1
Fuseholder Blocks & Clips OGN
https://www.schurter.com /PG02
Circuit Protection
Fuseholder Open Design, 5 x 20 mm, THT, var. Covers, IEC 60335-1
See below:
Approvals and Compliances
500 VAC · 4 W / 16 A (VDE) · 500 V · 16 A (UL/CSA)
Description
- For appliances in unattended use
- Low profile fuse block with insulation walls
Applications
- Household appliances
Weblinks
pdf data sheet, html datasheet, General Product Information, Packaging
details, Distributor-Stock-Check, Accessories, Detailed request for
product, Microsite
Technical Data
Shock-Safe Category PC1
Fuse-Link 5 x 20 mm
Mounting PCB
Attachment Screw, rivet or THT
Terminal Solder THT
Rated Voltage 500 VAC (VDE), 500 V (UL/CSA)
Rated current 10/16 A (VDE), 16 A (UL/CSA)
Rated Power Acceptance IEC 4 W / 16 A @ Ta 23 °C
4 W / 10A with black cover
2.5 W / 10 A with transparant cover, see
derating curves
Degree of Protection IP 20 (with cover)
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category 40/085/21 acc. to IEC 60068-1
Material: Socket see variants
Material: Cover Thermoplastic UL 94V-0
Material: Terminals Tin-Plated Copper Alloy
Unit Weight 1.7 g
Storage Conditions 0 °C to 60 °C, max. 70% r.h.
Product Marking , Type, Rated Voltage, Rated current,
Power Rating, Dielectric strength
Soldering Methods Wave
Soldering Profile
Solderability 245 °C / 3 sec acc. to IEC 60068-2-20,
Test Ta, method 1
Resistance to Soldering Heat 260 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 1
Contact Resistance ≤ 10 mΩ at 100 mA acc. to IEC
60127-6
Dielectric Strength > 3 kV between life parts
(50 Hz: 1 min)
Impulse Withstand Voltage > 4 kV between life parts
Insulation Resistance ≥ 10 MΩ
(500 VDC: 1 min)
Overvoltage Category III acc. to IEC 60664-1
Pollution Degree 3 acc. to IEC 60664-1
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-
ments by SCHURTER.