PDC Series - AGM Deep Cycle Batteries
Discharge Characteristics Float Charging Characteristics
Cycle Life in Relation to Depth of DischargeTemperature Effects in Relation to Capacity
1 2 46 8 10 20 40 60 24 6 8 10 20
min h
4.0
4.5
5.0
5.5
6
6V Battery
(V)
12V Battery
(V)
.0
6.5
0 200 400 600 800 1000 1200 1400 1600 1800
20
40
60
80
100
120
0
-
20 -10 010 20 30 40 50
0
20
40
60
80
100
120
0.05CA
0.10 CA
0.20CA
1CA
0.5CA
2CA
3CA
810 12
0
46
60
80
100
02
20
40
A
B
C
04812 16 20 24 28
% (A) (V/cell)
Terminal Voltage (V)
Capacity Ratio (%)
Capacity (%)
Remaining Capacity (%)
Temperature(°C)
Temperature: 25°C Charge
Volume
Charging
Current
Charged
Voltage Charge at 0.1C Amp Initial Charging Current and
2.45V/Cell Constant Voltage at 25°C
Discharge Time Charging Time (Hours)
Number of Cycles
Storage Time (Months)
A
B
C
10°C
100%
DOD
50%
DOD
30%
DOD
30°C
40°C
No supplementary charge required
(Carry out supplementary charge before use if 100% capacity is required.)
Supplementary charge required before use.Optional charging way as below:
1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.
2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
3.Charged for 8~10hours at limted current 0.05CA .
Supplementary charge may often fail to recover the capacity.
The battery should never be left standing till this is reached
25°C
Testing condition
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 2.45V/cell,max. 0.25CA;
Charging volume:125% of discharged capacity.
13.0
12.0 120
0.1C
0.08C
0.06C
0.04C
0.02C
2.5
2.4
2.3
2.2
2.1
0C
100
80
60
40
20
11.0
10.0
9.0
8.0
0.054C
0.1C
.214C
.365C
.646C
1.1C
2.6C
3.8C
Charged Volume
Charge Voltage
(Constant 2.45V/Cell)
After 50% Discharge
After 100% Discharge
Charging Current
(Initial at 0.1C Amp)
1 2 46 8 10 20 40 60 24 6 8 10 20
min h
4.0
4.5
5.0
5.5
6
6V Battery
(V)
12V Battery
(V)
.0
6.5
0 200 400 600 800 1000 1200 1400 1600 1800
20
40
60
80
100
120
0
-
20 -10 010 20 30 40 50
0
20
40
60
80
100
120
0.05CA
0.10 CA
0.20CA
1CA
0.5CA
2CA
3CA
810 12
0
46
60
80
100
02
20
40
A
B
C
04812 16 20 24 28
% (A) (V/cell)
Terminal Voltage (V)
Capacity Ratio (%)
Capacity (%)
Remaining Capacity (%)
Temperature(°C)
Temperature: 25°C Charge
Volume
Charging
Current
Charged
Voltage Charge at 0.1C Amp Initial Charging Current and
2.45V/Cell Constant Voltage at 25°C
Discharge Time Charging Time (Hours)
Number of Cycles
Storage Time (Months)
A
B
C
10°C
100%
DOD
50%
DOD
30%
DOD
30°C
40°C
No supplementary charge required
(Carry out supplementary charge before use if 100% capacity is required.)
Supplementary charge required before use.Optional charging way as below:
1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.
2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
3.Charged for 8~10hours at limted current 0.05CA .
Supplementary charge may often fail to recover the capacity.
The battery should never be left standing till this is reached
25°C
Testing condition
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 2.45V/cell,max. 0.25CA;
Charging volume:125% of discharged capacity.
13.0
12.0 120
0.1C
0.08C
0.06C
0.04C
0.02C
2.5
2.4
2.3
2.2
2.1
0C
100
80
60
40
20
11.0
10.0
9.0
8.0
0.054C
0.1C
.214C
.365C
.646C
1.1C
2.6C
3.8C
Charged Volume
Charge Voltage
(Constant 2.45V/Cell)
After 50% Discharge
After 100% Discharge
Charging Current
(Initial at 0.1C Amp)
1 2 46 8 10 20 40 60 24 6 8 10 20
min h
4.0
4.5
5.0
5.5
6
6V Battery
(V)
12V Battery
(V)
.0
6.5
0 200 400 60 0 80 0 1000 1200 1 4 0 0 1 6 0 0 1800
20
40
60
80
100
120
0
-
20 -10 010 20 30 40 50
0
20
40
60
80
100
120
0.05CA
0.10 CA
0.20CA
1CA
0.5CA
2CA
3CA
810 12
0
46
60
80
100
02
20
40
A
B
C
04812 16 20 24 28
% (A) (V/cell)
Terminal Voltage (V)
Capacity Ratio (%)
Capacity (%)
Remaining Capacity (%)
Temperature(°C)
Temperature: 25°C Charge
Volume
Charging
Current
Charged
Voltage Charge at 0.1C Amp Initial Charging Current and
2.45V/Cell Constant Voltage at 25°C
Discharge Time Charging Time (Hours)
Number of Cycles
Storage Time (Months)
A
B
C
10°C
100%
DOD
50%
DOD
30%
DOD
30°C
40°C
No supplementary charge required
(Carry out supplementary charge before use if 100% capacity is required.)
Supplementary charge required before use.Optional charging way as below:
1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.
2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
3.Charged for 8~10hours at limted current 0.05CA .
Supplementary charge may often fail to recover the capacity.
The battery should never be left standing till this is reached
25°C
Testing condition
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 2.45V/cell,max. 0.25CA;
Charging volume:125% of discharged capacity.
13.0
12.0 120
0.1C
0.08C
0.06C
0.04C
0.02C
2.5
2.4
2.3
2.2
2.1
0C
100
80
60
40
20
11.0
10.0
9.0
8.0
0.054C
0.1C
.214C
.365C
.646C
1.1C
2.6C
3.8C
Charged Volume
Charge Voltage
(Constant 2.45V/Cell)
After 50% Discharge
After 100% Discharge
Charging Current
(Initial at 0.1C Amp)
1 2 46 8 10 20 40 60 24 6 8 10 20
min h
4.0
4.5
5.0
5.5
6
6V Battery
(V)
12V Battery
(V)
.0
6.5
0 200 400 60 0 80 0 1000 1200 1 4 0 0 1 6 0 0 1800
20
40
60
80
100
120
0
-
20 -10 010 20 30 40 50
0
20
40
60
80
100
120
0.05CA
0.10 CA
0.20CA
1CA
0.5CA
2CA
3CA
810 12
0
46
60
80
100
02
20
40
A
B
C
04812 16 20 24 28
% (A) (V/cell)
Terminal Voltage (V)
Capacity Ratio (%)
Capacity (%)
Remaining Capacity (%)
Temperature(°C)
Temperature: 25°C Charge
Volume
Charging
Current
Charged
Voltage Charge at 0.1C Amp Initial Charging Current and
2.45V/Cell Constant Voltage at 25°C
Discharge Time Charging Time (Hours)
Number of Cycles
Storage Time (Months)
A
B
C
10°C
100%
DOD
50%
DOD
30%
DOD
30°C
40°C
No supplementary charge required
(Carry out supplementary charge before use if 100% capacity is required.)
Supplementary charge required before use.Optional charging way as below:
1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.
2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
3.Charged for 8~10hours at limted current 0.05CA .
Supplementary charge may often fail to recover the capacity.
The battery should never be left standing till this is reached
25°C
Testing condition
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 2.45V/cell,max. 0.25CA;
Charging volume:125% of discharged capacity.
13.0
12.0 120
0.1C
0.08C
0.06C
0.04C
0.02C
2.5
2.4
2.3
2.2
2.1
0C
100
80
60
40
20
11.0
10.0
9.0
8.0
0.054C
0.1C
.214C
.365C
.646C
1.1C
2.6C
3.8C
Charged Volume
Charge Voltage
(Constant 2.45V/Cell)
After 50% Discharge
After 100% Discharge
Charging Current
(Initial at 0.1C Amp)
Model Nominal
Voltage
Rated Capacity AH Length Width Height Total Height Weight Terminal Type
20-hr 10-hr in. mm. in. mm. in. mm. in. mm. lbs. kgs.
PDC-1275 12 7.5 7.2 5.94 151 2.56 65 3.72 94.5 3.94 100 5.5 2.5 F2
PDC-1285 12 8.5 8.0 5.94 151 2.56 65 3.72 94.5 3.94 100 6.0 2.7 F2
PDC-12140 12 14.0 13.0 5.96 151.5 3.92 100 3.82 97 3.98 101 9.5 4.3 F2
PDC-12200 12 21.0 20.0 7.15 181.5 3.01 77 6.73 171 6.73 171 15 6.9 B (T12)
PDC-12260 12 28.0 26.0 6.56 166.5 6.89 175 4.92 125 4.92 125 21 9.4 NB
PDC-12260H 12 26.0 24.0 6.50 165 4.92 125 6.89 175 6.89 175 21 9.5 B (T12)
PDC-12350 12 35.0 33.0 7.68 195 5.12 130 6.46 164 7.09 180 25 11.2 NB
PDC-12400 12 40.0 38.0 7.76 197 6.50 165 6.69 170 6.69 170 32 14.5 B (T6)
PDC-12600 12 60.0 55.0 9.04 230 5.45 138 8.27 210 8.66 220 39 17.7 U (T9)
PDC-12800 12 80.0 75.0 10.24 260 6.61 168 8.27 210 9.06 230 50 22.7 U (T14)
PDC-121000 12 100 92.0 12.05 306 6.61 168 8.27 210 8.50 216 61 27.5 U (T14)
PDC-121100 12 107 100.0 12.99 330 6.81 173 8.46 215 8.66 220 67 30.4 B (T6)
PDC-122000 12 214 200.0 20.55 522 9.45 240 8.58 218 8.82 224 138 62.5 B (T11)