Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Timers Relays & Sockets Signaling Lights TW Series -- 22mm NEMA Style Pushbuttons Key features: * * * * * * * * * * TW NEMA Style Switches with snap-on contacts Corrosion resistant octagonal chrome plated locking bezel Snap-on 10A contact blocks LED illumination Slow make, double break, contacts Modular construction for maximum flexibility Type 4X and IP65 watertight/oiltight panel Available assembled or as sub-components Finger-Safe - Spring-Up Large M3.5 screw terminals with captive sems plate Button styles include flush, extended, mushroom, or square and all bodies are crafted from fracture-resistant nylon. All illuminated units feature two lens styles, one that maximizes light dispersion, the other accommodates direct lens engraving. Contact mechanism allow for a wide current rating, 5mA to 10A, which reduces the need for various contact materials. When looking for a 22mm switch that is durable, easy to use, and versatile, then IDEC's TW series is your solution. CSA Approved File No. LR21451 File No. DK95-01696 Certificate No. 2030010305027380 Circuit Breakers Terminal Blocks Contactors UL Listed File No. E68961 IDEC has your 22mm switching needs covered. 696 www.IDEC.com 1904032203 Switches & Pilot Devices Switches & Pilot Devices Conforming to Standards o22mm - TW Series EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals File No. E68961 Certificate No. 2030010305027380 File No. LR21451 CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TUV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Operation: -25 to +50C (without freezing), Storage: -40 to +80C (without freezing) Vibration Resistance 5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6 Shock Resistance 1000m/sec2 (100g) conforming to IEC6068-2-7 Electric Shock Protection Class 2 conforming to IEC60664-7 Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110) IP65 from front of the panel; (IP54 for key switches) IP20 (Type HW-U contact block) Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches) Mechanical Life Momentary pushbuttons: 5,000,000 (1800 operations per hour) All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 Rated Operational Characteristics AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or slow make NO, self-cleaning Number of Wires Recommended Tightening Torque (Nm) Crimping Terminal 2 1.0 to 1.3 o0.5 to 1.6 mm (AWG14 to 22) 2 1.0 to 1.3 o1.7 to 2.0 mm (AWG12) 1 Recommended Terminal Torque 1.2 to 1.3 0.3 to 2.0 mm2 (AWG14 to 22) 2 1.0 to 1.3 2.1 to 3.5 mm2 (AWG12) 1 1.2 to 1.3 2 1.0 to 1.3 Solid Wire Stranded Wire Terminal Screw Timers Wire Unit HW-U Contact Block Relays & Sockets Specifications Operating Temperature Signaling Lights Registration No: J9551802 (E-Stops) Registration No: J9551803 (All other switches) Registration No: J9551804 (Pilot Lights) M3.5 Crimping Terminal Illuminated Unit (*1) Solid Wire o0.5 to 1.6 mm (AWG14 to 22) Stranded Wire 0.3 to 2.0 mm (AWG14 to 22) Crimping Terminal Applicable Wire Size Pilot Light Solid Wire o0.5 to 1.6 mm (AWG14 to 22) Stranded Wire o0.3 to 2.0 mm (AWG14 to 22) M3.5 0.6 to 1.0 (M3.0) 2 1.0 to 1.3 (M3.5) Contact Ratings 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50m or less Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB) Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Lamp Ratings LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max Horsepower Rating 1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor) Contact Material Silver Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Contact Block Type HW-U Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600) DC-13 (P600) Terminal Blocks External Short-Circuit Protection Contactors 1. * refers to the lamp terminals of the illuminated push buttons and selector switches. 1904032203 AC50/60Hz Operational Current DC 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads and solid state loads 10A -- 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A -- 7A 5A 3A 1A DC-12 Control of resistive loads and solid state loads 10A 5A -- 2.2A 1.1A -- DC-13 Control of electromagnets 5A 2A -- 1.1A 0.6A -- 800-262-IDEC (4332) * USA & Canada Circuit Breakers Characteristics Contact Ratings by Utilization Category Operational Voltage 697 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Timers Relays & Sockets Signaling Lights Non-Illuminated Pushbuttons (Assembled) Assembled Pushbuttons A B ( ) W 1 10 - B Function Button Color B: Momentary O: Maintained K: Key On/Off Lock B: Black R: Red G: Green S: Blue W: White Y: Yellow Bezel Shape Blank: Octagonal F: Full Shroud G: Mushroom Shroud Q: Square Contact Arrangement Contactors 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Button Shape 1: 2: 3: 4: Flush Extended Mushroom Head O 29mm Mushroom Head O 40mm Terminal Blocks Series Designation W: TW Series Circuit Breakers To be used for interpreting part numbers only, not for part number development. 698 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) continued Non-Illuminated Pushbuttons Style j Button Color Codes Contacts 1NO 1NC 1NO-1NC 2NO 2NC Flush Momentary Action Maintained Action Color Code AOW110-j AOW101-j AOW111-j AOW120-j AOW102-j Black B Green G Red R ABW110-j ABW101-j ABW111-j ABW120-j ABW102-j Extended with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFW210-j ABFW201-j ABFW211-j ABFW220-j ABFW202-j AOFW210-j AOFW201-j AOFW211-j AOFW220-j AOFW202-j O 29mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW310-j ABW301-j ABW311-j ABW320-j ABW302-j AOW310-j AOW301-j AOW311-j AOW320-j AOW302-j O 40mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW410-j ABW401-j ABW411-j ABW420-j ABW402-j AOW410-j AOW401-j AOW411-j AOW420-j AOW402-j O 40mm Mushroom Head with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGW410-j ABGW401-j ABGW411-j ABGW420-j ABGW402-j AOGW410-j AOGW401-j AOGW411-j AOGW420-j AOGW402-j Square Flush 1NO 1NC 1NO-1NC 2NO 2NC ABQW110-j ABQW101-j ABQW111-j ABQW120-j ABQW102-j AOQW110-j AOQW101-j AOQW111-j AOQW120-j AOQW102-j Square Extended 1NO 1NC 1NO-1NC 2NO 2NC ABQW210-j ABQW201-j ABQW211-j ABQW220-j ABQW202-j AOQW210-j AOQW201-j AOQW211-j AOQW220-j AOQW202-j Keylock Push On/ Off 1NO 1NC 1NO-1NC 2NO 2NC AKW210 AKW201 AKW211 AKW220 AKW202 - 1. 2. 3. 4. 5. 1904032203 Circuit Breakers AOFW110-j AOFW101-j AOFW111-j AOFW120-j AOFW102-j W Terminal Blocks ABFW110-j ABFW101-j ABFW111-j ABFW120-j ABFW102-j White Contactors Recessed 1NO 1NC 1NO-1NC 2NO 2NC Y Timers AOW210-j AOW201-j AOW211-j AOW220-j AOW202-j Relays & Sockets ABW210-j ABW201-j ABW211-j ABW220-j ABW202-j S Signaling Lights Extended 1NO 1NC 1NO-1NC 2NO 2NC Blue Yellow In place of j, specify the Button Color Code from table. For sub-assembled part numbers, see next page. For accessories, see page 728. For dimensions, see page 730. Keyed switches are supplied with two keys. All units are keyed alike. 800-262-IDEC (4332) * USA & Canada 699 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact Blocks + Operators Style Operator + Button Buttons Part Number Momentary Maintained = Complete Part Contact Blocks Style Part Number Style Round Flush Round Flush/Extended ABW1B-j Relays & Sockets ABW-100 Round with Full Shroud/Recessed AOFW-200 O 29mm Mushroom Timers O 40mm, O 29mm Mushroom Head AOW-300 O 40mm Mushroom O 40mm Mushroom Head with Full Shroud ABW4B-j Contactors HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Color Code Black B Green G Red R Blue S Yellow Y White W AOGW-400 Square Flush ABQW1B-j Square Flush/Extended ABQW-100 Terminal Blocks FingerSafe Spring-Up Terminal j Button Color Codes ABW3B-j ABGW-400 1NC Dummy Block ABW2B-j ABW-300 1NO AOW-100 Round Extended ABFW-200 Contacts AOQW-100 Square Extended ABQW2B-j Keylock Push On/Off -- AKW-200 Circuit Breakers In place of j specify the button color code from table 700 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Stop Switches (Assembled) Signaling Lights To be used for interpreting part numbers only, not for part number development. Relays & Sockets Assembled Stop Switches A V (L) W 4 (B) (99) Function 11 (D) - R - (24V) Lamp Voltage (full voltage illuminated units only) 6V: 12V: 24V: 120V: 240V: Illumination Blank: None L: Illuminated 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC Timers V: Pushlock Turn Reset Y: Push-Pull X: Pushlock Key Reset Button/Lens Color W: TW Series W: White Y: Yellow Contactors A: Amber R: Red G: Green S: Blue B: Black Series Designation Button/Lens Size 3: 29mm Mushroom 4: 40mm Mushroom Lamp Type (illuminated units only) (illuminated units only) Blank: Standard (ribbed) B: Engravable (smooth with insert) D: LED Illuminated Circuit 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC Contact Arrangement (illuminated unit only) 1904032203 Full Voltage (LED determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer 800-262-IDEC (4332) * USA & Canada Circuit Breakers 99: 126: 246: 486: Terminal Blocks Lens Type 701 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Stop Switches (Assembled), continued Non-Illuminated Stop Switches Style O 29mm Pushlock Turn Reset* Relays & Sockets O 40mm Push-Pull Timers Contacts Part Number Color Code AVW410-R* AVW401-R* AVW411-R* AVW420-R* AVW402-R* Black B Green G Red R 1NO 1NC 1NO-1NC 2NO 2NC O 40mm Pushlock Turn Reset* 1NO 1NC 1NO-1NC 2NO 2NC AVW310-R* AVW301-R* AVW311-R* AVW320-R* AVW302-R* 1NO 1NC 1NO-1NC 2NO 2NC AYW410-j AYW401-j AYW411-j AYW420-j AYW402-j 1NO 1NC 1NO-1NC 2NO 2NC O 40mm Pushlock Key Reset * 1. 2. 3. 4. 5. j Button Color Codes Contactors Contacts Part Number Transformer AVLW4 m 11D-R* AVLW4 m 20D-R* AVLW4 m 02D-R* Full Voltage 1NO-1NC 2NO 2NC AVLW49911D-R*-l AVLW49920D-R*-l AVLW49902D-R*-l Transformer 1NO-1NC 2NO 2NC AVLW3m11D-R* AVLW3m20D-R* AVLW3m02D-R* Full Voltage 1NO-1NC 2NO 2NC AVLW39911D-R*-l AVLW39920D-R*-l AVLW39902D-R*-l Transformer 1NO-1NC 2NO 2NC AYLW4 m 11D-k AYLW4 m 20D-k AYLW4 m 02D-k Full Voltage 1NO-1NC 2NO 2NC AYLW49911D-k-l AYLW49920D-k-l AYLW49902D-k-l O 29mm Pushlock Turn Reset O 40mm Push-Pull Yellow Y Color Code Amber A Green G Red R Blue S White W l Full Voltage Codes 1NO-1NC 2NO 2NC O 40mm Pushlock Turn Reset Type Terminal Blocks R* R* R* R* R* Illuminated Stop Switches Type S W k LED/Lens Color Codes *Available in Red only. In place of j, specify the Button Color Code from table. For sub-assembled part numbers, see next page. For accessories, see page 728. For dimensions, see page 730. Style Circuit Breakers AXW410AXW401AXW411AXW420AXW402- Blue White Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V m Transformer Voltage Codes Voltage Code 120VAC 240VAC 480VAC 126 246 486 Transformers step down to 6V. 1. *Available in red only. 2. In place of k, specify the Lens Color Code (see table above). 3. In place of l, specify the Full Voltage Code (lamp voltage) (see table above). 4. In place of m, specify the Transformer Voltage Code (see table above). 5. For sub-assembly part numbers, see next page. 6. For accessories, see page 728. 7. For dimensions, see page 730. 702 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Stop Switches (Sub-Assembled) Transformer/ Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Button or Lens = Complete Part Signaling Lights *Not applicable for full voltage units Operators Style Buttons Lamps Part Number Style Non-Illuminated Illuminated O 40mm Pushlock Turn Reset Part Number Style LED O 29/O 40mm Pushlock Turn Reset AVW4B-R* AVLW3-0600 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. O 29mm Pushlock Turn Reset O 40mm Push-Pull Part Number Relays & Sockets AVW-300 Voltage AVW3B-R* AYW-400 AYLW4-0600 j Button Color Codes Color O 40mm Push-Pull AYW4B-j AXW-300 -- O 40mm Pushlock Key Reset AXW4B-R* B G Red R Blue S White W Yellow Y k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Contactors 1. *Available in Red only 2. In place of j, specify the button color code from table. Black Green Timers O 40mm Pushlock Key Reset Code Terminal Blocks Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 703 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Illuminated Stop Switches (Sub-Assembled) continued Lenses Transformers/Full Voltage Modules Style Part Number Style Standard Engravable AVLW3LU-R* AVLW3BLU-R* Full Size Transformer O 29mm Head Pushlock Turn Reset Finger-Safe O 40mm Head Pushlock Turn Reset AVLW4LU-R* AVLW4BLU-R* Relays & Sockets O 40mm Head Push Pull AYLW4LU-k Long Lamp Holder Used with Full-size Transformer and two contact blocks Used with TW-LH2 holder when using four contact blocks and transformer TW-F126B 240V AC TW-F246B 480V AC TW-F486B Finger-Safe HW-DA1FBN Full Voltage Adaptor For use with even number of contacts. Finger-Safe TW-DA1FB All Transformers step down to 6V (use 6V LED). Contact Blocks Style Part Number Contacts 1NO 1NC FingerSafe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Dummy Block HW-DB TW-LH2 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function HW-LH3 Circuit Breakers Terminal Blocks Contactors Lead Holder Application 120V AC For use with odd number of contacts. AYLW4BLU-k 1. In place of k, specify the lens color code from table on previous page. 2. *Available only in red 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Style Part Number Dummy Block with Full Voltage Adaptor Lamp Circuit Components Timers Description 704 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Pilot Lights (Assembled) Signaling Lights Relays & Sockets Assembled Pilot Lights A P (Q) W 1 (B) (99) Function (D) - R - (24V) Lamp Voltage Blank: Octagonal (round lenses) Q: Square 6V: 12V: 24V: 120V: 240V: Series Designation Lens Color Code Bezel Shape W: TW Series Timers (Full Voltage Units Only) P: Pilot Light 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC Lens Shape 1: Flat 2: Dome Lens Type Contactors A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lamp Blank: Standard (ribbed) B: Engravable (smooth with insert included) Terminal Blocks D: LED Illumination Circuit 99: 126: 246: 486: Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer 1904032203 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V. 705 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Pilot Lights (Assembled) continued Assembled Pilot Lights k Lens Color Codes Style Type Voltage Part Number Transformer 120VAC 240VAC 480VAC APW1126D-k APW1246D-k APW1486D-k Round Flat -- APW199D-k-l Code A Green G Red R Blue S White W Yellow Y Transformer 120VAC 240VAC 480VAC APW2126D-k APW2246D-k APW2486D-k Full Voltage -- APW299D-k-l 120VAC 240VAC 480VAC APQW1B126D-k APQW1B246D-k APQW1B486D-k 6V AC/DC 6V Transformer 12V AC/DC 12V 24V AC/DC 24V APQW1B99D-k-l 120V AC 120V 240V AC 240V Dome l Full Voltage Codes Square Flat Full Voltage 1. 2. 3. 4. 5. 6. -- Voltage Code In place of k, specify the Lens Color Code from table below. In place of l, specify the Full Voltage Code from table below. For accessories, see page 728. For dimensions, see page 730. For sub-assembly part numbers, see next page. Yellow pilot light comes with white LED. Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Full Voltage Color Amber 706 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Pilot Lights (Sub-Assembled) Transformer + Operator + Lamp + Lens = Complete Part Signaling Lights * Transformer not required for full voltage units. Operators Style Lamps Part Number k LED/Lens Color Codes Style Round Dome/Flat LED Part Number 6V AC/DC LSTD-6k 12V AC/DC Color Code Amber A LSTD-1k Green G 24V AC/DC LSTD-2k Red R 120V AC LSTD-H2k Blue S 240V AC LSTD-M4k White W Yellow Y 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. 3. Yellow LED not available. Use white LED. Square UPQW-199 Description Finger-Safe Lenses Part Number Engravable Dome Part Number 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Timers Same operator is used for full voltage as for transformer completed units. Standard If clear lens is desired, use white marking lens and remove engraving insert Transformers Style Style Relays & Sockets APW-199 Voltage All Transformers step down to 6V (use 6V LED). Contactors APW2LU-k -- APW1LU-k APW1BLU-k -- APQW1BLU-k Round Flat Terminal Blocks Square Flat 1904032203 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. In place of k, specify the Lens Color Code from table. 2. Standard lenses have a ribbed lens to enhance light dispersion. Marking lenses are smooth and include an engravable insert. 707 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Relays & Sockets Signaling Lights Illuminated Pushbuttons (Assembled) Assembled Illuminated Pushbuttons A L (F) W 2 (B) 99 11 Function Lamp Voltage (Full Voltage Units Only) Timers L:Momentary Action OL:Maintained Action 6V: 12V: 24V: 120V: 240V: Bezel Shape Blank: Octagonal (round lenses) F: Full Shroud (round lenses) Q: Square A: Amber G: Green R: Red S: Blue W: White Y: Yellow Contactors W: TW series Lens Shape/Size 2: Standard Extended (round or square) 3: 29mm Mushroom 4: 40mm Mushroom Lamp Type D: LED Lamp Terminal Blocks Lens Type Circuit Breakers 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC Lens Code Series Designation Contact Arrangement Blank: Standard (ribbed) B: Engravable (smooth with insert) 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Illumination Circuit 99: 126: 246: 486: (D) - R - (24V) Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Transformers step down to 6V. 708 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Pushbuttons (Assembled) Illuminated Pushbuttons k LED/Lens Color Codes Style Contacts Extended Lens Transformer AOLW2 m 11D-k AOLW2 m 20D-k AOLW2 m 02D-k ALW29911D-k-l ALW29920D-k-l ALW29902D-k-l AOLW29911D-k-l AOLW29920D-k-l AOLW29902D-k-l Transformer 1NO-1NC 2NO 2NC ALFW2 m 11D-k ALFW2 m 20D-k ALFW2 m 02D-k AOLFW2 m 11D-k AOLFW2 m 20D-k AOLFW2 m 02D-k Transformer ALFW29911D-k-l ALFW29920D-k-l ALFW29902D-k-l AOLFW29911D-k-l AOLFW29920D-k-l AOLFW29902D-k-l 1NO-1NC 2NO 2NC ALW3 m 11D-k ALW3 m 20D-k ALW3 m 02D-k AOLW3 m11D-k AOLW3 m20D-k AOLW3 m 02D-k 1NO-1NC 2NO 2NC ALW39911D-k-l ALW39920D-k-l ALW39902D-k-l AOLW39911D-k-l AOLW39920D-k-l AOLW39902D-k-l Code Amber A Green G Red R Blue S White W Yellow Y 1. Mushroom lenses not available in yellow. 2. Yellow pushbutton comes with white LED. l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V m Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 Timers Full Voltage 1NO-1NC 2NO 2NC Color Relays & Sockets 1NO-1NC 2NO 2NC o29mm Mushroom Button Transformers step down to 6V (use 6V LED). o40mm Mushroom Button ALW4 m 11D-k ALW4 m 20D-k ALW4 m 02D-k AOLW4 m11D-k AOLW4 m20D-k AOLW4 m 02D-k Full Voltage 1NO-1NC 2NO 2NC ALW49911D-k-l ALW49920D-k-l ALW49902D-k-l AOLW49911D-k-l AOLW49920D-k-l AOLW49902D-k-l Transformer 1NO-1NC 2NO 2NC ALQW2B m11D-k ALQW2B m20D-k ALQW2B m02D-k AOLQW2B m11D-k AOLQW2B m20D-k AOLQW2B m02D-k Full Voltage 1NO-1NC 2NO 2NC ALQW2B9911D-k-l ALQW2B9920D-k-l ALQW2B9902D-k-l AOLQW2B9911D-k-l AOLQW2B9920D-k-l AOLQW2B9902D-k-l Terminal Blocks 1NO-1NC 2NO 2NC Contactors Transformer Square Extended In place of k, specify the Lens Color Code (see table). Mushroom lenses not available in yellow. In place of l, specify the Full Voltage Code (lamp voltage) (see table). In place of m, specify the Transformer Voltage Code (see table). For sub-assembly part numbers, see next page. For accessories, see page 728. For dimensions, see page 730. Light is independent of switch position. Yellow pushbutton comes with white LED. 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1904032203 ALW2 m 11D-k ALW2 m 20D-k ALW2 m 02D-k Maintained Full Voltage Full Voltage 1. 2. 3. 4. 5. 6. 7. 8. Momentary Signaling Lights Extended Lens with Full Shroud 1NO-1NC 2NO 2NC Part Number 709 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Illuminated Pushbuttons (Sub-Assembled) Transformer/ Adaptor* + + Lamp Holder + Operator + Lamp + Operators = Complete Part Lamps Style Part Number Momentary Style Maintained LED ALW-0600 Extended with Full Shroud AOLW-0600 ALFW-0600 Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. AOLFW-0600 Lamp Circuit Components Style o29mm/o40mm Mushroom Timers Lens *Not applicable for full voltage units Extended Relays & Sockets Contacts ALW3-0600 Application Long Lamp Holder AOLW3-0600 Used with Full-size Transformer and two contact blocks Square/Extended ALQW-2B0600 Part Number TW-LH2 AOLQW-2B0600 Lead Holder Used with TW-LH2 holder when using four contact blocks and transformer Lenses Contactors Style Round Extended Circuit Breakers Terminal Blocks o 29mm Mushroom Head* Part Number Standard Engravable ALW2LU-k ALW2BLU-k ALW3LU-k ALW3BLU-k HW-LH3 k LED/Lens Color Codes Color Code Color Code Amber A Blue S Green G White W Red R Yellow Y Yellow LED not available. Use white LED. o 40mm Mushroom Head* ALW4LU-k ALW4BLU-k Square Extended -- ALQW2BLU-k 1. In place of k, specify the lens color code from table on the bottom right. 2. *Mushroom lens not available in yellow. 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. 710 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Pushbuttons (Sub-Assembled) continued Contact Blocks Style Transformers/Full Voltage Modules Contacts 1NO 1NC FingerSafe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Description Full Size Transformer Finger-Safe HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Part Number 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Dummy Block with Full Voltage Adaptor For use with odd number of contacts. Finger-Safe HW-DA1FBN Full Voltage Adaptor For use with even number of contacts. Finger-Safe TW-DA1FB Signaling Lights Dummy Block Style Relays & Sockets All Transformers step down to 6V (use 6V LED). Timers Contactors Terminal Blocks Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 711 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Timers Relays & Sockets Signaling Lights Non-Illuminated Selector Switches (Assembled) Assembled Selector Switches A S W 3 (1) (L) 20 - 304 Function Circuit Number S: Selector Switch (Standard circuits shown on following pages and 720.) Series Designation Contact Arrangement Code W: TW Series 10: 20: 40: 11: Number of Positions 2-Position 3-Position 4-Position 5-Position Operator Style Code Blank: Knob Operator L: Lever Operator K: Key Operator Spring Return Action Blank: Maintained 1: Spring return from Right (2 or 3 position) 2: Spring return from Left (2 or 3 position) 3: 2-Way spring return from Left and Right (3 position only) 1. 2. 3. 4. 1NC 2NC 4NC 2NO-2NC Use only when interpreting part numbers. Do not use for developing part numbers. Custom contact configurations available. Custom key removable codes available. Portions of part number inside ( ) are optional. Circuit Breakers Terminal Blocks Contactors 2: 3: 4: 5: 1NO 01: 2NO 02: 4NO 04: 1NO-1NC 22: 712 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) continued 2-Position Selector Switches Style Part Number Operator Position Spring Return from Left Mounting Spring Return from Right Contact Maintained 1NO 1 2 O O X O Knob Lever Key ASW210 ASW2L10 ASW2K10 ASW2110 ASW21L10 ASW21K10 ASW2210 ASW22L10 ASW22K10 1NC 1 2 X O O O Knob Lever Key ASW201-116 ASW2L01-116 ASW2K01-116 ASW2101-116 ASW21L01-116 ASW21K01-116 ASW2201-116 ASW22L01-116 ASW22K01-116 1NO 1NC 1 2 X O O X Knob Lever Key ASW211 ASW2L11 ASW2K11 ASW2111 ASW21L11 ASW21K11 ASW2211 ASW22L11 ASW22K11 2NO 1 2 O O X X Knob Lever Key ASW220 ASW2L20 ASW2K20 ASW2120 ASW21L20 ASW21K20 ASW2220 ASW22L20 ASW22K20 2NC 1 2 X X O O Knob Lever Key ASW202-104 ASW2L02-104 ASW2K02-104 ASW2102-104 ASW21L02-104 ASW21K02-104 ASW2202-104 ASW22L02-104 ASW22K02-104 2NO 2NC 1 2 3 4 O X O X X O X O Knob Lever Key ASW222 ASW2L22 ASW2K22 ASW2122 ASW21L22 ASW21K22 ASW2222 ASW22L22 ASW22K22 2NO 2NC 1 2 3 4 O O X X X X O O Knob Lever Key ASW222-111 ASW2L22-111 ASW2K22-111 ASW2122-111 ASW21L22-111 ASW21K22-111 ASW2222-111 ASW22L22-111 ASW22K22-111 L R L R L L R R Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 713 Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) continued 3-Position Selector Switches Style Part Number Spring Return from Left Spring Return Two-Way 2NO 1 2 X O O O O X Knob Lever Key ASW320 ASW3L20 ASW3K20 ASW3120 ASW31L20 ASW31K20 ASW3220 ASW32L20 ASW32K20 ASW3320 ASW33L20 ASW33K20 2NC 1 2 O X X X X O Knob Lever Key ASW302 ASW3L02 ASW3K02 ASW3102 ASW31L02 ASW31K02 ASW3202 ASW32L02 ASW32K02 ASW3302 ASW33L02 ASW33K02 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Knob Lever Key ASW322 ASW3L22 ASW3K22 ASW3122 ASW31L22 ASW31K22 ASW3222 ASW32L22 ASW32K22 ASW3322 ASW33L22 ASW33K22 2NO 2NC 1 2 3 4 X X O O O X X O X O O X Knob Lever Key ASW322-309 ASW3L22-309 ASW3K22-309 ASW3122-309 ASW31L22-309 ASW31K22-309 ASW3222-309 ASW32L22-309 ASW32K22-309 ASW3322-309 ASW33L22-309 ASW33K22-309 2NO 2NC 1 2 3 4 O O O O X O X O O X O X Knob Lever Key ASW322-310 ASW3L22-310 ASW3K22-310 ASW3122-310 ASW31L22-310 ASW31K22-310 ASW3222-310 ASW32L22-310 ASW32K22-310 ASW3322-310 ASW33L22-310 ASW33K22-310 4NO 1 2 3 4 X O X O O O O O O X O X Knob Lever Key ASW340 ASW3L40 ASW3K40 ASW3140 ASW31L40 ASW31K40 ASW3240 ASW32L40 ASW32K40 ASW3340 ASW33L40 ASW33K40 4NC 1 2 3 4 O X O X X X X X X O X O Knob Lever Key ASW304 ASW3L04 ASW3K04 ASW3104 ASW31L04 ASW31K04 ASW3204 ASW32L04 ASW32K04 ASW3304 ASW33L04 ASW33K04 L C R L C L R C C L R L R C R 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Every key selector switch uses an identical key. The key is removable in any maintained position. 4. Custom contact configurations are available, see page 720. 4-Position Selector Switch 5-Position Selector Switch 1 2 3 4 X O O O 2 3 Part Number 4 1 2 3 1 2NO 2NC 1 2 3 4 X O O O 4 O X O O O O X O O O O X Knob Lever ASW422-411 ASW4L22-411 Maintained Operator Position Mounting 1 Style 2 3 O X O O O O O O Part Number 4 5 O O X O O O O X 1 Knob Lever 2 3 4 5 ASW522-501 ASW5L22-501 Circuit Breakers 2NO 2NC Maintained Operator Position Mounting Contact Style Terminal Blocks Spring Return from Right Mounting Maintained Contact Operator Position Contact Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - TW Series 714 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + Operator + Knob or Lever* + Color Insert* = Complete Part Operators Handles and Inserts Style Positions Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 ASW300-1 ASW300-2 ASW300-3 Spring return from right, Cam 1 Spring return from right, Cam 2 ASW3100-1 ASW3100-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASW3200-1 ASW3200-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASW3300-1 ASW3300-2 4 Maintained, Standard Cam Maintained, Cam 1 ASW400 ASW400-1 5 Maintained, Standard cam Maintained, Cam 1 ASW500 ASW500-1 Maintained ASW2K00 Spring return from right ASW21K00 Spring return from left ASW22K00 Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 ASW3K00-1 ASW3K00-2 ASW3K00-3 Spring return from right, Cam 1 Spring return from right, Cam 2 ASW31K00-1 ASW31K00-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASW32K00-1 ASW32K00-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASW33K00-1 ASW33K00-2 3 2 3 j Handle/Insert Color Codes Color Code Black* B S G Red R Yellow Y White W Key Switch Black Sleeve AKW2B-B Lever ASWHHL-j Color Insert TW-HC1-j Contact Blocks Style Contacts FingerSafe Spring-Up Terminal Dummy Block 1NO 1NC HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) HW-DB 1. Push rod color code: Green = NO contact block Red = NC contact block. 2. Dummy blocks (no contacts) are used with an odd number of contact blocks. Circuit Breakers Blue Green Replacement Parts ASWHHY-j Terminal Blocks Two keys are supplied with every key switch, all are keyed alike, and removable from any maintained position. Locking rings are included with all operators. Order knobs, levers, and color inserts separately. Different cams produce different contact actions. For details, see page 720. Key switch operator supplied with black sleeve. Knob Contactors ASW2200 Part Number Timers ASW2100 Spring return from left Style Relays & Sockets ASW200 Spring return from right Knob/Lever 1. 2. 3. 4. Part Number Maintained 2 Key Description *Color inserts not available in black. Knob and lever not available in white. 1904032203 Signaling Lights 1. *Not needed with key type switches. 2. Knob type shown. 800-262-IDEC (4332) * USA & Canada 715 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Relays & Sockets Signaling Lights Illuminated Selector Switches (Assembled) Assembled Illuminated Selector Switches A SL W 2 (2) 99 11 (D) - (103) - R - (24V) Function Lamp Voltage (Full Voltage Units Only) SL:Illuminated Selector Switch 6V: 12V: 24V: 120V: 240V: Series Designation Timers W: TW series Number of Positions Lens Color Code 2: 2-Position 3: 3-Position A: Amber G: Green R: Red S: Blue W: White Y: Yellow Contactors Spring Return Action Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: Two-Way spring return from Left and Right Contact Circuit Number Illumination Circuit Standard circuits are listed on the following pages and 720. Full Voltage (lamp determines voltage) 120V AC Step Down Transformer 240V AC Step Down Transformer 480V AC Step Down Transformer Lamp Type D: LED Lamp Circuit Breakers Terminal Blocks 99: 126: 246: 486: 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC Contact Arrangement 10: 1NO 20: 2NO 40: 4NO 11: 1NO-1NC 01: 1NC 02: 2NC 04: 4NC 22: 2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V (use 6V lamp). 716 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Illuminated 2-Position Selector Switches j Transformer Voltage Codes Style Part Number Spring Return from Right Spring Return from Left Mounting Maintained Contact Operator Position 1NO 1NC 1 2 O X X O Transformer Full Voltage ASLW2 j 11D-k ASLW29911D-k-l ASLW21 j 11D-k ASLW219911D-k-l ASLW22 j 11D-k ASLW229911D-k-l 2NO 1 2 O O X X Transformer Full Voltage ASLW2 j 20D-k ASLW29920D-k-l ASLW21 j 20D-k ASLW219920D-k-l ASLW22 j 20D-k ASLW229920D-k-l 2NC 1 2 X X O O Transformer Full Voltage ASLW2 j 02D-104-k ASLW29902D-104-k-l ASLW21 j 02D-104-k ASLW219902D-104-k-l ASLW22 j 02D-104-k ASLW229902D-104-k-l ASLW2 j 22D-k ASLW29922D-k-l ASLW21 j 22D-k ASLW219922D-k-l ASLW22 j 22D-k ASLW229922D-k-l 2NO 2NC R O X O X X O X O Transformer Full Voltage L L R L R R 126 240VAC 246 480VAC 486 k LED/Lens Color Codes Color Code Amber A Green G Red R S W Yellow Y Relays & Sockets Blue White Part Number Spring Return From Right Spring Return from Left Spring Return Two-Way Mounting Maintained Contact Operator Position 2NO 1 2 X O O O O X Transformer Full Voltage ASLW3 j 20D-k ASLW39920D-k-l ASLW31 j 20D-k ASLW319920D-k-l ASLW32 j 20D-k ASLW329920D-k-l ASLW33 j 20D-k ASLW339920D-k-l 2NC 1 2 O X X X X O Transformer Full Voltage ASLW3 j 02D-k ASLW39902D-k-l ASLW31 j 02D-k ASLW319902D-k-l ASLW32 j 02D-k ASLW329902D-k-l ASLW33 j 02D-k ASLW339902D-k-l 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Transformer Full Voltage ASLW3 j 22D-k ASLW39922D-k-l ASLW31 j 22D-k ASLW319922D-k-l ASLW32 j 22D-k ASLW329922D-k-l ASLW33 j 22D-k ASLW339922D-k-l 2NO 2NC 1 2 3 4 X X O O O X X O X O O X Transformer Full Voltage ASLW3 j 22D-309-k ASLW39922D-309-k-l ASLW31 j 22D-309-k ASLW319922D-309-k-l ASLW32 j 22D-309-k ASLW329922D-309-k-l ASLW33 j 22D-309-k ASLW339922D-309-k-l 2NO 2NC 1 2 3 4 O O O O X O X O O X O X Transformer Full Voltage ASLW3 j 22D-310-k ASLW39922D-310-k-l ASLW31 j 22D-310-k ASLW319922D-310-k-l ASLW32 j 22D-310- k ASLW329922D-310- k -l ASLW33 j 22D-310-k ASLW339922D-310-k-l 4NO 1 2 3 4 X O X O O O O O O X O X Transformer Full Voltage ASLW3 j 40D-k ASLW39940D-k-l ASLW31 j 40D-k ASLW319940D-k-l ASLW32 j 40D-k ASLW329940D-k-l ASLW33 j 40D-k ASLW339940D-k-l 4NC 1 2 3 4 O X O X X X X X X O X O Transformer Full Voltage ASLW3 j 04D-k ASLW39904D-k-l ASLW31 j 04D-k ASLW319904D-k-l ASLW32 j 04D-k ASLW329904D-k-l ASLW33 j 04D-k ASLW339904D-k-l L C R Lamp Circuit Type C R L C L R C R L C R Contactors Terminal Blocks l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V 800-262-IDEC (4332) * USA & Canada Circuit Breakers In place of j, specify the Transformer Voltage Code. In place of k, specify the Lens/LED Color Code. In place of l, specify the Full Voltage Code. For custom contact configurations, see page 720. Light is independent of switch position. Yellow selector switch comes with white LED. L Timers 1. 2. 3. 4. 5. 6. 1904032203 120VAC Transformers step down to 6V (use 6V LED). Illuminated 3-Position Selector Switches, Maintained and Spring Return from Right Style Code Signaling Lights 1 2 3 4 L Lamp Circuit Type Voltage Switches & Pilot Devices Illuminated Selector Switches(Assembled) continued 717 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp/Lead Holder + Relays & Sockets Style Lens = Complete Part Lamps Positions Description Part Number Maintained 2 ASLW200 Spring return from right ASLW2100 Spring return from left ASLW2200 Timers 3 ASLW300-2 ASLW300-3 Spring return from right, cam 1 Spring return from right, cam 2 ASLW3100-1 Spring return from left, cam 1 Spring return from left, cam 2 ASLW3200-1 Spring return from left/right, cam 1 Spring return from left/right, cam 2 ASLW3300-1 ASLW3100-2 ASLW3200-2 ASLW3300-2 Different cams produce different contact action. For details, see Contact Arrangements on page 720. Lenses (Knobs) Style Knob Style LED ASLW300-1 Maintained, cam 1 Maintained, cam 2 Maintained, cam 3 Contactors + *Full voltage units use a full voltage adaptor TW-DA1FB (even number of blocks) OR HW-DA1FBN (odd number of blocks) instead of a transformer. Lamp holder is not included with operators, order separately. Operators Part Number Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y Yellow LED not available. Use white LED ASLWLU-k In place of k, specify the lens color code from table. Circuit Breakers Terminal Blocks LED 718 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Illuminated Selector Switches (Sub-Assembled) continued Contact Blocks Style Transformers/Full Voltage Modules Contacts 1NO 1NC FingerSafe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Full Size Transformer Finger-Safe HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Lamp Circuit Components Style Description Application Part Number 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Dummy Block with Full Voltage Adaptor For use with odd number of contacts. Finger-Safe HW-DA1FBN Full Voltage Adaptor For use with even number of contacts. Finger-Safe TW-DA1FB Relays & Sockets Short Lamp Holder Part Number Signaling Lights Dummy Block Style All Transformers step down to 6V (use 6V lamp). Used with full voltage adaptor and one contact block TW-LH1 Used with Full-size Transformer and two contact blocks TW-LH2 Used with TW-LH2 holder when using four contact blocks and full size transformer HW-LH3 Long Lamp Holder Timers Lead Holder Contactors Terminal Blocks Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 719 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Contact Arrangement Charts How to Read Contact Arrangement Charts Contact Arrangement Circuit Number Type and quantity of switch contacts * N/D = No designation required Relays & Sockets Contact Circuit Number 1NO N/D 1NC 116 Timers N/D 1NO 1NC 103 600 Terminal Blocks Contactors 1NO-EM 1NC-LB 601 2NO N/D 2NC 104 N/D 2NO 2NC 111 Mounting Position 2 1 Contact Block Mounting Position Operator Position Position or mounting contact blocks on operator. Contact Block Part Number Truth table indicates the operating position of contact block when operator is switched to that position (X - closed, O - open). Part number to use when ordering sub-assembly contact blocks, as required for use with corresponding mounting position Contact Arrangement Chart: 2-Position Selector Switches Operator Position 4 3 To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Style Circuit Breakers R L Operator Part Number Contact Block Part Number L R 1 O X HW-U10-F 2 O O HW-DB 1 X O HW-U01-F 2 O O HW-DB 1 O X HW-U10-F 2 X O HW-U01-F 1 X O HW-U01-F 2 O X HW-U10-F 1 O X HW-U10R-F 2 X O HW-U01R-F 1 X O HW-U01R-F 2 O X HW-U10R-F 1 O X HW-U10-F 2 O X HW-U10-F 1 X O HW-U01-F 2 X O HW-U01-F 1 O X HW-U10-F 2 X O HW-U01-F 3 O X HW-U10-F 4 X O HW-U01-F 1 O X HW-U10-F 2 O X HW-U10-F 3 X O HW-U01-F 4 X O HW-U01-F Description Maintained L R Spring Ret. from Rt. L R Spring Ret. from Lt. L Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 R 1. NO-EM, NC-LB = Early Make, Late Break. N/D = No circuit number designation required in assembled selector switch part number. 2. X = On (closed contacts) O = Off (Open contacts) 720 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Contact Arrangement Chart: 3-Position Selector Switches Style Operator Part Number Operator Position Contact Circuit Number 202 1NO 1NC 302 303 2NO 301 304 N/D N/D 2NO 2NC 308 310 0 0 HW-U10-F 2 X X O HW-U01-F 1 0 X X HW-U01-F 2 O 0 X HW-U10-F 1 X 0 X HW-U10-F 2 X X O HW-U01-F 1 0 X O HW-U01-F 2 O 0 X HW-U10-F 1 X 0 0 HW-U10-F 2 O 0 X HW-U10-F 1 X 0 X HW-U10-F 2 O 0 X HW-U10-F 1 0 X O HW-U01-F 2 X X O HW-U01-F 1 0 X X HW-U01-F 2 X X O HW-U01-F 1 X 0 0 HW-U10-F 2 0 0 X HW-U10-F 3 0 X X HW-U01-F 4 X X 0 HW-U01-F 1 0 X X HW-U01-F 2 0 0 X HW-U10-F 3 0 X X HW-U01-F 4 0 0 X HW-U10-F 1 X 0 X HW-U10-F 2 X X 0 HW-U01-F 3 X 0 X HW-U10-F 4 X X O HW-U01-F 1 X 0 X HW-U10-F 2 X X 0 HW-U01-F 3 0 X O HW-U01-F 4 O 0 X HW-U10-F 1 0 X O HW-U01-F 2 O 0 X HW-U10-F 3 0 X O HW-U01-F 4 0 0 X HW-U10-F C R L C R L C R L C R Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 1. Each operator sub-assembly is available as a "-1" and a "-2" for 3-position selector switches. The internal cam of a "-1" is different from that of a "-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X-X Overlapping contacts remain on (closed) when switch is moved between these two positions. 1904032203 800-262-IDEC (4332) * USA & Canada 721 Circuit Breakers X L Terminal Blocks 309 1 R Two-Way Contactors 210 C Spring Return from Left Timers 2NC L Description Maintained Relays & Sockets N/D Contact Block Part Number Signaling Lights 203 Mounting Position Spring Return from Right Switches & Pilot Devices Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - TW Series Contact Arrangement Chart: 3-Position Selector Switches Style Circuit Number Contact N/D 4NO 305 N/D 4NC 314 Mounting Position Contact Block Part Number L C 1 X 0 0 HW-U10-F 2 0 0 X HW-U10-F 3 X 0 0 HW-U10-F 4 0 0 X HW-U10-F 1 X 0 X HW-U10-F 2 0 0 X HW-U10-F 3 X 0 X HW-U10-F 4 0 0 X HW-U10-F 1 0 X X HW-U01-F 2 X X 0 HW-U01-F 3 0 X X HW-U01-F 4 X X O HW-U01-F 1 0 X O HW-U01-F 2 X X 0 HW-U01-F 3 0 X O HW-U01-F 4 X X 0 HW-U01-F R Description Maintained L C R Spring Return from Right L C R Spring Return from Left L C R Two-Way L C R Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-2 1. Each operator sub-assembly is available as a "-1" and a "-2" for 3-position selector switches. The internal cam of a "-1" is different from that of a "-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X-X Overlapping contacts remain on (closed) when switch is moved between these two positions. Circuit Breakers Terminal Blocks Contactors Timers Operator Part Number Operator Position 722 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Custom Selector Switch Building Guide Mounting Positions R 4 L To build a custom selector switch, follow these steps. Step 1 2 How many positions of the switch are needed? 3 # of positions (2, 3, 4, 5) Signaling Lights 1 Step 2 How many contacts should there be? # of isolated contacts (maximum 6) Step 3 Relays & Sockets Fill in the Truth Table (X = closed, 0 = open) Knob Position 1 2 3 4 5 1 Contacts 2 3 Timers 4 5 6 Step 4 If building a 2 position selector, skip this step. (2 position selectors have only one cam) Contactors If building a 3, 4, or 5 position selector, determine appropriate cam as follows: * Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page). * Repeat for all rows. The user must find one operator that contains all rows from above table. * Record the operator cam version. Step 5 Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. "L" and "R" refer to mounting on left or right side of operator as viewed from the front of the panel. Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages 712 or 716. In place of the "Circuit Number" indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where "3" is the cam number, and contact arrangement "OELCXX" calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 possible mounting locations. Terminal Blocks Step 6 Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance. 1. For Operator Truth Tables, see next page. Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 723 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches Contact Signaling Lights HW-U10-F (NO) ASW200 ASLW200 ASW2K00 HW-U01-F (NC) HW-U10R-F (NO-EM) Relays & Sockets HW-U01R-F (NC-LB) Contact HW-U10-F (NO) Timers HW-U01-F (NC) Right L O X R O X L X O R X O L O X R O X L X O R X O HW-U10-F (NO) ASW400 ASW300-2 ASW3K00-2 ASLW300-2 Terminal Blocks Center Right L X O O R O O X L O X X R X X O O O R O O X HW-U01R-F (NC-LB) L O X X R X X O HW-U01-F (NC) HW-U10R-F (NO-EM) Contact HW-U10-F (NO) HW-U01-F (NC) HW-U10R-F (NO-EM) HW-U01R-F (NC-LB) 724 Left X HW-U01R-F (NC-LB) ASW300-3 ASW3K00-3 ASLW300-3 Operator Position L HW-U10-F (NO) HW-U10R-F (NO-EM) Center Right L X O X R O O X L O X O R X X O L X O X R O O X L O X O R X X O Left Center Right L X O O R O O X L O X O R O X O L X O X R X O X L O X X R X X O 3 4 O O O R O X O O L O X X X R X O X X L X O O O R O X O O L O X X X R X O X X Operator Position 1 2 3 4 X O O O R O O O X L O O X O R O X O O HW-U10R-F (NO-EM) L X X O X R X O X X HW-U01R-F (NC-LB) L O X X X R X X X O HW-U01-F (NC) Contact ASW500 ASW500-1 www.IDEC.com Mounting Position Operator Position 1 2 3 4 5 HW-U10-F (NO) L X O O O O R O X O O O HW-U01-F (NC) L O O X X X R O O O X X HW-U10R-F (NO-EM) L X O O O O R O X O O O HW-U01R-F (NC-LB) L O X X X X R X O X X X Mounting Position 1 2 3 4 5 Contact Operator Position Mounting Position 2 X 5 Position Selector Switches Operator Position Left 1 L L HW-U10-F (NO) ASW400-1 Operator Position Mounting Position Mounting Position Contact Mounting Position Mounting Position HW-U01-F (NC) HW-U01R-F (NC-LB) HW-U10R-F (NO-EM) Contact Contactors Left Contact 3 Position Selector Switches ASW300-1 ASW3K00-1 ASLW300-1 Circuit Breakers Mounting Position 4 Position Selector Switches Operator Position Operator Position HW-U10-F (NO) L X O O O O R O O O O X HW-U01-F (NC) L O O O X O R O X O O O HW-U10R-F (NO-EM) L X X X O X R X O X X X HW-U01R-F (NC-LB) L O X X X X R X X X X O 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Nameplates -- TW Series Faceplates NWAL NWAQL NWAS 1.13" (29mm) 1.76" (45mm) 1.13" (29mm) o70mm 1.76" (45mm) 0.566" Signaling Lights (14.5mm) 1.0" 0.975" (25mm) (25.4mm) EMERGENCY STOP Part Number NWAL-OB (black) NWAL-OR (red) NWAQL-OB (black) NWAQL-OR (red) NWAS-OB NWAR-O Nameplate (engraved) NWAL-j NWAQL-j NWAS-j NWAR-27 Relays & Sockets Nameplate (blank) 1. In place of j, insert either the Standard Legend Code from table below or custom engraving delimited by " ". 2. Standard engravings are available at no charge. 3 NWAR-27 comes marked "Emergency Stop" as shown in drawing. Standard Legend Codes Pushbuttons Legend Code 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP STOP TEST UP I (Int'l On) O (Int'l Off) EMO 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 Legend AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER Code 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 Legend REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN Selector Switches Code Legend Code 216 217 218 219 220 221 222 223 AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 Contactors Legend Timers AUTO CLOSE DOWN EMERG.STOP FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON Pushbuttons/Selector Switches Code 1. To order engraved nameplates, add legend code to nameplate part number. Character height based on the number of characters and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. Terminal Blocks Nameplate Order Form on next page. Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 725 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Custom Engraved Nameplates Order Form -- TW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To ensure engraving accuracy, fax it to your IDEC representative. or Distributor. Your Company Name:__________________________________________ IDEC Rep/Distributor Contact:__________________________________ Your Name:__________________________________________ PO number (if known):__________________________________ Telephone:__________________________________________ IDEC Rep/Distributor Phone:__________________________________ Fax & Email:__________________________________________ IDEC Rep/Distributor Fax & Email:__________________________________ Step 1. NWAL Choose Letter Size - 7/64" or 1/8". Relays & Sockets Engraving Location 7/64" 11 characters max (for 7/64" size letters) 1/8" 9 characters max (for 1/8" size letters) Letter Size Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 9 characters. Letter Size Step 2. Sample Letter Sizes Specify Quantity. Enter the number of nameplates desired in the box on the right. 7/64" Letters: 1/8" Letters: Qty 1 Step 1. NWAQL Timers Choose Letter Size - 7/64" or 1/8". Engraving Location 2 3 4 5 6 8 9 10 11 7/64" 11 characters max (for 7/64" size letters) 1/8" 9 characters max (for 1/8" size letters) Letter Size Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 9 characters. 7 Letter Size Step 2. Sample Letter Sizes Specify Quantity. Contactors Enter the number of nameplates desired in the box on the right. 7/64" Letters: 1/8" Letters: Qty Step 1. NWAS Engraving Location A Choose Letter Size - 1/8" or 3/32". Terminal Blocks Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 14 characters. Circuit Breakers Engraving Location B 1 2 3 4 5 6 7 8 9 10 11 3/32" 20 characters max (for 3/32" size letters) 1/8" 14 characters max (for 1/8" size letters) Letter Size Letter Size 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Step 2. Step 3. Specify Location. Sample Letter Sizes Enter the number of nameplates desired in the box on the right. Enter the location of engraving (A or B), in the box on the right. 3/32" Letters: Specify Quantity. 726 Qty Location 1/8" Letters: www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Switch Engraving Order Form - TW Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To ensure engraving accuracy, fax it to your IDEC representative or Distributor. Telephone: Name: Fax: Address: Email: PO: Signaling Lights Your Company: Part Number to be Engraved: Please check one of the boxes below to indicate your choice of engraving options: o29mm, o40mm Mushroom Head Engraving Engraving Area 1 Area 2 # of Lines Letter Height Max. Characters Per Line 5/32 6 1 # of Lines Letter Height Max. Characters Per Line 5/32 5 1 6 5/32 6 2 1/8 6 5/32 5 2 1/8 5 3 1/8 6 4 3/32 5 6 3 1/8 5 4 3/32 5 1 Engraving Area 2 1 Max. Characters Per Line 5/32 5 1/8 5 5/32 7 1/8 7 Above mentioned specifications hold true for standard size pushbuttons (round and square). Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters. Enter text to be engraved: Contactors 1. 2. 3. 4. 1/8 Engraving Area 1 Letter Height Timers 1/8 # of Lines Sample Letter Sizes 1/8 Letters: Line 1: Terminal Blocks 5/32 Letters: Line 2: Line 3: Line 4: Circuit Breakers For IDEC Internal Use Only: Work Order #: 1904032203 Relays & Sockets Round Switch Square Switch 800-262-IDEC (4332) * USA & Canada 727 Switches & Pilot Devices Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - TW Series Accessories TW Series Accessories Item Appearance Description/Usage Lamp Removal Tool Rubber tool used to install or remove LED's Contact Block Remover Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used to determine panel thickness adjustment. TW-KC1 Nut Locking Wrench Used in OR-14 locking wrench to tighten locking nuts inside square bezel TW-KQ2 Metal Bezel Chrome plated bezels tighten onto operator (replacement for damaged bezels) Plastic Bezel Boot/Cover Black plastic bezels for square buttons (replacement for damaged bezels) Used to cover and protect pushbuttons Contactors OR-55 Standard octagonal units (chrome-pl.) AW-R8 Full shroud octagonal units (chrome-pl.) AW-RF8 Full shroud mushroom head units O 40mm AW-G4 Round flush units (black plastic) AW-RP1B Round extended units (black plastic) AW-FP1B Square units (black plastic) AW-Q1B Square units with full shroud (black plastic) AW-QF1B Waterproof lens cover for square pilot lights APW00LN Waterproof lens cover for square illuminated buttons APW00L Clear boot for round flush units OC-31 Clear boot for round extended units OC-32 *In place of asterisk, specify Rubber Boot color: B (black), G (green), R (red), Y (yellow) - (nitril rubber) Terminal Blocks Part Number OCW-11* Anti-Rotation Ring Ring to prevent operator base from rotating in the mounting hole. Used when nameplate is not used OGL-31 Mounting Hole Plug Black rubber plug fills unused mounting holes in panel. OB-31 Metallic Mounting Hole Plug For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of 12 kfg-cm maximum Degree of protection: IP66 Replacement Keys Replacement keys (#0) LW9Z-BM TW-SK Replacement Black Sleeve for Keyswitch Circuit Breakers AKW2B-B 728 www.IDEC.com 1904032203 Switches & Pilot Devices Appearance Description/Usage Part Number Used on flush buttons to prevent inadvertent actuation OLW-C Terminal Tab Adaptor Quick- connect terminals TW-FA4 Lock-out Adaptor Used to provide lock-out protection for pushbuttons and knob selector switches: * Up to O 40mm mushroom head size (Padlock not included.) Not applicable for e-stops. HW9Z-KL1 22mm to 30mm Adaptor Used to mount TW series control unit (except square units) O 7/8" (22mm) into a O 1-13/64" (30mm) panel cut-out. TWN-A1R8 #250 (17/64" x 3/64") single tab Contact Blocks (without side entry) These contacts are applicable for wires terminated by ring, fork, not recommended for bare wire connections. These contacts are applicable for wires terminated by ring, fork, or ferule terminals, and also bare wire connections. Relays & Sockets 1NC Signaling Lights Metal Button Guard Contact Blocks (with side entry) Switches & Pilot Devices Item o22mm - TW Series 1NO HW-U10 HW-U10-MAU HW-U10R HW-U10R-MAU (with side entry) HW-U01-F HW-U01-MAU-F HW-U01R-F HW-U01R-MAU-F (no side entry) HW-U10-F HW-U10-MAU-F HW-U10R-F HW-U10R-MAU-F (no side entry) Timers HW-U01 HW-U01-MAU HW-U01R HW-U01R-MAU (with side entry) Contactors Terminal Blocks Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 729 Switches & Pilot Devices Dimensions Pushbuttons Flush Extended Panel Thickness 0.8 to 6 LO LO CK 26.5 25 41.4 29.6 Panel Thickness 0.8 to 6 13 22.5 37 Panel thickness 1 to 6 13 24.5 37 45 47 29.6 Reset (unlock) Square Flush 49.4 (1-2 blocks) 25 30.5 Locking Ring Safety Lever Lock Panel Thickness 0.8 to 6 49.4 (1 block) 69.4 (2, 3 blocks) 89.4 (4 blocks) 13 LO CK 29.6 26.5 25 37 o40 13 29.6 Reset (unlock) 29.6 23 o29 49.4 (1-2 blocks) 69.4 (3-4 blocks) Panel thickness 1 to 6 41.4 37 o40 45 Adjust ring 29.6 40mm Push-Pull Adjust ring o40 o46 41.4 49.4 (1-2 blocks) 69.4 (3-4 blocks) Reset angle 75 o40 49.4 (1-2 blocks) 69.4 (3-4 blocks) Panel thickness 1 to 6 41.4 Panel thickness 1 to 6 Keylock Push On/Off Panel thickness 1 to 6 41.4 37 o29 Reset angle 75 47 o23.5 29.4 41.4 Adjust ring 29.6 13 24.5 29.4 13 23.2 40mm Push-Lock-Turn-Reset 13 22.5 49.4 (1-2 blocks) 69.4 (3-4 blocks) Adust ring CK 37 29mm Push-Lock-Turn-Reset Adjust ring LO o 40 41.4 41.4 o 29 49.4 (1 block) 69.4 (2 or 3 blocks) 89.4 (4 blocks) 29.4 Panel thickness 1 to 6 18.5 41.4 13 23.2 CK 26.5 25 49.4 (1 block) 69.4 (2 or 3 blocks) 89.4 (4 blocks) LO Mushroom with Full Shroud Locking Ring Safety Lever Lock 26.5 25 Panel Thickness 0.8 to 6 Panel Thickness 0.8 to 6 49.4 (1 block) 69.4 (2 or 3 blocks) 89.4 (4 blocks) o 23.6 29.4 19 40mm Mushroom Locking Ring Safety Lever Lock 49.4 (1-2 blocks) 69.4 (3-4 blocks) CK 13 69.4 (3 or 4 blocks) 29mm Mushroom Adust ring Locking Ring Safety Lever Lock LO 26.5 25 29.6 41.4 26.5 25 o29 49.4 (1 or 2 blocks) o 23.6 29.4 40mm Pushlock Key reset Timers Panel Thickness 0.8 to 6 CK 13 41.4 Relays & Sockets Signaling Lights 49.4 (1 or 2 blocks) 69.4 (3 or 4 blocks) Extended with Full Shroud Locking Ring Safety Lever Lock o29 Locking Ring Safety Lever Lock 41.4 Switches & Pilot Devices o22mm - TW Series 29.6 24.6 29.4 Square Extended Panel Thickness 0.8 to 6 LO CK 29.6 41.4 Contactors 26.5 25 Locking Ring Safety Lever Lock 49.4 (1 or 2 blocks) 69.4 (3 or 4 blocks) 13 19 24.8 29.4 Selector Switches 49.4 (1-2 blocks) 13 25 49.4 (1-2 blocks) 69.4 (3-4 blocks) 13 25 29.6 Panel thickness 1 to 6 49.4 (1-2 blocks) 69.4 (3-4 blocks) 13 19 41 37 o29 41.4 37 o29 37 o23.4 29.6 Adust ring o23.6 29.6 Circuit Breakers 69.4 (3-4 blocks) Panel thickness 1 to 6 41.4 Adust ring o29 41.4 Panel thickness 1 to 6 25 Terminal Blocks Adust ring 730 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Dimensions continued Illuminated Pushbuttons Extended with Full Shroud Square Extended Panel Thickness 1 to 6 37 25 37 o29 37 o24 Panel Thickness 1 to 6 o29 o24 Panel Thickness 1 to 6 30 Extended 13 20 30 30 29mm Push-Turn-Reset 40mm Push-Turn-Reset 37 13 30 22.5 Panel Thickness 1 to 6 Reset Angle 75 o40 37 o29 13 13 30 22.5 30 22.5 Marking plate: o13.9mm Marking plate: o13.9mm Relays & Sockets Marking plate: o13.9mm 21mm Mushroom Panel Thickness 1 to 6 Reset Angle: 75 Marking plate: Signaling Lights Marking plate: o15.5mm Marking plate: o15.5mm Panel Thickness 1 to 6 30 20 o29 19 37 13 Push-Pull 37 o40 Panel Thickness 1 to 6 13 25 30 30.5 Marking plate: o13.9mm Illuminated Selector Switches Timers 1 Contact Block with Full Voltage Adaptor Transformer (2 blocks) X1 X1 M3.5 Terminal Screws Panel Thickness 1 to 6 X2 X2 86.5 X1 M3.5 Terminal Screw Panel Thickness 1 to 6mm X2 Transformer (4 blocks) X1 M3.5 Terminal Screws Panel Thickness 1 to 6 X2 106.5 63.5 M3.5 Terminal Screws 4 Contact Blocks with Full Voltage Adaptor X1 X2 X2 Panel Thickness 1 to 6 Terminal Blocks 3 Contact Blocks with Full Voltage Adaptor X1 Contactors 2 Contact Blocks with Full Voltage Adaptor 1904032203 Circuit Breakers 68.5 800-262-IDEC (4332) * USA & Canada 731 Switches & Pilot Devices Switches & Pilot Devices o22mm - TW Series Dimensions continued Pilot Lights Round Flush APW1 Full Voltage Round Flush APW1 Transformer Terminal cover APS-PVL (supplied) Panel thickness 1 to 6 13 17.2 Round Flush Marking Type APW1B Full Voltage 3.5 Terminal Screws o23.6 29.6 Round Flush Marking Type APW1B Transformer M3.5 Terminal Screws Panel thickness 1 to 6 Dome APW2 Full Voltage Panel thickness 1 to 6 20.7 o23.6 29.6 Square Flush Marking Type APQW1B Transformer M3.5 Terminal Screws Panel thickness 1 to 6 13.1 16 24.7 29.6 69.5 28.5 13.1 16 37 36 37 29.6 Panel thickness 1 to 6 29.6 28.5 34.3 13 24.5 59.5 o23.6 29.6 Square Flush Marking Type APQW1B Full Voltage Terminal cover APS-PVL (supplied) o29 M3.5 Terminal Screws T transformer 36 37 13 24.5 o23.6 29.6 Dome APW2 Transformer Terminal Cover APS-PVL (supplied) Panel thickness 1 to 6 28.5 34.3 Timers 13 17.2 69.5 o29 Relays & Sockets o23.6 29.6 37 13 17.2 69.5 20.7 20.7 o29 37 Panel thickness 1 to 6 o29 37 20.7 o29 13 17.2 59.5 o23.6 29.6 37 Signaling Lights 28.5 34.3 M3.5 Terminal Screws T transformer 36 37 o29 Panel thickness 1 to 6 24.7 29.6 Adust ring Panel thickness 1 to 6 13 25 o23.4 29.6 Circuit Breakers Terminal Blocks 49.4 (1 block) 69.4 (2-3 blocks) 89.4 (4blocks) 37 o29 41.4 Contactors Illuminated Selector Switches 732 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Dimensions continued Panel Cut-Out Diagram Part R0.8 max. o22 +0 .4 0 24.1 50 (45 min.) Illuminated Pushbuttons 30 (*1) Selector Switches Signaling Lights * The minimum mounting centers are applicable to switches with one layer of contact blocks (one to two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. 1*) o40 mm mushroom button type: 40 mm minimum 1*) 2-position, 3-position lever selector switch: 39 mm minimum 1*) 4-position, 5-position lever selector switch: 50 mm minimum * When high temperature is expected, take necessary measures such as securing sufficient mounting centers or using a cooling fan. * The 3.2 +0.2 0 mm recess is for preventing rotation and is not necessary when the nameplate or anti-rotation ring is not used. Pilot Light +0.4 0 .3 Pushbuttons +0.2 0 3.2 Dimension All dimensions in mm. Illuminated Selector Switches Relays & Sockets 1.The O 0.137" (O 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used. 2. *>1.404" (36mm) for 2- or 3-position. >1.95" (50mm) for 4- or 5-position. Accessory Dimensions OCW-11 Pushbutton Rubber Boot 0.8 18.5 1.6t Button installed AW-RP1B Round Plastic Bezel 82.5 Panel Thickness 0.8 to 3.2 o29 3.5 3.5 AW-FP1B Round Plastic w/Full Shroud o29 AW-QF1B Square Full Shroud 13 Contactors 30 6.5 R6 93 Extended 13 HW9Z-KL1 Lock-out Adaptor 21 o25 Button installed Timers Flush o29 o31 o32 15 9 19.8 o27.4 .5 M22 P1.0 o26 Mounting Centers 50 min. 10.2 o22 R42 o22.5 9 M22 P1.0 18.6 OB-31 Mounting Hole Rubber Plug o32 OLW-C Metal Button Guard o31 OGL-31 Anti-Rotation Ring 70 24 (inside) 2.2 o2 0 ) o5 44.4 :o (ID Key hole o8 29.5 30 30 Waterproof Rubber Gasket 0.5t Finger-Safe Cover Dimensions APS-PVL 7.2 Terminal Blocks 15.5 O7 .0 22.8 39.1 Circuit Breakers 1904032203 800-262-IDEC (4332) * USA & Canada 733 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - TW Series Component Construction and General Instructions -- TW Series Instructions for Switches and Pilot Devices TW Series: Adjustment for Panel Thickness Lens or Button The panel thickness ring provides adjustment from 0.04" to 0.24" (1 to 6mm) in 0.004" (0.1mm) increments. Rotate the ring until the markings around the periphery are aligned for the desired thickness, as shown below. Scale on Adjustment (in 0.1 mm) Bezel 0 0.1 0.2 Option: Nameplate 0.3 0.4 0.5 0.7 0.8 0.9 0 0.1 mm 1 2 3 Operator 4 5 1 mm Panel Thickness Scale (in 1 mm on the operator) 6 (Panel) A Waterproof Gasket Relays & Sockets 0.6 Waterproof Lens (Round lens used on square pushbuttons and pilot lights only), Adjustment Ring Panel Thickness Base 2 4 6 3 5 3 5 4 6 Ex. Panel thickness 2.6 mm Ex. Panel thickness 2 mm Note: When a nameplate or an anti-rotation ring is used, add 0.03" (0.8mm) to the panel thickness dimension. An adjustment for panel thicknesses shown below can be made quickly by using the contact block remover tool. Contact Block Removal Tool (TW-KC1) 1.6mm 2.3mm Panel Thickness Adjustment Ring 3.5mm LED Lamp Holder Timers 1mm Contact Block Contactors Lead Holder 2mm 3.2mm Contact Block Removal Tool Options Full Size Transformer: Circuit Breakers Terminal Blocks Full Voltage Adaptor: 734 www.IDEC.com 1904032203 Switches & Pilot Devices o22mm - TW Series Switches & Pilot Devices Instructions continued Pilot Lights and Pushbuttons IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up. Octagonal and Round Bezels Octagonal and round bezels screw into the operator. Use a locking ring wrench (optional) for secure tightening and easy removal. Round flush and extended buttons snap onto the operator base. Mushroom buttons screw onto the operator base. Round Marking Unit Lens Insert marking plate under lens Marking Plate Press in Press in round flush and extended lens. Screw in mushroom lens Signaling Lights Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Relays & Sockets Square Bezels Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally, install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base. Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on. Illuminated Pushbutton Insert Marking Plate Insert marking plate under lens Timers Insert marking plate under lens Square Lens Pilot Light Square Lens Press in Square Marking Units Marking Plate Lens Retainer Waterproof Lens Contactors To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16" screwdriver into one of the recesses. Terminal Blocks Marking Plate Engraving Area Shape Round Engraving Area Used With Part Number O 0.55" (14mm) Illuminated pushbuttons ALW2B Pilot lights APW2B O 0.55" (14mm) Illuminated mushroom ALW3B Square q 0.83" (21mm) Square pilot lights APQW1B Square q 0.83" (21mm) Square illuminated pushbuttons ALQW2B 1904032203 800-262-IDEC (4332) * USA & Canada Circuit Breakers O 0.55" (14mm) Mushroom 735 Switches & Pilot Devices Instructions, continued Selector Switches The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the handle and then press handle into the operator, as shown below. Recess Press in color insert Press in handle Signaling Lights Switches & Pilot Devices o22mm - TW Series Illuminated Selector Switch Selector Switch (non-illuminated) Relays & Sockets Remove color insert before pulling out the handle. Standard Operating Positions 2-Postion, 90 1 3-Postion, 45 1 2 0 4-Postion, 45 1 2 2 5-Postion, 30 3 2 3 1 4 5 4 Positions: Non-Illuminated 3-Position Operators 1 0 1 2 1 0 0 2 Timers 2 Installation of LED Illuminated Units Transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode with DC power supply to protect against surges and noise.) Contactors Ter minal X1 LED Terminal X2 Circuit Breakers Terminal Blocks Diode 736 www.IDEC.com 1904032203