Notes
A.
Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B.
Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
C.
The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
Mini-Circuits
®
www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com
Typical Performance Data
Electrical Specifi cations
Maximum Ratings
Operating Temperature -45°C to 100°C
Storage Temperature -55°C to 100°C
Outline Drawing
Outline Dimensions ( )
HAT-1+
ATTENUATION
0.8
0.9
1.0
1.1
1.2
1.3
0 400 800 1200 1600 2000
FREQUENCY (MHz)
ATTENUATION (dB)
inch
mm
HAT-1+
50Ω 1W 1dB DC to 2000 MHz
Fixed Attenuator
REV. F
M131858
EDR-5087/1-15
HAT-1+
RVN/LC/CP/AM
120504
Coaxial
.62 1.94 grams
15.75 49.28
CASE STYLE: FF747
Connectors Model Price Qty.
BNC Male-BNC Female HAT-1+ 9.95 ea. (1-9)
HAT-1+
VSWR
1.00
1.02
1.04
1.06
1.08
1.10
0 400 800 1200 1600 2000
FREQUENCY (MHz)
VSWR
* Flatness = variation over band divided by 2.
Features
• excellent VSWR, 1.05:1 typ.
• excellent fl atness, 0.15 dB typ. to 2000 MHz
• usable to 4000 MHz
Applications
• PCS
• instrumentation
• cellular
FREQ.
RANGE
(MHz)
ATTENUATION
(dB)
Flatness*
VSWR
(:1)
MAX.
INPUT
POWER
DC-0.5
GHz
DC-1
GHz
DC-2
GHz
Total
Band
Max.
DC-0.5
GHz
DC-1
GHz
DC-2
GHz
(W)
fL--fUNom. Ty p . Ty p . Ty p . Ty p . Ty p . Ty p .
DC-2000 1±0.2 0.05 0.10 0.15 0.25 1.05 1.10 1.10 1.0
Frequency
(MHz)
Attenuation
(dB)
VSWR
(:1)
10.00 0.98 1.00
50.00 1.00 1.01
100.00 1.02 1.01
250.00 1.06 1.03
400.00 1.05 1.04
600.00 1.12 1.06
1000.00 1.12 1.08
1500.00 1.19 1.07
1750.00 1.17 1.05
2000.00 1.21 1.04
Electrical Schematic
FEMALEMALE R1
R2
R3
Permanent damage may occur if any of these limits are exceeded.
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications