HS122DR Series Assemblies
•
45 amp AC output @ 40°C
•
Single or Dual Channel output
•
3 to 32 VDC input control voltage
•
DIN Rail mounted
•
uL, CSA, VDE, CE approved SSRs
PRODUCT SELECTION
Description 45 A 45 A 45 A
3-32 VDC Control HS122DR-D2450 HS122DR-HD6050 HS122DR-CC2450W3U
OUTPUT SPECIFICATIONS (1)
Description HS122DR-D2450 HS122DR-HD6050 HS122DR-CC2450W3U
Operating Voltage (47-63Hz) [Vrms] 24-280 48-660 24-280
Transient Overvoltage [Vpk] 600 1200 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10 0.1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 500
Maximum Load Current [Arms] 45 45 45
Minimum Load Current [Arms] 0.04 0.04 0.15
Maximum Surge Current (16.6ms) [Apk] 625 625 750
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.7 1.3
Maximum I²t for Fusing (8.3 msec) [A² sec] 1620 1620 2320
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5
INPUT SPECIFICATIONS (1)
Description HS122DR-D2450 HS122DR-HD6050 HS122DR-CC2450W3U
Control Voltage Range 3-32 VDC 3-32 VDC 4-32 VDC
Minimum T urn -On Voltage 3.0 VDC 3.0 VDC 4.0 VDC
Minimum Tu rn -Of f Volta ge 1.0 VDC 1.0 VDC 1.0 VDC
Maximum Reverse Voltage 32 VDC 32 VDC 32 VDC
Typical Input Current 3.4 mA @ 5 VDC 2.0 mA (3) 10 mA @ 12 VDC
Nominal Input Impeadance 1500 Ohms (3) (3)
Maximum Turn-On Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle
Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle
GENERAL SPECIFICATIONS
Description HS122DR-Dxx50 HS122DR-CC2450W3U
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 4000 Vrms
Minimum Insulation Resistance (@ 500 V DC) 109 Ohms 109 Ohms
Maximum Capacitance, Input/Output 8 pF 10 pF
Ambient Operating Temperature Range -40 to 80˚C-40 to 80°C
Ambient Storage Temperature Range -40 to 125˚C-40 to 125°C
Status Indicator Display None Yes
Weight (typical) 1.43 lb. (649g) 1.49 lb (662g)
Encapsulation Themall y Conductive Epoxy Themally Conductive Epoxy
Recommended Terminal Screw Torque Range: 6-32 Screws - 10 in/lbs. 8-32 Screws - 20 in/lbs.
(Screws dry without grease) 8-32 Screws - 20 in/lbs. (Screws dry without
grease)
Thermal pad installed Yes Yes
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Input circuitry for DC control version incorporates active current limiter (HD and Dual model only)
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
A
gency approvals are for relay only.
E116949 (D2450) E116950 (HD6050, CC2450W3U) LR81689 (D2450, HD6050)
10143 UG (D2450, HD6050)
Rev. 110811
ANNEX - ENVIROMENTAL INFORMATION