CA08104001E For more information, visit: www.eaton.com/consultants
33.4-1
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
Power Xpert Software
085
Power Xpert® Software
General Description
Power Xpert Software aggregates the
information arriving from different
types of device families via various
communication methods. Its unique
Web-based design, alarm bubble-up,
and advanced trend and waveform
analysis tools help you to quickly turn
your attention to the most important
events and to identify reliability issues
and cost-saving opportunities. The
standard custom graphic package, the
Layout Manager, with an icon library
and standard vertical templates,
allows you to import and mimic your
physical environment and gauges.
Open protocol support makes Power
Xpert Software compatible with most
newer generation third-party equip-
ment. Older legacy, proprietary
protocols are supported by Power
Xpert Gateways, and custom software
drop-in drivers made available by
Eaton. Power Xpert Software is the
first power system software of this
caliber to put all of these powerful
features at your ngertips.
Power Xpert Software provides an
easy upgrade path to allow existing
PowerNet users to enjoy the benets
of power monitoring through a simple
Web browser interface.
Power Xpert is a complete software
solution to manage your power
system. Critical components such as
metering devices, protective relays,
circuit breaker trip units, motor
starters and uninterruptible power
supplies communicate vital informa-
tion about the health and status of
critical infrastructure devices.
Product Selection Guide
Power Xpert Software Professional Edition
Geared toward end users, with built-
in support for Eaton power distribu-
tion products such as switchgear,
UPSs, breakers, PDUs, RPPs,
meters, relays, VFDs and MCCs,
among others
Eaton products connect with the
software directly via an Ethernet
connection, while legacy devices
use a Power Xpert Gateway to Web-
enable their communications
A subset of third-party meters and
devices are supported as standard
via the gateway connection
Power Xpert Software Enterprise Edition
Geared toward advanced power
users, system integrators and enter-
prises with heterogeneous device
spectrum and system developers
who can take advantage of the
included SNMP and Modbus
integration development utilities
Extensive support for third-party
devices via standard SNMP and
Modbus TCP protocols
Large variety of ready made,
optional third-party drop-in
drivers available
Features
Connects to your existing network
Data trending and graphing for
detailed information for trouble-
shooting, problem prevention and
costs savings
Web-based views that allow access
to critical information from any
location via a Web browser
A modular, scalable architecture
that allows the addition of capabili-
ties and devices as the power
system expands
Alarm conditions bubble up through
the system to allow personnel to
identify which device is in alarm and
where it is located
All the functionality of Eatons
PowerNet software suite
Connectivity to a wide range of
Eaton and third-party devices. For a
full list of compatible devices, refer
to the hardware compatibility list
found at www.eaton.com/pxs
For full details on Power Xpert
Software, refer to Tab 2, Section 2.4.
Foreseer® Services
Foreseer Software and Engineering
Services (Foreseer Services) provide
vendor independent, power and
energy infrastructure integration
solutions that help companies reduce
energy consumption and unplanned
downtime due to the failure of critical
power, environmental, safety or
security systems.
Turnkey software and connectivity
solutions are coupled with state-of-
the-art project management, systems
design, third-party device integration,
testing and custom application devel-
opment to develop a comprehensive
monitoring solution to meet your
custom needs.
Foreseer Services is delivered in
categories, offering a multitude of
unique value-add services that you
can discuss with your Eaton sales
professional.
Design services
Installation services
Commissioning services
Follow-up services
Hardware services
Software services
Foreseer Services is fully distributable
to allow different monitoring capabili-
ties to be deployed at different sites,
allowing you to purchase only what is
needed. Many competitive systems
offer a one-size-fits-all type approach
where you end up paying for more
capacity than is needed. With Foreseer
Services, you pay only for what you
need, when you need it.
For full details on Foreseer Services,
refer to Tab 2, Section 2.4.
33.4-2
For more information, visit: www.eaton.com/consultants CA08104001E
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
Eaton LanSafe
086
Eaton LanSafe
Eaton LanSafe
General Description
LanSafe Power management software
provides automatic, unattended and
graceful shutdown of computer
systems throughout the network
during an extended power outage.
It continuously monitors the UPSs
status and automatically noties
defined users locally and remotely
about UPS events.
LanSafe can be setup to shutdown
a large group of computers running
multiple operating systems (e.g. Linux,
UNIX, Windows, Novell). Its exclusive
SafetyNet™ technology enables
network administrators to establish
a user-defined sequential shutdown
so that the most critical equipment
(such as database or le servers) is
shut down last, after work in progress
is saved from client workstations
through hubs, switches, routers
and communication servers.
With event notication, one can specify
unique text messages associated with
each alarm, and to which users the
alarms are broadcasted over the
network. For remote alarms, the
software can initiate an e-mail message
to immediately notify users about a
power problem.
In addition, LanSafe provides as
standard the ability to send SNMP
traps to any SNMP compliant network
management system (NMS) like
HP-OpenView or CiscoWorks 2000.
LanSafe also supports the ‘GET’ and
‘SET’ SNMP commands, which allows
the NMS administrator to periodically
enquire all metering information such
as input voltage, output voltage, bat-
tery health and runtime among others.
LanSafe software is bundled free-
of-charge with all Eaton UPSs
on the software suite CD-ROM.
Application Focus
Advanced computer shutdown
capabilities
Basic UPS monitoring and
management
Local and networked single- or
three-phase Eaton UPSs
Third-party UPS support via USB
HID and SNMP (RFC1628) standards
Key Product Features
Automatically performs a graceful
shutdown of the computer system
and saves work-in-progress during
an extended power outage
Displays vital UPS information
with an intuitive, graphic format for
non-technical personnel
Broad OS support:
Compiles a full year of UPS events
with a graphical calendar view
Communicates UPS status change
messages via e-mail, pager or
cell phone to keep you informed
at all times
Noties you in advance that it is time
to hot-swap your batteries so that
your UPS is ready for the next
power outage
Saves electricity and adds security
with automatic power-on and
power-off scheduling capability
Helps you determine how much
money the UPS and LanSafe is
saving you during every power
failure due to prevented downtime
with a cost savings calculator
Runs invisibly with stealth mode
operation, which is particularly
useful when integrating LanSafe into
a POS, ATM or other environment
where discretion is necessary
Remotely recycles power of hung-up
hubs, routers and computer systems
with UPS power on/off capability
Requirements
Eaton UPS with contact closure,
serial, USB or connect UPS
network communications
Third-party UPS support via USB
HID and SNMP (RFC1628) standards
Supported computer operating
system, current list available
at http://www.powerware.com/
Software/Lansafe5.asp
Configured SMTP server for e-mail
notifications
Computer system supporting
minimum system requirements:
200 MHz CPU, 32MB RAM, 30MB
HD, SVGA monitor
Monitoring
Monitoring
LanSafe can monitor a single UPS at a
time via the ControlRoom (screenshot
above) or PowerScope views. Other
LanSafe installations on the network
can be selected for monitoring and
management via the file-open
controller option.
Communication—Input/Output
RS-232
USB
ConnectUPS Web/SNMP Ethernet
network connection
SNMP via RFC1628 standard
Notification
Notification
Personalized UPS Alarm notifications
Local event message notification
Network broadcasts
E-mail
Command execution
SNMP traps
SNMP proxy agent (GET and
SET capability)
Computer Shutdown
Sequential SafetyNet shutdown
ensures that all network transactions
are completed prior to shutdown.
Workstations are shut down first,
internet working equipment is shut
down next and Servers are shut
down last.
CA08104001E For more information, visit: www.eaton.com/consultants
33.4-3
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
Eaton LanSafe
087
Load Segment Control
Load Segment Control
Doubles the run time for mission
critical loads. Turns separate load
segments (receptacle groups) on and
off at predefined times, or automati-
cally during power outage events.
In addition load segments can be
turned off and back on again manually
over the network or locally.
Diagnostics
Diagnostics
LanSafe reminds the user ahead of
time when the UPS batteries need to
be replaced.
The Test Hardware option performs a
diagnostic test to verify your UPS is
functioning properly. The tests provide
information about the UPS battery and
internal circuitry and can be initiated
either locally or remotely.
Data Archiving/Analysis
Data Archiving/Analysis
The history data summary displays
a cumulative tally of system events
that have occurred since LanSafe
was installed.
View input, output voltage, output
load and battery voltage measurement
changes over a period of time in a
crisp clear graphic diagram format.
Integration
Integration
NMS (network management
systems, e.g., HP-OpenView,
IBM Tivoli, CA-Unicenter,
Cisco 2000) via SNMP
PowerVision network edition for
viewing all LanSafe installations
on the network
Other systems via command
execution
33.4-4
For more information, visit: www.eaton.com/consultants CA08104001E
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
MultiView and IBM Director
088
Eaton MultiView
Eaton MultiView
General Description
Windows-based Web browser for
monitoring multiple Eaton UPSs
via ConnectUPS Web cards and
LanSafe v. 5 instances.
Application Focus
Basic network device monitoring
Multiple single- or three-phase
Eaton UPSs
Key Product Features
Simple monitoring for multiple
UPSs connected via ConnectUPS
Web/SNMP card and/or LanSafe v. 5
Status@aGlance™ monitoring
capability
Drill down access to web page
details (ConnectUPS Web/SNMP
card only)
Allows user to view multiple web
sites simultaneously within a single
browser window
Searches for and automatically
adds browser pages of connected
ConnectUPS Web/SNMP cards
as well as the Status@aGlance
monitoring feature from the
Eaton LanSafe v. 5 software
Requirements
Eaton UPS
Windows operating system
Eaton connectivity device,
e.g., serial card or ConnectUPS
Web/SNMP
Eaton Extensions
for IBM Director
Eaton Extensions for IBM Director
General Description
Plug-in software for IBM director
network management system that
allows network system administrators
to monitor, diagnose, configure, set
alarms, schedule self-tests, check
battery, gather inventory information,
and control Eaton UPSs network-wide
from a single console within
IBM director.
Application Focus
Network management system
integration
Multiple single- or three-phase
Eaton UPSs
Key Product Features
Network monitoring and control
software for all UPSs in the network
UPS control and power manage-
ment for IBM director system
administrators
Seamless integration of UPSs
into the IBM director management
console
UPS Inventory management
Central log for UPS events
Requirements
Primary computer running IBM
director version 5.1.
Integration
Installing the Eaton extensions for IBM
director enables the user to easily and
automatically integrate Eaton UPSs
into the IBM director environment.
CA08104001E For more information, visit: www.eaton.com/consultants
33.4-5
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
NetWatch/Modbus Profiler/Intelligent Power
089
Eaton NetWatch
General Description
NetWatch client UPS software
enables users to shutdown a server
or workstation and acts as a network-
monitoring tool through the Eaton
ConnectUPS-X, ConnectUPS-BD
or BestLink SNMP/WEB Adapter
connectivity devices. During an
extended power outage, the SNMP/
WEB adapter informs all registered
NetWatch clients to shut down their
respective operating systems, thus
preparing them for the removal of
AC power.
Application Focus
Basic network device monitoring
Multiple single- or three-phase
Eaton UPSs
Key Product Features
Shutdown up to 255 computers
dependent upon power from a
Eaton UPS
Popup messaging on Windows to
notify UPS on battery conditions
Requirements
Eaton UPS
Computer or server running
an operating system supported
by CoreLogic
UPS-native or Eaton X-Slot
communications supporting
serial, USB or SNMP
Shutdown
Computer shutdown is achieved
through the use of NetWatch software.
The shutdown message is sent in the
form of a network broadcast from the
ConnectUPS or BestLink connectivity
card to all available NetWatch clients
on the network. In the event of a
power failure all clients are notified
to shutdown based upon their
local settings.
Eaton Modbus Profiler
General Description
Profiler is a power management
and UPS software tool that creates a
Modbus register map for a particular
Eaton UPS. It reads the available
parameters in a UPS and compares
them with a list of universally sup-
ported Modbus parameters. If the
parameter in the UPS and parameter
in the master list both exist, then
the Profiler program reports the
supported parameter.
Intelligent Power
Software Suite
Intelligent Power Software Suite
General Description
The Intelligent Power® Software Suite
CD ships with Eaton UPSs and delivers
the latest power monitoring and
management software. This software
works in conjunction with your UPSs
and other power devices to provide a
total power solution for your network.
Perfect for virtualized environments,
the software suite even integrates
seamlessly with VMware’s vCenter
Server™ and Microsoft’s SCVMM™.
33.4-6
For more information, visit: www.eaton.com/consultants CA08104001E
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
Power Xpert Gateway UPS Card
090
Power Xpert Gateway
UPS Card—Uninterruptible
Power Supplies
Power Xpert Gateway UPS Card
General Description
The Power Xpert Gateway UPS Card
(PXGX UPS) provides Web-enabled,
real-time monitoring of Powerware
Uninterruptible Power Supplies (UPS)
through standard on-board Web
pages, Power Xpert Software or
third-party software.
An integral part of the Power Xpert
Architecture, which provides end-to-
end PowerChain solutions, the PXGX
UPS provides a central point to
connect distribution products to an
Ethernet network.
Features
Information is presented in organized,
user-friendly Web pages and includes
the following:
UPS system identification
Voltage
Current
Frequency
Energy
Output Power
Power—full load %
Battery information
History and maintenance
Run time remaining
Voltage
% battery left
For full details on the Power Xpert
Gateway UPS card, see Tab 2,
Section 2.3.
CA08104001E For more information, visit: www.eaton.com/consultants
33.4-7
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
ConnectUPS Web/SNMP Products
091
ConnectUPS Web/
SNMP Products
ConnectUPS Web/SNMP Products
General Description
The Eaton ConnectUPS Web/SNMP
product family provides seamless
Eaton UPS integration into the
Ethernet network and the Internet.
The built-in Web server allows the
users to monitor and manage the
UPSs through the ConnectUPS via
a standard Web browser.
HTTP, SNMP, SMTP, WAP, Telnet com-
patibility and a console port enable
dynamic and versatile support for a
large variety of system configurations.
When used in conjunction with
NetWatch client software, the
ConnectUPS products also provide
graceful shutdown of operating
systems of up to 255 computers
powered by a single UPS.
Application Focus
Ethernet, Internet connectivity device
Graceful shutdown functionality
when used in conjunction with
NetWatch power management
software
Integration to standard SNMP, HTTP,
WAP, SMTP compliant applications
Key Product Features
Supports real-time monitoring and
control of UPSs across the network
Enables monitoring and control via
Web browsers, SNMP-compliant
network management systems or
power management software
Delivers alarm notifications through
e-mail, to mobile phones, pagers,
or SNMP traps
Enables rapid identification and
analysis of critical power conditions
Logs and graphs detailed historical
data to analyze trends
Uses standard communication
protocols on 10 Mb and 100 Mb
Ethernet networks
Performs as a switching hub for
three 10/100Mbps connections
(ConnectUPS-X)
Enables orderly shutdown and
restart of remote UPSs
Supports optional Eaton
environmental monitoring probe
(EMP) for temperature, humidity
and other contact sensor monitor-
ing, management
User Interface support for local lan-
guages (English, Chinese, Spanish,
French, German, Italian, other
Interworks with optional Eaton
probe to monitor environmental
conditions: temperature and
humidity at remote sites
Supports in-service installation
and upgrades without interrupting
critical loads (most UPS models)
Event Notification
ConnectUPS products send real-time
alert notifications to four designated
recipients via e-mail, PCS mobile
phone, or pager, and via SNMP traps to
an NMS or network messaging to
Eaton NetWatch software. Each recipi-
ent has the option of receiving real-time
event messages, daily status reports
based on criticality, containing data and
event log files, or a combination of rou-
tine reports and event notifications.
Monitoring
Monitoring
Gain up-to-the-minute assurance that
computing and communication.
systems are receiving the continuous,
clean power they demand. Through
easily navigable Web pages, network
administrators can check system
status and view critical meter
information, such as input and
output voltage, UPS load, battery
voltage and condition, at any time.
ConnectUPS-X, ConnectUPS-BD, and
ConnectUPS-E products have built-in
data and event logs that track and
record specific power-related occur-
rences over time, at user-defined incre-
ments as fine as one-minute intervals.
Communication—Input/Output
10/100 Ethernet
3-port switching hub
(ConnectUPS-X model only)
HTTP
SNMP
SMTP
WAP
Telnet
Management
From a Web browser or NMS, which
may be hundreds or thousands of
miles away, a system administrator
can shut down or reboot a remote
UPS, perform remote UPS battery
tests, and set up scheduled shutdowns
of UPSs and associated servers.
The ability to shut down or restart
systems without a site visit dramati-
cally reduces field service expense
and response time. Scheduled
shutdowns can be devised to
conserve power or tighten security
during specific time periods, such
as evenings or weekends.
Integration
Network management systems
(NMS) via SNMP
Mobile phones via WAP
Optional EMP (environmental
monitoring probe) for temperature
and humidity monitoring
Load Segment Control
Turns separate load segments
(receptacle groups) on and off at
predefined times, or automatically
during power outage events. In
addition load segments can be turned
off and back on again manually over
the network or locally.
33.4-8
For more information, visit: www.eaton.com/consultants CA08104001E
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
ConnectUPS Web/SNMP and Relay Products
092
Information Tables
Table 33.4-1. Technical Specifications
Table 33.4-2. ConnectUPS/Eaton UPS Compatibility
Model ConnectUPS-X ConnectUPS-BD ConnectUPS-E BestLink
Description Card providing remote monitoring and control of Eaton UPSs
Protocol support http, SNMP, TFTP, Telnet, BootP, DHCP, WAP, ARP, RARP
PS slot type X-Slot BestDock External External
Network support Ethernet 10/100Base-T
Switching hub Yes (three 10/100Base-T connections) No
Temperature
and humidity
monitoring
Yes
UPS
compatibility
See chart below
Supported MIB UPS standard MIB RFC-1628, Eaton MIB, MIB II, 2003 BestLink MIB
?/S supported
or shutdown
Microsoft Windows 9X, ME, 2000/NT and XP, Various UNIX (including Linux)
Versions, Novell NetWare, Macintosh
Operating
temperature
0–40°C
Operating
humidity
10–80%, noncondensing
Power input 9 Vdc unregulated 12V unregulated
Power
consumption
3.5 watts
Dimensions in
inches (mm)
4.70 x 4.50 x 1.50
(119.4 x 114.3 x 38.1)
5.30 x 3.20 x 1.30
(134.6 x 81.3 x 33.0)
5.30 x 3.40 x 1.10
(134.6 x 86.4 x 28.00)
5.30 x 3.40 x 1.10
(134.6 x 86.4 x 28.0)
Weight 6 oz. 4 oz. 6 oz. 6 oz.
Regulatory FCC Class B
Model Part
Number
Eaton
UPSs
Environmental
Monitoring Probe
X-Slot ConnectUPS-X Kit 116750221-001 5115 RM, 5125, 9125, 9320,
9330, 9335, 9340, and 9390
via expansion chassis: 9120,
9170+, 9315
Yes
Best dock ConnectUPS-BD kit 116750222-001 9120 and 9170+ Yes
ConnectUPS-E kit 116750223-001 9150 and 9305 Yes
Best Link Web/SNMP Kit 116750225-001 FERRUPS
Relay Products
Relay Products
General Description
Eaton relay interface cards enable
automatic shutdown and network
monitoring of Eaton UPS system
status through a connected computer.
The relay interface cards are available
in two models, the X-Slot version and
BestDock version. Both are dedicated
adapters that provide the essential
dry-contact interface between an
Eaton UPS and any relay-connected
computer, including the IBM AS/400,
as well as a variety of industrial
applications.
Application Focus
Basic network device monitoring
Multiple single- or three-phase
Eaton UPSs
Single UPS and parallel systems
(single/three phase UPS)
Key Product Features
Simple integration with building and
security alarm systems
Compatibility with simple shutdown
methods, i.e., IBM AS/400 and
Windows UPS service
Option available for all UPS models
excluding 3110,3115, 5115 (tower)
models
Isolated Form-C relay contacts
Compatibility with simple shutdown
methods, i.e., IBM AS/400 and
Windows UPS service
Requirements
Compatible Eaton UPS
IBM AS/400 cable to connect
between DB-15 port on card
to computer
CA08104001E For more information, visit: www.eaton.com/consultants
33.4-9
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
Relay and Serial Protocol Products
093
Monitoring
Monitoring is accomplished though
the use Eaton relay products that
provide alarm information via Form-C
dry contacts that are connected the
customer alarm panel.
Management/Shutdown
IBM AS/400 computer shutdown is
achieved by using the computer port
on the Eaton relay cards for use with
all X-Slot compatible UPS models
along with the appropriate cable.
For information on AS/400 cables
available for all relay products please
refer to either the Eaton single- or
three-phase UPS price lists.
Integration
Simple integration with building
management systems or building
alarm systems can be achieved by
connecting the Form-C dry contact
outputs from the relay product to the
digital inputs on the I/O controller
provided by the BMS or security
alarm vendor.
Ordering Information
Table 33.4-3. Ordering Information
Serial Protocol Products
Multi-Server Card
Multi-Server Card
General Description
The multi-server card is a power
quality connectivity product designed
to enable multiple devices connected
to a single UPS system to be managed
and controlled independently.
This multi-server card is designed
to function with any Eaton UPS that
has an X-Slot communication device,
and is also compatible with Eaton
expansion chassis. The multi-server
card has six serial ports, three of which
correspond with the multiple load
segments of your Eaton UPS. By using
multiple serial cables and LanSafe
software, you can perform simulta-
neously yet independent monitoring
and control of up to six servers with
a mixture of operating systems.
Application Focus
Single UPS module and parallel
systems (single/three-phase UPS)
Key Product Features
Multiple serial ports provide greater
power management control and
flexible monitoring
LanSafe compatibility provides
simultaneous monitoring of
computer loads
Allows user to configure each server
to provide a graceful shutdown at
the optimum time desired
Works with multiple operating
systems
Independent control of serial ports
gives load shedding capability for
maximum runtime of critical loads
Simultaneously provides RS-232
monitoring and relay output
monitoring
Plug and Play (PnP) protocol for
easy configuration
Monitoring
Monitoring is achieved through
RS-232 serial communications
between the connectivity device and
the host computer running LanSafe.
Table 33.4-4. Technical Specifications—
Dimensions in Inches (mm)
Product
Name
Part
Number
Relay card (X-Slot)
Relay card (BD)
Relay interface adapter
Industrial relay card
1018460
1014018
103001185-002
103003055
Part
Number
05146447-5502
Description X-Slot card with multiple
Serial connections for
serial communications
with Eaton UPS
UPS compatibility PW 5125, PW 9125,
PW 9330, PW 9340,
expansion chassis
Serial cable PN 124102022-002
O/S supported
for shutdown
All O/S supported by
Eaton Lan Safe
operating temperature
0–40°C
Operating humidity 10–80%
noncondensing
Power input 9 Vdc unregulated
Power consumption 1.5 Walls
L x W x H 4.7 x 4.5 x 1.5
(120 x 114 x .39)
Weight 7 oz.
Regulatory FCC Class A
33.4-10
For more information, visit: www.eaton.com/consultants CA08104001E
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
Serial Protocol Products
094
Eaton Modbus Card
Eaton Modbus Card
General Description
The Eaton Modbus Card is an X-Slot
Eaton UPS connectivity device that
provides continuous, reliable and
accurate remote monitoring of a
Eaton UPS system through a building
management system (BMS) or
industrial automation system (IAS).
The card provides the means to
integrate data from the Eaton UPS
into the user-provided management
system using Modicon®‚ Modbus RTU
protocol. Key power quality and UPS
status information may be monitored
in real-time to aid in the management
of the UPS and notification of potential
power problems.
Application Focus
Single UPS module and parallel
systems (single/three-phase UPS)
BMS/IAS integration
Key Product Features
Real-time monitoring of power
conditions through building
management systems (BMS)
Supports Modbus RTU/Jbus protocol
Seamless data integration via
included Profiler software package
Flexible input/output communica-
tion methods: RS-232 and RS-485
multi-drop (network)
Optically isolated communication
ports
User-selectable communication
topologies
Supports wide range of UPSs via
native Eaton X-Slot UPSs or
via Eaton expansion chassis
Eaton Modbus profiler utility
provides exact UPS parameter
list (register map) for BMS
data integration
Supports both commands 02 (read
input status) and 04 (read input
register) from a BMS query
Compatible with common BMS
platforms such as: Siemens Apogee,
JCI Metasys, Honeywell EBI,
Liebert SiteScan, and Invensys
Climate Controls
Requirements
Eaton expansion chassis
required for UPS models without
communication slots.
Note: Modbus Card is included with the
expansion chassis as standard.
Integration
UPS data is easily integrated into the
building management system by
connecting the UPS into the RS-485
power and environmental device
network which in turn gets converted
to Ethernet for easy access by the
BMS host computer running the
management software.
Table 33.4-5. Ordering Information
Figure 33.4-1. Typical Configurations and Installation Methods
Table 33.4-6. Technical Data and Specifications
Product
Name
Part
Number
Modbus Card 103002510-5501
Part
Number
103002510-5501
Description X-Slot card providing integration with Modbus network and monitoring
of associated UPS through building management system (BMS)
Modbus command
support
Read input status (alarms and status points, function 02)
read input register (meters, function 04)
Profiler Automatically generates Modbus register map for each UPS
(Windows 32 application)
Configuration Via VT-100 terminal emulation through DB-9 port
Baud rate Selectable 1200 to 19.2 k
Slave address Selectable 1 to 247
Network connections RS-485 through isolated terminal block or DB-9 port
RS-232 through DB-9 port
Communications topology Selectable two-wire or four-wire
Additional
hardware features
Selectable termination resistance
Selectable polarity resistance
UPS compatibility
via native X-Slot
Eaton 5125, 9125, 9170+, 9330, 9340, 9390
UPS compatibility
via expansion chassis
Eaton
Prestige 9
Eaton
5115
Eaton 9315 Hot Sync
parallel redundant module
Eaton Plus
12, 18, 36
Eaton
9120
Eaton 9315 Hot Sync
parallel capacity UPM;
Eaton 9315
reverse transfer module
Eaton
9170+
Eaton 9315 Hot Sync
parallel capacity SBM
Operating temperature 10° to 40°C
Operating humidity 20–80% relative humidity (noncondensing)
Power input 9 Vdc unregulated
Power consumption 1.5 Watts
Dimensions in inches (mm) 4.70 L x 4.50 W x 1.50 H (119.4 L x 114.3 W x 38.1 H)
Weight 7 oz
Regulatory FCC Class B
CA08104001E For more information, visit: www.eaton.com/consultants
33.4-11
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
Eaton Software and Connectivity
Serial Protocol Products
095
Expansion Chassis
Expansion Chassis
General Description
The expansion chassis is a three-slot
power quality peripheral device that
expands communication methods for
a UPS through its support for X-Slot
cards. It comes pre-configured with
a card that conforms to the Modicon,
Modbus protocol.
Application Focus
Single UPS module and parallel
systems (single/three-phase UPS)
Key Product Features
Creates wide array of communica-
tion options for UPSs
Primary focus on Eaton 9315 UPS
models to enable use of new
X-Slot communication cards
Acts as the framework for protocol
conversion via compatible X-Slot
cards to: Modbus; SNMP; HTTP
Built-in Modbus card provides
integration of UPS information into
building management systems
Compatible with X-Slot cards:
Modbus card (one included);
ConnectUPS-X SNMP/Web adapter;
ConnectUPS-M SNMP module;
single port serial card; multi-
server card
Flexible mounting options
Redundant power inputs
Integration
The expansion chassis and associated
cards effectively act as a protocol
converter easily integrating the Eaton
UPS into open architecture manage-
ment systems. This device may be
placed on or close to the associated
UPS system using the included
mounting feet. The kit includes
brackets for rack and wall mounting.
Two additional slots are available for
use with any of the following cards:
A ConnectUPS™-X SNMP/Web
adapter—monitor via SNMP or
the Web
A ConnectUPS-M SNMP module—
monitor via simple network
management protocol (SNMP)
A single port serial card—connect
an additional server for monitoring
and graceful shutdown
A multi-server card—connect up
to three servers for monitoring and
graceful shutdown, supports load
segment control and RS-232 signals
for low battery and AC fail
A Modbus card—connect to another
Modbus network, monitor via BMS
Figure 33.4-2. Typical Configuration
Table 33.4-7. Technical Data
Part
Number
05147063
Description Adds Modbus card plus two additional slots for X-Slot communication
cards to supported UPSs
Included card Modbus card
Optional cards ConnectUPS-Web/SNMP-X xHub card
ConnectUPS-M SNMP module
Single port serial card
Multi-server card
Additional Modbus card
Communication with UPS DB-9 via Included serial cable
UPS compatibility Eaton 5115; Eaton 5125; Eaton 9120; Eaton 9125; Eaton 9155; Eaton
9170+; Eaton Prestige 9; Eaton Plus 12, 18, 36; Eaton 9315 Reverse
Transfer Module; Eaton 9315 Hot Sync Parallel Redundant Module;
Eaton 9315 Hot Sync Parallel Capacity UPM; Eaton 9315 Hot Sync
Parallel Capacity SBM; Eaton 9320; Eaton 9335; Eaton 9390
Mounting Stand-alone (ft), rack (19 inches, 483 mm), or wall mount
Operating temperature 10° to 40°C
Operating humidity 20 to 80% relative humidity (noncondensing)
Power input Switchable 230/120 Vac, 50/60 Hz (via included transformer)
Power consumption 6 watts maximum
Dimensions in inches (mm) 18.00 x 1.75 x 6.00 (457.2 x 44.4 x 152.4)
Weight 6 lbs (including 1 lb for power supply)
Regulatory FCC Class B
33.4-12
For more information, visit: www.eaton.com/consultants CA08104001E
September 2011
Uninterruptible Power Systems
Sheet 33
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
096
This page intentionally left blank.