; 3 million, A/AF210 - AF750; 0.5 million, AF1350 & AF1650 10 x Ie AC-15 10 x Ie AC-15 A A 1s 0.1 s 100 140 Min. switching capacity 17 V / 1 mA 24V / 50 mA Short-circuit protection - gG (gl) fuses A 10 Power loss per pole at 6 A W 0.15 Degree of protection according to IEC 529, IEC 144, DIN 40 050 and NFC 20-010 IP 20 CA5, CAL5 Million ops. CAL18 30 30 20 20 10 10 5 Million ops A/AF95...A/AF185 5 A/AF210...AF750 3 2 1 AF1350/AF1650 0.5 2 1 0.5 0.3 0.2 0.1 0.02 CA 5, CAL 5 3 0.3 0.2 0.05 0.1 0.2 0.3 0.5 1 2 3 4 5 6 10 Breaking current (A) Electrical durability 0.1 0.02 0.05 0.1 0.2 0.3 0.5 1 2 3 4 5 6 10 Breaking current (A) AC-15 according to IEC 947-5-1 making current: 10 x Ie where cos = 0.7 and Ue breaking current: Ie where cos = 0.4 and Ue The curves opposite show the electrical durability of the auxiliary contact blocks according to breaking current Ic. These curves have been plotted for resistive and inductive loads up to 690 V, 40 to 60 Hz. Low Voltage Products & Systems ABB 1.17 1 e lin e h s s t ctor s o 1 cr nta A co Accessories Auxiliary contact block technical data CE5 Auxiliary contact blocks for switching low level voltage and current Types CE5-10D0.1 CE5-01D0.1 CE5-10W0.1 CE5-01W0.1 Version 100 mA Standards CE5-10DZ CE5-01DZ CE5-10WZ CE5-01WZ Version 2 A IEC 947-5-1 and EN 60947-5-1 Approvals UL / CSA Rated insulation voltage Ui according to IEC 947-5-1 according to UL/CSA V V 250 125 250 250 Rated operational voltage Ue V 125 250 Rated operational current Ie in AC-15 or AC-14 acc. to IEC 947-5-1 A 0.1 in DC-12 acc. to IEC 947-5-1 24 V A 0.1 60 V A 0.1 110 V A 0.1 220 V A 0.1 2 2 0.5 0.2 0.1 Minimal switching 3 V / 1 mA 17 V / 1 mA Reliability for the minimal switching 10 -8 Connecting terminals M3.5 (+,-) posidriv 2 screw with cable clamp Connecting capacity * Rigid solid * Flexible with cable end 1 ou 2 (1...4) mm2 1 ou 2 (0.75... 2.5) mm2 Short circuit protection Degree of protection according to IEC529, IEC 144, DIN 40 050, NFC 20-010 1SXU000023C0202 10 A IP 20 Mounting Dimensions 1.18 100 mA Front mounting on contactors: A, AE, TAE9...110, AL, AF, GA, N, NE Identical to those of CA5 single pole Low Voltage Products & Systems ABB Inc. Ac ro co ss nt the ac to line rs Accessories for A/AF/AL & AE contactors Pneumatic timers Mounting on Timing range A9 - A75 AE9 - AE75 AL9 - AL40 On delay 0.1 - 40 s On delay 10 - 180 s Off delay 0.1 - 40 s Off delay 10 - 180 s Contacts N.O. N.C. 1 1 1 1 1 1 1 1 Catalog number TP40DA TP180DA TP40IA TP180IA List price $ 108 Interlocks for two horizontally mounted contactors - A9 - A110 TP40DA Feature Mounting on Mechanical/electrical Mechanical/electrical Mechanical A/AE/AL9 - A/AE/AL40 A45 - A110 A/AE/AL9 - A/AE/AL40 Contacts N.O. N.C. - - - 2 2 - Catalog number VE5-1 VE5-2 1 VM5-1 List price $ 45 45 21 Interlocks for two horizontally mounted contactors - A95 - AF1250 contactors Left contactors Feature Mechanical Mechanical Mechanical VE5-1 A95 - A300 A210 - A300 AF400 - AF1250 Right contactors A145 - A300 AF400 - AF460 AF400 - AF1250 Catalog number VM300H VM300/460H VM750H List price $ 110 130 150 Interlocks for two vertically mounted contactors - A95 - AF1250 contactors Top contactor Feature Mechanical Mechanical Mechanical VM300H A95 - A300 A210 - A300 AF400 - AF1250 Left contactor Mechanical LK75-F A145 - A300 AF400 - AF460 AF400 - AF1250 Catalog number VM300V VM300/460V VM750V List price $ 205 250 270 Interlocks for two horizontally mounted contactors - AF1350 - AF2050 contactors Feature LK75-L Bottom Contactor LK110 AF1350 - AF2050 Right Contactor AF1350 - AF2050 Catalog number VM1650H List price $ 655 Auxiliary lead terminals Mounting on Connections Connects from side Connects from top Connects from side A50 - A75 A50 - A75 A95 - A110 Catalog number LK75-L LK75-F LK110 List price $ 15 15 23 1 Use type VE 5-2 for mechanical and electrical interlocking between A30/A40 and A50 - A75 contactors. Low Voltage Products & Systems ABB Inc. Discount schedule ABA [OF] 1.19 1 e lin e h s s t ctor s o 1 cr nta A co Accessories for A/AE/AL/AF contactors Terminal lug kits (Set of 3) Wire range For contactor 6 - 300 MCM 4 - 400 MCM (2) 4-500 MCM (2) 2/0 - 500 MCM (3) 2/0 - 500 MCM (4) 4/0 - 500 MCM (4) 1/0 - 750 MCM (6) 1/0 - 750 MCM ATK185 Catalog number A145 A210 A210 AF400 AF580 - A185 - A300 - A300 - AF580 - AF1250 AF1350 AF1350 - AF2050 AF1350 - AF2050 List price $ 45 68 110 150 225 235 335 560 ATK185 ATK300 ATK300/2 ATK580/2 ATK750/3 ATK1350/4 ATK1650/4 ATK1650/6 Contact kits Catalog number For contactors List price 3 Pole ATK750/3 ZL75 A/AE/AF50 A/AE/AF63 A/AE/AF75 A/AE/AF95 A/AE/AF110 ZL50 ZL63 ZL75 ZL95 ZL110 $ 113 135 158 225 255 A/AF145 A/AF185 A/AF210 A/AF260 A/AF300 ZL145 ZL185 ZL210 ZL260 ZL300 300 420 525 855 1,020 AF400 AF460 AF580 AF750 AF1250 AF1350 AF1650 AF2050 ZL400 ZL460 ZL580 ZL750 ZL1250 ZL1350 ZL1650 ZL2050 1,716 2,434 3,795 3,960 5,280 4,255 4,890 6,290 A/AE45 A/AE50 A/AE75 ZLT45 ZLT50 ZLT75 150 150 210 UA50 UA75 UA95 UA110 ZLU50 ZLU75 ZLU95 ZLU110 150 215 306 347 4 Pole 3 Pole Mechanical latches Catalog number For contactors ZL145 A9 - A75, AE45 - AE75, & AL9 - AL40 List price $ 84 WB75A- - Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the . Coil voltage selection chart - mechanical latches for A, AE & AL contactors Voltage code 50 Hz (AC/DC) 60 Hz (AC) 24 42 48 110 WB75A-04 24 42 48 110 - - - - 28 48 55 127 Voltage code 50 Hz (DC) 60 Hz (AC) 01 02 03 04 220 230 380 415 - - - - 230 240 415 440 220 230 380 440 - - - - 06 05 07 08 255 277 440 480 Range: WB75A for contactors A9 - A75, AL9 - AL40, AE45 - AE75 and control relays N and NL. Description: WB75A block: contains a mechanical latching device with electromagnetic impulse unlatching (AC or DC) or manual unlatching. Captive screw type connecting terminals, built-in cable clamps, M 3.5 (=, -) posidrive 1 screw with screwdriver guidance, delivered untightened and protected against accidental direct contact. Operation: After closing, the contactor continues to be held in the closed position by the latching mechanism should the supply voltage fail at the contact coil terminals. Contactor opening can be controlled: * * Electrically by an impulse* (AC or DC) on the WB75A block coil. The coil is not designed to permanently energized. Manually by pressing the pushbutton on the front face of the WB75A block. Mounting: WB75A is clipped onto the front face of the contactor. Identification markers Mounting on BA5-50 1.20 1SXU000023C0202 Coil voltage A/AE/AL/AF9 - A/AE/AL/AF110 Discount schedule ABA [OF] Pack of 50 Catalog number List price BA5-50 $ 15 Low Voltage Products & Systems ABB Inc. Ac ro co ss nt the ac to line rs Accessories for A/AE/AL/AF contactors Connection kits for reversing Catalog number Mounting on 3 pole contactors BER... List price A/AE/AL9 - A/AE/AL16 A/AE/AL26 - A/AE/AL40 BER16V BER40V $ 35 49 A/AE/AF50 - A/AE/AF75 A/AE/AF95, A/AE/AF110 A/AF145 - A/AF185 A/AF210 - A/AF300 BEM75-30 BEM110-30 BEM185-30 BEMA300-30 165 180 260 470 AF400 - AF460 AF580 - AF750 BEM460-30 BEM750-30 850 1,200 Application Connections between the main poles of two 3 pole contactors mounted side by side so that they operate as reversing contactors. BEM... A1 A2 1 3 5 1 3 5 2 4 6 2 4 6 A1 A2 Description The connection kits for reversing contactors are made up of three reversing connections and three phase to phase connections. BER16V - Molded plastic, solid copper bars BER40V - Molded plastic, solid copper bars BEM75 and 110-30 - Insulated, solid copper bars Connection kits for phase to phase BEM circuit diagram Catalog number Mounting on 3 pole contactors A/AE/AF50, A/AE/AF75 A/AE/AF95, A/AE/AF110 A/AF145 - A/AF185 A/AF210 - A/AF300 AF400 - AF460 AF580 - AF750 A2 BES75-30 BES110-30 BES185-30 BESA300-30 $ 75 90 130 200 BES460-30 BES750-30 425 650 Catalog number List price The connection kit for phase to phase contactors is made up of three phase to phase bus bars. BES... A1 List price 1 3 5 1 3 5 2 4 6 2 4 6 A1 Connection kits for wye-delta starters Mounting on contactors A2 BES110 connection diagram BED... Line and delta contactor Wye contactor A9 A12 A16 A26 A30 A40 A50 A63 A75 A95 A110 A145 A185 A210 A260/A300 AF400/AF460 AF460 AF580 AF750 A9 A9 A12 A16 A26 A26 A30 A40 A50 A75 A95 A110 A145 A185 A210 A260/A300 AF400 AF400/AF460 AF580 Application Connections between the main poles of a wye-delta starter. BEY... BEY16V-2 $ 46 BEY26-2 76 BEY40-2 76 BED50U BED75U BED95U BED110U BED145U BED185U BED210U BED300U BED400U BED460U BED580U BED750U 165 180 195 225 250 290 375 500 850 900 1,250 1,450 Description The connection kits for wye-delta starters are made up of: * Three line contactor/wye contactor connections - line side. * Three wye contactor/delta contactor connections - load side. * The shorting connection for the "S" contactor. BEY16V-2, BEY26-2, BEY40-2 - Molded plastic, solid copper bars BED50U thru BED750U - Insulated, solid copper bars. The above connection sets allow a mechanical interlock unit to be mounted between the wye and delta contactors if required. Low Voltage Products & Systems ABB Inc. Discount schedule ABA [OF] 1.21 1 e lin e h s s t ctor s o 1 cr nta A co Accessories for A/AE/AL/AF contactors Additional terminal blocks Wire range Mounting on 3 pole contactors A/AE/AL9 - A/AE/AL16 (set of 2) A/AE/AL26 (set of 2) A/AE/AL30 - A/AE/AL40 A/AE/AF50 - A/AE/AF75 A/AE/AF95 - A/AE/AF110 Catalog number 16 - 6 14 - 6 12 - 4 10 - 2 8-1 LD-16 LD-26 LD-40 LD-75 LD-110 List price $ 20 22 26 28 30 Utilization - The LD series terminal block is designed to increase the connection capacity of the contactor on which it is mounted. The LD 75 and LD110 terminal blocks are mounted in the three independent apertures located above the built-in connectors. Terminal extensions Mounting on contactors Catalog number A/AE/AF50 - A/AE/AF75 A/AE/AF95, A/AE/AF110 A/AF145 - A/AF185 A/AF210 - A/AF300 AF400 - AF460 AF580 - AF750 LD110 List price BEXT-75 LW110 LX185 LX300 $ 15 95 90 140 LX460 LX750 195 225 Application They are designed to increase the width of the contactor terminal pads to allow larger connectors to be mounted. Description Terminal extension sets contain 3 bars. Terminal shrouds - two pieces LX... Catalog number For contactor BEXT-75 A/AF145 A/AF145 A/AF145 A/AF210 A/AF210 A/AF210 - - - - - - A/AF185 for flush mount A/AF185 for extended mount A/AF185 for shorting bar LY... between A(F)145 / A(F)185 & TA200DU A/AF300 for flush mount A/AF300 for extended mount A/AF300 for shorting bar LY300 LT185-AC LT185-AL LT185-AY LT300-AC LT300-AL LT300-AY AF400 AF400 AF580 AF580 - - - - AF460 for flush mount AF460 for extended mount AF1250 for flush mount AF1250 for extended mount LT460-AC LT460-AL LT750-AC LT750-AL $ 10 20 Terminal enlargements Catalog number For contactor A/AF95 - A/AF110 A/AF145 - A/AF185 A/AF210 - A/AF300 AF400 - AF460 AF580 - AF750 AF1250 LT185-AC List price LW110 LW185 LW300 LW460 LW750 LW1250 List price $ 95 120 130 295 355 375 Arc chutes Catalog number For contactor A/AF145 A/AF210 A/AF400 A/AF580 AF1350 - - - - - A/AF185 A/AF300 A/AF460 A/AF750 AF1650 ZW185 ZW300 ZW460 ZW750 ZW1650 List price $ 130 180 190 230 215 LT185-AL LW... 1.22 1SXU000023C0202 Discount schedule ABA [OF] Low Voltage Products & Systems ABB Inc. Ac ro co ss nt the ac to line rs Accessories for A/AE/AF contactors Vertical connection bars between contactor and MCCB - three bars MCCB BEA185/S3/S4 Catalog number For contactor T1 T3 T3 S3, S4 T4 T4 T5 T5 S5 S51 S6 A/AE/AF50 A/AE/AF95 A/AF145 A/AF145 A/AF145 A/AF210 A/AF210 A/AF400 A/AF210 AF400 AF400 - - - - - - - - A/AE/AF75 A/AE/AF110 A/AF185 A/AF185 A/AF185 A/AF300 A/AF300 A/AF750 A/AF300 AF460 AF750 BEA75/T1 BEA110/T3 BEA185/T3 BEA185/S3/S4 BEA185/T4 BEA210/T4 BEA300/T5 BEA750/T5 BEA300/S5 BEA400/S5 BEA750/S6 List price $ 85 95 60 60 70 70 75 115 75 95 115 Vertical connection bars between contactor and MCCB - three bars MCCB BEAD185D/S3/S4 Catalog number List price BEA185D/S3/S4 BEA210D/S4 BEA300D/S5 BEA400D/S5 BEA750D/S6 $ 70 80 85 105 125 For contactor S3, S4 S4 S5 S5 S6 A/AF145 A/AF210 A/AF210 AF400 AF400 - - - - - A/AF185 A/AF300 A/AF300 AF460 AF750 To be used when power take off is needed (IP00) or with other bus bars. (EX: Reversing, IP20) Horizontal connection busbars between contactor and MCCB - three bars MCCB BEA185H/S4 For contactor Catalog number List price S3, S4 S4 S5 A/AF145 - A/AF185 A/AF210 - A/AF300 A/AF210 - A/AF300 BEA185H/S4 BEA210H/S4 BEA300H/S5 $ 150 220 220 S5 S6 S6 AF400 - AF460 AF400 - AF460 AF580 - AF750 BEA400H/S5 BEA460H/S6 BEA750H/S6 435 660 670 Shorting bars, 2 pole For contactor LP185 Catalog number List price A/AF145 - A/AF185 A/AF210 - A/AF300 LP185 LP300 $ 35 50 AF400 - AF460 AF580 - AF750 LP460 LP750 50 50 Shorting bars, 3 pole For contactor A/AE45 - A/AE/AF75 LY... Catalog number LF75 List price $ 40 A/AE/AF95 - A/AE/AF110 A/AE/AF145 - A/AE/AF185 A/AE/AF210 - A/AE/AF300 LY110 LY185 LYA300 40 40 60 AF400 - AF460 AF580 - AF750 LY460 LY750 60 60 1 Not for use with flange handles. Low Voltage Products & Systems ABB Inc. Discount schedule ABA [OF] 1.23 1 e lin e h s s t ctor s o 1 cr nta A co Accessories for A/AE/AL/AF contactors Coils & coil voltage codes Coils - AC operated Catalog number For contactors ZA16-81 List price $ 24 30 57 60 150 180 A9 A26 A45 A95 A145 A210 - - - - - - A16 A40 A75 A110 A185 A300 ZA16- ZA40- ZA75- ZA110- ZA185- ZA300- AE9 AE26 AE45 AE95 - - - - AE16 AE40 AE75 AE110 ZAE16- ZAE40- ZAE75- ZAE110- 24 30 57 90 CCL18-01 45 ZAF75- ZAF110- ZAF185- ZAF300- ZAF460- ZAF750- ZAF1650- 120 165 200 240 450 525 920 Coils - DC operated Auxiliary including an insertion contact and a varistor for DC operated contactors AE95 - AE110 Coils - AC/DC operated (coil and printed circuit board except ZAF1650) AF45 - AF75 AF95, AF110 AF145 - AF185 AF210 - AF300 AF400, AF460 AF580, AF750, AF1250 AF1350, AF2050 (Set of 2 coils only) ZAF1650 Printed circuit board - AC/DC operated AF1350 - AF2050 1,620 ZP1650 - Coil voltage suffix. Refer to Coil Voltage Selection charts below and substitute the desired coil voltage code for the . ZP1650 Coil voltage selection - DC operated for AE contactors Coil voltage selection - AC operated for A9 - A300; UA26 - UA110 VAC (50Hz) VAC (60Hz) 24 26 28 42 48 60 100 110 110 - 115 120 125 - 127 175 190 200 220 - 230 230 - 240 230 - 240 230/400 - 380 - 400 400 - 415 - 440 500 550 660 - 690 1 2 3 4 5 6 7 24 28 32 42 48 60 100 - 110 110 - 120 115 - 127 140 150 208 220 200 - 220 230 - 240 240 - 260 277 - 230/400 400 - 415 415 - 440 480 500 600 - - Voltage Code 81 16 17 82 83 73 74 2 84 89 3 29 30 34 36 75 2 80 88 42 62 1 63 1 85 86 51 53 55 56 58 VDC Voltage code AE contactors 80 81 82 83 21 84 85 86 87 88 89 38 12 24 42 48 50 60 75 110 125 220 240 250 Coil voltage selection - AC/DC operated for AF50 - AF2050 VAC & VDC 40-60 Hz 24 20 48 100 250 - - - - - Suffix Code 68 72 69 70 71 60 VDC 60 VDC 130 VAC/VDC 250 VAC/VDC 500 VAC/DC 4 5 7 6 Only for A9 - A16. Not for A145 - A300 A145 - A300 at 60 Hz, 115V only AF400 - AF1250, DC only AF45 - AF300 AF400 - AF750 only Only option for AF2050 - AF1650 1.24 1SXU000023C0202 Discount schedule ABA [OF] Low Voltage Products & Systems ABB Inc. Ac ro co ss nt the ac to line rs Accessories for EK contactors Coils & coil voltage codes Coils - AC & DC operated AC Coils Contactor size Catalog number EK110, EK150 EK175, EK210 EK370, EK550 KH210- KH300- KH800- DC Coils List price $ 200 240 580 Catalog number List price $ 200 240 580 KH210- KH300- KH800- - Coil voltage suffix. Refer to the Coil Voltage Selection chart and substitute the desired coil voltage suffix for the . AC and DC operated contactors DO NOT have the same magnet structure. Therefore, DC coils will not fit on an AC magnet structure and vice versa. Coil voltage selection - AC operated for EK110 - EK550 VAC (50Hz) VAC (60Hz) - 24 - 110 - - 220 - 230 - 380 - 400 400 - 415 - 500 - 24 - 48 120 208 240 - 380 440 - 480 - 600 Coil voltage selection - DC operated for EK110 - EK550 Voltage Code F N G 1 B 2 J Z 3 M 4 5 6 VDC Voltage Code 24 48 110 125 220 440 Y W P Q R T Consult factory if other voltages are required. Consult factory if other voltages are required. Low Voltage Products & Systems ABB Inc. Discount schedule AB 1.25 1