RoHS
Compliant
Resonance frequencies
MMK 5
Resonance frequencies
MMK7.5 ... 37.5
Z (Ω)
10
0.1 1.0 10
100 MHz
1.0
0.1
0.01
Z (Ω)
10
0.1 1.0 10
100 MHz
1.0
0.1
0.01
50 63 100 250 400 630 1000
30 40 63 160 200 220 250
0.001 0.001 0.001 0.001 0.001 0.001 0.001
–10.0 –82 –82 –39 –18 –6.8 –4.7
±20%, ±10% standard, ±5%.
–55 ... +100°C
Above +85°C DC and AC voltage derating is 1.25%/°C.
+85°C
IEC 60068-1, 55/100/56
DIN 40040, FME
–55 ... +100°C (+125°C)
Average relative humidity ≤ 75 %
RH = 95% for 30 days per year.
RH = 85% for further days limited by average value per
year, occasional slight condensation permitted.
1.6 x UR VDC for 2s
Max. 2% after a 2 year storage period at a temperature
of +10 ... +40°C and a relative humidity of 40...60%.
Operational life > 200 000 h.
Failure rate < 3 FIT, T = +40°C, U = 0.5 x UR.
Failure criteria according to DIN 44122.
dU/dt according to article table. For peak to peak
voltages lower than rated voltage (UPP < UR), the
specified dU/dt can be multiplied by the factor UR/UPP
.
+400 (±200) ppm/°C at 1 kHz
Approximately 6 nH/cm for the total length of capacitor
winding and the leads.
MMK
• Metallized polyester
• According to IEC 60384-2, DIN 44122
TYPICAL APPLICATIONS
Bypassing, signal coupling. General
purpose for highest reliability.
CONSTRUCTION
Metallized polyester film capacitor. Radial
leads of tinned wire are electrically welded
to the contact metal layer on the ends of
the capacitor winding. Encapsulation in
self-extinguishing material meeting the
requirements of UL 94V-0.
TECHNICAL DATA
L
H
B
pl
Ød
0.5
b
p d std l max l b
7.5 ± 0.4 0.6 4
+1
20 ± 0.4
10.0 ± 0.4 0.6 6
-1
30 ± 0.4
15.0 ± 0.4 0.8 6
-1
30 ± 0.4
22.5 ± 0.4 0.8 6
-1
30 ± 0.4
27.5 ± 0.4 0.8 6
-1
30 ± 0.4
37.5 ± 0.5 1.0 6
-1
30 ± 0.7
p d std I max I b
5.0 ± 0.4 0.5 4+1 20 ± 0.4
7.5 ± 0.4 0.6 4+1 20 ± 0.4
10.0 ± 0.4 0.6 4+1 30 ± 0.4
15.0 ± 0.4 0.8 4+1 30 ± 0.4
22.5 ± 0.4 0.8 4+1 30 ± 0.4
27.5 ± 0.4 0.8 4+1 30 ± 0.4
37.5 ± 0.5 1.0 4+1 30 ± 0.7
Rated voltage UR, VDC
Rated voltage UR, VAC
Capacitance, µF
Capacitance tolerance
Category temperature range
Voltage derating
Rated temperature
Climatic category
Test voltage
Capacitance drift
Reliability
Maximum pulse steepness:
Temperature coefficient
Self inductance
ENVIRONMENTAL TEST DATA
Damp heat test Test conditions: T = +40°C, RH = 93%, t = 56 days.
Test criteria: ∆ C/C ≤±5%,
∆ tan∂ ≤ 0.005 (1kHz),
IR after test 0.5 x IR min.
Endurance test Test conditions: T = +100°C, U = 1.25 x (0.8 x UR),
Test criteria: t = 2000 h.
∆ C/C≤ ±5%,
∆ tan∂ ≤ 0.005 (1kHz)
∆ tan∂ ≤ 0.010 (100kHz)
IR after test 0.5 x IR min.
Not for new design. Use new F611-F612 Series.