Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type: B41851, B43851
Date: December 2010
© EPCOS AG 2011. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
General-purpose grade capacitors
Applications
General-purpose applications in the entertainment industry
Semi-professional to professional application range
For filtering, coupling and pulse circuits
Switch-mode power supplies
Features
Compact dimensions
High CV product, i.e. very compact
RoHS-compatible
Construction
Radial leads
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Minus pole marking on the insulating sleeve
Case with safety vent from diameter 6.3 mm
Delivery mode
Terminal configurations and packing:
Bulk
Taped, Ammo pack
Cut (see chapter "Single-ended Taping, packing and lead
configurations, Cut leads (Chapter B)")
Kinked (see chapter "Single-ended Taping, packing and
lead configurations, Kinked leads (Chapter B)")
PAPR (protection against polarity reversal):
crimped leads, J leads, bent leads
Refer to chapter "Single-ended capacitors Taping, packing
and lead configurations" for further details.
Single-ended capacitors B41851, B43851
Standard series 105 °C
Page 2 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Specifications and characteristics in brief
Series B41851 B43851
Rated voltage VR6.3 ... 100 V DC 160 ... 450 V DC
Surge voltage VS1.15 VR1.1 VR
Rated capacitance CR0.1 ... 10000 µF 0.47 ... 680 µF
Capacitance tolerance ±20% M±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
For capacitance higher than 1000 µF add 0.02 for every increase of
1000 µF.
VR(V DC) 6.3 10 16 25 35 50 63 100 160 ...
450
tan δ(max.) 0.28 0.24 0.20 0.16 0.14 0.12 0.12 0.10 0.20
Leakage current Ileak
(20 °C, 5 min)
or 3 µA, whichever is greater
Self-inductance ESL Diameter (mm) 6.3 8 ... 12.5 16 18 20 ...
25
ESL (nH) 15 20 26 34 40
Useful life
105 °C; VR; IAC,R > 2000 h > 3000 h
40 °C; VR; 1.8 IAC,R > 250000 h
40 °C; VR; 2.1 IAC,R > 250000 h
Requirements C/C ±45% of initial value
tan δ 3 times initial specified limit
Ileak initial specified limit
Voltage endurance test
105 °C; VR1000 h 1000 h
Post test requirements C/C ±30% of initial value
tan δ 2 times initial specified limit
Ileak initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Frequency range 10 Hz ... 2 kHz, displacement amplitude 1.5 mm,
acceleration max. 20 g, duration 3 ×2 h.
Capacitor rigidly clamped by the aluminum case.
IEC climatic category To IEC 60068-1:
VR250 V: 40/105/56 (40 °C/+105 °C/56 days damp heat test)
VR350 V: 25/105/56 (25 °C/+105 °C/56 days damp heat test)
Sectional specification IEC 60384-4
B41851, B43851
Standard series 105 °C
Page 3 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Dimensional drawings
With stand-off rubber seal
Diameters (mm):
6.3, 10, 12.5, 16, 18, 22, 25
With flat rubber seal
Diameters (mm):
5, 8, 20
Safety vent for diameter 6.3 mm.
Dimensions and weights
Dimensions (mm) Approx. weight
d +0.5 l a ±0.5 b g
5 11 +1.0 2.0 0.50 ±0.05 0.5
6.3 11 +1.0 2.5 0.50 ±0.05 0.7
8 11.5 +1.5 3.5 0.60 ±0.05 1.0
10 12.5 +1.0 5.0 0.60 ±0.05 1.6
10 16 +1.0 5.0 0.60 ±0.05 1.9
10 20 +2.0 5.0 0.60 ±0.05 2.6
12.5 20 +2.0 5.0 0.60 ±0.05 3.6
12.5 25 +2.0 5.0 0.60 ±0.05 4.5
16 20 +2.0 7.5 0.80 ±0.05 5.5
16 25 +2.0 7.5 0.80 ±0.05 7.5
16 31.5 +2.0 7.5 0.80 ±0.05 7.8
18 31.5 +2.0 7.5 0.80 ±0.1 11.0
18 35 +2.0 7.5 0.80 ±0.1 13.0
18 40 +2.0 7.5 0.80 ±0.1 16.0
20 35 +2.0 10.0 1.0 ±0.1 18.0
20 40 +2.0 10.0 1.0 ±0.1 20.0
22 40 +2.0 10.0 1.0 ±0.1 23.0
25 40 +2.0 12.5 1.0 ±0.1 25.0
B41851, B43851
Standard series 105 °C
Page 4 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Overview of available types B41851
Other voltage and capacitance ratings are available upon request.
VR(V DC) 6.3 10 16 25
Case dimensions d ×l (mm)
CR(µF)
47 5 ×11
68 5 ×11
100 5 ×11 5 ×11 6.3 ×11
220 6.3 ×11 6.3 ×11 8 ×11.5
330 6.3 ×11 8 ×11.5 8 ×11.5 8 ×11.5
10 ×12.5
470 8 ×11.5 8 ×11.5 8 ×11.5 10 ×12.5
680 8 ×11.5 10 ×12.5 10 ×12.5 10 ×16
1000 10 ×12.5 10 ×12.5 10 ×16 10 ×20
1500 10 ×16 10 ×20 10 ×20 12.5 ×20
2200 10 ×20 10 ×20 12.5 ×20 12.5 ×25
3300 10 ×20 12.5 ×25 12.5 ×25
16 ×25
16 ×25
4700 12.5 ×25 16 ×20 16 ×25 16 ×31.5
6800 16 ×25 16 ×31.5 18 ×35
10000 18 ×31.5 18 ×35 20 ×40
B41851
Standard series 105 °C
Page 5 of 42Please read Cautions and warnings and
Important notes at the end of this document.
VR(V DC) 35 50 63 100
Case dimensions d ×l (mm)
CR(µF)
0.10 5 ×11
0.22 5 ×11
0.33 5 ×11
0.47 5 ×11
0.68 5 ×11
1.0 5 ×11 5 ×11
2.2 5 ×11 5 ×11
3.3 5 ×11 5 ×11
4.7 5 ×11 5 ×11
10 5 ×11 5 ×11 6.3 ×11
22 5 ×11 5 ×11 8 ×11.5
33 5 ×11 6.3 ×11 6.3 ×11 8 ×11.5
10 ×12.5
47 5 ×11 6.3 ×11 6.3 ×11 10 ×12.5
68 6.3 ×11 6.3 ×11 8 ×11.5 10 ×16
100 6.3 ×11 8 ×11.5 8 ×11.5 10 ×20
220 8 ×11.5 10 ×12.5 10 ×16 12.5 ×25
330 10 ×12.5 10 ×16 10 ×20 16 ×25
470 10 ×16 10 ×20 12.5 ×20 16 ×31.5
680 10 ×20 12.5 ×20 16 ×20 18 ×40
1000 12.5 ×20 12.5 ×25 16 ×25 18 ×40
1500 16 ×20 16 ×25 18 ×31.5
2200 16 ×25 16 ×31.5
18 ×35
18 ×35
3300 16 ×31.5 18 ×35 20 ×40
4700 18 ×35 20 ×40 25 ×40
6800 18 ×40
B41851
Standard series 105 °C
Page 6 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Overview of available types B43851
Other voltage and capacitance ratings are available upon request.
VR(V DC) 160 200 250 350 400 450
Case dimensions d ×l (mm)
CR(µF)
0.47 6.3 ×11 6.3 ×11
0.68 6.3 ×11 6.3 ×11
1.0 6.3 ×11 6.3 ×11 6.3 ×11 6.3 ×11
2.2 6.3 ×11 6.3 ×11 6.3 ×11 6.3 ×11
8×11.5
8×11.5 8 ×11.5
3.3 6.3 ×11 6.3 ×11 6.3 ×11 8 ×11.5 8 ×11.5 10 ×12.5
4.7 6.3 ×11 6.3 ×11 8 ×11.5 8 ×11.5 10 ×12.5 10 ×12.5
10 8 ×11.5 8 ×11.5 10 ×12.5 10 ×16 10 ×20 10 ×20
22 10 ×12.5
10 ×16
10 ×16 10 ×20 12.5 ×20 12.5 ×25 12.5 ×25
33 10 ×16
10 ×20
10 ×20 12.5 ×20 12.5 ×25 16 ×20 16 ×25
47 10 ×20
12.5 ×20
12.5 ×20 12.5 ×25 16 ×25 16 ×25 16 ×31.5
68 12.5 ×20 12.5 ×25 16 ×25 16 ×31.5 18 ×31.5 18 ×35
100 12.5 ×25
16 ×25
16 ×25 16 ×31.5 18 ×35 18 ×40 20 ×40
220 16 ×31.5
18 ×31.5
18 ×31.5 18 ×40
330 18 ×35 20 ×35 22 ×40
470 20 ×40 22 ×40
680 25 ×40
B43851
Standard series 105 °C
Page 7 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=5×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 6.3 V DC
330 6.3 ×11 1.4 195 275 B41851A2337M***
470 8 ×11.5 1.0 265 370 B41851B2477M***
680 8 ×11.5 0.68 295 413 B41851F2687M***
1000 10 ×12.5 0.46 455 635 B41851A2108M***
1500 10 ×16 0.31 525 735 B41851F2158M***
2200 10 ×20 0.23 710 995 B41851A2228M***
3300 10 ×20 0.16 840 1175 B41851A2338M***
4700 12.5 ×25 0.12 1120 1570 B41851A2478M***
VR= 10 V DC
100 5 ×11 4.0 105 150 B41851A3107M***
220 6.3 ×11 1.8 175 245 B41851A3227M***
330 8 ×11.5 1.2 220 310 B41851B3337M***
470 8 ×11.5 0.85 280 390 B41851A3477M***
680 10 ×12.5 0.59 330 460 B41851A3687M***
1000 10 ×12.5 0.40 460 645 B41851A3108M***
1500 10 ×20 0.27 510 715 B41851A3158M***
2200 10 ×20 0.20 760 1065 B41851A3228M***
3300 12.5 ×25 0.14 1085 1520 B41851A3338M***
4700 16 ×20 0.11 1190 1665 B41851A3478M***
6800 16 ×25 0.08 1575 2205 B41851F3688M***
10000 18 ×31.5 0.07 1820 2250 B41851F3109M***
B41851
Standard series 105 °C
Page 8 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=5×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 16 V DC
100 5 ×11 3.3 115 160 B41851A4107M***
220 6.3 ×11 1.5 190 265 B41851F4227M***
330 8 ×11.5 1.0 265 370 B41851B4337M***
470 8 ×11.5 0.71 315 440 B41851K4477M***
680 10 ×12.5 0.49 390 545 B41851F4687M***
1000 10 ×16 0.33 560 785 B41851A4108M***
1500 10 ×20 0.22 650 910 B41851F4158M***
2200 12.5 ×20 0.17 920 1290 B41851F4228M***
3300 12.5 ×25 0.12 1170 1640 B41851F4338M***
3300 16 ×25 0.12 1260 1765 B41851A4338M***
4700 16 ×25 0.09 1500 2100 B41851A4478M***
6800 16 ×31.5 0.07 1600 2240 B41851F4688M***
10000 18 ×35 0.06 1950 2730 B41851F4109M***
VR= 25 V DC
47 5 ×11 5.6 83 116 B41851A5476M***
68 5 ×11 3.9 90 126 B41851F5686M***
100 6.3 ×11 2.7 140 195 B41851A5107M***
220 8 ×11.5 1.2 240 335 B41851B5227M***
330 8 ×11.5 0.80 310 435 B41851F5337M***
330 10 ×12.5 0.80 320 450 B41851A5337M***
470 10 ×12.5 0.56 380 530 B41851F5477M***
680 10 ×16 0.39 440 615 B41851F5687M***
B41851
Standard series 105 °C
Page 9 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=5×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 25 V DC
1000 10 ×20 0.27 680 950 B41851A5108M***
1500 12.5 ×20 0.18 770 1080 B41851F5158M***
2200 12.5 ×25 0.14 1090 1525 B41851F5228M***
3300 16 ×25 0.10 1400 1960 B41851A5338M***
4700 16 ×31.5 0.08 1700 2380 B41851A5478M***
6800 18 ×35 0.06 1850 2590 B41851F5688M***
10000 20 ×40 0.06 2050 2870 B41851F5109M***
VR= 35 V DC
33 5 ×11 7.0 75 105 B41851A7336M***
47 5 ×11 4.9 93 130 B41851A7476M***
68 6.3 ×11 3.4 110 155 B41851A7686M***
100 6.3 ×11 2.3 150 210 B41851F7107M***
220 8 ×11.5 1.1 270 380 B41851F7227M***
330 10 ×12.5 0.70 350 490 B41851A7337M***
470 10 ×16 0.49 460 645 B41851A7477M***
680 10 ×20 0.34 590 825 B41851A7687M***
1000 12.5 ×20 0.23 810 1135 B41851F7108M***
1500 16 ×20 0.15 980 1370 B41851F7158M***
2200 16 ×25 0.12 1260 1765 B41851F7228M***
3300 16 ×31.5 0.09 1500 2100 B41851F7338M***
4700 18 ×35 0.07 1780 2490 B41851K7478M***
6800 18 ×40 0.06 2000 2800 B41851K7688M***
B41851
Standard series 105 °C
Page 10 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=5×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 50 V DC
1 5 ×11 199 13 18 B41851A6105M***
2.2 5 ×11 90 20 28 B41851A6225M***
3.3 5 ×11 60 25 35 B41851A6335M***
4.7 5 ×11 42 30 42 B41851A6475M***
10 5 ×11 20 46 65 B41851B6106M***
22 5 ×11 9.0 67 94 B41851A6226M***
33 6.3 ×11 6.0 90 126 B41851A6336M***
47 6.3 ×11 4.2 115 160 B41851A6476M***
68 6.3 ×11 2.9 150 210 B41851F6686M***
100 8 ×11.5 2.0 190 265 B41851A6107M***
220 10 ×12.5 0.90 300 420 B41851A6227M***
330 10 ×16 0.60 410 575 B41851A6337M***
470 10 ×20 0.42 540 755 B41851A6477M***
680 12.5 ×20 0.29 700 980 B41851F6687M***
1000 12.5 ×25 0.20 950 1330 B41851F6108M***
1500 16 ×25 0.13 1260 1765 B41851F6158M***
2200 16 ×31.5 0.11 1410 1975 B41851F6228M***
2200 18 ×35 0.11 1540 2155 B41851A6228M***
3300 18 ×35 0.08 1770 2480 B41851K6338M***
4700 20 ×40 0.06 2100 2940 B41851K6478M***
B41851
Standard series 105 °C
Page 11 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=5×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 63 V DC
10 5 ×11 20 46 65 B41851A8106M***
22 5 ×11 9.0 70 100 B41851F8226M***
33 6.3 ×11 6.0 100 140 B41851A8336M***
47 6.3 ×11 4.2 120 170 B41851F8476M***
68 8 ×11.5 2.9 155 220 B41851F8686M***
100 8 ×11.5 2.0 200 280 B41851F8107M***
220 10 ×16 0.90 335 470 B41851A8227M***
330 10 ×20 0.60 510 715 B41851A8337M***
470 12.5 ×20 0.42 640 895 B41851F8477M***
680 16 ×20 0.29 770 1080 B41851F8687M***
1000 16 ×25 0.20 930 1300 B41851F8108M***
1500 18 ×31.5 0.13 1260 1765 B41851F8158M***
2200 18 ×35 0.11 1650 2310 B41851K8228M***
3300 20 ×40 0.08 1950 2730 B41851A8338M***
4700 25 ×40 0.06 2250 3150 B41851F8478M***
B41851
Standard series 105 °C
Page 12 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=5×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 100 V DC
0.1 5 ×11 1658 1.5 2.1 B41851A9104M***
0.22 5 ×11 754 3.4 4.8 B41851A9224M***
0.33 5 ×11 502 5.0 7.0 B41851A9334M***
0.47 5 ×11 353 7.1 10 B41851A9474M***
0.68 5 ×11 244 9.1 13 B41851A9684M***
1 5 ×11 166 15 21 B41851A9105M***
2.2 5 ×11 75 21 30 B41851A9225M***
3.3 5 ×11 50 29 41 B41851A9335M***
4.7 5 ×11 35 32 45 B41851A9475M***
10 6.3 ×11 17 53 74 B41851A9106M***
22 8 ×11.5 7.5 98 137 B41851B9226M***
33 8 ×11.5 5.0 125 175 B41851F9336M***
33 10 ×12.5 5.0 135 190 B41851A9336M***
47 10 ×12.5 3.5 160 225 B41851B9476M***
68 10 ×16 2.4 195 275 B41851A9686M***
100 10 ×20 1.7 245 345 B41851A9107M***
220 12.5 ×25 0.75 435 610 B41851A9227M***
330 16 ×25 0.50 560 785 B41851A9337M***
470 16 ×31.5 0.35 700 980 B41851A9477M***
680 18 ×40 0.24 770 1080 B41851F9687M***
1000 18 ×40 0.17 950 1330 B41851F9108M***
B41851
Standard series 105 °C
Page 13 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see
below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=6.3×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 160 V DC
1 6.3 ×11 186 16 27 B43851A1105M***
2.2 6.3 ×11 85 23 39 B43851A1225M***
3.3 6.3 ×11 56 28 48 B43851A1335M***
4.7 6.3 ×11 40 35 60 B43851F1475M***
10 8 ×11.5 18 56 95 B43851F1106M***
22 10 ×12.5 13 91 155 B43851F1226M***
22 10 ×16 8.4 108 184 B43851A1226M***
33 10 ×16 7.5 125 213 B43851F1336M***
33 10 ×20 5.6 143 243 B43851A1336M***
47 10 ×20 4.9 150 255 B43851K1476M***
47 12.5 ×20 4.5 188 320 B43851F1476M***
68 12.5 ×20 3.0 250 425 B43851K1686M***
100 12.5 ×25 2.3 300 510 B43851F1107M***
100 16 ×25 1.8 332 564 B43851A1107M***
220 16 ×31.5 0.95 532 904 B43851F1227M***
220 18 ×31.5 0.84 560 952 B43851A1227M***
330 18 ×35 0.70 695 1182 B43851F1337M***
470 20 ×40 0.42 910 1547 B43851F1477M***
680 25 ×40 0.34 1000 1700 B43851G1687M***
B43851
Standard series 105 °C
Page 14 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see
below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=6.3×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 200 V DC
1 6.3 ×11 186 16 27 B43851A2105M***
2.2 6.3 ×11 85 23 39 B43851A2225M***
3.3 6.3 ×11 56 28 48 B43851A2335M***
4.7 6.3 ×11 40 35 60 B43851G2475M***
10 8 ×11.5 21 56 95 B43851G2106M***
22 10 ×16 8.4 108 184 B43851K2226M***
33 10 ×20 5.6 144 245 B43851B2336M***
47 12.5 ×20 4.5 190 323 B43851R2476M***
68 12.5 ×25 3.3 245 417 B43851K2686M***
100 16 ×25 1.8 332 564 B43851A2107M***
220 18 ×31.5 0.95 560 952 B43851B2227M***
330 20 ×35 0.65 650 1105 B43851R2337M***
470 22 ×40 0.46 760 1292 B43851R2477M***
VR= 250 V DC
0.47 6.3 ×11 395 11 19 B43851F2474M***
0.68 6.3 ×11 273 13 22 B43851F2684M***
1 6.3 ×11 186 16 27 B43851F2105M***
2.2 6.3 ×11 85 23 39 B43851F2225M***
3.3 6.3 ×11 65 35 60 B43851K2335M***
4.7 8 ×11.5 40 38 65 B43851P2475M***
10 10 ×12.5 23 66 112 B43851K2106M***
22 10 ×20 8.4 120 204 B43851F2226M***
B43851
Standard series 105 °C
Page 15 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see
below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=6.3×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 250 V DC
33 12.5 ×20 5.6 161 274 B43851K2336M***
47 12.5 ×25 4.3 203 345 B43851G2476M***
68 16 ×25 2.7 266 452 B43851F2686M***
100 16 ×31.5 1.8 364 619 B43851K2107M***
220 18 ×40 0.84 476 809 B43851F2227M***
330 22 ×40 0.56 658 1119 B43851F2337M***
VR= 350 V DC
0.47 6.3 ×11 395 10 17 B43851A4474M***
0.68 6.3 ×11 273 12 20 B43851A4684M***
1 6.3 ×11 186 15 26 B43851A4105M***
2.2 6.3 ×11 97 23 39 B43851F4225M***
2.2 8 ×11.5 85 26 44 B43851B4225M***
3.3 8 ×11.5 65 30 51 B43851F4335M***
4.7 8 ×11.5 45 38 65 B43851F4475M***
10 10 ×16 21 70 119 B43851F4106M***
22 12.5 ×20 9.0 140 238 B43851F4226M***
33 12.5 ×25 5.6 168 286 B43851F4336M***
47 16 ×25 4.0 210 357 B43851F4476M***
68 16 ×31.5 3.1 290 493 B43851F4686M***
100 18 ×35 2.3 364 619 B43851F4107M***
B43851
Standard series 105 °C
Page 16 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B43851
CR
120 Hz
20 °C
µF
Case dimensions
d×l
mm
ESRmax
120 Hz
20 °C
IAC,R
120 Hz
105 °C
mA
IAC,max
120 Hz
85 °C
mA
Ordering code
(composition see
below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (from d ×l=10×20 mm to 18 ×40 mm)
002 = for cut leads, bulk (from d ×l=10×12.5 mm to 22 ×40 mm)
003 = for crimped leads, blister (from d ×l=16×20 mm to 20 ×40 mm)
004 = for J leads, blister (from d ×l=10×12.5 mm to 18 ×35 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for d = 8 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm (from d = 5 mm to 6.3 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d ×l=6.3×11 mm to 12.5 ×25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×20 ... 16 ×31.5 mm and
18 ×25 ... 18 ×31.5 mm)
012 = for bent 90°leads, blister (for 16 and 18 mm)
VR= 400 V DC
2.2 8 ×11.5 97 26 44 B43851H9225M***
3.3 8 ×11.5 65 36 61 B43851F9335M***
4.7 10 ×12.5 46 56 95 B43851F9475M***
10 10 ×20 18 80 136 B43851A9106M***
22 12.5 ×25 8.4 140 238 B43851F9226M***
33 16 ×20 5.6 168 286 B43851F9336M***
47 16 ×25 4.0 196 333 B43851F9476M***
68 18 ×31.5 3.3 294 500 B43851A9686M***
100 18 ×40 1.9 310 527 B43851K9107M***
VR= 450 V DC
2.2 8 ×11.5 97 20 34 B43851F5225M***
3.3 10 ×12.5 65 28 48 B43851F5335M***
4.7 10 ×12.5 45 32 54 B43851K5475M***
10 10 ×20 26 56 95 B43851F5106M***
22 12.5 ×25 14 100 170 B43851F5226M***
33 16 ×25 7.6 125 213 B43851F5336M***
47 16 ×31.5 4.8 155 264 B43851F5476M***
68 18 ×35 2.7 193 328 B43851A5686M***
100 20 ×40 1.8 207 352 B43851A5107M***
B43851
Standard series 105 °C
Page 17 of 42Please read Cautions and warnings and
Important notes at the end of this document.
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Useful life
depending on ambient temperature TAunder ripple current operating conditions1)
VR= 6.3 ... 100 V DC
VR= 160 ... 450 V DC
B41851, B43851
Standard series 105 °C
Page 18 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Frequency factor of permissible ripple
current IAC versus frequency f
VR100 V DC
Frequency factor of permissible ripple
current IAC versus frequency f
VR160 V DC
B41851, B43851
Standard series 105 °C
Page 19 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Taping, packing and lead configurations
Taping
Single-ended capacitors are available taped in Ammo pack from diameter 4 to 18 mm as follows:
Lead spacing F = 2.0 mm (d=4 5 mm)
Lead spacing F = 2.5 mm (d=4 6.3 mm)
Lead spacing F = 3.5 mm (d = 8 mm)
Lead spacing F = 5.0 mm (d=4 12.5 mm)
Lead spacing F = 7.5 mm (d = 16 ... 18 mm).
Lead spacing 2.0 mm (d = 4 ... 5 mm)
Last 3 digits of ordering code: 016
Dimensions in mm
d F H W W0W1W2P P0P1I1th D0
4 ... 5 2.0 18.5 18.0 7.0 9.0 3.0 12.7 12.7 5.10 1.0 0.7 1 4.0
+0.8
0.2 ±0.75 ±0.5 min. ±0.5 max. ±1.0 ±0.3 ±0.7 max. ±0.2 ±1.0 ±0.2
B41851, B43851
Standard series 105 °C
Page 20 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Lead spacing 2.5 mm (d = 4 ... 6.3 mm)
Last 3 digits of ordering code: 007
Dimensions in mm
d F H W W0W1W2H0P P0P1I1th D0
4 ... 6.3 2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0
Toler-
rance
+0.8
0.2 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2
Lead spacing 3.5 mm (d = 8 mm)
Last 3 digits of ordering code: 006
Dimensions in mm
d F H W W0W1W2P P0P1I1th D0
8 3.5 18.5 18.0 10 9.0 3.0 12.7 12.7 4.6 1.0 0.7 1.0 4.0
Toler-
ance
+0.8
0.2 ±1.0 ±0.5 min. ±0.5 max. ±1.0 ±0.3 ±0.6 max. ±0.2 max. ±0.2
Leads can also run straight through the taping area. Taping is available up to dimensions
d×l=8×15 mm.
B41851, B43851
Standard series 105 °C
Page 21 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Lead spacing 5.0 mm (d = 4 ... 8 mm)
Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (d = 10 ... 12.5 mm)
Last 3 digits of ordering code: 008
Dimensions in mm
d F H W W0W1W2H0P P0P1I1th D0
4 ...
6.3 5.0 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 3.85 1.0 0.6 1.0 4.0
820.0 10.0 16.0 12.7 12.7 3.85
10 5.0 19.0 18.0 12.5 9.0 1.5 12.7 12.7 3.85 1.0 0.6 1.0 4.0
12.5 19.0 12.5 15.0 15.0 5.0
Toler-
ance
+0.8
0.2 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. +0.3
0.2 max. ±0.2
Taping is available up to dimensions d ×l = 12.5 ×25 mm.
Taping is not available for d ×l=8×20 mm.
B41851, B43851
Standard series 105 °C
Page 22 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Lead spacing 7.5 mm (d = 16 ...18 mm)
Last 3 digits of ordering code: 009
Dimensions in mm
d F H W W0W1W2P P0P1I1tPh D0
16 7.5 18.5 18.0 12.5 9.0 1.5 30.0 15.0 3.75 1.0 0.7 0 0 4.0
18
Toler-
ance ±0.8 0.5
+0.75 ±0.5 min. ±0.5 max. ±1.0 ±0.2 ±0.5 max. ±0.2 ±1.0 ±1.0 ±0.2
Taping is available up to dimensions d ×l=16×31.5 mm and 18 ×31.5 mm.
B41851, B43851
Standard series 105 °C
Page 23 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Cut or kinked leads
Single-ended capacitors are available with cut or kinked leads. Other lead configurations also
available upon request.
Cut leads (Chapter A)
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,
B43088, B43827, B43828.
Last 3 digits of ordering code: 002
Case size d x l (mm) Dimensions
(mm)
a±0.5
4 x 7 1.5
5 x 7 2.0
5 x 11 2.0
6.3 x 7 2.5
6.3 x 11 2.5
8 x 7 3.5
8 x 11.5 3.5
8 x 15 3.5
8 x 20 3.5
10 x 12.5 5.0
10 x 16 5.0
10 x 20 5.0
10 x 25 5.0
Case size d x l (mm) Dimensions
(mm)
a±0.5
12.5 x 16 5.0
12.5 x 20 5.0
12.5 x 25 5.0
12.5 x 31.5 5.0
12.5 x 35.5 5.0
12.5 x 40 5.0
16 x 20 7.5
16 x 25 7.5
16 x 31.5 7.5
16 x 35.5 7.5
16 x 40 7.5
18 x 20 7.5
18 x 25 7.5
18 x 31.5 7.5
18 x 35.5 7.5
18 x 40 7.5
B41851, B43851
Standard series 105 °C
Page 24 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Cut leads (Chapter B)
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Last 3 digits of ordering code: 002
With stand-off rubber seal Case size Dimensions (mm)
d×l (mm) a ±0.5
10 ×12.5 5.0
10 ×16 5.0
10 ×20 5.0
12.5 ×20 5.0
12.5 ×25 5.0
16 ×20 7.5
16 ×25 7.5
16 ×31.5 7.5
16 ×35.5 7.5
18 ×20 7.5
18 ×25 7.5
18 ×31.5 7.5
18 ×35 7.5
18 ×40 7.5
With flat rubber seal
B41851, B43851
Standard series 105 °C
Page 25 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Kinked leads (Chapter A)
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,
B43088, B43827, B43828.
Last 3 digits of ordering code: 001
Case size d x l (mm) Dimensions
(mm)
a±0.5
4 x 7 1.5
5 x 7 2.0
5 x 11 2.0
6.3 x 7 2.5
6.3 x 11 2.5
8 x 7 3.5
8 x 11.5 3.5
8 x 15 3.5
8 x 20 3.5
10 x 12.5 5.0
10 x 16 5.0
10 x 20 5.0
10 x 25 5.0
Case size d x l (mm) Dimensions
(mm)
a±0.5
12.5 x 16 5.0
12.5 x 20 5.0
12.5 x 25 5.0
12.5 x 31.5 5.0
12.5 x 35.5 5.0
12.5 x 40 5.0
16 x 20 7.5
16 x 25 7.5
16 x 31.5 7.5
16 x 35.5 7.5
16 x 40 7.5
18 x 20 7.5
18 x 25 7.5
18 x 31.5 7.5
18 x 35.5 7.5
18 x 40 7.5
B41851, B43851
Standard series 105 °C
Page 26 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Kinked leads (Chapter B)
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Last 3 digits of ordering code: 001
With stand-off rubber seal Case size Dimensions (mm)
d×l (mm) a ±0.5
10 ×20 5.0
12.5 ×20 5.0
12.5 ×25 5.0
16 ×20 7.5
16 ×25 7.5
16 ×31.5 7.5
16 ×35.5 7.5
18 ×20 7.5
18 ×25 7.5
18 ×31.5 7.5
18 ×35 7.5
18 ×40 7.5
With flat rubber seal
B41851, B43851
Standard series 105 °C
Page 27 of 42Please read Cautions and warnings and
Important notes at the end of this document.
PAPR leads (Protection Against Polarity Reversal)
These lead configurations ensure correct placement of the capacitor on the PCB with regard to
polarity. PAPR leads are available for diameters from 10 mm up to 18 mm.
There are three configurations available: Crimped leads, J leads, bent 90°leads
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Crimped leads
Last 3 digits of ordering code: 003
With stand-off rubber seal With flat rubber seal
Suggestion for PCB hole diameter
Case size Dimensions (mm)
d×l (mm) B ±0.2 C ±0.5 D ±0.1 E ±0.1 a ±0.5 b
16 ×20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
16 ×25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
16 ×31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
16 ×35.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
18 ×20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×35 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×40 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
B41851, B43851
Standard series 105 °C
Page 28 of 42Please read Cautions and warnings and
Important notes at the end of this document.
J leads
Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size Dimensions (mm)
d×l (mm) C ±0.5 E ±0.5 J ±0.2 a ±0.5 b
10 ×12.5 3.2 0.7 1.2 5.0 0.6 ±0.05
10 ×16 3.2 0.7 1.2 5.0 0.6 ±0.05
10 ×20 3.2 0.7 1.2 5.0 0.6 ±0.05
12.5 ×20 3.2 0.7 1.2 5.0 0.6 ±0.05
12.5 ×25 3.2 0.7 1.2 5.0 0.6 ±0.05
16 ×20 3.5 0.7 1.6 7.5 0.8 ±0.05
16 ×25 3.5 0.7 1.6 7.5 0.8 ±0.05
16 ×31.5 3.5 0.7 1.6 7.5 0.8 ±0.05
16 ×35.5 3.5 0.7 1.6 7.5 0.8 ±0.05
18 ×20 3.5 0.7 1.6 7.5 0.8 ±0.1
18 ×25 3.5 0.7 1.6 7.5 0.8 ±0.1
18 ×31.5 3.5 0.7 1.6 7.5 0.8 ±0.1
18 ×35 3.5 0.7 1.6 7.5 0.8 ±0.1
B41851, B43851
Standard series 105 °C
Page 29 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Bent 90°leads for horizontal mounting pinning
Last 3 digits of ordering code: 012
Case size Dimensions (mm)
d×l (mm) C ±0.5 E ±0.5 F ±0.5 a ±0.5 b
16 ×20 4.0 4.0 12.0 7.5 0.8 ±0.05
16 ×25 4.0 4.0 12.0 7.5 0.8 ±0.05
16 ×31.5 4.0 4.0 12.0 7.5 0.8 ±0.05
16 ×35.5 4.0 4.0 12.0 7.5 0.8 ±0.05
18 ×20 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×25 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×31.5 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×35 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×40 4.0 4.0 13.0 7.5 0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
B41851, B43851
Standard series 105 °C
Page 30 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Packing units and box dimensions
Ammo pack
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
d×l
Dimensions (mm) Packing
units
mm Amax Bmax Cmax pcs.
4×7 330 50 196 2000
5×7 330 50 226 2000
5×11 330 50 226 2000
6.3 ×7 330 50 286 2000
6.3 ×11 330 50 286 2000
8×7 330 50 246 1000
8×11.5 330 50 246 1000
8×15 330 50 246 500
10 ×12.5 330 50 196 500
10 ×16 330 54 196 500
10 ×20 330 58 196 500
12.5 ×20 341 60 272 500
12.5 ×25 341 65 272 500
16 ×25 320 65 270 300
16 ×31.5 315 65 275 300
18 ×20 315 65 275 250
18 ×25 315 65 275 250
18 ×31.5 315 65 275 250
B41851, B43851
Standard series 105 °C
Page 31 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Ammo pack
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
Case size
d×l
Dimensions (mm) Packing
units
mm Amax Bmax Cmax pcs.
8×11.5 345 55 240 1000
10 ×12.5 345 55 280 750
10 ×16 345 60 200 500
10 ×20 345 60 200 500
12.5 ×20 345 65 280 500
12.5 ×25 345 65 280 500
16 ×20 315 65 275 300
16 ×25 315 65 275 300
16 ×31.5 315 65 275 300
18 ×20 315 65 275 250
18 ×25 315 65 275 250
18 ×31.5 315 65 275 250
B41851, B43851
Standard series 105 °C
Page 32 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Overview of packing units and code numbers for case sizes 4 x 7 ... 16 x 40
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
dxl
mm
Standard,
bulk
pcs.
Taped,
Ammo pack
pcs.
Kinked leads,
bulk
pcs.
Cut leads,
bulk
pcs.
4 x 7 10000 2000 15000 15000
5 x 7 7500 2000 10000 10000
5 x 11 5000 2000 10000 10000
6.3 x 7 5000 2000 10000 10000
6.3 x 11 5000 2000 5000 5000
8 x 7 5000 1000 5000 5000
8 x 11.5 2500 1000 4000 4000
8 x 15 2000 1000 2500 2500
8 x 20 1500 2000 2000
10 x 12.5 2000 500 2500 2500
10 x 16 1500 500 2000 2000
10 x 20 1000 500 1500 1500
10 x 25 1000 500 1250 1250
12.5 x 16 750 500 1000 1000
12.5 x 20 750 500 500 500
12.5 x 25 750 500 500 500
12.5 x 31.5 500 750 750
12.5 x 35.5 500 750 750
12.5 x 40 500 750 750
16 x 20 375 300 500 500
16 x 25 375 300 500 500
16 x 31.5 250 300 375 375
16 x 35.5 250 375 375
16 x 40 250 375 375
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002
006
007
008
009
016
3.5
2.5
5.0
7.5
2.0
8
4 ... 6.3
4 ... 12.5
16 ... 18
4 ... 5
B41851, B43851
Standard series 105 °C
Page 33 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Overview of packing units and code numbers for case sizes 18 x 20 ... 18 x 40
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
dxl
mm
Standard,
bulk
pcs.
Taped,
Ammo pack
pcs.
Kinked leads,
bulk
pcs.
Cut leads,
bulk
pcs.
18 x 20 250 250 100 100
18 x 25 250 250 100 100
18 x 31.5 250 250 100 100
18 x 35.5 250 100 100
18 x 40 250 100 100
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002
009 7.5 16 ... 18
B41851, B43851
Standard series 105 °C
Page 34 of 42Please read Cautions and warnings and
Important notes at the end of this document.
1) Available upon request
Overview of packing units and code numbers for case sizes 8 ×11.5 ... 16 ×35.5
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
PAPR
Case size
d×l
Stan-
dard,
bulk
Taped,
Ammo pack
Kinked
leads,
bulk
Cut
leads,
bulk
Crimped
leads,
blister
J leads,
blister
Bent 90°
leads,
blister
mm pcs. pcs. pcs. pcs. pcs. pcs. pcs.
8×11.5 1000 1000
10 ×12.5 1000 750 1000 675
10 ×16 1000 500 1000 675
10 ×20 500 500 500 500 500
12.5 ×20 350 500 350 350 300 1)
12.5 ×25 250 500 500 500 225 1)
12.5 ×30 200
12.5 ×35 175
12.5 ×40 175
16 ×20 250 300 200 200 200 200 120
16 ×25 250 300 200 200 200 200 120
16 ×31.5 200 300 250 250 344 344 120
16 ×35.5 100 100 100 150 150 150
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002 003 004 012
006
008
009
3.5
5
7.5
8
5...12.5
16...18
B41851, B43851
Standard series 105 °C
Page 35 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Overview of packing units and code numbers for case sizes 18 ×20 ... 18 ×40
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
PAPR
Case size
d×l
Stan-
dard,
bulk
Taped,
Ammo pack
Kinked
leads,
bulk
Cut
leads,
bulk
Crimped
leads,
blister
J leads,
blister
Bent 90°
leads,
blister
mm pcs. pcs. pcs. pcs. pcs. pcs. pcs.
18 ×20 175 250 175 175 200 200 120
18 ×25 150 250 150 150 200 200 120
18 ×31.5 100 250 100 100 150 150 120
18 ×35 100 100 100 150 150 150
18 ×40 125 100 100 120 72
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002 003 004 012
009 7.5 16...18
B41851, B43851
Standard series 105 °C
Page 36 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling aluminum electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
B41851, B43851
Standard series 105 °C
Page 37 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Product safety
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic Safety information Reference
chapter "General
technical information"
Polarity Make sure that polar capacitors are connected
with the right polarity.
1
"Basic construction of
aluminum electrolytic
capacitors"
Reverse voltage Voltages polarity classes should be prevented by
connecting a diode.
3.1.6
"Reverse voltage"
Upper category
temperature
Do not exceed the upper category temperature. 7.2
"Maximum permissible
operating temperature"
Maintenance Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
10
"Maintenance"
Mounting
position of screw-
terminal capacitors
Do not mount the capacitor with the terminals
(safety vent) upside down.
11.1.
"Mounting positions of
capacitors with screw
terminals"
Mounting of
single-ended
capacitors
The internal structure of single-ended capacitors
might be damaged if excessive force is applied to
the lead wires.
Avoid any compressive, tensile or flexural stress.
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
11.4
"Mounting
considerations for
single-ended capacitors"
Robustness of
terminals
The following maximum tightening torques must
not be exceeded when connecting screw
terminals:
M5: 2 Nm
M6: 2.5 Nm
11.3
"Mounting torques"
Soldering Do not exceed the specified time or temperature
limits during soldering.
11.5
"Soldering"
B41851, B43851
Standard series 105 °C
Page 38 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Topic Safety information Reference
chapter "General
technical information"
Soldering,
cleaning agents
Do not allow halogenated hydrocarbons to come
into contact with aluminum electrolytic capacitors.
11.6
"Cleaning agents"
Passive
flammability
Avoid external energy, such as fire or electricity. 8.1
"Passive flammability"
Active
flammability
Avoid overload of the capacitors. 8.2
"Active flammability"
Reference
chapter "Capacitors with
screw terminals"
Breakdown strength
of insulating
sleeves
Do not damage the insulating sleeve, especially
when ring clips are used for mounting.
"Screw terminals
accessories"
B41851, B43851
Standard series 105 °C
Page 39 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Symbols and terms
Symbol English German
C Capacitance Kapazität
CRRated capacitance Nennkapazität
CSSeries capacitance Serienkapazität
CS,T Series capacitance at temperature T Serienkapazität bei Temperatur T
CfCapacitance at frequency f Kapazität bei Frequenz f
d Case diameter, nominal dimension Gehäusedurchmesser, Nennmaß
dmax Maximum case diameter Maximaler Gehäusedurchmesser
ESL Self-inductance Eigeninduktivität
ESR Equivalent series resistance Ersatzserienwiderstand
ESRfEquivalent series resistance at
frequency f
Ersatzserienwiderstand bei Frequenz f
ESRTEquivalent series resistance at
temperature T
Ersatzserienwiderstand bei Temperatur T
f Frequency Frequenz
I Current Strom
IAC Alternating current (ripple current) Wechselstrom
IAC,rms Root-mean-square value of alternating
current
Wechselstrom, Effektivwert
IAC,f Ripple current at frequency f Wechselstrom bei Frequenz f
IAC,max Maximum permissible ripple current Maximal zulässiger Wechselstrom
IAC,R Rated ripple current Nennwechselstrom
IAC,R (B) Rated ripple current for base cooling Nennwechselstromstrom für Bodenkühlung
Ileak Leakage current Reststrom
Ileak,op Operating leakage current Betriebsreststrom
l Case length, nominal dimension Gehäuselänge, Nennmaß
lmax Maximum case length (without
terminals and mounting stud)
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
R Resistance Widerstand
Rins Insulation resistance Isolationswiderstand
Rsymm Balancing resistance Symmetrierwiderstand
T Temperature Temperatur
T Temperature difference Temperaturdifferenz
TAAmbient temperature Umgebungstemperatur
TCCase temperature Gehäusetemperatur
TBCapacitor base temperature Temperatur des Becherbodens
t Time Zeit
t Period Zeitraum
tbService life (operating hours) Brauchbarkeitsdauer (Betriebszeit)
B41851, B43851
Standard series 105 °C
Page 40 of 42Please read Cautions and warnings and
Important notes at the end of this document.
Symbol English German
V Voltage Spannung
VFForming voltage Formierspannung
Vop Operating voltage Betriebsspannung
VRRated voltage, DC voltage Nennspannung, Gleichspannung
VSSurge voltage Spitzenspannung
XCCapacitive reactance Kapazitiver Blindwiderstand
XLInductive reactance Induktiver Blindwiderstand
Z Impedance Scheinwiderstand
ZTImpedance at temperature T Scheinwiderstand bei Temperatur T
tan δDissipation factor Verlustfaktor
λFailure rate Ausfallrate
ε0Absolute permittivity Elektrische Feldkonstante
εrRelative permittivity Dielektrizitätszahl
ωAngular velocity; 2 πf Kreisfrequenz; 2 πf
Note
All dimensions are given in mm.
B41851, B43851
Standard series 105 °C
Page 41 of 42Please read Cautions and warnings and
Important notes at the end of this document.
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties de-
scribed in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Ma-
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-
tailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the fore-
going for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the "General Terms of Delivery for Products and Services in the Electrical In-
dustry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC,
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trade-
marks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
Important notes
Page 42 of 42