MULTI- CONDUCTOR 24 AWG 0.050" CENTER FLAT SDL CABLE Jacket Width TABLE 2 - P/N & JACKET COLOR Primary Width Span Pitch +0.005" 0.120 -0.005" 0.010" Nom Jacket Color 04WFZLF005 Raven Black 04WFZLF006 Gray 06WFZLF003 Black 06WFZLF007 Gray 08WFZLF003 Black 08WFZLF006 Gray 16WFZLF003 Black 16WFZLF006 Gray Shield 0.020" ELECTRICAL CHARACTERISTICS Insulation Drain Wire Jacket Conductor CONSTRUCTION Single Component Conductor: 24 AWG 7/32 Tin Plated Copper, 0.024 Inch Diameter Pitch: 0.050 0.003 Inches Final Assembly Core1: Multi-conductors Laid Flat and Parallel Insulation: 0.012 Inches of PVC, 0.048 Inch Minor Diameter Drain Wires (2): 28 AWG 7/36 Tin Plated Copper, 0.015 Inch Diameter Shield: Aluminum/Polyester/Aluminum Tape, 25% Overlap, Applied Longitudinally Jacket: 0.032 Inches of PVC, Color - See Table 2 Minor Diameter: 0.120 0.005 Inches Major Diameter: See Jacket Width in Table 1 Print Legend (Light Gray Ink): "MADISON CABLE (UL) TYPE CL2 90C 24 AWG CSA AWM II A/B 90C 300V FT1 SUBSTANCE COMPLIANT 2011/65/EU" 1 Madison P/N Impedance (Signal-to-Ground): 39 Ohms Nominal @ 1 MHz Capacitance: 60 pF/ft Maximum @ 1 MHz Time Delay: 2.0 ns/ft Maximum Insulation Resistance: 1000 Megohms-10 ft @ 20C Shield Effectiveness: 30 dB Minimum @ from 30 to 1000 MHz Dielectric Withstand: 1500 Volts RMS Crosstalk: Near-End: 1% Maximum Peak-to-Peak @ 2 ns Rise-Time, 10-90%, on a 10 ft sample Far-End: 4% Maximum Peak-to-Peak @ 2 ns Rise-Time, 10-90%, on a 10 ft sample Conductor DC Resistance: 0.024 Ohms/ft Nominal @ 20C SAFETY CERTIFICATION UL Listing: Type CL2 as specified in Article 725 of the National Electrical Code CSA Certification: AWM II A/B 90C 300 Volts FT1 RoHS II Material Compliance: In accordance with EU Directive 2011/65/EU for the Restriction of Hazardous Substances Drawing shows only a 4-conductor construction as an example. TABLE 1 - P/N & CONSTRUCTION Madison P/N Nomber of Conductor 04WFZLF005 Dimensions Span (Inches) Primary Width (Inches) Jacket Width (Inches) 4 0.150 0.005 0.200 0.005 0.275 +0.005/-0.010 04WFZLF006 4 0.150 0.005 0.200 0.005 0.275 +0.005/-0.010 06WFZLF003 6 0.250 0.006 0.300 0.006 0.375 +0.005/-0.010 06WFZLF007 6 0.250 0.006 0.300 0.006 0.375 +0.005/-0.010 08WFZLF003 8 0.350 0.007 0.400 0.007 0.475 +0.005/-0.010 08WFZLF006 8 0.350 0.007 0.400 0.007 0.475 +0.005/-0.010 16WFZLF003 16 0.750 0.011 0.800 0.011 0.875 +0.005/-0.010 16WFZLF006 16 0.750 0.011 0.800 0.011 0.875 +0.005/-0.010 Spec Number: 101-2676 Part Number: See Table 1 Customer: Customer #: 1 2 3 4 5 06/10/05 11/30/05 06/23/11 02/11/13 06/05/15 EP EP DM HA DC REVISION HISTORY Initial Release Revised Legend Revised print legend Revised Print Legend and Safety Certification Revised Jacket Color on 04WFZLF005 Prepared By: D.M. Card Reviewed By: T. Grzysiewicz Page 1 of 1 Users should evaluate the suitability of this product for their application. Contact factory for latest revision of specification. TE Connectivity reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to the Buyer. Form AP-03A Issue 10