469-01, 469-02, and 469-03 SINGLE PHASE 10 AMP RECTIFIER BRIDGES SCOTTSDALE DIVISION APPEARANCE This series of high-current single-phase bridge rectifiers are constructed with hermetically sealed rectifiers with the same design and construction as used in military applications for the utmost in reliability. They can also be optionally obtained with formal military screened diodes that have been subjected to 100% screening and military qualified to MIL-PRF-19500/469 that are ideal for high-reliability applications where a failure cannot be tolerated. These industry-recognized 10 Amp rated rectifier bridges with working peak reverse voltages from 200 to 600 volts for each leg use diodes that are hermetically sealed with voidless-glass construction using an internal "Category I" metallurgical bond. Microsemi also offers numerous other rectifier products to meet higher and lower current ratings with various recovery time speed requirements including fast and ultrafast device types in both through-hole and surface mount packages. WWW . Microsemi .C OM DESCRIPTION IMPORTANT: For the most current data, consult MICROSEMI's website: http://www.microsemi.com FEATURES * * * * * * APPLICATIONS / BENEFITS * * * * * * * Voidless hermetically sealed glass packages used internally for each leg Triple-layer passivation Internal "Category I" Metallurgical bonds JANTX and JANTXV available per MIL-PRF-19500/469 Controlled Avalanche Characteristics Surge ratings of 100 Amps MicroNote 050 MAXIMUM RATINGS * * * * * o Conversion of single phase ac to dc current flow Working Peak Reverse Voltages 200 to 600 V Military and other high-reliability applications High forward surge current capability Low thermal resistance Extremely robust construction Inherently radiation hard as described in Microsemi MECHANICAL AND PACKAGING o * Junction Temperature: -65 C to +150 C Storage Temperature: -65oC to +150oC Maximum Avg Output Current: 10 Amps @ TC = 55C and 6 Amps @ TC = 100C. Derate @ 88 mA / oC between 55C and 100C. Derate @ 120 mA/ oC above 100C. Non-repetitive Forward Surge Current (8.3 ms half sine): 100 Amps @ TC = 55C o Solder temperatures (terminals): 260 C for 10 s (maximum) * * * * * CASE: Epoxy filled case with hermetically sealed void-less hard glass rectifiers with Tungsten slugs TERMINALS: Nickel plated brass with optional hot Tin-Lead solder dip MARKING: Part number on one side of case POLARITY: Marked on body adjacent to terminals (see terminal polarity marking on last page and flattened corner on case for pin 1) WEIGHT: 7.7 grams See package dimensions on last page ELECTRICAL CHARACTERISTICS TYPE WORKING PEAK REVERSE VOLTAGE VRWM VOLTS 240 460 660 VOLTS 469-01 469-02 469-03 NOTE 1: NOTE 2: NOTE 3: NOTE 4: 200 400 600 AVERAGE RECTIFIED CURRENT IO1 @ MAXIMUM REVERSE CURRENT PER LEG IR @ VRWM Note 1 AVERAGE RECTIFIED CURRENT IO2 @ o TC=+100 C Note 2 TC = 25C AMPS 10 10 10 AMPS 6 6 6 A 2 2 2 TC=+55oC REVERSE RECOVERY trr Note 3 TC = 100C FORWARD VOLTAGE VF @ 15.7 A (pk) @ 8.3 ms Duty Cycle 2% A 125 125 125 Volts 1.35 1.35 1.35 s 2.5 2.5 2.5 Rated at TC = 55C with reference to metal case. Derate linearly at 88 mA/C between TC = 55C and TC = 100C Derate linearly at 120 mA/C above TC = 100C. IF = 0.5 A, IRM = 1.0 A, IR(REC) = .250 A Point at which TC is referenced shall be in metal part of case as shown in drawing on last page. Copyright (c) 2009 11-05-09 Rev B; 469-1.pdf Microsemi Scottsdale Division 8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503 Page 1 469-01, 469-02, 469-03 MINIMUM BREAKDOWN VOLTAGE Per Leg VBR @50A 469-01, 469-02, and 469-03 SINGLE PHASE 10 AMP RECTIFIER BRIDGES SCOTTSDALE DIVISION Symbol VBR VRWM IO VF IR trr Minimum Breakdown Voltage: The minimum voltage the device will exhibit at a specified current. Working Peak Reverse Voltage: The maximum peak voltage that can be applied over the operating temperature range excluding all transient voltages (ref JESD282-B). Also sometimes known as PIV. Average Rectified Output Current: The Output Current averaged over a full cycle with a 50 Hz or 60 Hz sinewave input and a 180 degree conduction angle. Maximum Forward Voltage: The maximum forward voltage the device will exhibit at a specified current. Maximum Reverse Current: The maximum reverse (leakage) current that will flow at the specified voltage and temperature. Reverse Recovery Time: The time interval between the instant the current passes through zero when changing from the forward direction to the reverse direction and a specified decay point after a peak reverse current occurs. WWW . Microsemi .C OM SYMBOLS & DEFINITIONS Definition GRAPHS 469-01, 469-02, 469-03 FIGURE 1 Copyright (c) 2009 11-05-09 Rev B; 469-1.pdf Microsemi Scottsdale Division 8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503 Page 2 469-01, 469-02, and 469-03 SINGLE PHASE 10 AMP RECTIFIER BRIDGES SCOTTSDALE DIVISION WWW . Microsemi .C OM PACKAGE DIMENSIONS 469-01, 469-02, 469-03 Copyright (c) 2009 11-05-09 Rev B; 469-1.pdf Microsemi Scottsdale Division 8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503 Page 3