Uninterruptible Power Systems Eaton Software and Connectivity September 2011 33.4-1 Sheet 33 085 Power Xpert Software Power Xpert(R) Software Product Selection Guide Foreseer(R) Services General Description Power Xpert Software Professional Edition Foreseer Software and Engineering Services (Foreseer Services) provide vendor independent, power and energy infrastructure integration solutions that help companies reduce energy consumption and unplanned downtime due to the failure of critical power, environmental, safety or security systems. Power Xpert Software aggregates the information arriving from different types of device families via various communication methods. Its unique Web-based design, alarm bubble-up, and advanced trend and waveform analysis tools help you to quickly turn your attention to the most important events and to identify reliability issues and cost-saving opportunities. The standard custom graphic package, the Layout Manager, with an icon library and standard vertical templates, allows you to import and mimic your physical environment and gauges. Open protocol support makes Power Xpert Software compatible with most newer generation third-party equipment. Older legacy, proprietary protocols are supported by Power Xpert Gateways, and custom software drop-in drivers made available by Eaton. Power Xpert Software is the first power system software of this caliber to put all of these powerful features at your fingertips. Power Xpert Software provides an easy upgrade path to allow existing PowerNet users to enjoy the benefits of power monitoring through a simple Web browser interface. Power Xpert is a complete software solution to manage your power system. Critical components such as metering devices, protective relays, circuit breaker trip units, motor starters and uninterruptible power supplies communicate vital information about the health and status of critical infrastructure devices. Geared toward end users, with builtin support for Eaton power distribution products such as switchgear, UPSs, breakers, PDUs, RPPs, meters, relays, VFDs and MCCs, among others Eaton products connect with the software directly via an Ethernet connection, while legacy devices use a Power Xpert Gateway to Webenable their communications A subset of third-party meters and devices are supported as standard via the gateway connection Power Xpert Software Enterprise Edition Geared toward advanced power users, system integrators and enterprises with heterogeneous device spectrum and system developers who can take advantage of the included SNMP and Modbus integration development utilities Extensive support for third-party devices via standard SNMP and Modbus TCP protocols Large variety of ready made, optional third-party drop-in drivers available Turnkey software and connectivity solutions are coupled with state-ofthe-art project management, systems design, third-party device integration, testing and custom application development to develop a comprehensive monitoring solution to meet your custom needs. Features Connects to your existing network Data trending and graphing for detailed information for troubleshooting, problem prevention and costs savings Web-based views that allow access to critical information from any location via a Web browser A modular, scalable architecture that allows the addition of capabilities and devices as the power system expands Alarm conditions bubble up through the system to allow personnel to identify which device is in alarm and where it is located All the functionality of Eaton's PowerNet software suite Connectivity to a wide range of Eaton and third-party devices. For a full list of compatible devices, refer to the hardware compatibility list found at www.eaton.com/pxs For full details on Power Xpert Software, refer to Tab 2, Section 2.4. Foreseer Services is delivered in categories, offering a multitude of unique value-add services that you can discuss with your Eaton sales professional. Design services Installation services Commissioning services Follow-up services Hardware services Software services Foreseer Services is fully distributable to allow different monitoring capabilities to be deployed at different sites, allowing you to purchase only what is needed. Many competitive systems offer a one-size-fits-all type approach where you end up paying for more capacity than is needed. With Foreseer Services, you pay only for what you need, when you need it. For full details on Foreseer Services, refer to Tab 2, Section 2.4. 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 CA08104001E For more information, visit: www.eaton.com/consultants 33.4-2 Uninterruptible Power Systems Eaton Software and Connectivity September 2011 Sheet 33 086 Eaton LanSafe 22 Eaton LanSafe Application Focus Monitoring Advanced computer shutdown capabilities Basic UPS monitoring and management Local and networked single- or three-phase Eaton UPSs Third-party UPS support via USB HID and SNMP (RFC1628) standards 23 24 25 Key Product Features 26 27 28 29 30 31 32 33 34 35 36 37 38 Eaton LanSafe General Description LanSafe Power management software provides automatic, unattended and graceful shutdown of computer systems throughout the network during an extended power outage. It continuously monitors the UPSs status and automatically notifies defined users locally and remotely about UPS events. LanSafe can be setup to shutdown a large group of computers running multiple operating systems (e.g. Linux, UNIX, Windows, Novell). It's exclusive SafetyNetTM technology enables network administrators to establish a user-defined sequential shutdown so that the most critical equipment (such as database or file servers) is shut down last, after work in progress is saved from client workstations through hubs, switches, routers and communication servers. With event notification, one can specify unique text messages associated with each alarm, and to which users the alarms are broadcasted over the network. For remote alarms, the software can initiate an e-mail message to immediately notify users about a power problem. 42 In addition, LanSafe provides as standard the ability to send SNMP traps to any SNMP compliant network management system (NMS) like HP-OpenView or CiscoWorks 2000. LanSafe also supports the `GET' and `SET' SNMP commands, which allows the NMS administrator to periodically enquire all metering information such as input voltage, output voltage, battery health and runtime among others. 43 LanSafe software is bundled freeof-charge with all Eaton UPSs on the software suite CD-ROM. 39 40 41 Automatically performs a graceful shutdown of the computer system and saves work-in-progress during an extended power outage Displays vital UPS information with an intuitive, graphic format for non-technical personnel Broad OS support: Compiles a full year of UPS events with a graphical calendar view Communicates UPS status change messages via e-mail, pager or cell phone to keep you informed at all times Notifies you in advance that it is time to hot-swap your batteries so that your UPS is ready for the next power outage Saves electricity and adds security with automatic power-on and power-off scheduling capability Helps you determine how much money the UPS and LanSafe is saving you during every power failure due to prevented downtime with a cost savings calculator Runs invisibly with stealth mode operation, which is particularly useful when integrating LanSafe into a POS, ATM or other environment where discretion is necessary Remotely recycles power of hung-up hubs, routers and computer systems with UPS power on/off capability Monitoring LanSafe can monitor a single UPS at a time via the ControlRoom (screenshot above) or PowerScope views. Other LanSafe installations on the network can be selected for monitoring and management via the file-open controller option. Communication--Input/Output RS-232 USB ConnectUPS Web/SNMP Ethernet network connection SNMP via RFC1628 standard Notification Notification Requirements Eaton UPS with contact closure, serial, USB or connect UPS network communications Third-party UPS support via USB HID and SNMP (RFC1628) standards Supported computer operating system, current list available at http://www.powerware.com/ Software/Lansafe5.asp Configured SMTP server for e-mail notifications Computer system supporting minimum system requirements: 200 MHz CPU, 32MB RAM, 30MB HD, SVGA monitor For more information, visit: www.eaton.com/consultants Personalized UPS Alarm notifications Local event message notification Network broadcasts E-mail Command execution SNMP traps SNMP proxy agent (GET and SET capability) Computer Shutdown Sequential SafetyNet shutdown ensures that all network transactions are completed prior to shutdown. Workstations are shut down first, internet working equipment is shut down next and Servers are shut down last. CA08104001E Uninterruptible Power Systems Eaton Software and Connectivity September 2011 33.4-3 Sheet 33 087 Eaton LanSafe Load Segment Control Data Archiving/Analysis 22 23 24 25 26 Load Segment Control Doubles the run time for mission critical loads. Turns separate load segments (receptacle groups) on and off at predefined times, or automatically during power outage events. In addition load segments can be turned off and back on again manually over the network or locally. Diagnostics Data Archiving/Analysis The history data summary displays a cumulative tally of system events that have occurred since LanSafe was installed. View input, output voltage, output load and battery voltage measurement changes over a period of time in a crisp clear graphic diagram format. Integration 27 28 29 30 31 32 33 34 Diagnostics LanSafe reminds the user ahead of time when the UPS batteries need to be replaced. The Test Hardware option performs a diagnostic test to verify your UPS is functioning properly. The tests provide information about the UPS battery and internal circuitry and can be initiated either locally or remotely. Integration NMS (network management systems, e.g., HP-OpenView, IBM Tivoli, CA-Unicenter, Cisco 2000) via SNMP PowerVision network edition for viewing all LanSafe installations on the network Other systems via command execution 35 36 37 38 39 40 41 42 43 CA08104001E For more information, visit: www.eaton.com/consultants 33.4-4 Uninterruptible Power Systems Eaton Software and Connectivity September 2011 Sheet 33 088 MultiView and IBM Director 22 Eaton MultiView Eaton Extensions for IBM Director 23 24 25 26 Eaton MultiView 27 28 29 General Description Windows-based Web browser for monitoring multiple Eaton UPSs via ConnectUPS Web cards and LanSafe v. 5 instances. Application Focus 30 31 Key Product Features 32 33 34 35 36 37 38 39 40 41 42 Basic network device monitoring Multiple single- or three-phase Eaton UPSs Simple monitoring for multiple UPSs connected via ConnectUPS Web/SNMP card and/or LanSafe v. 5 Status@aGlanceTM monitoring capability Drill down access to web page details (ConnectUPS Web/SNMP card only) Allows user to view multiple web sites simultaneously within a single browser window Searches for and automatically adds browser pages of connected ConnectUPS Web/SNMP cards as well as the Status@aGlance monitoring feature from the Eaton LanSafe v. 5 software Eaton Extensions for IBM Director General Description Plug-in software for IBM director network management system that allows network system administrators to monitor, diagnose, configure, set alarms, schedule self-tests, check battery, gather inventory information, and control Eaton UPSs network-wide from a single console within IBM director. Application Focus Network management system integration Multiple single- or three-phase Eaton UPSs Key Product Features Network monitoring and control software for all UPSs in the network UPS control and power management for IBM director system administrators Seamless integration of UPSs into the IBM director management console UPS Inventory management Central log for UPS events Requirements Eaton UPS Windows operating system Eaton connectivity device, e.g., serial card or ConnectUPS Web/SNMP Requirements Primary computer running IBM director version 5.1. Integration Installing the Eaton extensions for IBM director enables the user to easily and automatically integrate Eaton UPSs into the IBM director environment. 43 For more information, visit: www.eaton.com/consultants CA08104001E September 2011 Uninterruptible Power Systems Eaton Software and Connectivity 33.4-5 Sheet 33 089 NetWatch/Modbus Profiler/Intelligent Power Eaton NetWatch Eaton Modbus Profiler General Description General Description NetWatch client UPS software enables users to shutdown a server or workstation and acts as a networkmonitoring tool through the Eaton ConnectUPS-X, ConnectUPS-BD or BestLink SNMP/WEB Adapter connectivity devices. During an extended power outage, the SNMP/ WEB adapter informs all registered NetWatch clients to shut down their respective operating systems, thus preparing them for the removal of AC power. Profiler is a power management and UPS software tool that creates a Modbus register map for a particular Eaton UPS. It reads the available parameters in a UPS and compares them with a list of universally supported Modbus parameters. If the parameter in the UPS and parameter in the master list both exist, then the Profiler program reports the supported parameter. Intelligent Power Software Suite 22 23 24 25 26 27 Application Focus Basic network device monitoring Multiple single- or three-phase Eaton UPSs Intelligent Power Software Suite General Description The Intelligent Power(R) Software Suite CD ships with Eaton UPSs and delivers the latest power monitoring and management software. This software works in conjunction with your UPSs and other power devices to provide a total power solution for your network. Perfect for virtualized environments, the software suite even integrates seamlessly with VMware's vCenter ServerTM and Microsoft's SCVMMTM. Key Product Features Shutdown up to 255 computers dependent upon power from a Eaton UPS Popup messaging on Windows to notify UPS on battery conditions Requirements Eaton UPS Computer or server running an operating system supported by CoreLogic UPS-native or Eaton X-Slot communications supporting serial, USB or SNMP 28 29 30 31 32 33 34 35 Shutdown 36 Computer shutdown is achieved through the use of NetWatch software. The shutdown message is sent in the form of a network broadcast from the ConnectUPS or BestLink connectivity card to all available NetWatch clients on the network. In the event of a power failure all clients are notified to shutdown based upon their local settings. 37 38 39 40 41 42 43 CA08104001E For more information, visit: www.eaton.com/consultants 33.4-6 Uninterruptible Power Systems Eaton Software and Connectivity September 2011 Sheet 33 090 Power Xpert Gateway UPS Card 22 23 Power Xpert Gateway UPS Card--Uninterruptible Power Supplies Features Information is presented in organized, user-friendly Web pages and includes the following: 24 25 26 27 28 29 30 31 Power Xpert Gateway UPS Card General Description The Power Xpert Gateway UPS Card (PXGX UPS) provides Web-enabled, real-time monitoring of Powerware Uninterruptible Power Supplies (UPS) through standard on-board Web pages, Power Xpert Software or third-party software. An integral part of the Power Xpert Architecture, which provides end-toend PowerChain solutions, the PXGX UPS provides a central point to connect distribution products to an Ethernet network. UPS system identification Voltage Current Frequency Energy Output Power Power--full load % Battery information History and maintenance Run time remaining Voltage % battery left For full details on the Power Xpert Gateway UPS card, see Tab 2, Section 2.3. 32 33 34 35 36 37 38 39 40 41 42 43 For more information, visit: www.eaton.com/consultants CA08104001E Uninterruptible Power Systems Eaton Software and Connectivity September 2011 33.4-7 Sheet 33 091 ConnectUPS Web/SNMP Products ConnectUPS Web/ SNMP Products ConnectUPS Web/SNMP Products General Description The Eaton ConnectUPS Web/SNMP product family provides seamless Eaton UPS integration into the Ethernet network and the Internet. The built-in Web server allows the users to monitor and manage the UPSs through the ConnectUPS via a standard Web browser. HTTP, SNMP, SMTP, WAP, Telnet compatibility and a console port enable dynamic and versatile support for a large variety of system configurations. Logs and graphs detailed historical data to analyze trends Uses standard communication protocols on 10 Mb and 100 Mb Ethernet networks Performs as a switching hub for three 10/100Mbps connections (ConnectUPS-X) Enables orderly shutdown and restart of remote UPSs Supports optional Eaton environmental monitoring probe (EMP) for temperature, humidity and other contact sensor monitoring, management User Interface support for local languages (English, Chinese, Spanish, French, German, Italian, other Interworks with optional Eaton probe to monitor environmental conditions: temperature and humidity at remote sites Supports in-service installation and upgrades without interrupting critical loads (most UPS models) Event Notification When used in conjunction with NetWatch client software, the ConnectUPS products also provide graceful shutdown of operating systems of up to 255 computers powered by a single UPS. ConnectUPS products send real-time alert notifications to four designated recipients via e-mail, PCS mobile phone, or pager, and via SNMP traps to an NMS or network messaging to Eaton NetWatch software. Each recipient has the option of receiving real-time event messages, daily status reports based on criticality, containing data and event log files, or a combination of routine reports and event notifications. Application Focus Monitoring Ethernet, Internet connectivity device Graceful shutdown functionality when used in conjunction with NetWatch power management software Integration to standard SNMP, HTTP, WAP, SMTP compliant applications 10/100 Ethernet 3-port switching hub (ConnectUPS-X model only) HTTP SNMP SMTP WAP Telnet Management From a Web browser or NMS, which may be hundreds or thousands of miles away, a system administrator can shut down or reboot a remote UPS, perform remote UPS battery tests, and set up scheduled shutdowns of UPSs and associated servers. Monitoring Gain up-to-the-minute assurance that computing and communication. systems are receiving the continuous, clean power they demand. Through easily navigable Web pages, network administrators can check system status and view critical meter information, such as input and output voltage, UPS load, battery voltage and condition, at any time. For more information, visit: www.eaton.com/consultants 22 23 24 25 26 27 28 29 30 The ability to shut down or restart systems without a site visit dramatically reduces field service expense and response time. Scheduled shutdowns can be devised to conserve power or tighten security during specific time periods, such as evenings or weekends. 31 Integration 34 Network management systems (NMS) via SNMP Mobile phones via WAP Optional EMP (environmental monitoring probe) for temperature and humidity monitoring 32 33 Turns separate load segments (receptacle groups) on and off at predefined times, or automatically during power outage events. In addition load segments can be turned off and back on again manually over the network or locally. CA08104001E Communication--Input/Output Load Segment Control Key Product Features Supports real-time monitoring and control of UPSs across the network Enables monitoring and control via Web browsers, SNMP-compliant network management systems or power management software Delivers alarm notifications through e-mail, to mobile phones, pagers, or SNMP traps Enables rapid identification and analysis of critical power conditions ConnectUPS-X, ConnectUPS-BD, and ConnectUPS-E products have built-in data and event logs that track and record specific power-related occurrences over time, at user-defined increments as fine as one-minute intervals. 35 36 37 38 39 40 41 42 43 33.4-8 Uninterruptible Power Systems Eaton Software and Connectivity September 2011 Sheet 33 092 ConnectUPS Web/SNMP and Relay Products 22 23 24 Relay Products Information Tables Table 33.4-1. Technical Specifications Model ConnectUPS-X ConnectUPS-BD ConnectUPS-E Description Card providing remote monitoring and control of Eaton UPSs BestLink Protocol support http, SNMP, TFTP, Telnet, BootP, DHCP, WAP, ARP, RARP PS slot type X-Slot BestDock External External Network support Ethernet 10/100Base-T 25 Switching hub Yes (three 10/100Base-T connections) Yes 26 Temperature and humidity monitoring UPS compatibility See chart below 27 28 29 30 31 32 33 General Description Supported MIB UPS standard MIB RFC-1628, Eaton MIB, MIB II, 2003 ?/S supported or shutdown Microsoft Windows 9X, ME, 2000/NT and XP, Various UNIX (including Linux) Versions, Novell NetWare, Macintosh Operating temperature 0-40C Operating humidity 10-80%, noncondensing BestLink MIB Power input 9 Vdc unregulated Power consumption 3.5 watts 12V unregulated Dimensions in inches (mm) 4.70 x 4.50 x 1.50 5.30 x 3.20 x 1.30 5.30 x 3.40 x 1.10 5.30 x 3.40 x 1.10 (119.4 x 114.3 x 38.1) (134.6 x 81.3 x 33.0) (134.6 x 86.4 x 28.00) (134.6 x 86.4 x 28.0) Weight 6 oz. Regulatory FCC Class B 4 oz. 6 oz. 6 oz. Eaton relay interface cards enable automatic shutdown and network monitoring of Eaton UPS system status through a connected computer. The relay interface cards are available in two models, the X-Slot version and BestDock version. Both are dedicated adapters that provide the essential dry-contact interface between an Eaton UPS and any relay-connected computer, including the IBM AS/400, as well as a variety of industrial applications. Application Focus Basic network device monitoring Multiple single- or three-phase Eaton UPSs Single UPS and parallel systems (single/three phase UPS) Table 33.4-2. ConnectUPS/Eaton UPS Compatibility Model Part Number Eaton UPSs Environmental Monitoring Probe X-Slot ConnectUPS-X Kit 116750221-001 5115 RM, 5125, 9125, 9320, 9330, 9335, 9340, and 9390 via expansion chassis: 9120, 9170+, 9315 Yes 34 35 Relay Products No Key Product Features Best dock ConnectUPS-BD kit 116750222-001 9120 and 9170+ Yes ConnectUPS-E kit 116750223-001 9150 and 9305 Yes Best Link Web/SNMP Kit 116750225-001 FERRUPS -- 36 37 38 Simple integration with building and security alarm systems Compatibility with simple shutdown methods, i.e., IBM AS/400 and Windows UPS service Option available for all UPS models excluding 3110,3115, 5115 (tower) models Isolated Form-C relay contacts Compatibility with simple shutdown methods, i.e., IBM AS/400 and Windows UPS service Requirements 39 40 Compatible Eaton UPS IBM AS/400 cable to connect between DB-15 port on card to computer 41 42 43 For more information, visit: www.eaton.com/consultants CA08104001E Uninterruptible Power Systems Eaton Software and Connectivity September 2011 33.4-9 Sheet 33 093 Relay and Serial Protocol Products Serial Protocol Products Monitoring Monitoring is accomplished though the use Eaton relay products that provide alarm information via Form-C dry contacts that are connected the customer alarm panel. Multi-Server Card Integration Simple integration with building management systems or building alarm systems can be achieved by connecting the Form-C dry contact outputs from the relay product to the digital inputs on the I/O controller provided by the BMS or security alarm vendor. Ordering Information Table 33.4-3. Ordering Information Product Name Part Number Relay card (X-Slot) Relay card (BD) Relay interface adapter Industrial relay card 1018460 1014018 103001185-002 103003055 Management/Shutdown IBM AS/400 computer shutdown is achieved by using the computer port on the Eaton relay cards for use with all X-Slot compatible UPS models along with the appropriate cable. For information on AS/400 cables available for all relay products please refer to either the Eaton single- or three-phase UPS price lists. Key Product Features Multi-Server Card General Description The multi-server card is a power quality connectivity product designed to enable multiple devices connected to a single UPS system to be managed and controlled independently. This multi-server card is designed to function with any Eaton UPS that has an X-Slot communication device, and is also compatible with Eaton expansion chassis. The multi-server card has six serial ports, three of which correspond with the multiple load segments of your Eaton UPS. By using multiple serial cables and LanSafe software, you can perform simultaneously yet independent monitoring and control of up to six servers with a mixture of operating systems. Multiple serial ports provide greater power management control and flexible monitoring LanSafe compatibility provides simultaneous monitoring of computer loads Allows user to configure each server to provide a graceful shutdown at the optimum time desired Works with multiple operating systems Independent control of serial ports gives load shedding capability for maximum runtime of critical loads Simultaneously provides RS-232 monitoring and relay output monitoring Plug and Play (PnP) protocol for easy configuration Monitoring Monitoring is achieved through RS-232 serial communications between the connectivity device and the host computer running LanSafe. Table 33.4-4. Technical Specifications-- Dimensions in Inches (mm) 23 24 25 26 27 28 29 30 31 32 Part Number 05146447-5502 Description X-Slot card with multiple Serial connections for serial communications with Eaton UPS UPS compatibility PW 5125, PW 9125, PW 9330, PW 9340, expansion chassis Serial cable PN 124102022-002 O/S supported for shutdown All O/S supported by Eaton Lan Safe operating temperature 0-40C 36 Operating humidity 10-80% noncondensing 37 Power input 9 Vdc unregulated Application Focus Single UPS module and parallel systems (single/three-phase UPS) 22 Power consumption 1.5 Walls LxWxH 4.7 x 4.5 x 1.5 (120 x 114 x .39) Weight 7 oz. Regulatory FCC Class A 33 34 35 38 39 40 41 42 43 CA08104001E For more information, visit: www.eaton.com/consultants 33.4-10 Uninterruptible Power Systems Eaton Software and Connectivity September 2011 Sheet 33 094 Serial Protocol Products 22 Eaton Modbus Card 23 Compatible with common BMS platforms such as: Siemens Apogee, JCI Metasys, Honeywell EBI, Liebert SiteScan, and Invensys Climate Controls Requirements 24 Eaton expansion chassis required for UPS models without communication slots. 25 26 Eaton Modbus Card Integration UPS data is easily integrated into the building management system by connecting the UPS into the RS-485 power and environmental device network which in turn gets converted to Ethernet for easy access by the BMS host computer running the management software. Table 33.4-5. Ordering Information Note: Modbus Card is included with the expansion chassis as standard. General Description 27 28 29 30 31 32 33 35 Application Focus Table 33.4-6. Technical Data and Specifications Single UPS module and parallel systems (single/three-phase UPS) BMS/IAS integration Key Product Features 38 40 41 42 43 103002510-5501 Figure 33.4-1. Typical Configurations and Installation Methods 36 39 Modbus Card The card provides the means to integrate data from the Eaton UPS into the user-provided management system using Modicon(R) Modbus RTU protocol. Key power quality and UPS status information may be monitored in real-time to aid in the management of the UPS and notification of potential power problems. 37 Part Number The Eaton Modbus Card is an X-Slot Eaton UPS connectivity device that provides continuous, reliable and accurate remote monitoring of a Eaton UPS system through a building management system (BMS) or industrial automation system (IAS). 34 Product Name Real-time monitoring of power conditions through building management systems (BMS) Supports Modbus RTU/Jbus protocol Seamless data integration via included Profiler software package Flexible input/output communication methods: RS-232 and RS-485 multi-drop (network) Optically isolated communication ports User-selectable communication topologies Supports wide range of UPSs via native Eaton X-Slot UPSs or via Eaton expansion chassis Eaton Modbus profiler utility provides exact UPS parameter list (register map) for BMS data integration Supports both commands 02 (read input status) and 04 (read input register) from a BMS query Part Number 103002510-5501 Description X-Slot card providing integration with Modbus network and monitoring of associated UPS through building management system (BMS) Modbus command support Read input status (alarms and status points, function 02) read input register (meters, function 04) Profiler Automatically generates Modbus register map for each UPS (Windows 32 application) Configuration Via VT-100 terminal emulation through DB-9 port Baud rate Selectable 1200 to 19.2 k Slave address Selectable 1 to 247 Network connections RS-485 through isolated terminal block or DB-9 port RS-232 through DB-9 port Communications topology Selectable two-wire or four-wire Additional hardware features Selectable termination resistance Selectable polarity resistance UPS compatibility via native X-Slot Eaton 5125, 9125, 9170+, 9330, 9340, 9390 UPS compatibility via expansion chassis Eaton Prestige 9 Eaton 5115 Eaton 9315 Hot Sync parallel redundant module Eaton Plus 12, 18, 36 Eaton 9120 Eaton 9315 Hot Sync parallel capacity UPM; Eaton 9315 reverse transfer module Eaton 9170+ Eaton 9315 Hot Sync parallel capacity SBM Operating temperature 10 to 40C Operating humidity 20-80% relative humidity (noncondensing) Power input 9 Vdc unregulated Power consumption 1.5 Watts Dimensions in inches (mm) 4.70 L x 4.50 W x 1.50 H (119.4 L x 114.3 W x 38.1 H) Weight 7 oz Regulatory FCC Class B For more information, visit: www.eaton.com/consultants CA08104001E Uninterruptible Power Systems Eaton Software and Connectivity September 2011 33.4-11 Sheet 33 095 Serial Protocol Products Expansion Chassis Two additional slots are available for use with any of the following cards: A ConnectUPSTM-X SNMP/Web adapter--monitor via SNMP or the Web A ConnectUPS-M SNMP module-- monitor via simple network management protocol (SNMP) Expansion Chassis General Description The expansion chassis is a three-slot power quality peripheral device that expands communication methods for a UPS through its support for X-Slot cards. It comes pre-configured with a card that conforms to the Modicon, Modbus protocol. A single port serial card--connect an additional server for monitoring and graceful shutdown A multi-server card--connect up to three servers for monitoring and graceful shutdown, supports load segment control and RS-232 signals for low battery and AC fail A Modbus card--connect to another Modbus network, monitor via BMS 29 30 Figure 33.4-2. Typical Configuration 31 Table 33.4-7. Technical Data Part Number 05147063 Description Adds Modbus card plus two additional slots for X-Slot communication cards to supported UPSs Included card Modbus card Optional cards ConnectUPS-Web/SNMP-X xHub card ConnectUPS-M SNMP module 32 33 34 Single port serial card Multi-server card Additional Modbus card Communication with UPS DB-9 via Included serial cable UPS compatibility Eaton 5115; Eaton 5125; Eaton 9120; Eaton 9125; Eaton 9155; Eaton 9170+; Eaton Prestige 9; Eaton Plus 12, 18, 36; Eaton 9315 Reverse Transfer Module; Eaton 9315 Hot Sync Parallel Redundant Module; Eaton 9315 Hot Sync Parallel Capacity UPM; Eaton 9315 Hot Sync Parallel Capacity SBM; Eaton 9320; Eaton 9335; Eaton 9390 Integration The expansion chassis and associated cards effectively act as a protocol converter easily integrating the Eaton UPS into open architecture management systems. This device may be placed on or close to the associated UPS system using the included mounting feet. The kit includes brackets for rack and wall mounting. 25 28 Single UPS module and parallel systems (single/three-phase UPS) Creates wide array of communication options for UPSs Primary focus on Eaton 9315 UPS models to enable use of new X-Slot communication cards Acts as the framework for protocol conversion via compatible X-Slot cards to: Modbus; SNMP; HTTP Built-in Modbus card provides integration of UPS information into building management systems Compatible with X-Slot cards: Modbus card (one included); ConnectUPS-X SNMP/Web adapter; ConnectUPS-M SNMP module; single port serial card; multiserver card Flexible mounting options Redundant power inputs 24 27 Key Product Features 23 26 Application Focus 22 Mounting Stand-alone (ft), rack (19 inches, 483 mm), or wall mount Operating temperature 10 to 40C Operating humidity 20 to 80% relative humidity (noncondensing) Power input Switchable 230/120 Vac, 50/60 Hz (via included transformer) Power consumption 6 watts maximum Dimensions in inches (mm) 18.00 x 1.75 x 6.00 (457.2 x 44.4 x 152.4) Weight 6 lbs (including 1 lb for power supply) Regulatory FCC Class B 35 36 37 38 39 40 41 42 43 CA08104001E For more information, visit: www.eaton.com/consultants 33.4-12 Uninterruptible Power Systems September 2011 Sheet 33 096 22 This page intentionally left blank. 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 For more information, visit: www.eaton.com/consultants CA08104001E