© Semiconductor Components Industries, LLC, 2016
May, 2016 − Rev. 0 1Publication Order Number:
CAS5140/D
CAS5140
Single Channel 256 Tap
Digital Potentiometer (POT)
with Integrated EEPROM
and I2C Control
The CAS5140 is a single channel non-volatile 256-tap digital POT.
This digital POT is comprised of a series of equal value resistor
elements connected between two externally accessible end points. The
tap points between each resistive element can be selectively connected
to the wiper output via internal CMOS switches forming a linear taper
electronic potentiometer.
The CAS5140 contains a volatile wiper register (WR) and an 8-bit
non-volatile EEPROM for wiper position and 5 additional
non-volatile registers for general purpose data storage. Programming
of the registers is controlled via I2C interface. On power up, the wiper
position is reset to the most recent value stored in the non-volatile
memory register (IVR).
The CAS5140 is available in an Pb free, RoHS compliant 8-lead
MSOP package, and operates over the industrial temperature range of
−40°C to +85°C.
Features
400 kHz I2C Compatible Interface
256 Position Linear Taper Potentiometer
End-to-End Resistance = 50 kW / 100 kW
TCR = 100 ppm/°C (typical)
Standby Current = 2 mA (max)
Typical Wiper Resistance = 70 W @ 3.3 V
Operating Voltage = 2.5 V to 5.5 V
6 Registers 8-bit Non-volatile EEPROM
2,000,000 Data Write Stores
100 Year Data Retention
8-lead MSOP Package
NiPdAu Plating
These Devices are Pb-Free and are RoHS Compliant
Figure 1. Functional Block Diagram
VCC
RH
RL
RW
WP
SCL
SDA
GND
Non−Volatile
ACR
WIPER
IVR
GP
GP
GP
I2C and
CONTROL
Volatile
www.onsemi.com
PIN CONNECTIONS
RW
RL
RH
VCC
GND
SDA
SCL
WP 1
(Top View)
See detailed ordering and shipping information in the package
dimensions section on page 2 of this data sheet.
ORDERING INFORMATION
MSOP−8 3x3
Z SUFFIX
CASE 846AD
ABUT = 100 kW Resistance
ABTJ = 50 kW Resistance
Y = Production Year
Y = (Last Digit)
M = Production Month
M = (1 − 9, A, B, C)
X = Production Revision
ABUT
YMX
MARKING DIAGRAM
1
ABTJ
YMX
1
CAS5140
www.onsemi.com
2
Table 1. ORDERING INFORMATION
Part Number Resistance Temperature Range Package Shipping
CAS5140ZI−50−GT3 50 kW−40°C to 85°CMSOP−8 3x3
(Pb-Free) 3000/Tape & Reel
CAS5140ZI−00−GT3 100 kW3000/Tape & Reel
For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
1. For detailed information and a breakdown of device nomenclature and numbering systems, please see the ON Semiconductor Device
Nomenclature document, TND310/D, available at www.onsemi.com.
Table 2. PIN FUNCTION DESCRIPTION
Pin No. Pin Name Description
1 WP Memory Write Protect: Active Low
2 SCL Serial Clock
3 SDA Serial Data
4 GND Ground
5 RWWiper Terminal
6 RLPotentiometer Low Terminal
7 RHPotentiometer High Terminal
8 VCC Supply Voltage
WP: Write Protect Input
The WP pin when tied low prevents any write operations
within the device.
SCL: Serial Clock
The CAS5140 serial clock input pin is used to clock all
data transfers into or out of the device.
SDA: Serial Data
The CAS5140 bidirectional serial data pin is used to
transfer data into and out of the device. The SDA pin is an
open drain output and can be wire-Ored with the other open
drain or open collector I/Os.
RH, RL: Resistor End Points
The set of RH and RL pins is equivalent to the terminal
connections on a mechanical potentiometer.
RW: Wiper
The RW pin is equivalent to the wiper terminal of a
mechanical potentiometer and its position is controlled by
the WR register.
Table 3. ABSOLUTE MAXIMUM RATINGS
Parameter Rating Unit
VIN Supply Voltage VCC to Ground (Note 2) −0.5 to +7 V
Terminal voltages: RH, RL, RW , SDA, SCL, WP −0.5 to VCC + 0.5 V
Wiper Current ±6.0 mA
Storage Temperature Range −65 to +150 °C
Junction Temperature Range −40 to +150 °C
Lead Soldering Temperature (10 seconds) 300 °C
ESD Rating HBM (Human Body Model) 2000 V
ESD Rating MM (Machine Model) 200 V
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be af fected.
2. The minimum DC input voltage is –0.5 V. During transitions, inputs may undershoot to –2.0 V for periods of less than 20 ns. Maximum DC
voltage on output pins is VCC +0.5 V, which may overshoot to VCC +2.0 V for periods of less than 20 ns.
Table 4. RECOMMENDED OPERATING CONDITIONS
Parameter Rating Unit
VCC 2.5 to 5.5 V
Wiper Current ±3 mA
Temperature Range −40 to +85 _C
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
CAS5140
www.onsemi.com
3
Table 5. POTENTIOMETER CHARACTERISTICS (Note 3) (VCC = +2.5 V to +5.5 V, −40_C to +85_C unless otherwise specified.)
Parameter Test Conditions Symbol
Limits
Units
Min Typ Max
Potentiometer Resistance ‘−50’ RPOT 50 kW
Potentiometer Resistance ‘−00’ RPOT 100 kW
Potentiometer Resistance Tolerance ±20 %
Power Rating 25°C 50 mW
Wiper Current IW±3 mA
Wiper Resistance IW = ±3 mA
VCC = 3.3 V RW70 200 W
Integral Non-Linearity Voltage Divider Mode INL ±1.5 LSB (Note 4)
Differential Non-Linearity DNL ±1.5 LSB (Note 4)
Integral Non-Linearity Resistor Mode RINL ±1.5 LSB (Note 4)
Differential Non-Linearity RDNL ±1.5 LSB (Note 4)
Voltage on RH or RLVSS = 0 V VTERM VSS VCC V
Resolution 0.4 %
Zero Scale Error 0 0.5 2 LSB (Note 5)
Full Scale Error −2 −0.5 0 LSB (Note 5)
Temperature Coefficient of RPOT (Notes 6, 7) TCRPOT ±100 ppm/°C
Ratiometric Temp. Coefficient (Notes 6, 7) TCRATIO 20 ppm/°C
Potentiometer Capacitances (Notes 6, 7) CH/CL/CW10/10/25 pF
Frequency Response RPOT = 50 kW (Note 8) fc 0.4 MHz
3. Latch-up protection is provided for stresses up to 100 mA on address and data pins from −1 V to VCC +1 V.
4. LSB = RTOT / 255 or (RH − R L) / 255, single pot. For mid−scale detail, please refer to corresponding graphs shown in Figures 2, 3, 4, and 5.
5. V(RW)255−V(RW)0]/255 (RW)255 = 0xFF, (RW)0 = 0x00.
6. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
7. Relative linearity is a measure of the error in step size. It is determined by the actual change in voltage between two successive tap positions
when used as a potentiometer.
8. This parameter is tested initially and after a design or process change that affects the parameter.
Table 6. D.C. OPERATING CHARACTERISTICS (VCC = +2.5 V to +5.5 V, − 40°C to +85°C unless otherwise specified.)
Parameter Test Conditions Symbol Min Max Units
Power Supply Current
Volatile Write & Read fSCL = 400 kHz
VCC = 5.5 V, Inputs = GND ICC1 1 mA
Power Supply Current
Non-volatile Write fSCL = 400 kHz
VCC = 5.5 V, Inputs = GND ICC2 3 mA
Standby Current VCC = 5.0 V ISB 2mA
Input Leakage Current VIN = GND to VCC ILI −10 +10 mA
Output Leakage Current VOUT = GND to VCC ILO 10 mA
Input Low Voltage VIL −1 VCC x 0.3 V
Input High Voltage VIH VCC x 0.7 VCC + 1.0 V
SDA Output Buffer Low Voltage VCC = 2.5 V, IOL = 4 mA VOL1 0.4 V
Power-On Recall Minimum VCC for memory recall VPOR 1.4 2.0 V
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
CAS5140
www.onsemi.com
4
Table 7. CAPACITANCE (TA = 25°C, f = 1.0 MHz, VCC = 5 V)
Test Test Conditions Symbol Max Units
Input/Output Capacitance (SDA) VI/O = 0 V CI/O (Note 9) 8 pF
Input Capacitance (SCL, WP) VIN = 0 V CIN (Note 9) 6 pF
Table 8. POWER UP TIMING (Notes 9 and 10)
Parameter Symbol Max Units
Power-up to Read Operation tPUR 1 ms
Power-up to Write Operation tPUW 1 ms
9. This parameter is tested initially and after a design or process change that affects the parameter.
10.tPUR and tPUW are delays required from the time VCC is stable until the specified operation can be initiated.
Table 9. DIGITAL POT TIMING
Parameter Symbol Min Max Units
Wiper Response Time After Power Supply Stable tWRPO 50 ms
Wiper Response Time: SCL falling edge after last bit of wiper position data
byte to wiper change tWR 20 ms
Table 10. ENDURANCE
Parameter Reference Test Method Symbol Min Max Units
Endurance MIL−STD−883, Test Method 1033 NEND 2,000,000 Cycles
Data Retention MIL−STD−883, Test Method 1008 TDR 100 Years
Table 11. A.C. CHARACTERISTICS (VCC = +2.5 V to +5.5 V, −40_C to +85_C unless otherwise specified.)
Parameter Symbol Min Typ Max Units
Clock Frequency fSCL 400 kHz
Clock High Period tHIGH 600 ns
Clock Low Period tLOW 1300 ns
Start Condition Setup Time (for a Repeated Start Condition) tSU:STA 600 ns
Start Condition Hold Time tHD:STA 600 ns
Data in Setup Time tSU:DAT 100 ns
Data in Hold Time tHD:DAT 0 ns
Stop Condition Setup Time tSU:STO 600 ns
Time the bus must be free before a new transmission can start tBUF 1300 ns
WP Setup Time tSU:WP 0ms
WP Hold Time tHD:WP 2.5 ms
SDA and SCL Rise Time tR300 ns
SDA and SCL Fall Time tF300 ns
Data Out Hold Time tDH 100 ns
Noise Suppression Time Constant at SCL, SDA Inputs TI50 ns
SLC Low to SDA Data Out and ACK Out tAA 1ms
Non-Volatile Write Cycle Time tWR 4 10 ms
CAS5140
www.onsemi.com
5
TYPICAL CHARACTERISTICS
Figure 2. Average Integral Non−Linearity
(Vcc = 2.4 V) Voltage Divider Mode Figure 3. Average Differential Non−Linearity
(Vcc = 2.4 V) Voltage Divider Mode
TAP TAP
250200150100500
−1.0
−0.8
−0.6
−0.2
0
0.2
0.4
0.6
250200150100500
−1.2
−1.0
−0.8
−0.6
−0.2
0
0.2
0.4
Figure 4. Average Integral Non−Linearity
(Vcc = 2.4 V) Resistor Mode Figure 5. Average Differential Non−Linearity
(Vcc = 2.4 V) Resistor Mode
TAP TAP
250200150100500
−0.8
−0.6
−0.2
0
0.2
0.4
0.6
0.8
250200150100500
−1.2
−1.0
−0.8
−0.6
−0.2
0
0.2
0.4
INL (LSB)
DNL (LSB)
INL (LSB)
DNL (LSB)
−0.4
−0.4
−0.4
−0.4
CAS5140
www.onsemi.com
6
SCL
SDA
Start
Condition Stop
Condition
StopStart
CLK1
SCL
SDA IN
WP
tSU:WP tHD:WP
tHD:STO, tHD:STO:NV
Figure 6. Start and STOP Timing
Figure 7. Bus Timing
Figure 8. Acknowledge Timing
Figure 9. WP Timing
Start
SCL from
Master
Data Output
from Transmitter
Data Output
from Receiver
189
Bus Release
Delay (Receiver)
ACK Setup ( tSU:DAT)
ACK Delay ( tAA)
Bus Release Delay (Transmitter)
tAA tDH
tF
tLOW
tHIGH
SCL
SDA IN
SDA OUT
tSU:STA tHD:STA
tHD:DAT
tBUF
tSU:STO
tSU:DAT
tR
CAS5140
www.onsemi.com
7
Device Operation
The CAS5140 is a resistor array integrated with a I2C
serial interface logic, an 8-bit volatile wiper register, and six
8-bit, non-volatile memory data registers. The resistor array
contains 255 separate resistive elements connected in series.
The physical ends of the array are equivalent to the fixed
terminals of a mechanical potentiometer (RH and RL). The
tap positions between and at the ends of the series resistors
are connected to the output wiper terminal (RW) by CMOS
transistor switches. Only one tap point for the potentiometer
is connected to the wiper terminal at a time and is determined
by the value of an 8-bit Wiper Register (WR).
RH
RW
RL
FFh
FEh
80h
01h
00h
When power is first applied to CAS5140 the wiper is set
to midscale; W iper Register = 80h. When the power supply
becomes sufficient to read the non-volatile memory the
value st o r e d i n t h e Init i a l Value Register (IVR) is transferred
into the Wiper Register and the wiper moves to this new
position. Five additional 8-bit non-volatile memory data
registers are provided for general purpose data storage. Data
can be read or written to the volatile or the non-volatile
memory data registers via the I2C bus.
Serial Bus Protocol
The following defines the features of the 2-wire bus
protocol:
1. Data transfer may be initiated only when the bus is
not busy.
2. During a data transfer, the data line must remain
stable whenever the clock line is high. Any
changes in the data line while the clock is high
will be interpreted as a START or STOP condition.
The device controlling the transfer is a master , typically a
processor o r controller, and the device being controlled is the
slave. The master will always initiate data transfers and
provide the clock for both transmit and receive operations.
Therefore, the CAS5140 will be considered a slave device
in all applications.
START Condition
The START condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of SDA
when SCL is HIGH. The CAS5140 monitors the SDA and
SCL lines and will not respond until this condition is met.
STOP Condition
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must end
with a STOP condition.
Device Addressing
The bus Master begins a transmission by sending a
START condition. The Master then sends the address of the
particular slave device it is requesting. CAS5140 has a fixed
7 bit slave address: 0101000. The 8th bit (LSB) is the
Read/Write instruction bit. For a Read the value is “1” and
for Write the value is “0”.
After the Master sends a START condition and the slave
address byte, the CAS5140 monitors the bus and responds
with an acknowledge (on the SDA line) when its address
matches the transmitted slave address.
Table 12. SALVE ADDRESS BIT FORMAT
MSB LSB
01 0 1 0 0 0 R/W
Acknowledge (ACK)
After a successful data transfer, each receiving device is
required to generate an acknowledge. The Acknowledging
device pulls down the SDA line during the ninth clock cycle,
signaling that it received the 8 bits of data.
CAS5140 responds with an acknowledge after receiving
a START condition and its slave address. If the device has
been selected along with a write operation, it responds with
an acknowledge after receiving each 8-bit byte. When the
CAS5140 is in a READ mode it transmits 8 bits of data,
releases the SDA line, and monitors the line for an
acknowledge. Once it receives this acknowledge, the
CAS5140 will continue to transmit data. If no acknowledge
is sent by the Master, the device terminates data transmission
and waits for a STOP condition.
WRITE Operation
In the Write mode, the Master device sends the START
condition and the slave address information to the Slave
device. In CAS5140’s case the slave address also contains a
Read/Write command (R/W) on the last bit of the 1st byte.
After receiving an acknowledge from the Slave, the Master
device transmits a second byte containing a Memory
Address to select an available register. After a second
acknowledge is received from the Slave, the Master device
sends the data to be written into the selected register. The
CAS5140
www.onsemi.com
8
CAS5140 acknowledges once more and the Master
generates the STOP condition, at which time if a nonvolatile
data register is being selected, the device begins an internal
programming cycle to non-volatile memory. If the STOP
condition is not sent immediately after the last ACK the
internal non-volatile programming cycle doesn’t start.
While this internal cycle is in progress, the device will not
respond to any request from the Master device.
Write operations to volatile memory are completed during
the last bit of the data byte before the slave’s acknowledge.
The device will be ready for another command only after a
STOP condition sent by Master.
Acknowledge Polling
The disabling of the inputs can be used to take advantage
of the typical write cycle time. Once the stop condition is
issued to indicate the end of the host’s write operation, the
CAS5140 initiates the internal write cycle. ACK polling can
be initiated immediately. This involves issuing the start
condition followed by the slave address. If the CAS5140 is
still busy with the write operation, no ACK will be returned.
If the CAS5140 has completed the write operation, an
acknowledge will be returned and the host can then proceed
with the next instruction operation.
WRITE Protection
The Write Protection feature allows the user to protect
against inadvertent programming of the non-volatile data
registers. I f the WP pin is tied to LOW, the data registers are
protected and become read only. Similarly, the WP p in going
low after start will interrupt a nonvolatile write to data
registers, while the WP pin going low after an internal write
cycle has started will have no effect on any write operation.
CAS5140 will accept slave addresses but the data registers
are protected from programming, which the device indicates
by failing to send an acknowledge after data is received.
READ Operation
A Read operation with a designated address consists of a
three byte instruction followed by one or more Data Bytes
(See Figure 7). The master initiates the operation issuing a
START, an Identification byte with the R/W bit set to “0”, an
Address Byte. Then the master sends a second START, and
a second Identification byte with the R/W bit set to “1”. After
each of the three bytes, the CAS5140 responds with an ACK.
Then CAS5140 transmits the Data Byte. The master then
can continue the read operation with the content of the next
register by sending acknowledge or can terminate the read
operation by issuing a NoACK followed by a STOP
condition after the last bit of a Data Byte.
Table 13. MEMORY MAP
Address
Non-volatile
Volatile
Register
Register Default
Value
8 ACR
7 Reserved
6General Purpose 00h N/A
5General Purpose 00h N/A
4General Purpose 00h N/A
3General Purpose 00h N/A
2General Purpose 00h N/A
1Device ID (read only) D0h N/A
0 IVR 80h WR
If the master sends address 07h or addresses greater than
08h the slave responds with NoACK after the Memory
Address byte.
Address 8: Volatile Access Control Register − ACR (I/O)
The ACR bit 7 (VOL) toggles between Non-volatile and volatile registers accessed at address 00h. When VOL is Low (0),
the non-volatile IVR is accessed at address 00h. When VOL is high (1), the volatile Wiper Register is accessed at address 00h.
The initial default value for VOL = 0.
Bit 7 6 5 4 3 2 1 0
Name 0/1 VOL 0 0 0 0 0 0 0
00h and 80h are the only values that should be written to address 08h. For any other value written to address 08h the slave will
load only bit 7 but it will answer with a NoACK.
Address 7: RESERVED
The user should not read or write to this address. CAS5140 will respond with NoACK and it will take no action.
Address 07h can be accessed only in a sequential read and its content is FFh.
Address 6−2: Non-volatile General Purpose Memory (I/O)
8-bit Non-volatile Memory
Bit 7 6 5 4 3 2 1 0
Name
General Purpose Memories are preprogrammed at the factory to a default value of “00h”.
CAS5140
www.onsemi.com
9
Address 1: Device ID (Read Only)
Bit 7 defines the Digital POT device manufacturer; Catalyst/On Semiconductor = high (1)
Bit 7 6 5 4 3 2 1 0
Name 1 1 0 1 0 0 0 0
A writing to address 1 has no effect. Attempts to do so will return an ACK but no data will be written.
Address 0: IVR/WR Register (I/O)
Address 00h accesses one of two memory registers: the initial value register (IVR) or the wiper register (WR) depending
upon the value of bit 7 in Access Control Register (ACR) which is at address 08h, above.
WR controls the wipers position and is a volatile memory while IVR is non-volatile and retains its data after the chip has
been powered down. Writes to IVR automatically update the WR while writes to WR leave IVR unaffected.
WR: Wiper Register = Volatile.
IVR: Initial Value Register = Non-volatile.
Writing and Reading operations:
1. If Bit 7 from ACR is 0 (non-volatile):
A write operation to address 00h will write the same value in WR and IVR.
A read operation to address 00h will output the content of IVR.
2. If bit 7 from ACR is 1 (volatile):
A write operation to address 00h will write in WR only.
A read operation to address 00h will output the content of WR.
All changes to the wipers position are immediate. There is no delay the wipers movement when writing to non-volatile
memory.
Bit 7 6 5 4 3 2 1 0
Name
IVR is preprogrammed at the factory to a default value of “80h”.
I2C SERIAL BUS INSTRUCTION FORMAT
Table 14. I2C SLAVE ADDRESS BITS
Transfer Data
Slave Address R/W bit
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
Read 51h 0 1 0 1 0 0 0 1 (R)
Write 50h 0 (W)
If the Slave Address Byte sent by the host is different the device will send a NoACK.
I2C Protocol:
(A) Write data procedure with designated address. (See Table 15)
1. Host transfers the start condition
2. Host transfers the device slave address with the write mode R/W bit (0).
3. Device sends ACK
4. Host transfers the corresponding memory address to the device
5. Device sends ACK
6. Host transfers the write data to the designated address
7. Device sends ACK
8. Routines (6) and (7) are repeated based on the transfer data, and the designated address is automatically incremented*
9. Host transfers the stop condition.
*Automatically incremented writes are not possible after a non-volatile write.
CAS5140
www.onsemi.com
10
Single write to either a volatile or non-volatile register. Note that Bit 7 of ACR determines which memory type is being written.
Table 15. SINGLE WRITE
(1) (2) (3) (4) (5) (6) (7) (9)
Start Slave
Address 0
R/W 0
ACK Memory
Address 0
ACK Write
Data 0
ACK Stop
A single write to either a volatile or non-volatile register. At address 00h bit 7 of ACR determines which memory type is being written.
Table 16. MULTIPLE WRITES
(1) (2) (3) (4) (5) (6) (7) (8) (9)
Start Slave
Address 0
R/W 0
ACK Memory
Address 0
ACK Write
Data 0
ACK Write
Data 0
ACK Stop
Multiple writes are possible only if the starting address is 08h and it should be stopped with the first nonvolatile data byte. If
a nonvolatile write does not end with a STOP procedure the register is not written.
(B) Read data procedure with designated address.
1. Host transfers the start condition
2. Host transfers the device slave address with the write mode R/W bit (0)
3. ACK signal recognition from the device
4. Host transfers the read address
5. ACK signal recognition from the device
6. Host transfers the re-start condition
7. Host transfers the slave address with the read mode R/W bit (1).
8. ACK signal recognition from the device
9. The device transfers the read data from the designated address
10. Host transfers ACK signal
11. The (9) & (10) routines above are repeated if needed, and the read address is auto-incremented
12. Host transfers ACK ‘H’ to the device
13. Host transfers the stop condition
Table 17. READ DATA
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13)
Start Slave
Address 0
R/W 0
ACK Memory
Address 0
ACK Restart Slave
Address 1
R/W 0
ACK Read
Data 0
ACK Read
Data 1
ACK Stop
(C) Read data procedure without a designated address.
1. Host transfers the start condition
2. Host transfers the device slave address with the read mode R/W bit =1
3. ACK signal recognition from the device. (Host then changes to receiver)
4. The device transfers data from the previous access address +1
5. Host transfers ACK signal
6. The (4) & (5) routines above are repeated if needed
7. Host transfers ACK ‘H’
8. Host transfers the stop condition
Table 18. Read Data w/o Designated Address
(1) (2) (3) (4) (5) (6) (7) (8)
Start Slave
Address 1
R/W 0
ACK Read
Data 0
ACK Read
Data 1
ACK Stop
CAS5140
www.onsemi.com
11
PACKAGE DIMENSIONS
MSOP 8, 3x3
CASE 846AD
ISSUE O
E1E
A2
A1 e b
D
c
A
TOP VIEW
SIDE VIEW
END VIEW
L1
L2
L
DETAIL A
DETAIL A
Notes:
(1) All dimensions are in millimeters. Angles in degrees.
(2) Complies with JEDEC MO-187.
SYMBOL MIN NOM MAX
q
θ
A
A1
A2
b
c
D
E
E1
e
L
L2
0.05
0.75
0.22
0.13
0.40
2.90
4.80
2.90
0.65 BSC
0.25 BSC
1.10
0.15
0.95
0.38
0.23
0.80
3.10
5.00
3.10
0.60
3.00
4.90
3.00
L1 0.95 REF
0.10
0.85
ON Semiconductor and the are registered trademarks of Semiconductor Components Industries, LLC (SCILLC) or its subsidiaries in the United States and/or other countries.
SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed
at www.onsemi.com/site/pdf/Patent− Marking.pdf. S CILLC r eserves the right t o make changes without further n otice to any product s herein. S CILLC makes no warrant y, representation
or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and
specifically disclaims any and all l iabilit y, including without l imit at ion s pecial, c onsequent ial o r i n cidental damages. “Typical” parameters which may be provided in SCILLC data sheets
and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each
customer application b y c ust omer’s technical e xperts. SCILLC does not c onvey a ny license under its p atent rights nor the rights of others. SCILLC products are n ot d esigned, i nt ended,
or authorized for use as c omponent s i n s yst ems i nt ended f or s urgic al i m plant i nt o the body, or other applications intended t o s upport o r s ust ain life, or for any other a pplicat ion in w hich
the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or
unauthorized application, Buyer shall indemnify and hold SCILLC an d it s officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and
expenses, and r easonable a ttorney f ees a rising o ut of, directly or i ndirectly, a ny c laim o f personal injury or d eath a ssociated w ith s uch u nint ended o r u nauthorized u se, e ven if such claim
alleges that SCILLC was negligent regarding the d esign or manufacture of the p art. SCILLC i s a n E qual O pportunity/Af firmative Act ion Employer. T his literature is s ubject t o all applicable
copyright laws and is not for resale in any manner.
P
UBLICATION ORDERING INFORMATION
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5817−1050
CAS5140/D
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
19521 E. 32nd Pkwy, Aurora, Colorado 80011 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: orderlit@onsemi.com
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your loc
al
Sales Representative