DC Voltage Simple Logger (R) Models L410 & L430 Specifications Features Applications * Two models to choose from: Model L410 0 to 100mVDC Model L430 0 to 10VDC * Programmable scales via software * Programmable units via software * Inputs via color-coded safety banana jacks * RS-232 output * One button operation * Accuracy : 1% of Reading + Resolution * Double Insulation * CE Mark * * * * Circuit design troubleshooting Sensor monitoring Battery testing Power supply profiling ORDERING INFORMATION ELECTRICAL Number of Channels: One Measurement Range: 0 to 100mVDC (L410) 0 to 10VDC (L430) Input Impedance: L410 and L430: 1M Input Connection: Recessed safety 4mm banana jacks Resolution: 8 Bit L410: 50V max L430: 5mV max Accuracy*: 1% of Reading + Resolution (see inside back cover for details) Sample Rate: 4096/hr maximum Storage Technique: Time Extension RecordingTM (TXRTM) Data Storage: 8192 readings Power: 9V Alkaline battery Battery Life: Up to one year of recording @ 25C Output: RS-232 via DB-9 connector Indicators: Red LED flashes once every two seconds in STANDBY mode, twice every two seconds in LOGGING mode, and is off in OFF mode Controls: One button used to start and stop recording sessions and to turn the data logger on and off Working Voltage: 30VAC maximum MECHANICAL Size: 2 7/8 x 2 5/16 x 15/8" (73 x 59 x 41mm) Weight: (with battery) 5 oz (140g) Mounting: Base plate mounting holes or Velcro(R) pads supplied loose ENVIRONMENTAL Operating Temperature: -4 to +158F (-20 to +70C) Storage Temperature: -4 to +174F (-20 to +80C) Relative Humidity: 5 to 95% non-condensing Safety: EN 61010, 30V Cat. III CATALOG NO. Simple Logger Model L410 (DC Voltage, 0 to 100mVDC Input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2114.05 (R) Simple Logger(R) Model L430 (DC Voltage, 0 to 10VDC Input). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2114.07 All DC voltage Simple Loggers(R) are supplied with software (CD-ROM), 6 ft DB-9 RS-232 serial cable, 9V Alkaline battery and user manual Accessories Voltage Leads, (2) with clips, 5 ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2118.51 DC Voltage Simple Logger(R) Models L410 & L430 (pdf) Rev. 03 12/05 Technical Assistance (800) 343-1391 www.aemc.com 1 of 5 Simple Logger (R) Software Features Computer Requirements * Very easy to setup and use -- no programming required * Print both graphs and tabular listings * Statistics appear on screen: Max, Min, Avg, Date and Time * Paste graphs into other applications * 486 or higher * 8MB of RAM * Windows(R) 95/98/2000/ME/XP or Windows (R)NT * On-Line display of data logger values * Programmable scale and units for all DC loggers. Automatic selection for AC loggers * One serial port not in use by any other device * Zoom capability with automatic statistics update * User programmable High and Low limits (Model L215) * 8MB hard drive space for program and 400kB max per file stored * User keyed text annotations * User programmable record modes - inside or outside of limits (Model L215) * Automatically displays values at the cursor position * Export data to spreadsheet and database software * Automatic baud rate selection (version 6.0 or later) Plot graphs and view statistics quickly and easily when you download data from Simple Logger (R) to your computer. Scale and time axis update automatically. Click and drag your mouse to zoom up the desired area of the graph for better viewing. The Min, Max and Average statistics at the bottom of the graph update automatically with zoom window. Click the Annotate button to add a title and descriptive information to your graph. This information can be stored and printed with a graph. DC Voltage Simple Logger(R) Models L410 & L430 (pdf) Rev. 03 12/05 Technical Assistance (800) 343-1391 www.aemc.com 2 of 5 On-line display of data Automatic update of Y data at cursor position Annotate button Plot area with value and time data shown on the X and Y axis Graph Statistics Click the Annotate button to add a title and descriptive information to your graph. This information can be stored and printed with a graph. DC Voltage Simple Logger(R) Models L410 & L430 (pdf) Rev. 03 12/05 Technical Assistance (800) 343-1391 www.aemc.com 3 of 5 Simple Logger (R) Software Click the scale button in the file menu to create custom scales and engineering units for DC voltage (Models L410 & L430) and DC current loggers (Model L320). Click and drag your mouse to zoom up the desired area of the graph for better viewing. The Min, Max and Average statistics at the bottom of the graph update automatically when the graph is zoomed. DC Voltage Simple Logger(R) Models L410 & L430 (pdf) Rev. 03 12/05 Technical Assistance (800) 343-1391 www.aemc.com 4 of 5 Accessories Split Core AC and DC Current Probes Current Probe and Simple Logger (R) Compatibility Series o = 0.78" o = 1.18" Probe Model Ratio Output Signal Current Voltage Output Connection Catalog No. Logger Model MN211 1000:1 0.5 to 240A - 1mAAC/AAC - Lead 2115.73 L110 MN213 1000:1 0.5 to 240A - 1mAAC/AAC - Lead 2115.75 L110 MN251 - 0.1 to 240A - - 1mVAC/AAC Lead 2115.77 L100 MD301 - 2 to 500A - - 1mVDC/AAC Lead 1201.07 L430 MD303 1000:1 4 to 500A - 1mAAC/AAC - Lead 1201.21 L110 MD305 1000:1 1 to 600A - 1mAAC/AAC - Lead 1201.36 L110 MD314 - 4 to 500A - - 1mVAC/AAC Lead 2110.75 L100 MR410* - 1 to 400A - - 1 to 600A - 1mV/AAC 1mV/ADC Lead Lead 1200.70 1200.70 L100 (AC) L430 (DC) - 0.2 to 40A 0.5 to 400A - 0.5 to 600A - 10mV/AAC 1mV/AAC Lead 1200.68 L100 (AC) - - 0.4 to 60A 0.5 to 600A 10mV/ADC 1mV/ADC Lead 1200.68 L430 (DC) - 1 to 1000A - - 1 to 1500A - 1mV/AAC/DC 1mV/AAC/DC Lead 1200.71 L100 (AC) L430 (DC) - 0.2 to 100A 0.5 to 1000A 0.4 to 150A 0.5 to 1500A - 10m V/AAC 1mV/AAC Lead 1200.69 L100 (AC) 0.2 to 100A 0.5 to 1000A 0.4 to 1500A 0.5 to 1500A 10mV/ADC 1mV/ADC Lead 1200.69 L430 (DC) L110 MR411* o = 1.18" MR520* MR521* o = 1.6" o = 2.05" Measurement Range AC DC SR604 1000:1 0.1 to 1000A - 1mAAC/AAC - Lead 2113.44 SR652 - 0.1 to 1000A - - 1mVAC/AAC Lead 2113.46 L100 SR704 1000:1 1mA to 1000A - 1mAAC/AAC - Lead 2116.30 L110 SR752 - 0.1 to 1000A - - 1mVAC/AAC Lead 2116.32 L100 *Caution: Do not use DC loggers with AC probes or AC loggers with DC Probes Not all models are UL approved; please consult factory. DC Voltage Simple Logger(R) Models L410 & L430 (pdf) Rev. 03 12/05 Technical Assistance (800) 343-1391 www.aemc.com 5 of 6 2114.26 Simple Logger (R) Software Upgrade for all models (Receive software upgrade notices when warranty registration is on file) 2111.31 Safety Grip Probes, set of two DC Voltage Simple Logger(R) Models L410 & L430 (pdf) Rev. 03 12/05 Technical Assistance (800) 343-1391 www.aemc.com 6 of 7 Contact Us United States & Canada: Chauvin Arnoux(R), Inc. d.b.a. AEMC (R) Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 * Fax (508) 698-2118 www.aemc.com Customer Support - for placing an order, obtaining price & delivery: customerservice@aemc.com Sales Department - for general sales information: sales@aemc.com Repair and Calibration Service - for information on repair & calibration, obtaining a user manual: repair@aemc.com Technical and Product Application Support - for technical and application support: techinfo@aemc.com Webmaster - for information regarding www.aemc.com: webmaster@aemc.com South America, Central America, Mexico, Caribbean, Australia & New Zealand: Chauvin Arnoux(R), Inc. d.b.a. AEMC (R) Instruments 15 Faraday Drive Dover, NH 03820 USA (978) 526-7667 * Fax (978) 526-7605 export@aemc.com www.aemc.com All other countries: Chauvin Arnoux SCA 190, rue Championnet 75876 Paris Cedex 18, France 33 1 44 85 45 28 * Fax 33 1 46 27 73 89 info@chauvin-arnoux.com www.chauvin-arnoux.com DC Voltage Simple Logger(R) Models L410 & L430 (pdf) Rev. 03 12/05 Technical Assistance (800) 343-1391 www.aemc.com 7 of 7