Data Sheet 70.2040 Page 6/10
Parameter and configuration
Operating level
Parameter level
Configuration level
Designation Display Factory setting Value range
Setpoint SP/SP1/SP2 0 SPL—SPH
Ramp setpoint SPr 0 SPL—SPH
Timer value/timer start value ti/ti0 00 —999.9h
Designation Display Factory setting Value range
Setpoint 1 SP 1 0 SPL—SPH
Setpoint 2 SP 2 0 SPL—SPH
Limit value for limit comparator AL 0 -1999 to +9999 digit
Proportional band 1 Pb:1 0 0 — 9999 digit
Proportional band 2 Pb:2 0 0 — 9999 digit
Derivative time dt 80sec 0 — 9999 sec
Re se t time rt 350sec 0 — 9999 sec
Cycle time 1 CY 1 20.0sec 1.0 — 999.9 sec
Cycle time 2 CY 2 20.0sec 1.0 — 999.9 sec
Contact spacing db 0 0 — 1000 digit
Differential (hysteresis) 1 HYS.1 1 0 — 9999 digit
Differential (hysteresis) 2 HYS.2 1 0 — 9999 digit
Wor k in g po in t Y:0 0% -100 to +100 %
Maximum output Y:1 100% 0 to 100 %
Minimum output Y:2 -100% -100 to +100 %
Filter time constant dF 0.6sec 0.0 — 100.0 sec
Ramp slope rASd 0 0 — 999 digit
Designation Display Factory setting Value range/selection
Transducer C111 Pt100 Pt100, Pt1000, KTY11-6, T, J, U, L, K, S,
R, B, N, 0 (4 )—20mA, 0 (2)—10V
Decimal place/unit C112 none/°C none, one, two/°C, F
Controller type/outputs C113 see table on next page
Limit comparator function C114 no function no function, lk1—8
Ramp function C115 no fu n c tio n no fu n c tio n , ° C /min, °C/h
Output signal on overrange/
underrange C116 0% output
limit comparator off 0%, 100%, -100%
limit comparator on/off
Logic input C117 n o fu n c tion k e y / le v e l in h ib it,
ramp stop, setpoint switching
Outputs 1, 2 and 3
(only Type 702042/43/44) C118 fun c tio n s a s d e fin e d
under C113 freely c o nfigur a b le
(see table on next page)
Timer function C120 no function see description “Timer function”
Start condition for timer C121 from k e y p a d /
log ic inp u t - pow e r ON
- keypad/logic input
- to le r a n c e limit
Timer s ignalling C122 no fun c tio n - timer sta rt to timer run -d o wn
- after ru n -d o w n fo r 1 0sec
- after ru n -d o w n fo r 1 min.
- after run-down until acknowledgement
U n it o f t ime (timer) C123 mm .ss - m m.ss
- hh.m m
- hhh.h
Start value of value range SCL 0 -1999 to +9999 digit
En d valu e of value ra n g e SCH 100 -1999 to +9999 digit
Lower setpoint limit SPL -200 -1999 to +9999 digit
U p p e r s epoint limit SPH 850 -1999 to +9999 digit
Process value correction OFFS 0 -1999 to +9999 digit
Differential (hysteresis) HySt 1 0— 9999 digit