Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. * 1395 S. Marietta Parkway * Building 800 * Marietta, GA 30067 Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com Introduction STEGO develops innovative products that heat, cool, ventilate, illuminate, and control temperature and humidity for enclosed electronic control systems. STEGO products are reliable, simple, high quality and cost effective. We strive to solve electronic control packaging problems for our customers. From our manufacturing plants in Brazil, France, Germany and the United States, and sales offices in the Czech Republic, Italy, the Netherlands, Poland, Spain, Sweden and the UK, we successfully serve customers in over 52 countries around the world. STEGO offers a wide range of products in various sizes and specifications to meet almost any need, and the majority conform to UL and CE standards. PRODUCTS: * * * * * * PTC based enclosure heaters Fan heaters with PTC and resistance heating elements Temperature and humidity controls Explosion-proof heaters and thermostats for hazardous areas Filter fans and exhaust filters Enclosure lights and other accessories With this broad range of products offered, STEGO is assisting customers in a variety of industries with their applications. INDUSTRIES: * * * * * * * Electrical and electronic control systems Telecommunications systems Traffic control systems Parking control systems Ticket dispensing machines Automatic Teller Machines (ATMs) Power generation including Wind and Solar STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FT 011 Tamperproof Thermostat Compact design Fixed set points Color coded modules Tamperproof (Pre-set) Thermostat FTO 011 NC / opens on temperature rise (red module housing) - for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. Tamperproof (Pre-set) Thermostat FTS 011 NO / closes on temperature rise (blue module housing) - for regulating filter fans, heat exchangers, cooling devices or for switching signal devices when temperature limit has been exceeded. Regulating DIN rail mountable 1.3" (33 mm) | Technical Data 1.3" (33 mm) Sensor element thermostatic bimetal Contact type snap-action contact Service life > 100,000 cycles Max. switching capacity 10 A resistive / 2 A inductive @ AC 120 V 5 A resistive / 1.6 A inductive @ AC 250 V 1 2 AC 16 A for 10 sec. Connection 2-pole term. for AWG 14 max. (2.5 mm), torque 0.8 Nm max. Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating temperature -40 to +176 F (-40 to +80 C) Storage temperature -49 to +176 F (-45 to +80 C) Dimensions 1.85 x 1.3 x 1.3" (47 x 33 x 33 mm) Weight approx. 0.8 oz. (23 g) Protection type IP20 Approvals UL File No. E164102, VDE Heater NC (red) NO (blue) FTO 011 Thermostat FTS 011 Thermostat e.g. Fan FTS 011 Thermostat e.g. Signal Device Wiring examples Part No. Contact Switch-off temperature Switch-on temperature 01160.0-00 NC - open on rise 59 F / 15 C ( 9 F / 5 K tolerance) 41 F / 5 C ( 9 F / 5 K tolerance) 01160.0-01 NC - open on rise 77 F / 25 C ( 9 F / 5 K tolerance) 59 F / 15 C ( 9 F / 5 K tolerance) Switch-on temperature Switch-off temperature 01161.0-00 NO - close on rise 122 F / 50 C ( 11 F / 6 K tolerance) 104 F / 40 C ( 12.6 F / 7 K tolerance) 01161.0-01 NO - close on rise 140 F / 60 C ( 11 F / 6 K tolerance) 122 F / 50 C ( 12.6 F / 7 K tolerance) 01161.0-02 NO - close on rise 95 F / 35 C ( 11 F / 6 K tolerance) 77 F / 25 C ( 12.6 F / 7 K tolerance) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FT011/11-12/US 1.85" (47 mm) DC 30 W Max. inrush current KT 011 Small Thermostat Compact design Wide adjustment range Color coded temperature dials Thermostat NC (normally closed) Thermostat opens on temperature rise - for regulating heaters or for switching signal devices. Comes with red temperature dial. Thermostat NO (normally open) Thermostat closes on temperature rise - for regulating filter fans and heat exchangers or for switching signal devices. Comes with blue temperature dial. Regulating DIN rail mountable | 1.7" (43 mm) Technical Data Switching difference 12.6 F 7 F tolerance (7 K 4 K) Sensor element thermostatic bimetal Contact type snap-action contact Service life > 100,000 cycles Max. switching capacity 15 A resistive / 2 A inductive @ AC 120 V 10 A resistive / 2 A inductive @ AC 250 V DC 30 W Max. inrush current AC 16 A for 10 sec. Connection 2-pole terminal, clamping torque 0.5 Nm max.: 1.3" (33 mm) solid wire - AWG 14 max. (2.5 mm) 2.4" (60 mm) stranded wire (with wire end ferrule) - AWG 16 (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 (or for Exhaust Filter EF 118 Series) Mounting position vertical Operating / Storage temperature -49 to +176 F (-45 to +80 C) Dimensions 2.4 x 1.3 x 1.7" (60 x 33 x 43 mm) Weight approx. 1.4 oz. (40 g) Protection type IP20 KT 011 Thermostat KT 011 Thermostat NO (blue) e.g. Fan KT 011 Thermostat e.g. Signal Device Wiring examples Setting range Part No. (NC) Part No. (NO) Approvals +32 to +140 F 01140.9-00 01141.9-00 UL File No. E164102, CSA, VDE 0 to +60 C 01146.9-00 01147.9-00 UL File No. E164102, CSA, VDE -10 to +50 C 01142.0-00 N/A UL File No. E164102, CSA, VDE +10 to +70 C N/A 01149.9-00 UL File No. E164102, CSA, VDE -15 to +45 C 01157.0-00 01156.0-00 UL File No. E164102, CSA, VDE +20 to +80 C 01159.0-00 01158.0-00 UL File No. E164102, CSA, VDE Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com KT011/11-12/US NC (red) Heater ST 011 Compact Thumbwheel Thermostat Adjustable thumbwheel setting Compact design Small hysteresis High switching capacity The ST 011 thermostat is an SPST regulator with a small hysteresis. The housing design ensures optimized air circulation around the sensor element. STO 011: NC / opens on temperature rise (red thumbwheel) - for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. Convenient minimum setpoint symbol on the NC thermostat to assure enclosure temperature remains above freezing Regulating DIN rail mountable STS 011: NO / closes on temperature rise (blue thumbwheel) - for regulating filter fans, heat exchangers, cooling devices or for switching signal devices when temperature limit has been exceeded. | Technical Data Switching difference 7 F (4 K) 5.4 F (3 K) tolerance Sensor element thermostatic bimetal Contact type snap-action contact Service life > 100,000 cycles Max. switching capacity 15 A resistive / 2 A inductive @ AC 120 V 10 A resistive / 2 A inductive @ AC 250 V DC 30 W (DC 24-72 V) Max. inrush current AC 16 A for 10 sec. Connection 2-pole terminal for AWG 14 max. (2.5 mm), torque 1 Nm max. Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +176 F (-45 to +80 C) Max. storage humidity 90 %RH (non-condensing) Dimensions 2.76 x 1.3 x 1.65" (70 x 33 x 42 mm) Weight approx. 1.8 oz. (50 g) Protection type IP20 ST 011 Thermostat ST 011 Thermostat e.g. Filter Fan ST 011 Thermostat e.g. Signal Device NO (blue) Enclosure heater Wiring example Filter fan, cooling equipment, signal device Part No. (NC) 01115.9-00 01115.0-00 Part No. (NO) 01116.9-00 01116.0-00 Setting range 32 to 140 F 0 to 60 C Approvals UL File No. E164102, VDE UL File No. E164102, VDE Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com ST011/11-12/US NC (red) Heater FTD 011 Tamperproof Dual Thermostat NC / NO or NO / NO in one unit Fixed set points Color coded modules DIN rail mountable Tamperproof (Pre-set) Thermostat - NC Opens on temperature rise (red module housing) - for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. Regulating Two thermostats in one housing: Tamperproof (Pre-set) Thermostat - NO Closes on temperature rise (blue module housing) - for regulating filter fans, heat exchangers, cooling devices or for switching signal devices when temperature limit has been exceeded. Heaters and cooling equipment can be switched independently from each other with a temperature offset as opposed to the usual SPDT/change-over contact. 1.3" (33 mm) | Technical Data 2.5" (63 mm) Sensor element thermostatic bimetal Contact type snap-action contact Service life > 100,000 cycles Max. switching capacity 10 A resistive / 2 A inductive @ AC 120 V 1.85" (47 mm) 5 A resistive / 1.6 A inductive @ AC 250 V Heater DC 30 W e.g. Fan FTD 011 Thermostat Max. inrush current AC 16 A for 10 sec. Connection 4-pole term. for AWG 14 max. (2.5 mm), torque 0.8 Nm max. Housing plastic according to UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating temperature -40 to +176 F (-40 to +80 C) Storage temperature -49 to +176 F (-45 to +80 C) Dimensions 1.85 x 2.5 x 1.3" (47 x 63 x 33 mm) Weight approx. 1.41 oz. (40 g) Protection type IP20 Approvals UL File No. E164102, VDE Wiring examples NC - open on rise NO - close on rise Switch-off temperature Switch-on temperature 01163.0-00 59 F / 15 C ( 9 F / 5 K tolerance) 41 F / 5 C ( 9 F / 5 K tolerance) 122 F / 50 C ( 11 F / 6 K tolerance) 104 F / 40 C ( 12.6 F / 7 K tolerance) 01163.0-01 77 F / 25 C ( 9 F / 5 K tolerance) 59 F / 15 C ( 9 F / 5 K tolerance) 140 F / 60 C ( 11 F / 6 K tolerance) 122 F / 50 C ( 12.6 F / 7 K tolerance) 01163.0-02 59 F / 15 C ( 9 F / 5 K tolerance) 41 F / 5 C ( 9 F / 5 K tolerance) 01163.0-03 77 F / 25 C ( 9 F / 5 K tolerance) 59 F / 15 C ( 9 F / 5 K tolerance) Part No. 01164.0-00 NO - close on rise Switch-on temperature Switch-off temperature Switch-on temperature 95 F / 35 C ( 11 F / 6 K tolerance) Switch-off temperature 77 F / 25 C ( 12.6 F / 7 K tolerance) 122 F / 50 C ( 11 F / 6 K tolerance) 104 F / 40 C ( 12.6 F / 7 K tolerance) NO - close on rise Switch-on temperature Switch-off temperature 122 F / 50 C ( 11 F / 6 K tolerance) 104 F / 40 C ( 12.6 F / 7 K tolerance) 140 F / 60 C ( 11 F / 6 K tolerance) 122 F / 50 C ( 12.6 F / 7 K tolerance) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FTD011/11-12/US Part No. ZR 011 Dual Thermostat NC / NO or NO / NO in one unit Separate adjustable temperatures Color coded temperature dials The ZR 011 houses two separate thermostats, allowing the independent control of heating and cooling or other equipment. Thermostat NC (normally closed): Thermostat opens at temperature rise - for regulating heaters or for switching signal devices. Comes with red temperature dial. Regulating DIN rail mountable Thermostat NO (normally open): Thermostat closes at temperature rise - for regulating filter fans and heat exchangers or for switching signal devices. Comes with blue temperature dial. | Technical Data Switching difference 12.6 F 7 F tolerance (7 K 4 K) Sensor element thermostatic bimetal Contact type snap-action contact Service life > 100,000 cycles Max. switching capacity NC: 10 A resistive / 2 A inductive at AC 250 V NO: 5 A resistive / 2 A inductive @ AC 250 V 15 A resistive / 2 A inductive @ AC 120 V DC 30 W Max. inrush current AC 16 A for 10 sec. Connection 4-pole terminal, clamping torque 0.5 Nm max.: solid wire - AWG 14 max. (2.5 mm) stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +176 F (-45 to +80 C) Dimensions 2.6 x 2.0 x 1.8" (67 x 50 x 46 mm) Weight approx. 3.2 oz. (90 g) Protection type IP20 Approvals UL File No. E164102, CSA, VDE Enclosure heater Filter fan, cooling equipment, signal device Setting Range Setting Range NC - open on rise 0 to +60 C NO - close on rise 0 to +60 C 01172.0-01 NC - open on rise +32 to +140 F NO - close on rise +32 to +140 F 01175.0-00 NC - open on rise -10 to +50 C NO - close on rise +20 to +80 C 01175.0-01 NC - open on rise 14 to +122 F NO - close on rise +68 to +176 F 01176.0-00 NO - close on rise 0 to +60 C NO - close on rise 0 to +60 C 01176.0-01 NO - close on rise +32 to +140 F NO - close on rise +32 to +140 F Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com ZR011//11-12/US Part No. 01172.0-00 FZK 011 Mechanical Thermostat Wide adjustment range High switching capacity SPDT (change-over) contact Very low hysteresis option The FZK 011 mechanical thermostat is used for controlling heating and cooling equipment, filter fans or signal devices where a higher degree of sensing accuracy is required. An integrated resistor (RF) can be connected to improve the switch temperature difference (see Option note). The thermostat registers the surrounding air and can switch both inductive and resistive loads via snap-action contact. Regulating DIN rail mountable | Technical Data Switching difference approx. 9 F (5 K), tolerance -5.4/+3.6 F (-3/+2 K) Option note: connecting terminal "N" (RF heating resistor) enables thermal feedback, reducing the hysteresis - amount is subject to 1.5" (38 mm) surrounding conditions TBD for each individual application Sensor element thermostatic bimetal Contact type SPDT / change-over contact Service life > 100,000 cycles Max. switching capacity, NC 10 A resistive / 4 A inductive @ AC 120 V 10 A resistive / 4 A inductive @ AC 250 V 1.97" (50 mm) DC 30 W Max. switching capacity, NO 5 A resistive / 2 A inductive @ AC 120 V 5 A resistive / 2 A inductive @ AC 250 V 2.64" (67 mm) DC 30 W Connection 4-pole terminal, clamping torque 0.5 Nm max.: solid wire - AWG 14 max. (2.5 mm) stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / storage temperature -49 to +149 F (-45 to +65 C) Dimensions 2.64 x 1.97 x 1.5" (67 x 50 x 38 mm) Weight approx. 3.5 oz. (100g) Protection type IP20 FZK 011 Thermostat Heater FZK 011 Thermostat e.g. Filter Fan FZK 011 Thermostat e.g. Signal Device Enclosure heater Filter fan, cooling equipment, signal device Part No. 01170.0-00 01170.0-01 01170.9-00 01170.9-01 Operating voltage1) AC 230 V AC 230 V AC 120 V AC 120 V Setting range 5 to 60 C 40 to 140 F 40 to 140 F 5 to 60 C Approvals UL File No. E164102 UL File No. E164102 UL File No. E164102 UL File No. E164102 1) Voltage only needs to be specified if the optional use of the RF resistor is desired. Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FZK011/11-12/US Wiring examples ETR 011 Electronic Thermostat Large setting range Compact design Small hysteresis Optical function display (LED) The ETR 011 electronic thermostat is used for controlling heating and cooling equipment, filter fans, or signal devices. The thermostat senses the surrounding air temperature and can switch both resistive and inductive loads via an SPDT contact. The integrated LED is lit when the NC contact is closed (i.e. connected heater is operating). Regulating DIN rail mountable | Technical Data Switching difference 7 F (4 K) 1.8 F (1 K) tolerance - at 68 F (20 C) Sensor element NTC Reaction time approx. 5 seconds Contact type SPDT / change-over contact (relay) Service life > 50,000 cycles Max. switching capacity (relay output) 8 A resistive / 1.6 A inductive @ AC 120 V 8 A resistive / 1.6 A inductive @ AC 240 V 4 A @ DC 24 V Max. inrush current AC 16 A for 10 sec. Connection 5-pole terminal, clamping torque 0.5 Nm max.: solid wire - AWG 14 max. (2.5 mm) stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -40 to +185 F (-40 to +85 C) Dimensions 2.54 x 1.65 x 1.5" (64.5 x 42 x 38 mm) Weight approx. 2.5 oz. (70 g) Protection type IP20 ETR 011 Thermostat Heater ETR 011 Thermostat e.g. Filter Fan ETR 011 Thermostat e.g. Signal Device 120 V 50/60 Hz Part No. 01131.0-00 01131.9-00 Operating voltage AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz Setting range -20 to 60 C -4 to 140 F Approvals CSA-US*, VDE CSA-US* *Tested according to UL Standard No. 873 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com ETR011/11-12/US Wiring example ET 011 Electronic Thermostat (DC 24 V) 16 Amp DC switching capacity Low hysteresis Wide adjustment range The ET 011 is an electronic thermostat for regulating high performance DC 24 V equipment. Heating or cooling equipment, as well as signal devices, can be switched via the SPDT (changeover) contact. Regulating DIN rail mountable 1.8" (46 mm) A relatively small hysteresis sets the ET 011 Thermostat apart from less accurate mechanical thermostats. | 2.0" (50 mm) 20 30 40 2.6" (67 mm) 10 50 60 0 C DC 24V Technical Data Switching difference approx. 5.4 F 1.8 F tolerance (3 K 1 K) Sensor element PTC Contact type SPDT / change-over contact Service life > 100,000 cycles Max. switching capacity 16 A @ DC 28 V Connection 5-pole terminal, clamping torque 0.5 Nm max.: solid wire - AWG 14 max. (2.5 mm) - ET 011 Thermostat + 2 Heater 4 1 stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating temperature +32 to +140 F (0 to +60 C) Storage temperature -49 to +176 F (-45 to +80 C) Dimensions 2.6 x 2.0 x 1.8" (67 x 50 x 46 mm) Weight approx. 2.8 oz. (80 g) Protection type IP20 ET 011 Thermostat e.g. Filter Fan ET 011 Thermostat e.g. Signal Device Part No. 01190.0-00 01190.0-01 Operating voltage DC 24 V (DC 20-28 V) DC 24 V (DC 20-28 V) Setting range 0 to 60 C 32 to 140 F Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com ET011/11-12/US Wiring examples EFR 012 Electronic Hygrostat Adjustable & pre-set relative humidity setpoints Compact design High switching capacity Optical function display (LED) The EFR 012 electronic hygrostat senses the relative humidity in an enclosure and turns on a heater at the set point, helping prevent the formation of condensation in the enclosure. The integrated LED is lit when the connected device is in operation. Regulating DIN rail mountable | Technical Data Switching difference 5 %RH ( 1 % tolerance) - at 77 F (25 C) and 50 %RH Reaction time approx. 5 seconds Contact type SPDT / change-over contact (relay) Service life > 50,000 cycles Max. switching capacity (relay output) 8 A resistive / 1.6 A inductive @ AC 120 V 8 A resistive / 1.6 A inductive @ AC 240 V 4 A @ DC 24 V Max. inrush current AC 16 A for 10 sec. Connection 5-pole terminal, clamping torque 0.5 Nm max.: solid wire - AWG 14 max. (2.5 mm) stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating temperature +32 to +140 F (0 to +60 C) Storage temperature -4 to +176 F (-20 to +80 C) Max. storage humidity 90 %RH (non-condensing) Dimensions 2.54 x 1.65 x 1.5" (64.5 x 42 x 38 mm) Weight approx. 2.3 oz. (65 g) Protection type IP20 EFR 012 Hygrostat Heater 4 N 120 V 50/60 Hz Operating voltage AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz Setting range 40 to 90 %RH 40 to 90 %RH 65 %RH pre-set 65 %RH pre-set Approvals CSA-US*, VDE CSA-US* CSA-US*, VDE CSA-US* *Tested according to UL Standard No. 873 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com EFR012/11-12/US Part No. 01245.0-00 01245.9-00 01246.0-00 01246.9-00 Wiring example MFR 012 Mechanical Hygrostat Efficient condensation control Adjustable relative humidity range High switching capacity The MFR 012 electromechanical hygrostat is designed to control the relative humidity inside enclosures. When connected to an enclosure heater (dehumidifier), it will energize the heater at the humidity set point in order to raise the dew point. This helps prevent damage and malfunction of electronic components caused by condensation and corrosion.1) Regulating DIN rail mountable The MFR 012 can also be used to control cooling fans, warning lights or other devices. | 1.5" (38 mm) Technical Data 1.97" (50 mm) Switching difference 4 %RH ( 3 % tolerance) - at 50 %RH Permissible air velocity 50 ft/sec (15 m/s) Contact type SPDT / change-over contact Service life > 100,000 cycles Min. Switching capacity 100 mA @ AC/DC 20 V Max. Switching capacity 5 A resistive @ AC 250 V 2.64" (67 mm) DC 20 W Max. inrush current AC 5 A Connection 3-pole terminal, clamping torque 0.5 Nm max.: solid wire - AWG 14 max. (2.5 mm) stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating temperature +32 to +140 F (0 to +60 C) Storage temperature -4 to +176 F (-20 to +80 C) Dimensions 2.64 x 1.97 x 1.5" (67 x 50 x 38 mm) Weight approx. 2 oz. (60 g) Protection type IP20 Approvals UL File No. E164102 1) The critical relative humidity level for most components is 65 %. Above 65 %RH, condensation can form and cause malfunctions of electronic equipment. Long term, this can lead to corrosion and permanent damage of electronic components and systems. Enclosure heater Part No. 01220.0-00 Setting range 35 to 95 %RH Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com MFR012/11-12/US Filter fan, cooling equipment, signal device ETF 012 Electronic Hygrotherm Efficient temperature & humidity control Wide adjustment ranges High switching capacity Optical function displays (LED) The ETF 012 senses the ambient temperature and relative air humidity. Depending on which contact combination is chosen, it then turns on or off a connected device if either the temperature is below or the humidity is above the set point. The integrated LED in each adjustment knob is lit when indicating the active function. Regulating DIN rail mountable | Technical Data Switching difference - temperature 3.6 F (2 K) 1 K tolerance - at 77 F (25 C) and 50 %RH Switching difference - humidity 4 %RH 1 % tolerance - at 77 F (25 C) and 50 %RH Response time - humidity approx. 5 sec. Contact type SPDT / change-over contact (relay) Service life NC: > 50,000 cycles NO: > 100,000 cycles Max. switching capacity NC: 6 A resistive / 1 A inductive @ AC 120 V NO: 8 A resistive / 1.6 A inductive @ AC 120 V NC: 6 A resistive / 1 A inductive @ AC 240 V NO: 8 A resistive / 1.6 A inductive @ AC 240 V 4 A @ DC 24 V Max. inrush current AC 16 A for 10 sec. Connection 5-pole terminal, clamping torque 0.5 Nm max.: solid wire - AWG 14 max. (2.5 mm) stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating temperature +32 to +140 F (0 to +60 C) Storage temperature -4 to +176 F (-20 to +80 C) Dimensions 3.0 x 2.4 x 1.7" (77 x 60 x 43 mm) Weight approx. 7 oz. (200 g) Protection type IP20 ETF 012 Hygrotherm Heater N Part No. Operating voltage Setting range - temperature Setting range - humidity Approvals 01230.0-00 01230.0-01 01230.9-00 01230.9-01 AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz 0 to 60 C 32 to 140 F 32 to 140 F 0 to 60 C 50 to 90 %RH 50 to 90 %RH UL File No. E164102, VDE UL File No. E164102, VDE UL File No. E164102 UL File No. E164102 50 to 90 %RH 50 to 90 %RH Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com ETF012/11-12/US Wiring example SM 010 Electronic Relay (DC 24 V & DC 48 V) 16 Amp DC switching capacity Variety of applications Compact design 1.8" (46 mm) The SM 010 Electronic Relay is used for switching high powered DC operated equipment, such as heaters, up to 16 amps. A separate conventional switch contact is used as controller (e.g. thermostat, hygrostat). The electronic relay is available in DC 24 V and DC 48 V versions. Regulating DIN rail mountable 2.0" (50 mm) | Technical Data 2.6" (67 mm) Contact type / DC 48V NO - normally open (Relay/MOSFET) Service life > 100,000 cycles Max. inrush current DC 16 A Connection 6-pole terminal, clamping torque 0.5 Nm max.: Us DC 48V solid wire - AWG 14 max. (2.5 mm) stranded wire (w/ wire end ferrule) - AWG 16 max. (1.5 mm) - + 1 2 - + Load, e.g. heater, cooling device with temperature limiter SM 010 Electronic relay Housing plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 2.6 x 2.0 x 1.8" (67 x 50 x 46 mm) Weight approx. 3.0 oz. (85 g) Protection type IP20 Approvals VDE, UL File No. E342261 Load, e.g. heater, cooling device without temperature limiter Control contact, e.g. thermostat, hygrostat, or pressure regulator SM 010 Electronic relay Control contact, e.g. thermostat, hygrostat, or pressure regulator Part No. 01000.0-01 01001.0-01 Operating voltage DC 48 V (DC 38-56 V) DC 24 V (DC 20-28 V) Max. Switching capacity 16 A @ DC 56 V 16 A @ DC 28 V Signal current 10 mA @ DC 38 V / 18 mA @ DC 56 V 13 mA @ DC 20 V / 22 mA @ DC 28 V Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com SM010/11-12/US Wiring examples REx 011 Explosion-proof Thermostat Compact design Fixed temperature setpoints High switching capacity The design of the REx 011 thermostat ensures high accuracy, small switching difference (hysteresis) and a long service life. Regulating DIN rail mountable Because of the high switching capacity of the thermostat, heaters can usually be directly connected and switched without the need for additional relays. | Technical Data 01 ATEX 6074/02, LCIE N06 ATEX Q8011, IECEx LCI 07. 0021 Sensor element thermostatic bimetal Contact type NC - normally closed (opens on temperature rise) Service life > 100,000 cycles Max. switching capacity 4 A resistive / 1 A inductive @ AC 250 V Connection Si HF - JZ 3 x AWG 18 (0.75 mm), length 3.3 ft (1 m) Housing aluminum, black anodized Mounting mounting bracket with M8 nut and clip for 35 mm DIN rail Mounting position variable Operating / Storage temperature -49 to +158 F (-45 to +70 C) Weight approx. 7 oz. (200 g) Protection class I (grounded) Protection type IP65 0.79" O0.165" Ex protection type Ex d IIC T6 - Ex tD A21 IP6X T85C Ex d IIC T6 - Ex tD A21 IP6X T85C 0.94" 1.97" 0.08" 1.02" 1.38" 0.79" Part No. 01180.0-00 01181.0-00 O0.14" O0.35" 0.33" (8.5 mm) 4.33" (110 mm) LCIE (Laboratoire Central des Industries Electriques) Conformity certificate Aluminum Mounting Bracket Switch-off temperature 59 F 7 F tolerance (15 C 4 K tolerance) 77 F 7 F tolerance (25 C 4 K tolerance) Switching difference 7 F 2 F tolerance (4 K 1 K tolerance) 7 F 2 F tolerance (4 K 1 K tolerance) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com REx011/11-12/US 0.87" (22 mm) M8 Explosion proof according to EN RCE 016 PTC Heater 5 & 9 W Compact size Wide voltage range Heating power adjusts to ambient temperature The RCE 016 small heaters have been designed to prevent condensation and to ensure a minimum operating temperature in small enclosures. Power / Ambient Temperature Diagram AC/DC 120 - 240 V (W) Heating Energy saving | Technical Data 10 9 Operating voltage see table below Heating element PTC resistor - temperature limiting Heater body aluminum, anodized Insulation PTFE / Kapton Mounting 2 pressure clips included (mounting screws not included) Mounting position variable 3 Operating / Storage temperature -49 to +158 F (-45 to +70 C) 2 Protection class II (double insulated) Protection type IP54 8 01623.0-01 7 6 5 4 01622.0-03 -40 -30 -20 -10 0 10 20 30 40 50 60 (C) Measured in open air Thermostat 1.77" (45 mm) RCE 016 Heater O 0.39" (10 mm) L N 19.7" (500 mm) 2 x AWG 22 (0.25 mm) 1.97" (50 mm) Mounting clip Wiring example O0.9" (2.4mm) Part No. Heating capacity1) Operating voltage2) Max. current (inrush) Surface temperature (approx.)1) Weight (approx.) Approvals 01622.0-03 5W AC/DC 120-240 V 2.0 A 329 F (165 C) 0.7 oz. (20 g) UL File No. E234324, VDE 01623.0-01 9W AC/DC 120-240 V 2.5 A 347 F (175 C) 0.7 oz. (20 g) UL File No. E234324, VDE 01624.0-03 5W AC/DC 12-30 V 5.8 A 284 F (140 C) 0.7 oz. (20 g) UL File No. E234324 01625.0-02 9W AC/DC 12-30 V 2.4 A 360 F (182 C) 0.7 oz. (20 g) UL File No. E234324 68 F (20 C) ambient temperature operating high voltage heaters below AC/DC 140 V reduces heating performance by approx. 10% (min. 110 V, max 265 V). 1) at 2) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com RCE016/11-12/US 0.09" (2.4 mm) RC 016 PTC Heater 8 - 13 W Compact size Wide voltage range Heating power adjusts to ambient temperature The RC 016 small heaters are designed to prevent condensation and to ensure a minimum operating temperature in small enclosures. | Heating Energy saving Technical Data Heating Power in Relation to Ambient Temperature AC/DC 120 - 240 V (W) 30 01610.0-00 28 26 24 22 01609.0-00 20 Operating voltage see table below Heating element PTC resistor - temperature limiting Heater body aluminum, anodized Insulation PTFE / Kapton Mounting screw (mounting screws not included) Mounting position variable Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class II (double insulated) Protection type IP54 18 14 01610.0-00 12 01609.0-00 10 8 11.8" (300 mm) 1.2" (30 mm) 0.49" (12.5 mm) 0.7" (18 mm) 0.07" (1.8 mm) 0.12" (3.2 mm) 2 x AWG 18 (0.75 mm) 0.12" (3.2 mm) 0.18" (4.5 mm) 01602.0-00 0.49" (12.5 mm) 16 01602.0-00 Part. No. 01602.0-00 6 13" (340 mm) 1.97" (50 mm) Thermostat 1.2" (30 mm) 0.07" (1.8 mm) 0.18" 0.18" (4.5 (4.5 mm) mm) 0.49" (12.5 mm) : measured in open air : measured with heater mounted on 100 x 100 x 2 mm (4 x 4 x 0.08")aluminum plate 0.49" (12.5 mm) RC 016 Heater 2) mm) 22 xx AWG AWG22 24(0.25 (0.2 mm 2.36"(60 mm) 0.18" 0.18" (4.5mm) (4.5mm) 0.49" (12.5 mm) 0.07" (1.8 mm) L N Wiring example 13" (340 mm) 2) 22xxAWG AWG 24 22 (0.25 mm) 24(0.2 (0.2mm 1.57" (40 mm) 0.2" (5mm) 0.49" (12.5 mm) Part. No. 01609.0-00 Part. No. 01610.0-00 Part No. Heating capacity1) Operating voltage2) Max. current (inrush) Surface temperature (approx.)1) Weight (approx.) Approvals 01602.0-00 8W AC/DC 120-240 V 2.0 A 302 F (150 C) 0.7 oz. (20 g) UL File No. E234324, VDE 01602.0-03 8W AC/DC 12-30 V 3.7 A 273 F (134 C) 0.7 oz. (20 g) UL File No. E234324 01609.0-00 01609.0-01 01610.0-00 01610.0-01 10 W 10 W 13 W 13 W AC/DC 120-240 V AC/DC 12-30 V AC/DC 120-240 V AC/DC 12-30 V 2.5 A 5.7 A 3.0 A 10.0 A 311 F (155 C) 270 F (132 C) 338 F (170 C) 298 F (148 C) 1.0 oz. (28 g) 1.0 oz. (28 g) 1.2 oz. (34 g) 1.2 oz. (34 g) UL File No. E234324, VDE UL File No. E234324 UL File No. E234324, VDE UL File No. E234324 68F (20C) ambient temperature operating high voltage heaters below AC/DC 140V reduces heating performance by approx. 10% (min. 110V, max 265V). 1) at 2) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com RC016/11-12/US (C) (F) 0.2" (5mm) -20 -10 0 10 20 30 40 50 60 -4 14 32 50 68 86 104 122 140 CSK 060 Touch-Safe PTC Heater 10 & 20 W Low surface temperature Compact size Wide voltage range Double insulated protection The CSK 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. Heating DIN rail mountable | Technical Data Heating capacity see table Heating element PTC resistor - temperature limiting Surface temperature < 185 F (85 C), except upper protective grill Connection 2-pole terminal AWG 14 max (2.5 mm), torque 0.8 Nm max. Mounting clip for 35 mm DIN rail, EN 60715 Housing plastic, UL 94V-0, black Mounting position vertical Operating / storage temperature -49 to +158 F (-45 to +70 C) Protection class II (double insulated) Protection type IP20 Approvals UL File No. E234324, VDE Note other voltages available upon request Thermostat CSK 060 Heater Part No. 06030.0-00 06040.0-00 06040.1-00 Heating capacity1) 20 W 10 W 10 W Operating voltage2) AC/DC 120-240 V AC/DC 120-240 V AC/DC 12-30 V Max. current (inrush) 2.5 A 1.0 A 8A Dimensions 3.86 x 2.95 x 1.5" (98 x 75 x 38 mm) 3.86 x 2.95 x 1.5" (98 x 75 x 38 mm) 3.86 x 2.95 x 1.5" (98 x 75 x 38 mm) Weight (approx.) 6.1 oz. (170 g) 5.0 oz. (140 g) 5.0 oz. (140 g) 68 F (20 C) ambient temperature operating high voltage heaters below AC/DC 140 V reduces heating performance by approx. 10% (min. 110 V, max 265 V). 1) at 2) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CSK060/11-12/US Wiring example HGK 047 PTC Heater 10 - 30 W Compact size Wide voltage range Heating power adjusts to ambient temperature The HGK 047 heaters are used in enclosures to maintain minimum operating temperatures and to help prevent failure of electronic components caused by condensation and corrosion. Heating DIN rail mountable | 0.98" (25 mm) Technical Data 1.97" (50 mm) Operating voltage see table below Heating element PTC resistor - temperature limiting Heater body extruded aluminum profile, anodized Connection 3 x AWG 20 (0.5 mm), 12" (300 mm) length Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class I (grounded) Protection type IP44 HGK 047 Heater L Thermostat 11.8" (300 mm) 0.47" (12 mm) L N Part No. Heating capacity1) Operating voltage2) 04700.0-00 04701.0-00 04702.0-00 04700.9-00 04701.9-00 04702.9-00 10 W 20 W 30 W 10 W 20 W 30 W AC/DC 140-240 V AC/DC 140-240 V AC/DC 140-240 V AC/DC 110-120 V AC/DC 110-120 V AC/DC 110-120 V Max. current (inrush) 1.0 A 2.5 A 3.0 A 1.0 A 1.5 A 1.5 A Length (L) Weight (approx.) Approvals 2.05" (52 mm) 2.36" (60 mm) 2.76" (70 mm) 2.05" (52 mm) 2.76" (70 mm) 3.94" (100 mm) 3.0 oz. (85 g) 3.6 oz. (100 g) 4.0 oz. (110 g) 3.0 oz. (85 g) 4.0 oz. (110 g) 5.2 oz. (150 g) VDE VDE VDE UL File No. E234324 UL File No. E234324 UL File No. E234324 68 F (20 C) ambient temperature operating with voltages below AC/DC 140 V reduces heating performance by approx. 10% (min. 110 V, max 265 V). 1) at 2) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com HGK047/11-12/US Wiring example CS 060 Touch-Safe PTC Heater 50 - 150 W Low surface temperature Compact size Wide voltage range Double insulated protection The CS 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 060 is also available in a version with a plug-in thermostat requiring no additional wiring (CSF 060). Heating DIN rail mountable | Technical Data Operating voltage* AC/DC 120-240 V (min. 110 V, max. 265 V) Heating capacity see table Heating element PTC resistor - temperature limiting Surface temperature < 176 F (80 C), except upper protective grill Connection 4-pole terminal AWG 14 max (2.5 mm), torque 0.8 Nm max. Housing plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class II (double insulated) Protection type IP20 Approvals UL File No. E234324, VDE Note other voltages available upon request *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. 200 178 CS 060 Heater 160 132 122 1) see Heating capacity1) 50 W 100 W 150 W 119 110 93 85 66 61 50 -20C -4F 100 W 55 50 0 -40C -40F Max. current (inrush) 2.5 A 4.5 A 8A 150 W 102 100 Wiring examples Part No. 06000.0-00 06010.0-00 06020.0-00 147 150 0C 32F Ambient Temperature Air outlet temperature2) 187 F (86 C) 248 F (120 C) 293 F (145 C) 20C 68F Dimensions 4.3 x 2.36 x 3.54" (110 x 60 x 90 mm) 4.3 x 2.36 x 3.54" (110 x 60 x 90 mm) 5.9 x 2.36 x 3.54" (150 x 60 x 90 mm) 44 40C 104F Weight (approx.) 10.4 oz. (295 g) 10.6 oz. (300 g) 15.5 oz. (440 g) Heating capacity / Ambient temperature diagram 2" (50 mm) above protective grill 2) measured Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com 50 W CS060/11-12/US Thermostat Heating Power (W) CS 060 Heater CSF 060 Touch-Safe PTC Heater 50 - 150 W Low surface temperature Integrated thermostat Compact size Wide voltage range Double insulated protection The CSF 060 is a touch-safe heater for use in enclosures. The design of the heater utilizes natural convection which results in a circulating current of warm air. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. This model with plug-in thermostat does not require additional wiring. The CSF 060 is also available in a version without thermostat (CS 060). Heating DIN rail mountable | Technical Data Operating voltage* AC/DC 120-240 V (min. 110 V, max. 265 V) Heating capacity see table Heating element PTC resistor - temperature limiting Surface temperature < 176 F (80 C), except upper protective grill Connection 4-pole terminal AWG 14 max (2.5 mm), torque 0.8 Nm max. Housing plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -40 to +158 F (-40 to +70 C) / -49 to +158 F (-45 to +70 C) Protection class II (double insulated) Protection type IP20 Approvals VDE *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. 200 178 160 147 150 132 122 150 W 102 100 93 85 66 61 50 -20C -4F 100 W 55 50 0 -40C -40F Wiring example 119 110 0C 32F Ambient Temperature Switch-on temperature3) 20C 68F 44 50 W 40C 104F Part No. Heating capacity1) Max. current (inrush) Air outlet temperature2) Switch-off temperature3) Weight (approx.) 06001.0-00 50 W 2.5 A 187 F (86 C) 59 F (15 C) 41 F (5 C) 5.24 x 2.36 x 3.54" (133 x 60 x 90 mm) 10.8 oz. (305 g) 06002.0-00 50 W 2.5 A 187 F (86 C) 77 F (25 C) 59 F (15 C) 5.24 x 2.36 x 3.54" (133 x 60 x 90 mm) 10.8 oz. (305 g) 06011.0-00 100 W 4.5 A 248 F (120 C) 59 F (15 C) 41 F (5 C) 5.24 x 2.36 x 3.54" (133 x 60 x 90 mm) 11.2 oz. (320 g) 06012.0-00 100 W 4.5 A 248 F (120 C) 77 F (25 C) 59 F (15 C) 5.24 x 2.36 x 3.54" (133 x 60 x 90 mm) 11.2 oz. (320 g) 06021.0-00 150 W 8.0 A 293 F (145 C) 59 F (15 C) 41 F (5 C) 6.8 x 2.36 x 3.54" (173 x 60 x 90 mm) 15.9 oz. (450 g) 06022.0-00 150 W 8.0 A 293 F (145 C) 77 F (25 C) 59 F (15 C) 6.8 x 2.36 x 3.54" (173 x 60 x 90 mm) 15.9 oz. (450 g) Dimensions 1) see Heating capacity / Ambient temperature diagram 2) measured 2" (50 mm) above protective grill 3) tolerance of 5K Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CSF060/11-12/US Heating Power (W) CSF 060 Heater HG 140 PTC Heater 15 - 150 W Compact size Wide voltage range Heating power adjusts to ambient temperature Cage clamp connectors for quick & easy wiring These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature must be maintained above a minimum value. The aluminum profile heater body design has a chimney effect to distribute heat evenly. The cage clamp connectors save time and simplify installation. Heating DIN rail mountable | Technical Data Operating voltage* AC/DC 120-240 V (min. 110 V, max. 265 V) Heating element PTC resistor - temperature limiting Heater body extruded aluminum profile, anodized Connection 3 cage clamps for solid wire AWG 20-14 (0.5-2.5 mm), and stranded wire AWG 20-16 (0.5-1.5 mm) with wire end ferrule Connection casing plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class I (grounded) Protection type IP20 Approvals UL File No. E234324, VDE Note other voltages available upon request 1) at Part No. Heating capacity1) Max. current (inrush) Length (L on dim. dwg.) Weight (approx.) 14000.0-00 15 W 1.5 A 2.56" (65 mm) 7.6 oz. (215 g) 14001.0-00 30 W 3.0 A 2.56" (65 mm) 7.6 oz. (215 g) 14003.0-00 45 W 3.5 A 2.56" (65 mm) 7.6 oz. (215 g) 14005.0-00 60 W 2.5 A 5.5" (140 mm) 14.1 oz. (400 g) 14006.0-00 75 W 4.0 A 5.5" (140 mm) 14.3 oz. (405 g) 14007.0-00 100 W 4.5 A 5.5" (140 mm) 14.3 oz. (405 g) 14008.0-00 150 W 9.0 A 8.66" (220 mm) 21.3 oz. (600 g) 68 F (20 C) ambient temperature Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com HG140/11-12/US *Operating with voltages below AC/DC 140 V reduces heating performance by approx. 10%. CS 028 Touch-Safe PTC Fan Heater 150 W Compact size Quiet operation Heating power adjusts to ambient temperature 2.56" (65 mm) The CS 028 fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. The heater is connected using the internal terminal connectors. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CS 028's small size make it ideal for use in enclosures where space is at a premium. Heating DIN rail or screw mount available | Technical Data 3.54" (90 mm) Heating element PTC resistor - temperature limiting Max. current (inrush) 6 A @ AC 120 V, 12 A @ AC 230 V Surface temperature max. 122 F (50 C) at housing, 212 F (100 C) at top grill; 2.95" (75 mm) measured at 68 F (20 C) ambient temperature View: back side Screw mount 3.74" (95 mm) 2.95" (75 mm) DIN clip Axial fan, ball bearing service life 40,000 h at 104 F (40 C) Air flow, free blowing approx. 8 cfm (13.8 m/h) Connection 2-pole terminal AWG 14 max. (2.5 mm), torque 0.8 Nm max. Mounting screw mount or clip for 35 mm DIN rail, EN 60715 Housing plastic, UL 94V-0, black Weight approx. 10.6 oz. (300 g) Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class II (double insulated) Protection type IP20 Note other voltages available upon request CS 028 Fan Heater Thermostat 20 10 0 30 Heating Power (W) 1.26" (32 mm) 40 50 3 4 60 -40 C -40 F L -20 C -4 F 0 C 32 F 20 C 68 F 40 C 104 F Ambient Temperature N Part No. 02800.0-00 02800.0-01 02800.9-00 02800.9-01 1) at Heating capacity1) 150 W 150 W 150 W 150 W Operating voltage AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz Dimensions 2.95 x 2.56 x 3.54" (75 x 65 x 90 mm) 4.49 x 2.56 x 3.54" (114 x 65 x 90 mm) 2.95 x 2.56 x 3.54" (75 x 65 x 90 mm) 4.49 x 2.56 x 3.54" (114 x 65 x 90 mm) Mounting DIN clip Screw mount DIN clip Screw mount Approvals UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324 UL File No. E234324 68 F (20 C) ambient temperature Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CS028/11-12/US Wiring example CSL 028 Touch-Safe PTC Fan Heater 250 & 400 W Compact size Quiet operation Heating power adjusts to ambient temperature 3.35" (85 mm) The CSL 028 fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. The heater is connected using the internal terminal connectors. The surface temperatures on the accessible side surfaces of the housing are minimized as a result of the heater design. The CSL 028's small size make it ideal for use in enclosures where space is at a premium. Heating DIN rail or screw mount available | Technical Data 4.37" (111 mm) Heating element PTC resistor - temperature limiting Surface temperature 250 W: max. 122 F (50 C) except upper protective grill, 3.54" (90 mm) 400 W: max. 149 F (65 C) except upper protective grill; measured at 68 F (20 C) ambient temperature Axial fan, ball bearing service life 40,000 h at 104 F (40 C) Air flow, free blowing 32 cfm (54 m/h) at AC 120 V; 26 cfm (45 m/h) at AC 230 V Connection 2-pole terminal AWG 14 max. (2.5 mm) with strain relief, screw torque 0.8 Nm max. View: back side DIN clip 1.26" (32 mm) Thermostat screw mount or clip for 35 mm DIN rail, EN 60715 Housing plastic, UL 94V-0, black Weight approx. 17.6 oz. (500 g) Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class II (double insulated) Protection type IP20 Heating Power (W) 4.33" (110 mm) Screw mount Mounting CSL 028 Fan Heater Wiring example -40C -40F -20C -4F 0C 32F 20C 68F 40C 104F 60C 140F Part No. 02810.0-00 02810.0-01 02810.9-00 02810.9-01 02811.0-00 02811.0-01 02811.9-00 02811.9-01 1) at Heating capacity1) 400 W 400 W 400 W 400 W 250 W 250 W 250 W 250 W Operating voltage AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz Max. current (inrush) 15 A 15 A 9A 9A 9A 9A 6A 6A Dimensions 3.54 x 3.35 x 4.37" (90 x 65 x 111 mm) 5.08 x 3.35 x 4.37" (129 x 65 x 111 mm) 3.54 x 3.35 x 4.37" (90 x 65 x 111 mm) 5.08 x 3.35 x 4.37" (129 x 65 x 111 mm) 3.54 x 3.35 x 4.37" (90 x 65 x 111 mm) 5.08 x 3.35 x 4.37" (129 x 65 x 111 mm) 3.54 x 3.35 x 4.37" (90 x 65 x 111 mm) 5.08 x 3.35 x 4.37" (129 x 65 x 111 mm) Mounting DIN clip Screw mount DIN clip Screw mount DIN clip Screw mount DIN clip Screw mount Approvals UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324 UL File No. E234324 UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324 UL File No. E234324 68F (20C) ambient temperature Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CSL028/11-12/US Ambient Temperature HVL 031 Fan Heater 100 - 400 W Compact size Flat design Built-in overheat protection The compact HVL 031 high-performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. For large OEM use, this fan heater can also be provided without the fan, in which case the OEM/customer must provide a fan which meets the minimum airflow requirements. Shown: 100W - HVL 031 Fan Heater Heating 3-side DIN rail mountable | Technical Data Important! Heater must be operated together with a fan. Operating without a fan creates the danger of overheating. 100W/ 150W Heater 0.98" (25 mm) 0.87" (22 mm) 0.16" (4.2 mm) 3.15" (80 mm) 2.81" (71.5 mm) Mounting hole for DIN clip 2.68" (68 mm) high performance cartridge Overheat protection built-in temperature limiter Heater body die-cast aluminum, glass bead finish Connection 3-pole terminal AWG 14 max. (2.5 mm), torque 0.8 Nm max.. Connection housing plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715 Mounting position horizontal Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class / Protection type I (grounded) / IP20 Axial fan, ball bearing service life 50,000 h at 77 F (25 C) Air flow, free blowing see table below Axial fan connection 2-pole terminal AWG 14 max. (2.5 mm), terminals L2/N2 Approvals UL File No. E187294 (all), VDE (230VAC only) Air flow 1.26" (32 mm) Label Heating element Axial fan HVL 031 Fan Heater 0.71" (18 mm) 200W/ 300W/ 400W Heater 0.16" (4.2 mm) 4.68" (119 mm) 4.13" (104.8 mm) Mounting hole for DIN clip 0.98" (25 mm) 0.87" (22 mm) 2.68" (68 mm) Air flow 1.26" (32 mm) Label Thermostat 1 2 L N Axial fan Part No. - AC 120 V Part No. - AC 230 V Heating capacity Min. airflow (free blowing) Dimensions (as mounted) Weight (approx.) 03102.9-00 03102.0-00 100 W 20 cfm (35 m/h) 1.85 x 3.15 x 4.41" (47 x 80 x 112 mm) 1.3 lbs. (600 g) 03103.9-00 03103.0-00 150 W 20 cfm (35 m/h) 1.85 x 3.15 x 4.41" (47 x 80 x 112 mm) 1.3 lbs. (600 g) 03113.9-00 03113.0-00 200 W 63 cfm (108 m/h) 1.85 x 4.68 x 5.94" (47 x 119 x 151 mm) 2.0 lbs. (900 g) 03114.9-00 03114.0-00 300 W 63 cfm (108 m/h) 1.85 x 4.68 x 5.94" (47 x 119 x 151 mm) 2.0 lbs. (900 g) 03115.9-00 03115.0-00 400 W 63 cfm (108 m/h) 1.85 x 4.68 x 5.94" (47 x 119 x 151 mm) 2.0 lbs. (900 g) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com HVL031/11-12/US 0.71" (18 mm) HGL 046 Fan Heater 250 & 400 W Compact size Built-in overheat protection Long service life The compact HGL 046 fan heater prevents formation of condensation. The integrated high performance axial fan provides forced air circulation and so guarantees an even temperature in enclosures. The heater is wired using the internal terminal connectors. Heating DIN rail mountable | 3.35" (85 mm) 3.94" (100 mm) Technical Data 3.35" (85 mm) Heating element resistance - micanite Overheat protection built-in temperature limiter Heater body extruded aluminum, anodized Surface temperature 400 W heater - max. 167 F (75 C) Axial fan, ball bearing service life 50,000 h at 77 F (25 C) Air flow, free blowing AC: 26 cfm (45 m/h) - 50 Hz; 32 cfm (54 m/h) - 60 Hz DC: 32 cfm (54 m/h) Connection 3-pole terminal AWG 16 max. (1.5 mm) with strain relief, L clamping torque 0.8 Nm max. Connection housing plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class I (grounded) Protection type IP20 Note: In the case of DC 24 V and DC 48 V, the fan heater must be switched via a relay. For this application, the SM 010 Electronic Relay (Part No. 01000.0-00 or 01001.0-00) is recommended. Heater Fan Heater HGL 046 (AC 120 V or AC 230 V) Heater Fan Heater HGL 046 (DC 24 V or DC 48 V) SM 010 Electronic relay Pilot contact e.g. KT 011 Thermostat Part No. Heating capacity Operating voltage Length (L) Weight (approx.) Approvals 04640.0-00 250 W AC 230 V, 50/60 Hz 7.2" (182 mm) 2.4 lbs. (1.1 kg) UL File No. E234324, VDE 04641.0-00 400 W AC 230 V, 50/60 Hz 8.7" (222 mm) 3.1 lbs. (1.4 kg) UL File No. E234324, VDE 04640.9-00 250 W AC 120 V, 50/60 Hz 7.2" (182 mm) 2.4 lbs. (1.1 kg) UL File No. E234324, VDE 04641.9-00 400 W AC 120 V, 50/60 Hz 8.7" (222 mm) 3.1 lbs. (1.4 kg) UL File No. E234324, VDE 04640.1-00 250 W DC 24 V 7.2" (182 mm) 2.4 lbs. (1.1 kg) UL File No. E234324 04640.2-00 250 W DC 48 V 7.2" (182 mm) 2.4 lbs. (1.1 kg) UL File No. E234324 04641.2-00 400 W DC 48 V 8.7" (222 mm) 3.1 lbs. (1.4 kg) UL File No. E234324 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com HGL046/11-12/US Pilot contact e.g. KT 011 Thermostat CR 027 PTC Fan Heater 400 - 650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection The semiconductor CR 027 fan heater prevents the formation of condensation and ensures an even temperature in enclosures. The integrated thermostat is used to set the desired temperature while the high performance axial fan provides forced air circulation. The CR 027 is also available with a continuously running fan (when powered). Heating DIN rail mountable 3.94" (100 mm) | Technical Data 5" (128 mm) 6.5" (165 mm) 4.8" (124 mm) Wiring note: Only connect the L and N1 terminals - N2 is not Heating element PTC resistor - temperature limiting Overheat protection built-in temperature limiter Axial fan, ball bearing service life 50,000 h at 77 F (25 C) Air flow, free blowing see table below Connection 2-pole terminal AWG 14 max. (2.5 mm), torque 0.8 Nm max.. Housing plastic, UL 94V-0, light grey Optical indicator thermostat control light Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 6.5 x 3.94 x 5.0" (165 x 100 x 128 mm) Protection class II (double insulated) Protection type IP20 Approvals UL File No. E204590 used and Grounding is not required Heating Power / Ambient Temperature (@ 50 Hz) Heating Power / Ambient Temperature (@ 60 Hz) 900 850 Heating Power (W) Heating Power (W) 800 750 700 650 600 650W 550 500 550W 450 -20 C -4 F 0 C 32 F 20 C 68 F 400 -40C -40 C -40F -40 F 40 C 104 F Part No. 02700.0-00 02701.0-00 02700.9-00 02701.9-00 1) at Heating (@ 50 Hz) 475 W 550 W 400 W 510 W 00C C 32F 32 F 20C 20 C 68F 68 F 4040C C 104F 104 F Temperature Temperature capacity1) -20C -20 C -4F -4 F capacity1) Heating (@ 60 Hz) 550 W 650 W 550 W 650 W AC 220-240 V AC 220-240 V Max. current (inrush) 11.0 A 13.0 A Air flow, free blowing 20 cfm (35 m/h) 26 cfm (45 m/h) Thermostat setting range 0 to 60 C 0 to 60 C Weight (approx.) 2.0 lbs. (0.9 kg ) 2.4 lbs (1.1 kg) AC 100-120 V AC 100-120 V 14.0 A 15.0 A 20 cfm (35 m/h) 26 cfm (45 m/h) 32 to 140 F 32 to 140 F 2.0 lbs. (0.9 kg ) 2.4 lbs (1.1 kg) Operating voltage 68 F (20 C) ambient temperature Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CR027/11-12/US -40 C -40 F CR 030 Foot-mount Fan Heater 950 W Compact design Built-in overheat protection Integrated adjustable thermostat or fixed hygrostat The compact CR 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an integrated thermostat for temperature control or a pre-set hygrostat for humidity control. The CR 030 was designed as a stationary unit for the bottom of the enclosure. For panel or DIN rail mount, the CR 130 fan heater is recommended. Heating Double insulated plastic housing | Technical Data Heating element high performance cartridge Overheat protection built-in temperature limiter Heater body extruded aluminum Axial fan, ball bearing service life 50,000 h at 77 F (25 C) Air flow, free blowing 94 cfm (160 m/h) Connection 2-pole terminal AWG 14 max. (2.5 mm) with strain relief, clamping torque 0.8 Nm max. Housing plastic, UL 94V-0, black Mounting M5 screws (not included) Mounting position horizontal Operating* / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 3.9 x 5.7 x 6.6" (100 x 145 x 168 mm) Weight approx. 3.1 lbs. (1.4 kg) Protection class II (double insulated) Protection type IP20 * Operating temperature of heater with integrated hygrostat: +32 to +140 F (0 to +60 C) 6.6" (168 mm) N L L M Wiring diagram 3.9" (100 mm) 30 Part No. 03051.0-00 03051.0-02 03051.0-07 03059.9-00 03059.9-02 N Heating capacity 950 W 950 W 950 W 950 W 950 W Operating voltage AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz Setting range 0 to 60 C 65 %RH, factory-set none (no integrated controls) 32 to 140 F none (no integrated controls) Approvals UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324 UL File No. E234324 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CR030/11-12/US 5.7" (145 mm) 5.1" (130 mm) 4.1" (105 mm) CR 130 Panel-mount Fan Heater 950 W Compact design Built-in overheat protection Integrated adjustable thermostat or fixed hygrostat Double insulated plastic housing The compact CR 130 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an integrated thermostat for temperature control or a pre-set hygrostat for humidity control. The CR 130 was designed as a stationary unit for panel or DIN rail mounting. For foot mounting on the bottom of an enclosure, the CR 030 fan heater is recommended. Heating Panel or DIN rail mounting | Technical Data Heating element high performance cartridge Overheat protection built-in temperature limiter Heater body extruded aluminum Axial fan, ball bearing service life 50,000 h at 77 F (25 C) Air flow, free blowing 94 cfm (160 m/h) Connection 2-pole terminal AWG 14 max. (2.5 mm) with strain relief, clamping torque 0.8 Nm max. Housing plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715 or M6 screws (not included) Mounting position horizontal Operating* / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 3.9 x 6.3 x 7.2" (99 x 160 x 182 mm) Weight approx. 3.1 lbs. (1.4 kg) Protection class II (double insulated) Protection type IP20 6.3" (160 mm) * Operating temperature of heater with integrated hygrostat: +32 to +140 F (0 to +60 C) 3.9" (99 mm) 7.2" (182 mm) N N L L M Wiring diagram Part No. Heating capacity Operating voltage Setting range Approvals 13051.0-00 950 W AC 230 V, 50/60 Hz 0 to 60 C UL File No. E234324, VDE 13051.0-02 13051.0-03 13059.9-00 13059.9-02 950 W 950 W 950 W 950 W AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz 65 %RH, factory-set none (no integrated controls) 32 to 140 F none (no integrated controls) UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324 UL File No. E234324 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CR130/11-12/US 30 2.6" (67 mm) 5.6" (142 mm) CS/CSF 032 Compact PTC Fan Heater 1000 W Compact design High heating performance Double insulated plastic housing DIN or screw mount The compact CS 032 high performance fan heater prevents the formation of condensation and provides an evenly distributed interior air temperature in enclosures. The plastic housing provides protection against contact with current-carrying components via double insulation (protection class II). The fan heater is also available with an optional fixed-point thermostat as the CSF 032. These series were designed to accommodate DIN rail or screw mounting. CS 032 Fan Heater Heating Optional integrated fixed thermostat | Technical Data Heating element PTC resistor - temperature limiting Overheat protection built-in temperature limiter Surface temperature max. 176 F (80 C), except upper protective grill at 68 F (20 C) ambient temperature CSF 032 Fan Heater with Integrated Thermostat Air outlet temperature max. 257 F (125 C), 2" (50 mm) above grill Axial fan, ball bearing service life 70,000 h at 77 F (25 C) Air flow, free blowing 37 cfm (63 m/h) Connection male power insert connector according to IEC320 C18 Fuse 10 A time lag (T) integrated Housing plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715, or Heating Power (W) screw mount (M5, not included), tightening torque 2 Nm max. Mounting position -40 C -40 F -20 C -4 F 0 C 32 F 20 C 68 F 40 C 104 F Ambient Temperature air flow directed up Operating temperature -40 to +140 F (-40 to +60 C) Storage temperature -40 to +158 F (-40 to +70 C) Dimensions 5.9 x 3.5 x 2.6" (150.5 x 88 x 66 mm) Weight approx. 16.5 oz. (650 g) Protection class II (double insulated) Protection type IP20 Approvals UL File No. 234324, VDE Important note: Connectors and cables for electrical connection are not included with the heater. Part No. DIN rail mount Part No. Screw mount 03200.0-00 03200.0-01 03200.9-00 03200.9-01 03201.0-00 03201.0-01 03201.9-00 03201.9-01 03202.0-00 03202.0-01 03202.9-00 03202.9-01 1) at 77 F (25 C) ambient temperature 2) tolerance Series Operating voltage Heating capacity1) Max. current (inrush) Switch-off temperature2) Switch-on temperature2) CS 032, no thermostat CS 032, no thermostat CSF 032, with thermostat CSF 032, with thermostat CSF 032, with thermostat CSF 032, with thermostat AC 220-240 V, 50/60 Hz AC 100-120 V, 50/60 Hz AC 220-240 V, 50/60 Hz AC 100-120 V, 50/60 Hz AC 220-240 V, 50/60 Hz AC 100-120 V, 50/60 Hz 1000 W 1000 W 1000 W 1000 W 1000 W 1000 W 12 A 18 A 12 A 18 A 12 A 18 A 59 F (15 C) 77 F (25 C) 59 F (15 C) 77 F (25 C) 41 F (5 C) 59 F (15 C) 41 F (5 C) 59 F (15 C) of 5 K Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CS032/11-12/US Connection cables are available as accessories (see next page). CS/CSF 032 Compact PTC Fan Heater Accessories Dimensional drawing Lighting View: back side Accessories Connection cable with female power insert connector according to IEC320 C17 Part No. 244379 244380 Length 1.0 m 2.0 m Retaining Clip CS032A/11-12/US Photo: Retaining clip, Part No. 237009 Part No. 237009 Note Suitable for female power insert connection cable 244379 and 244380 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CS 030 Foot-mount PTC Fan Heater 1200 W Compact design Built-in overheat protection Integrated adjustable thermostat (optional) The compact CS 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an optional integrated thermostat for temperature control. The CS 030 was designed as a stationary unit for the bottom of the enclosure. For panel or DIN rail mount, the CS 130 fan heater is recommended. Heating Double insulated plastic housing | Technical Data N N L L Heating element PTC resistor - temperature limiting Overheat protection built-in temperature limiter Axial fan, ball bearing service life 50,000 h at 77 F (25 C) Air flow, free blowing 94 cfm (160 m/h) Connection 2-pole terminal AWG 14 max. (2.5 mm) with strain relief, clamping torque 0.8 Nm max. M Wiring diagram Housing plastic, UL 94V-0, black Mounting M5 screws (not included) Mounting position horizontal Operating / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 4.7 x 5.7 x 6.6" (120 x 145 x 168 mm) Weight approx. 2.6 lbs. (1.2 kg) Protection class II (double insulated) Protection type IP20 Heating Power (W) 6.6" (168 mm) 4.7" (120 mm) 30 Part No. 03060.0-00 03060.0-01 03060.9-00 03060.9-01 1) at -40 C -40 F Heating capacity1) 1200 W 1200 W 1200 W 1200 W -20 C -4 F 0 C 32 F 20 C 68 F 40 C 104 F Ambient Temperature Operating voltage AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz Max. current (inrush) 13.0 A 13.0 A 16.0 A 16.0 A Setting range 0 to 60 C none (no integrated controls) 32 to 140 F none (no integrated controls) Approvals UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324 UL File No. E234324 68 F (20 C) ambient temperature Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CS030/11-12/US 5.7" (145 mm) 5.1" (130 mm) 4.1" (105 mm) CS 130 Panel-mount PTC Fan Heater 1200 W Compact design Built-in overheat protection Integrated adjustable thermostat (optional) Double insulated plastic housing The compact CS 130 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures. This fan heater is available with an optional integrated thermostat for temperature control. The CS 130 was designed as a stationary unit for panel or DIN rail mounting. For foot mounting on the bottom of an enclosure, the CS 030 fan heater is recommended. Heating Panel or DIN rail mounting | Technical Data L L built-in temperature limiter Axial fan, ball bearing service life 50,000 h at 77 F (25 C) Air flow, free blowing 94 cfm (160 m/h) Connection 2-pole terminal AWG 14 max. (2.5 mm) with strain relief, clamping torque 0.8 Nm max. M plastic, UL 94V-0, black Mounting clip for 35 mm DIN rail, EN 60715 or M6 screws (not included) Mounting position horizontal Operating / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 4.7 x 6.3 x 7.2" (120 x 160 x 182 mm) Weight approx. 2.6 lbs. (1.2 kg) Protection class II (double insulated) Protection type IP20 6.3" (160 mm) Wiring diagram Housing 7.2" (182 mm) Part No. 13060.0-00 13060.0-01 13060.9-00 13060.9-01 1) at -40 C -40 F 4.7" (120 mm) 30 2.6" (67 mm) 5.6" (142 mm) Heating capacity1) 1200 W 1200 W 1200 W 1200 W -20 C -4 F 0 C 32 F 20 C 68 F 40 C 104 F Ambient Temperature Operating voltage AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 120 V, 50/60 Hz Max. current (inrush) 13.0 A 13.0 A 16.0 A 16.0 A Setting range 0 to 60 C none (no integrated controls) 32 to 140 F none (no integrated controls) Approvals UL File No. E234324, VDE UL File No. E234324, VDE UL File No. E234324 UL File No. E234324 68 F (20 C) ambient temperature Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CS130/11-12/US N PTC resistor - temperature limiting Overheat protection Heating Power (W) N Heating element CREx 020 Explosion-proof Heater 50 & 100 W Large convection surface Maintenance free The CREx 020 convection heaters are used in areas with explosion hazard to maintain minimum operating temperatures to help prevent failure of electronic components caused by condensation and corrosion. Heating DIN rail mountable | Technical Data Explosion protection according to EN LCIE (Laboratoire Central des Industries Electriques) Conformity certificate 01 ATEX 6073/03, LCIE N06 ATEX Q8011, IECEx LCI 07. 0021 Heating element high performance cartridge Heater body aluminum profile, black anodized Connection Si HF - JZ 3 x AWG 18 (0.75 mm), length 3.3 ft (1 m) Connection PE 4 mm Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to +70 C) Protection class I (grounded) Protection type IP65 4.65" (118 mm) DIN clip can alternatively be mounted to other side Ne pas ouvrir sous tension. Attendre 15 min. avant ouverture. Nicht unter Spannung offnen. Vor offnen 15 min. warten. Do not open while energized. Wait 15 min. before opening. Type: CREx 050W EEx d IIC T5 AC 230-240V / 50W Art. Nr. 02010.0-00 L.C.I.E. 98.E 6110 Serial No.: 5.9 / 7.1" (150 / 180 mm) 2.7" (69 mm) Part No. 02010.0-00 02010.0-01 02011.0-00 02011.0-01 Operating voltage AC 230-240 V AC 110-120 V AC 230-240 V AC 110-120 V Heating capacity 50 W 50 W 100 W 100 W Ex protection type d IIC T5 - Ex tD A21 IP6x T100C d IIC T5 - Ex tD A21 IP6x T100C d IIC T4 - Ex tD A21 IP6x T100C d IIC T4 - Ex tD A21 IP6x T100C Surface temperature 212 F (100 C) 212 F (100 C) 275 F (135 C) 275 F (135 C) Length (L) 5.9" (150 mm) 5.9" (150 mm) 7.1" (180 mm) 7.1" (180 mm) Weight (approx.) 2.9 lbs. (1.3 kg) 2.9 lbs. (1.3 kg) 3.3 lbs. (1.5 kg) 3.3 lbs. (1.5 kg) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com CREx020/11-12/US France S.A. FF 018 Filter Fan 14 - 69 cfm Very low noise Minimal mounting depth Functional design Time-saving installation Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channeling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localized heat pockets and protects the electronic components from overheating. The plastic used for the hood of this filter fan series is highly weather resistant, as well as impact and UV light resistant. Ventilating Weather and UV resistant | Technical Data Axial fan, ball bearing service life min. 50,000 h at 77 F (25 C) and 65 %RH aluminum fan body, plastic rotor Connection 2 wires w/cage clamps, AWG 14 (2.5 mm), length 4" (100 mm) Housing (filter fan and exhaust filter) Plastic, UL 94V-0, light grey Hood (filter fan and exhaust filter) Plastic, UL 94V-0, light grey; weather and UV light resistant according to UL 746C (f1) Mounting frame with double-sided industrial adhesive for mounting to the outside of enclosure; certain operating circumstances may make the additional use of screws necessary; cut-out template included Filter media rating G4 acc. to DIN EN 779, filtering degree 94 % Filter material synthetic fiber with progressive construction, temperature resistant to 212 F, self-extinguishing class F1; moisture resistant to 100 %RH, reusable - can be cleaned by washing or vacuuming Enclosure ventilation using a filter fan and exhaust filter Operating / Storage temperature +14 to +158 F (-10 to +70 C) / -40 to +158 F (-40 to 70 C) Protection class I (grounded) Protection type IP55 (according to VDE), UL Type 1 Note: Using fine filter mat F5 increases the protection to UL Type 12 but reduces the air flow Special features The self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet. Functional design of the intake and exhaust fan hoods very effectively prevents direct infiltration of falling water and dust. The advantage is that the filter mat does not rapidly become contaminated with dirt and therefore does not need to be exchanged as often. The air channeling makes the filter fan particularly quiet in operation. All filter fan models are also available with integrated airflow monitor. The direction of air flow can easily be switched by reversing the axial fan. EMC versions and other voltages are available upon request. Mounting depth Enclosure cut-out 01800.0-00 AC 230 V, 5 0Hz1) 12 cfm (21 m/h ) Air volume Power Average noise level with exhaust filter consumption (DIN EN ISO 4871) 9 cfm (16 m/h) 13 W 31 dB (A) 1.8" (45 mm) 3.8 x 3.8" 1.3 lbs. (0.6 kg) UL File No. E234324, VDE 01800.0-01 AC 120 V, 60 Hz 14 cfm (24 m/h) 11 cfm (18 m/h) 13 W 31 dB (A) 1.8" (45 mm) 3.8 x 3.8" 1.3 lbs. (0.6 kg) 01801.0-00 AC 230 V, 5 0Hz1) 32 cfm (55 m/h) 25 cfm (42 m/h) 15 W 40 dB (A) 2.3" (58 mm) 4.9 x 4.9" 2.2 lbs. (1.0 kg) UL File No. E234324, VDE 01801.0-01 AC 120 V, 60 Hz 1) Operating voltage Air volume, free blowing Weight (approx.) Approvals UL File No. E234324 37 cfm (63 m/h) 28 cfm (48 m/h) 15 W 40 dB (A) 2.3" (58 mm) 4.9 x 4.9" 2.2 lbs. (1.0 kg) 01802.0-00 AC 230 V, 5 0Hz1) 60 cfm (102 m/h) 40 cfm (68 m/h) 15 W 39 dB (A) 3.4" (86 mm) 6.9 x 6.9" 2.9 lbs. (1.3 kg) UL File No. E234324, VDE 01802.0-01 AC 120 V, 60 Hz 46 cfm (78 m/h) 15 W 39 dB (A) 3.4" (86 mm) 6.9 x 6.9" 2.9 lbs. (1.3 kg) 69 cfm (117 m/h) UL File No. E234324 UL File No. E234324 air volume increases by 15% when operating AC 230 V filter fans at 60 Hz Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FF018/11-12/US Part No. FF 018 Filter Fan 14 - 69 cfm Time-saving assembly and maintenance STEGO's filter fans are easily installed by one person from outside the cabinet. 1.) Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, filings and grease. A template for the enclosure cut-out is included with the filter fan. Ventilating 2.) Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays permanently in the cabinet. 3.) Electrically connect the axial fan using the cage clamp connectors. Push the unit into the mounting frame. Affix using screws if necessary. 4.) Insert the filter mat in the hood. Clip on. Finished. Installation sketch To change the filter mat, simply remove the filter hood, insert the new mat and snap the hood back again. No tools are required. Maintenance of the fan can easily be performed without removing the mounting frame (2). Dimensional Drawing 8.2" 3.4" 8.9" 6.7" 4.9" 5.3" 2.0" 6.2" 6.9" 1.6" 2.3" 5.1" 3.8" 1.4" 1.8" Drilling template for mounting frame O1/8" (3mm) O1/8" (3mm) 7.4" (188 mm) 5.4" (137 mm) 4.3" (109 mm) 7.4" (188 mm) 5.4" (137 mm) 4.3" (109 mm) O1/8" (3mm) EF 118 Exhaust Filter Part No. 11800.0-00 11801.0-00 11802.0-00 Mounting depth 0.6" (16 mm) 0.6" (16 mm) 0.6" (16 mm) Enclosure cut-out 3.8 x 3.8" 4.9 x 4.9" 6.9 x 6.9" Weight (approx.) 0.6 lbs. (0.3 kg) 0.8 lbs. (0.4 kg) 1.3 lbs. (0.6 kg) Filter mat G4 acc. to DIN EN 779, filtering degree 94 % G4 acc. to DIN EN 779, filtering degree 94 % G4 acc. to DIN EN 779, filtering degree 94 % Protection type IP55* IP55* IP55* Approvals UL File No. E234324 UL File No. E234324 UL File No. E234324 FF018/11-12/US *according to VDE FM 086 Filter Mats Filter mat G4 (1 packing unit = 3 pcs.) F5 (1 packing unit = 3 pcs.) 3.5 x 3.5" (89 x 89 mm) Part No. 08600.0-00 Part No. 08603.0-00 4.6 x 4.6" (118 x 118 mm) Part No. 08601.0-00 Part No. 08604.0-00 6.6 x 6.6" (168 x 168 mm) Part No. 08602.0-00 Part No. 08605.0-00 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FF 018 Filter Fan 136 cfm High air volume Functional design Time-saving installation 2.0" 3.7" (95 mm)(50 mm) 8.2" (209 mm) | 6.8" (172 mm) 8.9" (226 mm) Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channeling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localized heat pockets and protects the electronic components from overheating. The plastic used for the hood of this filter fan series is highly weather resistant, as well as impact and UV light resistant. Ventilating Weather and UV resistant Technical Data Axial fan, ball bearing service life min. 50,000 h at 77 F (25 C) and 65 %RH aluminum fan body, metal rotor 2.0" (50 mm) 3-pole term., AWG 14 (2.5 mm), clamping torque 0.8 Nm max. Housing (filter fan and exhaust filter) Plastic, UL 94V-0, light grey Hood (filter fan and exhaust filter) Plastic, UL 94V-0, light grey; weather and UV light resistant according to UL 746C (f1) 6.8" (172 mm) Filter Fan Connection Mounting frame with double-sided industrial adhesive for mounting to the outside of enclosure; certain operating circumstances may make the additional use of screws necessary; cut-out template included Exhaust Filter View from rear Filter media rating G4 acc. to DIN EN 779, filtering degree 94 % Filter material synthetic fiber with progressive construction, temperature resistant to 212 F, self-extinguishing class F1; 7.4" (188 mm) moisture resistant to 100 %RH, reusable - can be cleaned by 7.4" (188 mm) washing or vacuuming O1/8" (3 mm) Operating / Storage temperature -13 to +140 F (-25 to +60 C) Protection class I (grounded) Protection type IP55 (according to VDE), UL Type 1 Note: Using fine filter mat F5 increases the protection to UL Type 12 but reduces the air flow Drilling template for mounting frame FF 018 Filter Fan Part No. Operating voltage Air volume, free blowing 01804.0-00 AC 230 V, 50 Hz1) 118 cfm (200 m/h) 01804.0-01 AC 120 V, 60 Hz 136 cfm (230 m/h) 1) Power Average noise level Air volume with exhaust filter consumption (DIN EN ISO 4871) 74 cfm (125 m/h) 84 cfm (143 m/h) 45 W 39 W 52 dB (A) 52 dB (A) Mounting depth Enclosure cut-out 3.7" (95 mm) 3.7" (95 mm) 6.9 x 6.9" 6.9 x 6.9" Weight (approx.) Approvals 3.7 lbs. (1.7 kg) UL File No. E234324 3.7 lbs. (1.7 kg) UL File No. E234324 air volume increases by 15% when operating AC 230 V filter fans at 60 Hz EF 118 Exhaust Filter Part. No. 11802.0-00 Mounting depth 0.6" (16 mm) Enclosure cut-out 6.9 x 6.9" Weight (approx.) 1.3 lbs. (0.6 kg) Filter mat G4 acc. to DIN EN 779, filtering degree 94 % Protection type IP55* Approvals UL File No. E234324 FM 086 Filter Mats Filter mat G4 (1 packing unit = 3 pcs.) F5 (1 packing unit = 3 pcs.) 6.6 x 6.6" (168 x 168 mm) Part No. 08602.0-00 Part No. 08605.0-00 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FF018-136/11-12/US *according to VDE FF 018 Filter Fan 202 cfm Minimal mounting depth High air volume Functional design Time-saving installation 1.8" 2.6" (65 mm) (45 mm) 9.8" (250 mm) 11.2" (284 mm) Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channeling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localized heat pockets and protects the electronic components from overheating. Four integrated axial fans provide a particularly high and uniform air circulation which contributes to higher reliability. The plastic used for the hood of this filter fan series is highly weather and UV light resistant. Ventilating Weather and UV resistant | Technical Data Axial fan, ball bearing Filter fan service life min. 50,000 h at 77 F (25 C) and 65 %RH 1.8" 0.9" (22 mm) (45 mm) aluminum fan body, plastic rotor Connection 3-pole term., AWG 14 (2.5 mm), clamping torque 0.8 Nm max. Housing (filter fan and exhaust filter) Plastic, UL 94V-0, light grey Hood (filter fan and exhaust filter) Plastic, UL 94V-0, light grey; weather and UV light resistant according to UL 746C (f1) 9.8" (250 mm) 4 axial fans Mounting frame with double-sided industrial adhesive for mounting to the outside of enclosure; certain operating circumstances may make the additional use of screws necessary; cut-out template included View from rear Exhaust filter 10.4" (263 mm) Filter media rating G4 acc. to DIN EN 779, filtering degree 94 % Filter material synthetic fiber with progressive construction, temperature resistant to 212 F, self-extinguishing class F1; moisture resistant to 100 %RH, reusable - can be cleaned by 10.4" (263 mm) Drilling template for mounting frame O1/8" (3 mm) washing or vacuuming Operating / Storage temperature +14 to +158 F (-10 to +70 C) / -40 to +158 F (-40 to +70 C) Protection class I (grounded) Protection type IP55 (according to VDE), UL Type 1 Note: Using fine filter mat F5 increases the protection to UL Type 12 but reduces the air flow FF 018 Filter Fan Part No. Operating voltage Air volume, free blowing Power Average noise level Air volume with exhaust filter consumption (DIN EN ISO 4871) 01803.0-00 AC 230 V, 50 Hz1) 177 cfm (300 m/h) 135 cfm (230 m/h) 01803.0-01 AC 120 V, 60 Hz 202 cfm (345 m/h) 155 cfm (264 m/h) 1) 60 W 60 W 53 dB (A) 53 dB (A) Mounting depth Enclosure cut-out Weight (approx.) Approvals 2.6" (65 mm) 2.6" (65 mm) 9.8 x 9.8" 9.8 x 9.8" 7.3 lbs. (3.3 kg) 7.3 lbs. (3.3 kg) UL File No. E234324 UL File No. E234324 air volume increases by 15% when operating AC 230 V filter fans at 60 Hz EF 118 Exhaust Filter Mounting depth 0.9" (22 mm) Enclosure cut-out 9.8 x 9.8" Weight (approx.) 2.2 lbs. (1.0 kg) Filter mat G4 acc. to DIN EN 779, filtering degree 94 % Protection type IP55* *according to VDE FM 086 Filter Mats Filter mat G4 (1 packing unit = 3 pcs.) F5 (1 packing unit = 3 pcs.) 9.7 x 9.7" (247 x 247 mm) Part No. 08608.0-00 Part No. 08609.0-00 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FF018-202/11-12/US Part. No. 11803.0-00 FF 018 Filter Fan 373 cfm High air volume Functional design Time-saving installation Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channeling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localized heat pockets and protects the electronic components from overheating. The plastic used for the hood of this filter fan series is highly weather and UV light resistant. | 1.8" 4.2" (107 mm) (45 mm) 11.2" (284 mm) Ventilating Weather and UV resistant 9.8" (250 mm) Technical Data Axial fan, ball bearing service life min. 50,000 h at 77 F (25 C) and 65 %RH aluminum fan body, metal rotor Filter fan 1.8" 0.9" (22 mm) (45 mm) Connection 3-pole term., AWG 14 (2.5 mm), clamping torque 0.8 Nm max. Housing (filter fan and exhaust filter) Plastic, UL 94V-0, light grey Hood (filter fan and exhaust filter) Plastic, UL 94V-0, light grey; weather and UV light resistant according to UL 746C (f1) Mounting frame with double-sided industrial adhesive for mounting to the 9.8" (250 mm) outside of enclosure; certain operating circumstances may make the additional use of screws necessary; cut-out template included Filter media rating G4 acc. to DIN EN 779, filtering degree 94 % Filter material synthetic fiber with progressive construction, temperature Exhaust filter View from rear resistant to 212 F, self-extinguishing class F1; moisture resistant to 100 %RH, reusable - can be cleaned by 10.4" (263 mm) 10.4" (263 mm) washing or vacuuming O1/8" (3 mm) Operating / Storage temperature -13 to +158 F (-25 to +70 C) Protection class I (grounded) Protection type IP55 (according to VDE), UL Type 1 Note: Using fine filter mat F5 increases the protection to UL Type 12 but reduces the air flow Drilling template for mounting frame FF 018 Filter Fan Part No. Operating voltage Air volume, free blowing Power Average noise level Air volume with exhaust filter consumption (DIN EN ISO 4871) 01805.0-00 AC 230 V, 50 Hz1) 324 cfm (550 m/h) 177 cfm (300 m/h) 01805.0-01 AC 120 V, 60 Hz 373 cfm (633 m/h) 203 cfm (345 m/h) 1) 64 W 85 W 52 dB (A) 52 dB (A) Mounting depth Enclosure cut-out 4.2" (107 mm) 4.2" (107 mm) 9.8 x 9.8" 9.8 x 9.8" Weight (approx.) Approvals 5.9 lbs. (2.7 kg) UL File No. E234324 5.9 lbs. (2.7 kg) UL File No. E234324 air volume increases by 15% when operating AC 230 V filter fans at 60 Hz EF 118 Exhaust Filter Part. No. 11803.0-00 Mounting depth 0.9" (22 mm) Enclosure cut-out 9.8 x 9.8" Weight (approx.) 2.2 lbs. (1.0 kg) Filter mat G4 acc. to DIN EN 779, filtering degree 94 % Protection type IP55* FM 086 Filter Mats Filter mat G4 (1 packing unit = 3 pcs.) F5 (1 packing unit = 3 pcs.) 9.7 x 9.7" (247 x 247 mm) Part No. 08608.0-00 Part No. 08609.0-00 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FF018-371/11-12/US *according to VDE FF 01821 Outdoor Filter Fan 14 cfm Quick and easy filter change Lockable outer door Impact resistant This filter fan can be used in outdoor enclosures where warm air has to be dissipated. To clean and exchange the filter mat, it is only necessary to open the lockable door of the outdoor hood eliminating the need to allow interior access to the enclosure. A protection type of IP55 is achieved due to the special design of the hood and the use of fine filter mats. The plastic used for the hood of this filter fan is highly weather and UV light resistant. Ventilating Weather and UV resistant Outdoor Filter Fan 6.5" (165 mm) | 8.8" (224 mm) 4.9" (125 mm) 2.4" (62 mm) 2.6" (65 mm) Technical Data Axial fan, ball bearing service life min. 50,000 h at 77 F (25 C) and 65 %RH aluminum fan body, plastic rotor 0.7" (18 mm) 5.6" (142 +0.2mm) Connection 2 wires w/cage clamps, AWG 14 (2.5 mm), length 4" (100 mm) Filter fan and exhaust filter housing high impact ASA plastic, light grey burning behavior according to UL 94H-B; high resistance to weather and UV light 7.3" (185 +0.2mm) Mounting frame with double-sided industrial adhesive for mounting to the outside of enclosure; certain operating circumstances may make the additional use of screws necessary; cut-out template included View from rear Outdoor Exhaust Filter Filter media rating F5 acc. to DIN EN 779, filtering degree 98 % Filter material synthetic fiber with progressive construction, temperature resistant to 212 F, self-extinguishing class F1; 5.4" (137 mm) moisture resistant to 100 %RH 5.4" (137 mm) Drilling template for mounting frame Operating / Storage temperature +14 to +158 F (-10 to +70 C) / -40 to +158 F (-40 to +70 C) Protection class I (grounded) Protection type IP55 Note: EMC version and other voltages are available upon request O0.12" (3 mm) The hood is attached permanently to the enclosure from the inside using provided screws. Filter mats can be easily changed from outside the enclosure through the lockable door in the hood. FF 01821 Outdoor Filter Fan 1) Part No. Operating voltage Air volume, free blowing Power consumption Average noise level (DIN EN ISO 4871) Mounting depth Enclosure cut-out Weight (approx.) Approvals 01821.0-00 01821.0-02 AC 230 V, 50 Hz1) AC 120 V, 60 Hz 12 cfm (20 m/h) 14 cfm (23 m/h) 15 W 15 W 40 dB (A) 40 dB (A) 2.4" (62 mm) 2.4" (62 mm) 4.9 x 4.9" 4.9 x 4.9" 2.6 lbs. (1.2 kg) 2.6 lbs. (1.2 kg) UL File No. E234324 UL File No. E234324 air volume increases by 15% when operating AC 230 V filter fans at 60 Hz Part No. 11821.0-00 Mounting depth 0.6" (16 mm) Enclosure cut-out 4.9 x 4.9" Weight (approx.) 1.6 lbs. (0.6 kg) Filter mat F5 acc. to DIN EN 779, filtering degree 98 % Protection type IP55 FFM 086 Filter Mats Filter mat F5 (1 packing unit = 3 pcs.) 4.6 x 4.6" (118 x 118 mm) Part No. 08604.0-00 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com FF01821/11-12/US EF 11821 Exhaust Filter RFP 018 Roof Filter Fan 177 - 338 cfm Very low noise Minimal mounting depth High air volume High reliability Roof filter fans and roof exhaust filters are used in enclosures from which warm air must be diverted due to increased heat development. The ready-to-connect and low-noise roof filter fan is used to expel warm air from within the enclosure. Alternatively, the roof exhaust filter provides passive ventilation. The RFP 018 series comes in two versions: one utilizes four small axial fans, improving reliability and maintaining continuous operations even if one of the fans should fail; the second uses a larger single high capacity fan. Ventilating Time-saving installation | Technical Data Axial fans, ball bearing 2.0" 2.9" (52 mm) (73 mm) 13.9" (354 mm) service life min. 50,000 h at 77 F (25 C) and 65 %RH aluminum fan body, plastic rotor Connection 3-pole term., AWG 14 (2.5 mm), clamping torque 0.8 Nm max. Housing Plastic, UL 94V-0, light grey; 9.8" (250 mm) weather and UV light resistant according to UL 746C (f1) Filter mat G3 acc. to DIN EN 779, filtering degree 85 % Filter material synthetic fiber with progressive construction, temperature resistant to 212 F, self-extinguishing class F1; moisture resistant to 100 %RH, reusable - can be cleaned by washing or vacuuming 4.2" 2.9" (107 mm) (73 mm) 13.9" (354 mm) Operating / Storage temperature dependent on fan type Protection class I (grounded) Protection type IP32 Approvals VDE (230V only) Important note: For reasons of pressure compensation, the roof filter fan must always be operated in combi- Hole centers Roof Exhaust Filter 10.1" (256 mm) 9.8" (250 mm) nation with another filter fan (e.g. Part No. 01803.0-00) or a passive intake filter (e.g. Part No. 11803.0-00). 2.9" (73 mm) 0.4" (11 mm) O0.12" (3 mm) 9.8" (250 mm) RFP 018 Roof Filter Fan 01860.0-00 Operating voltage AC 230 V, 50 Hz1) 01860.0-02 01861.0-00 01861.0-02 AC 120 V, 60 Hz AC 230 V, 50 Hz1) AC 120 V, 60 Hz Part No. 1) Enclosure cut out Use included template for precise cut-out dimensions 177 cfm (300 m/h) - 4 fans Power consumption 68 W Average noise level (DIN EN ISO 4871) 55 db (A) 203 cfm (345 m/h) - 1 fan 294 cfm (500 m/h) - 4 fans 338 cfm (575 m/h) - 1 fan 60 W 64 W 85 W 55 db (A) 67 db (A) 67 db (A) Air volume, free blowing (w/ G3 filter mat) 9.8" (250 mm) 2.0" (52 mm) Enclosure cut-out 9.8 x 9.8" Weight (approx.) 7.3 lbs. (3.3 kg) 2.0" (52 mm) 4.2" (107 mm) 4.2" (107 mm) 9.8 x 9.8" 9.8 x 9.8" 9.8 x 9.8" 5.7 lbs. (2.6 kg) 7.3 lbs. (3.3 kg) 5.7 lbs. (2.6 kg) Mounting depth air volume increases by 15% when operating AC 230 V filter fans at 60 Hz Part No. 11860.0-00 Mounting depth 0.43" (11 mm) Enclosure cut-out 9.8 x 9.8" Weight (approx.) 2.2 lbs. (1.0 kg) Filter mat G3 acc. to DIN EN 779, filtering degree 85 % Protection type IP32 FM 086 Filter Mats Filter mat G3 (1 packing unit = 3 pcs.) 11.1 x 11.1" (282 x 282 mm) Part No. 08613.0-01 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com RFF018/11-12/US REP 118 Roof Exhaust Filter LE 019 19" Fan Tray 286 - 1017 cfm High air volume Long service life Easy installation and connection Function control light The LE 019 is a compact high performance fan tray for forced circulation of air in enclosures and for cooling of 19" rack mount applications. Natural convection is improved and the formation of hot zones is prevented. Also available with integrated thermostat (see photo). 1.25" (31.8 mm) 1.7" (43.6 mm) 18.3" (465.1 mm) Ventilating Optional integrated thermostat 16.9" (430 mm) 8.2" (208 mm) | Technical Data Axial fans, ball bearing service life 50,000 h at 77 F (25 C) and 65 %RH fan body aluminium, rotor plastic Material 19" (482.6 mm) front panel aluminium, bright anodised 13" (330 mm) casing steel sheet, electrogalvanized Optical indicator integrated in front panel Connection power inlet on rear of casing, plug included (no cable) Mounting position horizontal (direction of air upward) Operating / Storage temperature -4 to +158 F (-20 to +70 C) Protection type IP20 Protection class I (grounded) Approvals UL File No. E234324 Note The use of a thermostat, whether integrated or external, is recommended. When using a fan tray with integrated thermostat, an additional thermostat (e.g. KT 011 Part No. 01141.9-00) 17.8" (452 mm) may be used if it is desired to switch a signal device should the enclosure interior temperature rise above a set limit (e.g. in case of fan failure). For models without integrated thermostat, the use of a dual thermostat (e.g. ZR 011 Part No. 01176.0-00) provides the same overheat protection, i.e. one thermostat to control the fan tray operation, one thermostat for a signal device. 1) Model No. of Operating fans voltage 3 AC 230 V, 50 Hz1) Air flow, free blowing 286 cfm (486 m/h) Power Average noise level consumption (DIN EN ISO 4871) 45 W 55 db (A) Speed (rpm-1) 2600 min-1 (50 Hz) Static Weight (approx.) pressure 74 Pa 6.6 lbs. (3.0 kg) 01930.0-00 w/out thermostat 01930.1-00 01931.0-00 01931.1-00 01940.0-00 w/ thermostat (0 to 60C) w/out thermostat w/ thermostat (0 to 60C) w/out thermostat 3 3 3 6 AC 230 V, 50 Hz1) AC 120 V, 60 Hz AC 120 V, 60 Hz AC 230 V, 50 Hz1) 286 cfm (486 m/h) 339 cfm (576 m/h) 339 cfm (576 m/h) 572 cfm (972 m/h) 45 W 45 W 45 W 90 W 55 db (A) 55 db (A) 55 db (A) 57 db (A) 2600 min-1 (50 Hz) 2900 min-1 (60 Hz) 2900 min-1 (60 Hz) 2600 min-1 (50 Hz) 74 Pa 88 Pa 88 Pa 74 Pa 7.5 lbs. (3.4 kg) 6.6 lbs. (3.0 kg) 7.5 lbs. (3.4 kg) 11.7 lbs. (5.3 kg) 01940.1-00 w/ thermostat (0 to 60C) 6 AC 230 V, 50 Hz1) 572 cfm (972 m/h) 90 W 57 db (A) 2600 min-1 (50 Hz) 74 Pa 12.5 lbs. (5.7 kg) 01941.0-00 w/out thermostat 6 AC 120 V, 60 Hz 678 cfm (1152 m/h) 90 W 57 db (A) 2900 min-1 (60 Hz) 88 Pa 11.7 lbs. (5.3 kg) 01941.1-00 w/ thermostat (0 to 60C) 6 AC 120 V, 60 Hz 678 cfm (1152 m/h) 90 W 57 db (A) 2900 min-1 (60 Hz) 88 Pa 12.5 lbs. (5.7 kg) 01950.0-00 w/out thermostat 9 AC 230 V, 50 Hz1) 858 cfm (1458 m/h) 135 W 58 db (A) 2600 min-1 (50 Hz) 74 Pa 17.2 lbs. (7.8 kg) 01950.1-00 w/ thermostat (0 to 60C) 9 AC 230 V, 50 Hz1) 858 cfm (1458 m/h) 135 W 58 db (A) 2600 min-1 (50 Hz) 74 Pa 17.4 lbs. (7.9 kg) 01951.0-00 w/out thermostat 9 AC 120 V, 60 Hz 1017 cfm (1728 m/h) 135 W 58 db (A) 2900 min-1 (60 Hz) 88 Pa 17.2 lbs. (7.8 kg) 01951.1-00 w/ thermostat (0 to 60C) 9 AC 120 V, 60 Hz 1017 cfm (1728 m/h) 135 W 58 db (A) 2900 min-1 (60 Hz) 88 Pa 17.4 lbs. (7.9 kg) air volume increases by 15% when operating AC 230 V filter fans at 60 Hz Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com LE019/11-12/US Part No. DA 284 Vent Plug UL Type 1, 4, 4X & IP66 protection Waterproof membrane Easy to install Pressure differentials in a hermetically sealed enclosure are a result of the heat generated by electrical and electronic components in the enclosure, as well as the fluctuation of the outside temperature. In the case of negative pressure or vacuum, for example, dust and humidity can enter the enclosure through the door seal. The DA 284 Vent Plug provides a protected enclosure environment for valuable and crucial components with a UL 4X rated degree of protection. A waterproof membrane inside the device allows air and humidity to leave the enclosure. Conversely, it only allows dry air into the enclosure while not allowing humidity and dust from the outside to enter. Photo: DA 284, M40 Ventilating Two sizes - M40 & M12 Technical Data Mounting thread with nut (see below), torque 10 Nm max. Material plastic, PA66, light grey Sealing NBR gasket Filter waterproof membrane Operating / Storage temperature -49 to +158 F (-45 to 70 C) Protection type see below Agency approvals UL File No. E234324 Environmental rating Type 1, 4 and 4X Installation Make cut-out in enclosure wall of 1.58" (40 - 40.2 mm) for size M40 or 0.48" (12 - 12.2 mm) for size M12, and mount vent plug with nut. Make sure that the sealing gasket is placed on the outer side of the enclosure. For Photo: DA 284, M12 optimal pressure compensation, it is recommended to use two devices on opposite sides towards the top of the enclosure. 1) Protection type Air permeability1) 1 packing unit Weight (approx.) M40 x 1.5 Thread length (depth in enclosure) approx. 16 mm IP66 (EN 60529) / IPX9K (EN 40050-9) 1200 liters/hr 2 pieces 3.2 oz. (90 g) total M12 x 1.5 approx. 10 mm IP66 (EN 60529) 120 liters/hr 2 pieces 0.14 oz. (4 g) total Part No. Model 28405.0-00 28406.0-00 at a pressure difference of min. 70 mbar Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com DA284/11-12/US Dimensional drawing: DA 284, M12 (drawing is not proportional to M40) Dimensional drawing: DA 284, M40 DA 284S Stainless Steel Vent Plug High degree of protection (IP66) Semipermeable membrane Corrosion resistant Easy to install Pressure differentials in a hermetically sealed enclosure are a result of the heat generated by electrical and electronic components in the enclosure, as well as the fluctuation of the outside temperature. In the case of negative pressure or vacuum, for example, dust and humidity can enter the enclosure through the door seal. Ventilating Two sizes - M40 & M12 Photos: DA 284S, M40 The DA 284S Stainless Steel Vent Plug provides a protected enclosure environment for valuable and crucial components with an IP66 rated degree of protection. A waterproof membrane inside the device allows air and humidity to leave the enclosure. Conversely, it only allows dry air into the enclosure while not allowing humidity and dust from the outside to enter. Technical Data Mounting thread with nut, torque 10 Nm max. Material stainless steel V2A (DIN 1.4305 / AISI 303) Sealing NBR gasket Filter waterproof membrane Operating / Storage temperature -31 to +158 F (-35 to 70 C) Protection type see below Installation A hole with a diameter of 1.58" (40 - 40.2 mm) is required for installation. Make sure that the sealing gasket is placed on the outer side of the enclosure. For optimal pressure compensation, it is recommended to use two devices on opposite sides towards the top of the enclosure. 1.22" (31 mm) 0.79" (20 mm) M40 x 1.5 O1.57" (O40 mm) 2.28" (58 mm) 1) Part No. Model Thread length (depth in enclosure) Protection type Air permeability1) 1 packing unit Weight (approx.) 28401.0-00 M40 x 1.5 approx. 9 mm IP66 (EN 60529) / IPX9K (EN 40050-9) 1200 liters/hr 1 piece 5.6 oz. (160 g) 28402.0-01 M12 x 1.5 approx. 4 mm IP66 (EN 60529) 120 liters/hr 1 piece 0.6 oz. (17 g) at a pressure difference of min. 70 mbar Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com DA284S/11-12/US Dimensional drawing: DA 284S, M40 DA 084 Vent Plug High degree of protection (IP55) It has become increasingly important to provide a protected enclosure environment for valuable and crucial electrical and electronic components. In a tightly closed enclosure, pressure differentials can occur during extreme temperature variations, such as day/night operation. When this occurs, the risk of dust and humidity ingression into the control panel increases dramatically. The specially designed DA 084 vent plug permits a controlled change in pressure and can easily be installed in any enclosure. The vent plug is suitable for the use in enclosures and electrical cabinets in accordance with DIN EN 62208. Ventilating Easy to install Technical Data Mounting PG 29 thread with union nut, torque 10 Nm max. Mounting position vertical* Material plastic, UL 94V-0 Sealing NBR gasket Air Interface Approx. 2.8 in2 (7 cm2) Operating / Storage temperature -49 to +158 F (-45 to 70 C) Dimensions O 2.58" x 1.2" (O 65.5 x 30.5 mm) * Protection type is restricted to IP54 if mounting position is not vertical Installation A hole with a diameter of 1.46" (37 mm) is required for mounting. Make sure that the sealing gasket is placed on the outer side panel of the enclosure. For optimal pressure compensation, it is recommended to use two devices on opposite sides towards the top of the enclosures. 1.2" (30.5 mm) 0.61" (15.5 mm) Part No. 08400.9-01 Protection type IP55 1 packing unit 1 piece Weight (approx.) 1.1 oz. (31 g) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com DA084/11-12/US O1.46" (37 mm) 2.58" (65.6 mm) LED 025 Light Energy saving LED technology Wide voltage range LED 025 Light with magnet mount Integrated power unit Magnet or screw mount Wide variety of connections LED 025 Light with screw mount The LED 025 light series is suitable for all types of panels and enclosures, especially where space is at a premium. These lights have a very long service life due to the use of LED technology. They are available with powerful non-slip rubberized magnets allowing them to be easily positioned in any steel enclosure. Screw mounting is also available as an option. The power output allows up to 10 lights to be connected to each other (daisy chain) with both the input and output plugs snap-locking into place. Lighting On/off switch or motion sensor | Technical Data On/off switch light w/magnet mount Power consumption max. 5 W (~ 75 W incandescent bulb) Luminosity 290 Lm Lamp type LED, 120 angle of radiation light color - daylight, color temperature - 6,500 K Service life 60,000 hrs. at 68 F (20 C) Connection 2-pole plug with snap lock AC: max. 2.5 A / AC 240 V, white cable DC: max. 2.5 A / DC 60 V, blue cable Magnet mount end view Screw mount end view Housing plastic, transparent Mounting magnet or M5 screws (not included), 9.8" (250 mm) centers; screw torque 2 Nm max. Operating temperature -22 to +140 F (-30 to +60 C) Storage temperature -40 to +185 F (-40 to +85 C) Dimensions magnet mount - 13.8 x 1.3 x 1.3" (351 x 34 x 32 mm) screw mount - 13.8 x 1.4 x 1.3" (351 x 36 x 32 mm) Motion sensor light w/magnet mount Part No. - magnet mount 02540.0-00 02540.1-00 02541.0-00 02541.1-00 1) Passive II (double insulated) Protection type IP20 Accessories input and output plug, cable for supply or connection Approvals UL File No. E234324, VDE Note available with a 19" front panel Screw mount end view Part No. - screw mount 02540.0-01 02540.1-01 02541.0-01 02541.1-01 Operating voltage AC 100-240 V, 50/60 Hz (min. AC 90 V, max. AC 265 V) DC 24-48 V (min. DC 20 V, max. DC 60 V) AC 100-240 V, 50/60 Hz (min. AC 90 V, max. AC 265 V) DC 24-48 V (min. DC 20 V, max. DC 60 V) Switch type on/off switch on/off switch PIR motion sensor 1) PIR motion sensor 1) Weight 4.8 oz. (135 g) 4.8 oz. (135 g) 5.0 oz. (140 g) 5.0 oz. (140 g) Infrared (PIR) motion sensor is factory pre-set to turn the light off 6 minutes after all motion ceases Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com LED025/11-12/US Magnet mount end view Protection class LED 025 Light - Accessories Connection cable with input connector and wire leads 1 Photo: Connection cable, Part No. 244357 Lighting Part No. 244357 244361 Model connection cable 2 x AWG 16 with input connector connection cable 2 x AWG 16 with input connector Length 2.0 m 2.0 m Voltage AC DC Extension cable with 2 connectors for daisy chain (input & output) connection Color connector: white - cable: white connector: blue - cable: white Approvals UL, VDE UL, VDE 2 1 2 2 Connection example Photo: Connection cable, Part No. 244359 Part No. 244359 244363 Model extension cable 2 x AWG 16 with 2 connectors extension cable 2 x AWG 16 with 2 connectors Length 1.0 m 1.0 m Voltage AC DC Color connectors: white - cable: white connectors: blue - cable: white Approvals UL, VDE UL, VDE The lights are easily connected via quick connection plugs or extension cables -- up to 10 lights can be daisy-chained this way. The snap-lock connectors ensure a stable electrical connection even when subjected to vibration. Input / output connectors Photo: Input connector, Part No. 264057 Part No. 264057 264058 264059 264060 Photo: Output connector, Part No. 264058 Model input connector output connector input connector output connector Voltage AC AC DC DC Color white white blue blue Approvals UL, VDE UL, VDE UL, VDE UL, VDE Switch type on/off switch on/off switch PIR motion sensor 1) PIR motion sensor 1) Weight 4.8 oz. (135 g) 4.8 oz. (135 g) 5.0 oz. (140 g) 5.0 oz. (140 g) LED025A/11-12/US Light kit with input connector included Part No. - magnet mount 02540.0-00-0003 02540.1-00-0003 02541.0-00-0003 02541.1-00-0003 1) Passive Part No. - screw mount 02540.0-01-0003 02540.1-01-0003 02541.0-01-0003 02541.1-01-0003 Operating voltage AC 100-240 V, 50/60 Hz (min. AC 90 V, max. AC 265 V) DC 24-48 V (min. DC 20 V, max. DC 60 V) AC 100-240 V, 50/60 Hz (min. AC 90 V, max. AC 265 V) DC 24-48 V (min. DC 20 V, max. DC 60 V) Infrared (PIR) motion sensor is factory pre-set to turn the light off 6 minutes after all motion ceases Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com SL 025 Slimline Light Compact design Electronic ballast Optional integrated receptacle Screw or magnet mount Long-life energy saving lamp The SL 025 light was designed to fit in tight spaces in enclosures. It features an optional integrated receptacle so that electrical devices (e.g. power tools) can be easily plugged in when needed. The standard light can be screw mounted in a variety of positions, or the light can be fitted with an available magnet mount. The motion sensor version was designed to eliminate the need for a door switch. Lighting On/off switch or motion sensor | Magnet (optional) 13.6" (345 mm) 11 W (~ 75 W incandescent bulb) Luminosity 900 Lm Lamp type compact fluorescent, 2G7 base, electronic ballast Service life 10,000 hrs. Switch (for light only) on/off switch or PIR motion sensor1) Connection 3-pole terminal AWG 16 max. (1.5 mm) with strain relief only (cable not included), clamping torque 0.8Nm max. Housing plastic, UL 94V-0, light grey Mounting M5 screws (not included), 11.8" (300 mm) hole distance or optional attached magnet (see part nos. below) 1.6" (40mm) 3.6" (91mm) Power consumption Operating temperature -4 to +122 F (-20 to +50 C) Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 13.6 x 3.6 x 1.6" (345 x 91 x 40 mm) Weight approx. 0.9 lbs. (400 g), 1.3 lbs (600 g) with magnet Protection type IP20 Note DC 24-48 V available upon request The Passive Infrared (PIR) motion sensor detects the motion of the enclosure door being opened and automatically turns on the light. The sensor is factory pre-set to turn the light off 6 minutes after all motion ceases. The motion sensor does not detect movement through glass, allowing for installation in enclosures with glass doors. 1) Note: electrical cable not included Part No. with On/Off Switch 02520.0-00 02520.1-00 02521.0-00 02521.1-00 Part No. with Motion Sensor 02520.0-03 02520.1-03 02521.0-03 02521.1-03 Model Operating voltage without magnet with magnet without magnet with magnet AC 230 V, 50/60 Hz Germany/Russia AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz 02522.0-00 02522.0-03 without magnet AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz Germany/Russia France/Poland France/Poland Switzerland 02522.1-00 02522.1-03 with magnet AC 230 V, 50/60 Hz Switzerland 02523.0-00 02523.0-03 without magnet 02523.1-00 02523.1-03 with magnet AC 230 V, 50/60 Hz AC 230 V, 50/60 Hz 02524.0-01 02524.0-04 without magnet 02524.1-01 02524.1-04 with magnet 02527.0-00 02527.0-04 02527.1-00 02527.0-10 02527.1-10 Receptacle Rec. max. current 16 A 16 A 16 A 16 A Protection class Approvals I (grounded) I (grounded) I (grounded) I (grounded) VDE VDE VDE VDE 10 A I (grounded) VDE 10 A I (grounded) VDE UK/Ireland UK/Ireland 13 A I (grounded) VDE 13 A I (grounded) VDE AC 120 V, 50/60 Hz USA/Canada 15 A I (grounded) UL File No. E234324 AC 120 V, 50/60 Hz AC 230 V, 50/60 Hz USA/Canada none 15 A I (grounded) UL File No. E234324 without magnet - II (double insulated) UL File No. E234324, VDE 02527.1-04 with magnet AC 230 V, 50/60 Hz none - II (double insulated) UL File No. E234324, VDE 02527.0-12 without magnet AC 120 V, 50/60 Hz none - II (double insulated) UL File No. E234324 02527.1-12 with magnet AC 120 V, 50/60 Hz none - II (double insulated) UL File No. E234324 Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com SL025/11-12/US 11.8" (300 mm) 0.8" (20 mm) 0.5" (12.5 mm) Technical Data SL 025 19" Rack-mount Slimline Light Compact design Electronic ballast Optional integrated receptacle Long-life energy saving lamp This SL 025 light is suitable for 19" rack mounting, e.g. for keyboards. Because of the flat design of the light, only one rack unit in height ("1U") is needed. Additionally, it is fitted with a reflector which serves as a glare shield, thereby illuminating the area below the light only. Lighting On/off switch The light also features an optional integrated receptacle, allowing for the use of additional electrical devices, such as power tools. | 19" (483 mm) Technical Data 3.5" (88 mm) Power consumption 11 W (~ 75 W incandescent bulb) Luminosity 900 Lm Lamp type compact fluorescent, 2G7 base, electronic ballast Service life 10,000 hrs. Switch (for light only) on/off switch (PIR motion sensor also available) Connection 3-pole terminal AWG 16 max. (1.5 mm) with strain relief only (cable not included), clamping torque 0.8 Nm max. Housing plastic, UL 94V-0, light grey Mounting max. M6 screws (not included) Mounting bracket aluminum, with cable bushing Operating temperature -4 to +122 F (-20 to +50 C) Storage temperature -49 to +158 F (-45 to +70 C) Dimensions lamp - 13.6 x 3.6 x 1.6" (345 x 91 x 40 mm), total length - 19" Weight approx. 1.1 lbs. (500 g) Protection type IP20 Note DC 24-48 V available upon request 1.7" (44 mm) Part No. Operating voltage 02520.0-02 AC 230 V, 50/60 Hz 02521.0-02 Receptacle Receptacle max. current Protection class Approvals Germany/Russia 16.0 A I (grounded) VDE AC 230 V, 50/60 Hz France/Poland 16.0 A I (grounded) VDE 02522.0-02 AC 230 V, 50/60 Hz Switzerland 10.0 A I (grounded) VDE 02523.0-02 AC 230 V, 50/60 Hz UK/Ireland 13.0 A I (grounded) VDE 02524.0-05 AC 120 V, 50/60 Hz 15.0 A I (grounded) UL File No. E234324 02527.0-02 AC 230 V, 50/60 Hz none - II (double insulated) UL File No. E234324, VDE 02527.0-11 AC 120 V, 50/60 Hz none - II (double insulated) UL File No. E234324 USA/Canada Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com SL025-19/11-12/US Note: electrical cable not included KL 025 Compact Enclosure Light Magnet or DIN rail mounting Energy-saving lamp Integrated receptacle The compact KL 025 light was designed for use in industrial enclosures and control cabinets. A strong magnet allows simple and quick installation and flexibility for various mounting positions. The light also features an optional integrated receptacle so that electrical devices can easily be plugged in when needed. Lighting On/off switch | Technical Data Power consumption see table below Luminosity 900 Lm Lamp type compact fluorescent, G23 base, inductive ballast Service life 5,000 hrs. Switch on/off switch (for light only) Connection 3-pole terminal AWG 14 max. (2.5 mm) with strain relief only (cable not included), clamping torque 0.8 Nm max. Housing plastic, light grey Mounting magnet mounting or on 35 mm DIN rail, EN 60715 Operating temperature -4 to +122 F (-20 to +50 C) Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 13.98 x 2.56 x 2.76" (355 x 65 x 70 mm) Weight approx. 2.2 lbs (1.0 kg) Protection type IP20 Part No. 02500.0-14 02500.0-21 02505.9-02 Operating voltage AC 230 V, 60 Hz AC 120 V, 60 Hz AC 120 V, 60 Hz Receptacle Germany none USA/Canada Power consumption 11 W (~ 75 W incandescent bulb) 9 W (~ 60 W incandescent bulb) 9 W (~ 60 W incandescent bulb) Receptacle Max. Current 16 A 15 A Protection class I (grounded) II (double insulated) I (grounded) Approvals VDE - Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com KL025/11-12/US Drawing shows mounting on two 7 inch long pieces of 35mm DIN rail. DL 026 Dual Light Versatile - base lamp or hand lamp Long-life energy saving lamp On/off switch or motion sensor Lighting The DL 026 dual light is available with on/off switch or motion sensor (the motion sensor version was designed to eliminate the need for a door switch). The lamp is removable from its base and, with the use of an optional additional power cord, can be used as a hand lamp. This versatile light was also designed to include a variety of mounting options. | Technical Data Power consumption 20 W (~ 100 W incandescent bulb) Luminosity 1000 Lm Lamp type compact fluorescent, E27 base, electronic ballast Service life 10,000 hrs. Switch on/off push switch or PIR motion sensor1) Connection 6-pole terminal, AWG 14 max (2.5 mm) - torque 0.5 Nm max. for hard wiring of 1 light or 2 lights in parallel Light with on/off switch Light with motion sensor Note: electrical cable not included Housing plastic, UL 94V-0, light grey Standard mounting (included) screw mounting on 35 mm DIN rail or sheet metal Optional mounting with self-adhesive or magnet mounting plates (see below) Mounting position variable Operating temperature -4 to +122 F (-20 to +50 C) Storage temperature -49 to +158 F (-45 to +70 C) Weight approx. 1.3 lbs. (600 g) Protection class II (double insulated) Protection type IP20 Accessories see below The Passive Infrared (PIR) motion sensor detects the motion of the enclosure door being opened and automatically turns on the light. The sensor is factory pre-set to turn the light off 3 minutes after all motion ceases. The motion sensor does not detect movement through glass, allowing for installation in enclosures with glass doors. 2.6" (67 mm) 15.6" (396 mm) 1) (1) Standard screw mounting to DIN rail (2) 2 self-adhesive (Part No. 09515.0-00) or magnet (Part No. 09516.0-00) mounting plates Part No. 02600.0-00 02600.9-00 02601.0-00 02601.9-00 (3) Self-adhesive light holder with hook and 6 ft. power cord (AC 230 V - Part No. 03410.0-00, AC 120 V - Part No. 03411.0-00). By using the holder/power cord kit, the light can be used as a hand lamp. Operating voltage AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz Switch type on/off on/off motion sensor motion sensor Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com DL026/11-12/US 3.93" (100 mm) DL 026 Hand Lamp Long-life energy saving lamp Lighting Wall-mount lamp holder | Technical Data 20 W (~ 100 W incandescent bulb) Luminosity 1000 Lm Lamp type compact fluorescent, E27 base, electronic ballast Service life 10,000 hrs. Connection integrated power cable (6 ft.) with US or Euro plug Housing plastic, UL 94V-0, light grey Mounting screws or self-adhesive mounting plate (included) Mounting position variable Operating temperature -4 to +122 F (-20 to +50 C) Storage temperature -49 to +158 F (-45 to +70 C) Weight approx. 1.3 lbs. (600 g) Protection class II (double insulated) Protection type IP20 41 2.7" (68 mm) 13.3" (337 mm) Power consumption Part No. 02610.0-00 02610.9-00 Operating voltage AC 230 V, 50/60 Hz AC 120 V, 50/60 Hz Plug type Euro US Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com DL026HL/11-12/US 3.3" (84 mm) SD 035 Enclosure Receptacle Quick connections DIN rail mountable The DIN rail mounted electrical receptacle can be quickly fitted and connected in enclosures allowing the use of auxiliary products such as hand lamps and power tools. The unit is available with and without fuse, and in many world outlet standards. Electrical Receptacles Available with or without fuse Technical Data Connection 3 cage clamps for solid and stranded wire AWG 20-14 (0.5-2.5 mm) plastic, UL 94V-0, light grey Mounting clip for 35 mm DIN rail, EN 60715 Mounting position vertical Operating / Storage temperature -49 to +158 F (-45 to 70 C) Dimensions 3.6 x 2.4 x 1.9" (92 x 62 x 48 mm) Weight approx. 7.1 oz. (200 g) Protection class I (grounded) Protection type IP20 1.9" (48 mm) (1) 3.6" (92 mm) 2.4" (62 mm) Housing (2) FUSE (3) FUSE FUSE N N N (4) (5) (6) FUSE N FUSE N N N Part No. Operating Voltage max. Socket Model Nominal Current Approvals 03500.0-00 AC 250 V Germany/Russia (1) with fuse* 6.3 A - 03500.0-01 AC 250 V Germany/Russia (1) without fuse 16.0 A - 03501.0-00 AC 250 V France/Poland (2) with fuse* 6.3 A - 03501.0-01 AC 250 V France/Poland (2) without fuse 16.0 A - 03502.0-00 AC 250 V Switzerland (3) with fuse* 6.3 A - 03502.0-01 AC 250 V Switzerland (3) without fuse 10.0 A - 03503.0-00 AC 250 V UK/Ireland (4) with fuse* 6.3 A - 03503.0-01 AC 250 V UK/Ireland (4) without fuse 13.0 A - 03504.0-00 AC 125 V USA/Canada (5) with fuse* 6.3 A UL File No. E222026 03504.0-01 AC 125 V USA/Canada (5) without fuse 15.0 A UL File No. E222026 03505.0-00 AC 250 V Italy (6) with fuse* 6.3 A - 03505.0-01 AC 250 V Italy (6) without fuse 16.0 A - * fuse O 5 x 20 mm Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com SD035/11-12/US FUSE FUSE MA 086 Multi-purpose Protective Cover Variety of uses Locking door High impact resistance The access door on the multi-purpose protective cover is equipped with a lock enabling easy access while providing security from unauthorized persons. The cover utilizes a labyrinth seal for protection against dirt and moisture, and the unit is permanently attached to the enclosure from the inside. Accessories Weather and UV resistant Technical Data Application examples Housing 30 20 20 40 50 10 0 60 40 50 10 C High impact ASA plastic, light grey burning behavior according to UL 94H-B; 30 0 60 high resistance to weather and UV light 11 12 Protection for ventilation openings (i.e. pressure compensation) 23 24 Operating / Storage temperature -49 to +158 F (-45 to +70 C) Dimensions 8.8 x 6.5 x 2.6" (224 x 165 x 65 mm) Protection type IP20 As a cover for thermostats and regulators Bottom view 1 2 3 1 2 3 4 As a tamper-proof cover for electronic input devices Protection for electronic locks and security system keypads Protection for power outlets Cover and protection for data interfaces Part No. 08611.0-00 Weight approx. 0.9 lbs. (0.4 kg) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com MA086/11-12/US 4 5 6 7 8 9 * 0 # 5 1 2 3 4 5 STEGO FIX Self-adhesive Mounting Aid Because of its industrial grade self-adhesive it can be installed much easier and quicker than a conventional DIN rail, without the effort of hole drilling and screw mounting. This is especially practical for subsequent changes or additions in an already equipped enclosure. STEGOFIX can hold components up to 1.1 lbs in weight. Some of the many applications include the mounting of timing relays, series terminals, thermostats, cable channels and even small heaters. In addition, DIN rails can be mounted simply by using several STEGOFIX units. Accessories STEGOFIX is a small aid specially designed to make mounting of smaller DIN rail mountable components easier. It can be used whenever the installation of a DIN rail is impractical, or when there is not enough space left in an enclosure. If the weight of attached components exceeds the load limit, or if a more secure mounting is desired, (e.g. on rough surfaces), it can also be screw-mounted. All that is necessary to install STEGOFIX is a smooth and clean surface. The initial adhesive power is 40%, and after 24 hours, it has its full holding power of 1.1 lbs. Technical Data Application examples Load 1.1 lbs. (500 g) after a 24 hour waiting period* Mounting self-adhesive (non-aging, high-performance adhesive strip) Material plastic UL 94V-0, black Hole pattern 0.5" distance, O 0.14" (12.8 mm; O 3.6 mm) Operating / Storage temperature -49 to +158 F (-45 to 70 C) Dimensions 1.7 x 1.5 x 0.55" (43 x 38 x 14 mm) *depending on the conditions of use (e.g. surface condition, size of the device to be mounted, etc.) higher loads can be achieved. Installation STEGOFIX can only be mounted on smooth surfaces, e.g. metals, lacquered surfaces and plastics (except polyethylene, polypropylene and rubber). The surfaces must be dry and free from dust, oil, separating agents and other contamination. 0.55" (13.5 mm) 1.5" (38 mm) 1.7" (43 mm) 1.1" (27.5 mm) Part No. 09510.0-01 1 packing unit 5 pieces Weight (approx.) 2.1 oz. (60 g) total / 0.42 oz. (12 g) per piece Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com STEGOFIX/11-12/US 0.5" (12.8 mm) DD 084 Drainage Device IP66 / IP67 / IP69K protection Good drainage performance Easy to install Condensation can occur in enclosures with high protection types by variations in temperature. The use of the DD 084 drainage device allows the removal of the condensate without losing the maximum IP66 protection type. Accessories Weather and UV resistant The specific characteristic of the water permeable membrane ensures the drainage of the condensate via capillary action. The unique construction also prohibits the ingression of splash water into the enclosure. Additionally, the drainage device effectively provides pressure compensation with variations in temperature. Technical Data Mounting thread M50 x 1.5 with nut (wrench size 60 mm) torque 6 Nm max. Mounting position vertical, lowest point Depth in enclosure approx. 0.7" (17.5 mm) Material plastic, UL 94V-0, RAL 7022, weather and UV light resistant according to UL 746C (f1) Water entry height 0 mm (at 0.5 mm wall thickness) Sealing NBR gasket Water flow-through approx. 200 ml/h at 5 mm water column Dimensions O 2.36 x 1.9" (60 x 49.5 mm) Operating / Storage temperature -49 to +158 F (-45 to +70 C) Installation Make cut-out in enclosure bottom of O 2.0 inches (50.5+0.5 mm) and mount the drainage device with nut. Mounting position Part No. Protection type Enclosure wall thickness 1 packing unit Weight 08410.0-00 IP66 / IP67 (EN 60529) / IP69K (EN 40050-9) 0.02 - 0.22" (0.5 - 5.5 mm) 1 piece approx. 2 oz. (60 g) Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application. STEGO, Inc. * 1395 South Marietta Parkway * Building 800 * Marietta, GA 30067 * Tel: (770) 984-0858 * Fax: (770) 984-0615 Toll free: 1-888-783-4611 (US & Canada only) * www.stegousa.com DD084/11-12/US Make sure that the sealing gasket is placed on the outer side of the enclosure. HEATER CALCULATION SHEET Project: Project No.: Follow Steps 1-5 to determine the heating requirement of an enclosure (US units - left column, metric - right) STEP 1: Determine the Surface Area (A) of your enclosure which is exposed to open air Enclosure Dimensions: height = width = depth = feet feet feet meters meters meters Choose Mounting Option from next page, and calculate the surface area as indicated 2 A = ________ ft or 2 ________ m STEP 2: Choose the Heat Transmission Coefficient (k) for your enclosure's material of construction painted steel stainless steel aluminum plastic l ti (or ( insulated i l t d stainless) t i l ) = = = = 0.511 0.344 1.115 0.325 0 325 W/(ft 2*K) W/(ft 2*K) W/(ft 2*K) K) W/(ft 2*K) 2 k = ________ W/(ft *K) 5.5 3.7 12 3.5 3 5 or W/(m 2*K) W/(m 2*K) W/(m 2*K) W/( W/(m 2*K) K) 2 ________ W/(m *K) STEP 3: Determine the Temperature Differential (T) A. Desired enclosure interior temp. = B. Lowest ambient (outside) temp. = Subtract B from A = Temp. differential (T) = o o F o F o F C C o C T (oC) = T (K) Enter T (oC) below o For these calculations, T must be in degrees Kelvin (K). Therefore, divide T (oF) by 1.8 T = ________ K or ________ K STEP 4: Determine Heating Power (PV), if any (generated from existing components, i.e. transformer) PV = ________ W or ________ W STEP 5: Calculate the Required Heating Power (PH) for your enclosure based on the above values If enclosure is located inside: PH = (A x k x T) - PV = __________ W If enclosure is located outside: PH = 2 x (A x k x T) - PV = __________ W ENCLOSURE MOUNTING OPTIONS and SURFACE AREA CALCULATIONS 1. Free-Standing W H D Area (A) = 1.8(H x W) + 1.8(H x D) + 1.8(W x D) Area (A) = 1.8(H x W) + 1.4(H x D) + 1.8(W x D) Area (A) = 1.8(H x W) + (H x D) + 1.8(W x D) 2. Wall-Mounted Area (A) = 1.4(H x W) + 1.8(H x D) + 1.8(W x D) Area (A) = 1.4(H x W) + 1.4(H x D) + 1.8(W x D) Area (A) = 1.4(H x W) + (H x D) + 1.8(W x D) Area (A) = 1.8(H x W) + 1.4(H x D) + 1.4(W x D) Area (A) = 1.8(H x W) + (H x D) + 1.4(W x D) Area (A) = 1.4(H x W) + 1.4(H x D) + 1.4(W x D) Area (A) = 1.4(H x W) + (H x D) + 1.4(W x D) 3. Ground Area (A) = 1.8(H x W) + 1.8(H x D) + 1.4(W x D) Area (A) = 1.4(H x W) + 1.8(H x D) + 1.4(W x D) Mounting Options-06-08/US 4. Ground & Wall FILTER FAN SIZING SHEET Project: Project No.: To determine the Filter Fan size for a given enclosure, use the following calculation: Internal heat load (Pv) Required air volume (V) = x Air constant (f) Temperature difference (T) Metric US STEP 1: Determine the Internal Heat Load of the enclosure (Pv) Internal heat load, Pv (Watts) = _________ W = _________W [Note: 1 Watt = 3.413 BTU/hr.] STEP 2: Determine the Temperature Differential (T) Temperature difference (T) = _________ F = _________C = K [Max. temperature outside enclosure minus max. allowable temperature inside enclosure] STEP 3: Choose the Air Constant (f) 3 = _________ ft yF/W min Air constant (f) [Based on elevation, see below] 0 - 100 m 100 - 250 m 250 - 500 m 500 - 750 m 750 - 1000 m 3.3 ft3yF/W min 3.4 ft3yF/W min 3.5 ft3yF/W min 3.6 ft3yF/W min 3.7 ft3yF/W min or or or or or 3.1 m3yK/W hr 3.2 m3yK/W hr 3.3 m3yK/W hr 3.4 m3yK/W hr 3.5 m3yK/W hr Example: 600 W internal heat load, T = 15 K, at 75 m elevation 600 W V = x 15 K V = 132 m3/hr 3.3 m3yK/W hr 3 = _________ m yK/W hr