MVP Series 400 - 1000 Watts SPECIAL FEATURES * Current share on all main outputs with ratings of 10 A or greater * Remote sense on all outputs with ratings greater than 2 A * Overload protection on all outputs * Voltage adjustment on all outputs * Margining on all single output modules * Input-OK-signal and status indicator LED * Global DC OK signal and status indicator LED * Global and individual module inhibits/enable * 1 year warranty * Forced air cooling, field replaceable fan * Isolated 5 V bias voltage * Power factor correction * IEC EN61000-3-2 harmonic distortion compliance * CISPR 22, EN55022 Curve B conducted / radiated EMI * IEC 801 immunity standards * European CE Mark requirements * Optional VME timing and system DC OK module * Low leakage option for medical applications MP4.................................................................400 W total MP6.................................................................600 W total E N V I R O N M E N TA L Operating temperature: -20C to 50C (start @ 0C) (derate each output linearly to 50% at 70C) (-20C to 40C max. with rear air option) Shock/Vibration: Mil-Hdbk 810E Humidity: 95% non-condensing Storage temperature: -40C to +85C Temperature coefficient: 0.02% per C Cooling: Internal DC fan (Field replaceable) (P/N 73-688-0001) MP8.................................................................800 W total SAFETY UL CSA IEC VDE BABT CB CE UL1950 E133211 CSA22.2 No. 234 Level 5 LR53982 IEC950, Class 1 EN60950 11774-3336-xxxx Compliance to EN 60950, BS 7002 Certificate and report Mark MP1.................................................................1000 W total 80 USA: 1-888-41-ASTEC Europe (UK): 01384-842211 Asia (HK): 852-2437-9662 ASTEC ASIA 6F., China Dyeing Works Building 382-392 Castle Peak Road Tsuen Wan, N.T., Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 E L E C T R I C A L S P E C I F I C AT I O N S Input ASTEC EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 01384-842211 Facsimile: 01384-843355 ASTEC AMERICA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Output Input voltage...........................85-264 VAC 120-350 VDC Frequency ..............................47-440 Hz Inrush current.........................40 A peak max. Efficiency................................70-80% typ. @ full case load Power factor ...........................0.99 typ. meets EN61000-3-2 Turn-on time ...........................AC on 1.5 sec typ., Inhibit / Enable 150 ms typ. EMI filter standard ..................CISPR 22 EN55022 Level "B" EMI filter (low leakage option)...CISPR 22 EN55022 Level "A" Leakage current standard ......2.0 mA max. @ 240 VAC Leakage current (low leakage option)...............300 A max. @ 240 VAC Radiated EMI .........................CISPR 22 EN55022 Level "B" Holdover storage....................20 ms minimum (independent of input VAC) AC OK....................................>5 ms early warning min. before outputs loose regulation Full cycle ride thru (50 Hz) Harmonic distortion ................Meets EN61000-3-2 Isolation..................................Meets EN60950 Global Inhibit/Enable ..............TTL, Logic "1" and Logic "0" Input fuse (internal) ................MP4: 10 A MP6: 15 A MP8: 20 A MP1: 20 A Warranty.................................1 year Adjustment range ...................10% min. all outputs Margining ...............................4-6% nom.1 Overall reg..............................0.4% or 20 mV max. (36 W modules 4% max.) Ripple.....................................RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater Bandwidth limited to 20 MHz Dynamic response .................<2% or 100 mV, with 25% load step. Recovery time ........................To within 1% in <300 sec. Overcurrent protection ...........Single, main of dual output module 105-120% of rated output current. Aux output of dual output module 105-140% of rated output current. Triple output module Internally protected Short circuit protection ...........Protected for continuous short circuit. Recovery is automatic upon removal of short Overvoltage protection ...........Single output modules (measured at sense 2-5.5 V 122-134% connection) 6-60 V 110-120% Dual output module 2-6 V 122-134% 8-28 V 110-120% Triple output module. No overvoltage protection provided. Recycle the AC input voltage to reset OVP circuit Reverse voltage protection ...............................100% of rated output current Thermal protection .................All outputs disabled when internal temp exceeds safe operating range. >5 ms warning (AC OK signal) before shutdown Remote sense ........................Up to 0.5 V total drop Single wire parallel.................Current share to within 2% of total rated current 2 DC OK....................................-2% to -8% of nominal for any monitored output 2 Minimum load.........................Not required on single or triple output modules. 10% required on main of dual output modules 3 (Consult factory if pre-loaded required) Housekeeping Bias voltage ...........................5 VDC @250 mA max. present whenever AC input is applied Module inhibit.........................TTL, isolated, singles and dual (both outputs) only Switching frequency...............250 kHz Output/Output isolation ..........>1 Megohm Notes: 1 Single output modules only. 2 Single and main of dual output modules only. 3 Contact factory for optional preload if required. Power Fax: 760-930-0881 Doc No: 1058 * REV 1.6.99 81 Common Examples and Specifications MP - Case Size (inches): 4 = 2.5 x 5 x 10, 5 available slots, 400 W max. 6 = 2.5 x 5 x 11, 5 available slots, 600 W max. 8 = 2.5 x 7 x 10, 6 available slots, 800 W max. 1 = 2.5 x 8 x 11, 7 available slots, 1000 W max. Slot #4 Slot #3 Slot #2 Slot #1 - Option Code: 0 = no options 1 = rear air exhaust 3 = global enable 5 = option package (options 1 & 3) M =low leakage N = low leakage plus option 1 P = low leakage plus option 3 R = low leakage plus option 5 - - 2 or 3 Digit Code See Output Currents Next Page Slot #5 - (MP8 & MP1 Only) Slot #6 (MP1 Only) Slot #7 - - -XXX Use Only for Modified Standard Contact Astec. Use " -- " for Standard Remote Sense Use " / " After any module using Remote Sense with o-ring diode (redundancy) Notes: 1 Omit digits that do not apply. 2 Specify modules from lowest number of outputs to highest.(Single/Dual/Triple) 3 If number of outputs are equal, specify modules from highest to lowest power increments. If power increments are equal, specify in decending alphabetical order (1A, B, C...). 4 Always start with Slot 1. 5 All MVP model configurations created using this selection guide are standard MVP products with standard availability and lead times. Parallel Code: MP4 & MP6 available slots MP8 available slots MP1 available slots Standard Parallel Codes* 0 = no parallel 1=1&2 Ordering Example: 2.5" x 5" x 11" (5 slots available) M P 6 - Slot 5 Output 5: 12 V @ 1 A Output 6: 12 V @ 1 A Output 7: 5 V @ 2 A Slot 3 Output 2: 12 V @ 17 A 7 6 5 4 3 2 1 2=2&3 3=3&4 4=4&5 2 F / 1 L - 4 L E - L L E - 0 M 5=3&4&5 6=5&6 Slots 1 & 2 Slot 4 Output 1: 5.2 V @ 60 A Output 3: 12 V @ 10 A Output 4: 5 V @ 10 A 7=4&5&6 Low Leakage 8=6&7 No Paralleling 9 = 3 & 4, 6 & 7 *For custom parallel configurations, contact Astec. COMMON EXAMPLES OF MODEL NUMBERS SINGLE OUTPUTS Total Power Output (Volts/Amps) Size (inches) Model Number 360 W 400 W 600 W 600 W 600 W 800 W 800 W 1000 W 2 / 180 5 / 80 2 / 275 5 / 120 48 / 12.5 5 / 160 48 / 16.6 5 / 200 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 8 x 11 2.5 x 5 x 11 2.5 x 5 x 11 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 8 x 11 MP4-3A-2A-30 MP4-3E-00 MP6-3A-3A-1A-90 MP6-3E-00 MP6-3W-00 MP8-3E-2E-30 MP8-3W-1W-30 MP1-3E-3E-30 Slot 1 MULTIPLE OUTPUTS 82 Total Power Output 1 (Volts/Amps) Output 2 (Volts/Amps) Output 3 (Volts/Amps) Output 4 (Volts/Amps) Output 5 (Volts/Amps) Output 6 (Volts/Amps) Size (inches) Model Number 400 W 400 W 400 W 400 W 600 W 600 W 600 W 800 W 800 W 800 W 800 W 1000 W 5 / 60 24 / 15 5 / 60 5 / 35 3 / 60 5 / 120 12 / 30 36 / 16.6 5 / 120 15 / 20 2 / 180 3.3 / 120 3.3 / 35 12 / 17 12 / 17 12 / 10 5 / 60 12 / 17 5 / 35 24 / 4 3.3 / 35 5 / 35 5 / 60 5 / 120 12 / 1 5 / 35 12 / 10 3.3 / 10 12 / 10 12 / 10 -- 5 / 10 12 / 17 15 / 14 -- -- 12 / 1 -- 5 / 10 12 / 1 12 / 4 5 / 10 -- 12 / 10 12 / 10 24 / 8.5 -- -- 12 / 1 -- -- 12 / 1 -- -- -- 12 / 4 12 / 4 15 / 8 -- -- -- -- -- 5/2 -- -- -- -- -- 5 / 10 -- -- 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 5 x 11 2.5 x 5 x 11 2.5 x 5 x 11 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 8 x 11 MP4-2E-1D-LLL-00 MP4-2Q-1L-1E-00 MP4-2E-1L-4LE-00 MP4-1E-4LD-LLE-00 MP6-2C-2E-4LL-00 MP6-3E-1L-4LE-00 MP6-2L-1E-00 MP8-3U-4QE-4LL-00 MP8-3E-1D-1L-4LL-00 MP8-2N-1E-1N-1Q-4NE-00 MP8-3A-2A-2E-30 MP1-3D-3E-00 USA: 1-888-41-ASTEC Europe (UK): 01384-842211 Asia (HK): 852-2437-9662 ASTEC ASIA 6F., China Dyeing Works Building 382-392 Castle Peak Road Tsuen Wan, N.T., Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 ASTEC EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 01384-842211 Facsimile: 01384-843355 ASTEC AMERICA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 OUTPUT CURRENTS Voltage Voltage Code 2V 2.2 V 3V 3.3 V 5V 5.2 V 5.5 V 6.0 V 8.0 V 10 V 11 V 12V 14 V 15 V 18 V 20 V 24 V 28 V 30 V 33 V 36 V 42 V 48 V 54 V 60 V Non-std 2.4V - 27V 3.6V - 4.5V 6.6V - 7.2V 8.8V - 9.0V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Notes: 1 Takes up one slot. 2 Takes up two slots. 3 Takes up three slots. Single Output Module Code Dual Output Triple Output 1 2 3 V1 V2 V1 V2 V3 35A 35 A 35A 35 A 35A 35 A 34 A 23 A 20 A 18 A 17 A 17A 12.5 A 14 A 11 A 10.5 A 8.5 A 6.7 A 6.5 A 6.2 A 5.8 A 4.2 A 4.0 A 3.7 A 3.5 A 60 A 60 A 60 A 60 A 60 A 60 A 58 A 42 A 36 A 32 A 31 A 30 A 21 A 20 A 19 A 18 A 15 A 12.8 A 12 A 10.9 A 10 A 7.5 A 7.5 A 6.0 A 6.0 A 120 A 120 A 120 A 120 A 120 A 115 A 109 A 78 A 68 A 60 A 54.5 A 50 A 40.5 A 39 A 33.3 A 30 A 23.5 A 21.4 A 20 A 18.2 A 16.6 A 12.5 A 12.5 A 11 A 10 A -- -- -- -- 10 A -- -- -- -- -- -- 10 A 9A 8A -- -- 4A 3A -- -- -- -- -- -- -- 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A -- -- -- 4A 4A 4A -- -- 2A 2A 1.5 A 1.5 A 1.5 A -- -- -- -- -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A 0.5 A 0.5 A 0.5 A 0.5 A -- -- -- -- -- -- -- 2A 2A 2A 2A 2A 2A 2A 2A 1A 1A 1A 1A 1A 1A 0.5 A 0.5 A 0.5 A 0.5 A -- -- -- -- -- -- -- 135 35 20 18 60 60 36 32 120 120 68 60 -- -- 10 10 10 10 4 4 -- -- -- -- -- -- -- -- 2 2 1 1 Single Output Example Dual Output Example 1 Triple Output Example 1 5 V @ 60 A 12 V @ 10 A; 5 V @ 10 A 12 V @ 1 A; 20 V @ 0.5 A; 5V@2A Module Code Voltage Code Module Code (always 4) 2 E Voltage Code L P E 4 L E Notes: 1. Total Loading not to exceed 144 W. Voltage Code2 Notes: 1. Total Loading not to exceed 36 W. 2. No Module Code required. PFC INPUT DC/DC CONV ERTER OU TPU T MODU LES J1 CONTROL CONNECTOR CONTROL SIGNAL INFORMATION, J1 CONTROL CONNECTOR Pin No. J1-1 J1-2 J1-3 J1-4 J1-5 J1-6 J1-7 J1-8 J1-9 J1-10 Function Input AC OK - "Emitter" Input AC OK - "Collector" Global DC OK - "Emitter" Global DC OK - "Collector" Spare Global Inhibit/Optional Enable Logic "0" Global Inhibit/Optional Enable Logic "1" Global Inhibit/Optional Enable Return SELV 5V Housekeeping SELV 5V Housekeeping Return Pin No. 1 2 3 4 5 6 7 8 9 10 Function + Remote Sense Remote Margin / V. Program Margin High - Remote Sense / Margin Low Spare Module, Isolated Inhibit Module Inhibit return Current Share (SWP) + Remote Sense V2 - Remote Sense V2 Power Fax: 760-930-0881 single or dual o/p main single o/p single o/p single or dual o/p main single or dual o/p single or dual o/p single or dual o/p main dual o/p, single is spare dual o/p, single is spare Doc No: 1058 * REV 1.6.99 83 MVP Series 400 - 1000 Watts D R AW I N G S * M V P S E R I E S M P 4 ( 4 0 0 W AT T S M A X ) A N D M P 6 ( 6 0 0 W AT T S M A X ) 5-Inch Case Size: MP4: 2.5" x 5" x 10" (63.5mm x 127mm x 254mm) 5-Inch Case Size: MP6: 2.5" x 5" x 11" (63.5mm x 127mm x 279.4mm) Weight: MP4 Case: 2.6 lbs. * MP6 Case: 3.2 lbs. * 36 W Triple: 0.5 lb. 210 W Single: 0.6 lb. * 360 W Single 1.0 lb. * 600 W Single: 2.0 lbs. 144 W Dual: 0.6 lb. NOTES 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375" centers). Max torque: 6 in-lbs. (0.67 N-m). 2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins, Astec part #70-841-004. 3. Chassis material: aluminum with chemical film coating. (Conductive) 4. All dimensions are in millimeters and inches and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150" (3.8mm). Max. torque: 5in-lbs. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Triple O/P module is .045" square pins on .156" centers. (Mates with Molex 09-50-8063 or equivalent.) 84 USA: 1-888-41-ASTEC Europe (UK): 01384-842211 Asia (HK): 852-2437-9662 ASTEC ASIA 6F., China Dyeing Works Building 382-392 Castle Peak Road Tsuen Wan, N.T., Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 ASTEC EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 01384-842211 Facsimile: 01384-843355 ASTEC AMERICA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 D R AW I N G S * M V P S E R I E S M P 8 ( 8 0 0 W AT T S M A X ) 7-Inch Case Size: MP8: 2.5" x 7" x 10" (63.5mm x 177.8mm x 254mm) Weight: MP8 Case: 4.1 lbs. * 36 W Triple: 0.5 lb. * 210 W Single: 0.6 lb. * 360 W Single: 1.0 lb. * 600 W Single: 2.0 lbs. 144 W Dual: 0.6 lb. NOTES 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375" centers). Max torque: 6 in-lbs. (0.67 N-m). 2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins, Astec part #70-841-004. 3. Chassis material: aluminum with chemical film coating. (Conductive) 4. All dimensions are in millimeters and inches and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150" (3.8mm). Max. torque: 5in-lbs. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Triple O/P module is .045" square pins on .156 centers. (Mates with Molex 09-50-8063 or equivalent.) Power Fax: 760-930-0881 Doc No: 1058 * REV 1.5.99 85 MVP Series 400 - 1000 Watts D R AW I N G S * M V P S E R I E S M P 1 ( 1 00 0 W AT T S M A X ) 8-Inch Case Size: MP1: 2.5" x 8" x 11" (63.5mm x 203.2mm x 279.4mm) Weight: MP1 Case: 5.0 lbs. * 36 W Triple: 0.5 lbs. * 210 W Single: 0.6 lbs. * 360 W Single: 1.0 lb. * 600 W Single: 2.0 lbs. 144 W Dual: 0.6 lb. NOTES 1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375" centers). Max torque: 6 in-lbs (0.67 N-m). 2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins, Astec part #70-841-004. 3. Chassis material: aluminum with chemical film coating. (Conductive) 4. All dimensions are in millimeters and inches and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150" (3.8mm). Max. torque: 5in-lbs. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Triple O/P module is .045" square pins on .156 centers. (Mates with Molex 09-50-8063 or equivalent.) 85a USA: 1-888-41-ASTEC Europe (UK): 01384-842211 Asia (HK): 852-2437-9662 ASTEC ASIA 6F., China Dyeing Works Building 382-392 Castle Peak Road Tsuen Wan, N.T., Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 ASTEC EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 01384-842211 Facsimile: 01384-843355 ASTEC AMERICA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 D R AW I N G S * M V P S E R I E S M P 1 ( 1 00 0 W AT T S M A X ) Power Fax: 760-930-0881 Doc No: 1058 * Rev 1.6.99 85b