Datasheet Ambient light sensor ICs Digital 16bit Serial Output Type Color Sensor IC BH1745NUC General Description Key Specifications BH1745NUC is digital color sensor IC with I2C bus interface. This IC senses Red, Green and Blue light (RGB) and converts them to digital values. The high sensitivity, wide dynamic range and excellent Ircut characteristics makes this IC the most suitable to obtain the illuminance and color temperature of ambient light for adjusting LCD backlight of TV, mobile phone and tablet PC. It is possible to detect very wide range light intensity. (0.005 - 40k lx) VCC Voltage Range: Maximum Sensitivity: Current Consumption: Standby Mode Current: Operating Temperature Range: Package(s) WSON008X2120 2.3V to 3.6V 0.005Lx/step 130A (Typ) 0.8A (Typ) -40C to +85C W(Typ) x D(Typ) x H(Max) 2.10mm x 2.00mm x 0.6mm Features The Excellent Ircut Characteristics with an Ircut Filter The High Sensitivity and Wide Dynamic Range (0.005 - 40k lx) Supports Low Transmittance (Dark) Window 2 Correspond to I C Bus Interface ( f/s mode support ) Low Current by Power Down Function Rejecting 50Hz/60Hz Light Noise Correspond to 1.8V Logic Interface Programmable Interrupt Function 2 It is possible to select 2 type of I C bus slave address. (ADDR ='L': "0111000", ADDR ='H': "0111001") WSON008X2120 Applications LCD TV, Mobile phone, NOTE PC, Tablet PC, Portable game machine, Digital camera, Digital video camera, PDA, LCD display Typical Application Circuits 1.8V - 3.6V 2.3V - 3.6V (ex. 0.1F) ADC ADC Logic + GREEN 2 I C Interface ADC + SDA SDA SCL SCL 1.65V - 5.5V Micro Controller or Baseband Processor INT Interface ADC INT RED IRCUT FILTER BLUE VCC INT CLEAR ADDR ADDR ADC TEST OSC POR TEST GND Product structureSilicon monolithic integrated circuit. This product is not designed protection against radioactive rays. This product does not include laser transmitter. This product does not include optical load. This product includes Photo detector, ( Photo Diode ) inside of it. .www.rohm.com TSZ02201-0M3M0F616080-1-2 (c) 2014 ROHM Co., Ltd. All rights reserved. 1/19 TSZ2211114001 23.May.2016 Rev.002 BH1745NUC Pin Configuration TOP VIEW ADDR 1 8 NC VCC 2 7 INT GND 3 6 SDA TEST 4 5 SCL Pin Description Pin No. Pin Name Function 2 1 ADDR 2 VCC I C bus slave address terminal Power supply terminal 3 GND GND terminal 4 TEST Test terminal. Connect to GND. 5 SCL I C bus Interface SCL terminal. 6 SDA 7 INT 8 NC I C bus Interface SDA terminal. Nch open drain output. Interrupt setting is defined by internal register. Register value is 2 possible to configure by I C bus. Non connect (Open). 2 2 Block Diagram ADC ADC Logic PD + GREEN 2 I C Interface ADC SDA SCL + PD INT Interface ADC RED IRCUT FILTER BLUE VCC INT PD CLEAR ADDR ADC TEST PD OSC POR GND Description of Blocks Ircut Filter This filter passes visible light and blocks infrared light. RED, GREEN, BLUE, CLEAR Red, Green, Blue, and Clear color pass filter PD Photodiodes (PD) convert light into current. ADC AD converter for obtaining digital 16bit data. 2 ADC Logic + I C Interface + INT Interface 2 ADC control logic and I C bus Interface and Interrupt function Interface. OSC Internal oscillator (typ 720 kHz). It is clock for internal logic. POR Power on reset. All registers are reset after VCC is supplied. www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 2/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Absolute Maximum Ratings (Ta = 25C) Parameter Symbol Rating Unit VCCMAX -0.3 to +4.5 V VADDRMAX,VSDAMAX, VSCLMAX, VTESTMAX -0.3 to +4.5 V VINTMAX 7 V Operating Temperature TOPR -40 to +85 C Storage Temperature TSTG -40 to +100 C INT, SDA Sink Current IMAX 7 mA Power Dissipation PD 0.40 VCC, Supply Voltage ADDR, SDA, SCL, TEST Terminal Voltage INT Terminal Voltage (Note 1) W (Note 1) Reduce by 5.33mW/C over 25C, when mounted on 2-layer PCB of 114.3mm x 76.2mm x 1.6mm. PCB incorporates thermal via. Copper foil area on the reverse side of PCB : 74.2mmx74.2mm Caution: Operating the IC over the absolute maximum ratings may damage the IC. The damage can either be a short circuit between pins or an open circuit between pins and the internal circuitry. Therefore, it is important to consider circuit protection measures, such as adding a fuse, in case the IC is operated over the absolute maximum ratings. Recommended Operating Conditions (Ta= -40C to +85C) Parameter Symbol Min Typ Max Unit VCC Voltage VCC 2.3 2.5 3.6 V INT Terminal Voltage VINT 5.5 V SDA,SCL Terminal Voltage VI2C 3.6 V Electrical Characteristics (Unless otherwise specified, VCC=2.5V, Ta=25C, Registers are default value) Parameter Symbol Min Typ Max Unit Conditions Supply Current ICC1 130 250 A MODE_CONTROL2(42h)=10h, *(Note 2) Ev = 100 lx Standby Mode Current ICC2 0.8 1.5 A No Input Light Red Data Count Value DRED 3400 4000 4600 count MODE_CONTROL2(42h)=12h, 2 (Note 3) EV = 20W/cm DGREEN 2847 3350 3853 count MODE_CONTROL2(42h)=12h, 2 (Note 4) EV = 20W/cm Blue Data Count Value DBLUE 2014 2370 2726 count Clear Data Count Value DCLEAR 128 160 192 count Dark Count Value S0_0 0 0 3 count RGBC Data Update Period TINT - 160 225 msec INT Output `L' Voltage VINTL 0 0.4 V SCL SDA Input 'H' Voltage VIH 1.26 V SCL SDA Input 'L' Voltage VIL 0.54 V SCL SDA Input 'H'/'L' Current IIHL -10 10 A VOL 0 0.4 V ADDR Input 'H' Voltage VADDRH VCC*0.7 V ADDR Input 'L' Voltage VADDRL VCC*0.3 V Green Data Count Value 2 I C SDA Output 'L' Voltage MODE_CONTROL2(42h)=12h, 2 (Note 5) EV = 20W/cm MODE_CONTROL2(42h)=12h, 2 (Note 4) EV = 20W/cm MODE_CONTROL2(42h)=12h, No input light MODE_CONTROL2(42h)=10h IINT = 3mA IOL = 3mA (Note 2) White LED is used as optical source. (Note 3) Red LED is used as optical source. (Note 4) Green LED is used as optical source. (Note 5) Blue LED is used as optical source. www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 3/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC 2 I C Bus Timing Characteristics (Unless otherwise specified VCC=2.5V Ta=25C) Parameter Symbol Min Typ Max Unit fSCL 0 400 kHz tHD;STA 0.6 s 2 tLOW 1.3 s 2 tHIGH 0.6 s tSU;STA 0.6 s 2 tHD;DAT 0 s 2 tSU;DAT 100 ns 2 tSU;STO 0.6 s tBUF 1.3 s 2 tVD;DAT 0.9 s 2 tVD;ACK 0.9 s 2 I C SCL Clock Frequency Conditions 2 I C Hold Time ( Repeated ) START Condition I C 'L' Period of the SCL Clock I C 'H' Period of the SCL Clock 2 I C Set up time for a Repeated START Condition I C Data Hold Time I C Data Setup Time I C Set up Time for STOP Condition 2 I C Bus Free Time between a STOP and START Condition I C Data Vaild Time I C Data Vaild Acknowledge Time tSU;DAT 1.26V S DA 0.54V cont. 0.54V tHD ;DAT tVD ;DAT tHIGH 1.26V S CL 1.26V 0.54V tHD ;STA S 0.54V 1.26V 1.26V 0.54V cont. 0.54V tLOW 1/fSCL 9 th clock 1 st clock cycle tBUF S DA tSU;STA tVD ;ACK tHD ;STA tSU;STO 1.26V S CL 0.54V Sr www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 9 th clock 4/19 P S TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Typical Performance Curves 1.0 10 Blue Green 8 Red Calculated Illuminance [lx] Sensitivity Ratio 0.8 0.6 0.4 Clear 0.2 4 2 0.0 400 6 0 500 600 700 800 900 Wavelength [nm] 1000 1100 -40 0 20 40 Ta [ ] 60 80 100 Figure 2. Temperature Dependency of Dark ( 0 lx ) Sensor out from RGBC (MODE_CONTROL2=10h) Figure 1. RGBC Spectral Response 1.2 1.2 1.0 1.0 0.8 0.8 - 0.6 1pin + Ratio Ratio -20 0.4 0.6 0.4 - - - + + 1pin + 0.2 0.2 0.0 0.0 -90 -60 -30 0 30 60 90 Angle [deg] -60 -30 0 30 60 90 Angle [deg] Figure 3. Directional Characteristics 1 www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 -90 Figure 4. Directional Characteristics 2 5/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Typical Performance Curves - continued 8000 Fluorescent Light White LED 1.00 7000 1.06 Incandescent Light (Dimming) 0.98 Halogen Light 1.06 White LED 1.03 Calculated CCT [K] Fluorescent light Incandescent Light 6000 5000 4000 Incandescent light Halogen light 3000 Incandescent light (Dimming) 2000 0.0 0.5 1.0 1.5 2.0 4000 6000 8000 CCT [K] Ratio Figure 5. Light Source Dependency of lx calculation from RGBC (Fluorescent Light is set to "1") www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 2000 Figure 6. Light Source Dependency of CCT calculation from RGBC 6/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Command Set Address TYPE Default Register Name Register Function 40h RW 0Bh SYSTEM_CONTROL System control 41h RW 00h MODE_CONTROL1 Function setting 42h RW 00h MODE_CONTROL2 Function setting 44h RW 00h MODE_CONTROL3 Function setting 50h R 00h RED_DATA_LSBs Low byte of RED 51h R 00h RED_DATA_MSBs High byte of RED 52h R 00h GREEN_DATA_LSBs Low byte of GREEN 53h R 00h GREEN_DATA_MSBs High byte of GREEN 54h R 00h BLUE_DATA_LSBs Low byte of BLUE 55h R 00h BLUE_DATA_MSBs High byte of BLUE 56h R 00h CLEAR_DATA_LSBs Low byte of CLEAR 57h R 00h CLEAR_DATA_MSBs High byte of CLEAR 58h R 00h DINT_DATA_LSBs Low byte of Internal Data 59h R 00h DINT_DATA_MSBs High byte of Internal Data 60h RW 00h INTERRUPT Interrupt setting 61h RW 01h PERSISTENCE Persistence setting 62h RW FFh TH_LSBs Higher threshold low byte 63h RW FFh TH_MSBs Higher threshold high byte 64h RW 00h TL_LSBs Lower threshold low byte 65h RW 00h TL_MSBs Lower threshold high byte 92h R E0h MANUFACTURER ID Manufacturer ID SYSTEM_CONTROL ( 40h ) Field Bit TYPE SW reset 7 RW INT reset 6 RW 5:0 R Part ID Description 0 : initial reset is not started 1 : initial reset is started 0 : INT pin status is not initialized. 1 : INT pin become inactive ( high impedance ) 001011 Default value 0Bh MODE_CONTROL1 ( 41h ) Bit TYPE Description Reserved Field 7:3 RW Measurement time 2:0 RW Write 000000 RGBC Measurement time. RGBC each data are updated by the following time. 000 : 160msec 001 : 320msec 010 : 640msec 011 : 1280msec 100 : 2560msec 101 : 5120msec 110 : Forbidden to use 111 : Forbidden to use Default value 00h www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 7/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC MODE_CONTROL2 ( 42h ) Field Bit TYPE 7 R Reserved 6:5 RW RGBC_EN 4 RW Reserved 3:2 RW ADC GAIN 1:0 RW VALID Description 0 : RGBC data is not updated after last writing MODE_CONTROL1,2,3 register or last reading MODE_CONTROL2 register. 1 : RGBC data is updated after last writing MODE_CONTROL1,2,3 register or last reading MODE_CONTROL2 register. Write 00 0 : RGBC measurement is inactive and becomes power down. 1 : RGBC measurement is active. Write 00 GAIN setting for RGBC measurement. 00 : 1X 01 : 2X 10 : 16X 11 : Forbidden to use Default value 00h MODE_CONTROL3 ( 44h ) Field MODE_CONTROL3 Bit 7:0 TYPE RW Description Write 02h. Default value 00h RED_DATA_LSBs ( 50h ) Register RED_DATA_LSBs TYPE R 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 2 2 2 2 2 2 2 2 0 Default value 00h RED_DATA_MSBs ( 51h ) Register RED_DATA_MSBs TYPE R 7 2 15 6 2 14 5 2 13 4 2 12 3 2 11 2 2 10 1 0 9 2 2 8 Default value 00h GREEN_DATA_LSBs( 52h ) Register GREEN_DATA_LSBs TYPE R 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 2 2 2 2 2 2 2 2 0 Default value 00h GREEN_DATA_MSBs( 53h ) Register GREEN_DATA_MSBs TYPE R 7 2 15 6 2 14 5 2 13 4 2 12 3 2 11 2 2 10 1 0 9 2 2 8 Default value 00h BLUE_DATA_LSBs ( 54h ) Register BLUE_DATA_LSBs TYPE R 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 2 2 2 2 2 2 2 2 0 Default value 00h BLUE_DATA_MSBs ( 55h ) Register BLUE_DATA_MSBs TYPE R 7 2 15 6 2 14 5 2 13 4 2 12 3 2 11 2 2 10 1 0 9 2 2 8 Default value 00h www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 8/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC CLEAR_DATA_LSBs( 56h ) Register TYPE CLEAR_DATA_LSBs R 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 2 2 2 2 2 2 2 2 0 Default value 00h CLEAR_DATA_MSBs( 57h ) Register TYPE CLEAR_DATA_MSBs R 7 2 15 6 2 14 5 2 13 4 2 12 3 2 11 2 2 10 1 0 9 2 2 8 Default value 00h DINT_DATA_LSBs( 58h ) Register TYPE Reserved R 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 2 2 2 2 2 2 2 2 0 Default value 00h DINT_DATA_MSBs( 59h ) Register TYPE Reserved R 7 2 15 6 2 14 5 2 13 4 2 12 3 2 11 2 2 10 1 0 9 2 2 8 Default value 00h DINT registers output data for internal calculation of BH1745NUC. This register is unnecessary to read. It is used for IC Test only. INTERRUPT ( 60h ) Field Bit TYPE 7 R 6:5 R 4 RW 3:2 RW Reserved 1 RW INT ENABLE 0 RW INT STATUS Reserved INT LATCH INT SOURCE Description INT STATUS of RGBC 0 : Interrupt signal is inactive 1 : Interrupt signal is active Reserved 0 : INT pin is latched until INTERRUPT register is read or initialized. 1 : INT pin is updated after each measurement. INT source select 00 : Red channel 01 : Green channel 10 : Blue channel 11 : Clear channel Write 0 0 : INT pin disable. 1 : INT pin enable. Default value 00h PERSISTENCE ( 61h ) Field Bit TYPE Description Reserved 7:2 R PERSISTENCE 1:0 RW Reserved Interrupt persistence function. 00 : Interrupt status is toggled at each measurement end. 01 : Interrupt status is updated at each measurement end. 10 : Interrupt status is updated if 4 consecutive threshold judgments are the same. 11 : Interrupt status is updated if 8 consecutive threshold judgments are the same. Default value 01h www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 9/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC TH_LSBs ( 62h ) Register TH_LSBs TYPE RW 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 2 2 2 2 2 2 2 2 0 Default value FFh TH_MSBs ( 63h ) Register TH_MSBs TYPE RW 7 2 15 6 2 14 5 2 13 4 2 12 3 2 11 2 2 10 1 0 9 2 2 8 Default value FFh TL_LSBs ( 64h ) Register TL_LSBs TYPE RW 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 2 2 2 2 2 2 2 2 0 Default value 00h TL_MSBs ( 65h ) Register TL_MSBs TYPE RW 7 2 15 6 2 14 5 2 13 4 2 12 3 2 11 2 2 10 1 0 9 2 2 8 Default value 00h MANUFACTURER ID ( 92h ) Register Manufacturer ID TYPE 7 6 5 4 3 2 1 0 R 1 1 1 0 0 0 0 0 Default value E0h www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 10/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Explanation of Software Reset Command All registers are reset and BH1745NUC becomes power down by Software reset command. Explanation of Accessing MODE_CONTROL If master Writes to MODE_CONTROL1(41h), MODE_CONTROL2(42h) and MODE_CONTROL3(44h) register, RGBC measurement currently in progress is interrupted immediately and re-started from the beginning, and VALID register returns to `L'. When the re-started measurement is finished, VALID register turns to `H'. Power on Sequence Please note the below behavior when application design. 1) Power on time: t1 "t1" should be more than 2ms. The IC becomes active state after 2ms by which VCC voltage goes beyond 2.0V from less than 0.4V. 2) Power off time: t2 "t2" should be more than 1ms. The period that VCC is less than 0.4V should be more than 1ms before power supply. * "active state" means the state that the IC operates correctly. When power supply, INT terminal is hi-impedance state. Once VCC goes below 2.0V, power supply sequence should follow below sequence. 2.0V VCC 0.4V t1 t2 t1 BH1745NUC Undefined behavior www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 active Undefined behavior 11/19 active TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC 2 I C Bus Communication 1) Slave address "0111000" (ADDR = `L') or "0111001" (ADDR = `H') 2) Main write format 1. Case of Indicate register address ST 2. Slave Address W 0 ACK Indicate register address ACK SP Case of write to data register after indicating register address ST Slave Address Data specified at register address field W 0 ACK ACK ACK Indicate register address ACK Data specified at register address field + N ACK SP BH1745NUC continues to receive data with address increments until master issues stop condition. Write cycle is 40h - 41h - 42h - 43h ...57h - 58h - 59h ...FFh - 00h - 01h ...3Fh - 40h...... All registers are included in write-chain. Ex) If register address field is 42h, then BH1745NUC writes data like seeing in below. 42h - 43h - 44h - 45h - 46h ......... 3Eh - 3Fh - 40h....... It is continued until master issues stop condition. *There is no registers in address 00h-3Fh, 43h, 45h - 4Fh, 5Ah - 5Fh and 66h - 91h, 93h-FFh, but it is necessary to access these registers when writing some data with address increments. It is recommended to access 40h - 42h, 50h - 50h - 57h and 60h - 65h individually. 3) Main read format 1. Case of read data after indicate register address (Master issues restart condition) ST ST Slave Address Slave Address Data specified at register address field + 1 W 0 ACK R 1 ACK ACK Slave Address R 1 ACK Data specified at register address field + 1 ACK Indicate register address Data specified at register address field ACK Data specified at register address field + N ACK ACK NACK SP 2. Case of read data ST Data specified at register address field ACK Data specified at register address field + N ACK NACK SP BH1745NUC outputs data from specified address field until master issues stop condition. Read cycle is 40h - 41h - 42h - 43h ...57h - 58h - 59h ...FFh - 00h - 01h ...3Fh - 40h...... All registers are included in read-chain. Ex) If register address field is 50h, then BH1745NUC outputs data like seeing in below. 50h - 51h - 52h ......FFh - 00h - 01h...3Fh - 40h... It is continued until master issues stop condition. *There is no registers in address 00h-3Fh, 43h, 45h - 4Fh, 5Ah - 5Fh and 66h - 91h, 93h-FFh, but it is necessary to access these registers when reading data with address increments. It is recommended to access 40h - 44h, 50h - 50h - 57h, 60h - 65h and 92h individually. When master access to register address that does not exists, FFh is read. from slave to master from master to slave 2 *BH1745NUC operates as I C bus slave device. 2 *Please refer formality I C bus specification of NXP semiconductor www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 12/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Interrupt Function Interrupt function compares the measurement result selected from RGBC data by INT SOURCE register (60h<3:2>) to preset interrupt threshold level. Interrupt status is monitored by INT pin. Interrupt function is able to be controlled by INTERRUPT register (60h). Interrupt persistence is defined at PERSIST register (61h). INT pin is Nch open drain terminal so this terminal should be pull-up to some kind of voltage source by an external resister. There are two output modes about interrupt function (latched mode and unlatched mode). INT terminal is high impedance when VCC is supplied. INT terminal becomes inactive by writing INT reset command, reading INTERRUPT register, writing 0 to INT ENABLE bit of INTERRUPT register or software reset. INT terminal keeps just previous state when power down command is sent. So to set INT terminal to high impedance before power down command is sent is recommended. VCC current (approximately 25A at VCC=2.5V) is consumed during INT terminal is `L'. Ex1 ) In case of unlatch mode if the Data measurement value is within the range set by interrupt threshold `H' and `L' value, the interrupt becomes inactive. And if the measurement value is out of the range set by threshold `H' and `L' value, the interrupt becomes active. In case of latch mode once the interrupt becomes active, it keeps the status until INT reset command is done or INTERRUPT register is read. Master writes "Interrupt reset" command. INT Terminal H persistence = 1 L H persistence = 4 L DATA (selected from RGBC) Interrupt threshold H level sequential measurement results Interrupt threshold L level time www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 13/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC I/O Equivalent Circuit PIN No. 1 Pin Name ADDR Equivalent Circuit VCC 2 VCC 3 GND 4 TEST 5 SCL 6 SDA 7 INT 8 NC www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 14/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Operational Notes 1. Reverse Connection of Power Supply Connecting the power supply in reverse polarity can damage the IC. Take precautions against reverse polarity when connecting the power supply, such as mounting an external diode between the power supply and the IC's power supply terminals. 2. Power Supply Lines Design the PCB layout pattern to provide low impedance supply lines. Separate the ground and supply lines of the digital and analog blocks to prevent noise in the ground and supply lines of the digital block from affecting the analog block. Furthermore, connect a capacitor to ground at all power supply pins. Consider the effect of temperature and aging on the capacitance value when using electrolytic capacitors. 3. Ground Voltage Ensure that no pins are at a voltage below that of the ground pin at any time, even during transient condition. 4. Ground Wiring Pattern When using both small-signal and large-current ground traces, the two ground traces should be routed separately but connected to a single ground at the reference point of the application board to avoid fluctuations in the small-signal ground caused by large currents. Also ensure that the ground traces of external components do not cause variations on the ground voltage. The ground lines must be as short and thick as possible to reduce line impedance. 5. Thermal Consideration Should by any chance the power dissipation rating be exceeded the rise in temperature of the chip may result in deterioration of the properties of the chip. The absolute maximum rating of the Pd stated in this specification is when the IC is mounted on a 70mm x 70mm x 1.6mm glass epoxy board. In case of exceeding this absolute maximum rating, increase the board size and copper area to prevent exceeding the Pd rating. 6. Recommended Operating Conditions These conditions represent a range within which the expected characteristics of the IC can be approximately obtained. The electrical characteristics are guaranteed under the conditions of each parameter. 7. Rush Current When power is first supplied to the IC, it is possible that the internal logic may be unstable and inrush current may flow instantaneously due to the internal powering sequence and delays, especially if the IC has more than one power supply. Therefore, give special consideration to power coupling capacitance, power wiring, width of ground wiring, and routing of connections. 8. Operation Under Strong Electromagnetic Field Operating the IC in the presence of a strong electromagnetic field may cause the IC to malfunction. 9. Testing on Application Boards When testing the IC on an application board, connecting a capacitor directly to a low-impedance output pin may subject the IC to stress. Always discharge capacitors completely after each process or step. The IC's power supply should always be turned off completely before connecting or removing it from the test setup during the inspection process. To prevent damage from static discharge, ground the IC during assembly and use similar precautions during transport and storage. 10. Inter-pin Short and Mounting Errors Ensure that the direction and position are correct when mounting the IC on the PCB. Incorrect mounting may result in damaging the IC. Avoid nearby pins being shorted to each other especially to ground, power supply and output pin. Inter-pin shorts could be due to many reasons such as metal particles, water droplets (in very humid environment) and unintentional solder bridge deposited in between pins during assembly to name a few. www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 15/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Operational Notes - continued 11. Unused Input Terminals Input terminals of an IC are often connected to the gate of a MOS transistor. The gate has extremely high impedance and extremely low capacitance. If left unconnected, the electric field from the outside can easily charge it. The small charge acquired in this way is enough to produce a significant effect on the conduction through the transistor and cause unexpected operation of the IC. So unless otherwise specified, unused input terminals should be connected to the power supply or ground line. 12. Regarding the Input Pin of the IC This monolithic IC contains P+ isolation and P substrate layers between adjacent elements in order to keep them isolated. P-N junctions are formed at the intersection of the P layers with the N layers of other elements, creating a parasitic diode or transistor. For example (refer to figure below): When GND > Pin A and GND > Pin B, the P-N junction operates as a parasitic diode. When GND > Pin B, the P-N junction operates as a parasitic transistor. Parasitic diodes inevitably occur in the structure of the IC. The operation of parasitic diodes can result in mutual interference among circuits, operational faults, or physical damage. Therefore, conditions that cause these diodes to operate, such as applying a voltage lower than the GND voltage to an input pin (and thus to the P substrate) should be avoided. Resistor Transistor (NPN) Pin A Pin B C Pin A P + N P + N N P N Parasitic Elements N P+ E N P N P+ B N C E Parasitic Elements P Substrate P Substrate Parasitic Elements Pin B B GND Parasitic Elements GND GND N Region close-by GND Figure xx. Example of monolithic IC structure 13. Ceramic Capacitor When using a ceramic capacitor, determine the dielectric constant considering the change of capacitance with temperature and the decrease in nominal capacitance due to DC bias and others. 14. Area of Safe Operation (ASO) Operate the IC such that the output voltage, output current, and power dissipation are all within the Area of Safe Operation (ASO). www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 16/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Ordering Information B H 1 7 4 5 Part Number N U C - Package NUC : WSON008X2120 E2 Packaging and forming specification E2: Embossed tape and reel Marking Diagram WSON008X2120(TOP VIEW) Part Number Marking A C 1 PIN MARK LOT Number Optical design for the device 2mm 1mm 1.05mm 2.1mm 0.29mm sensitive area 0.6 x 0.6mm www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 17/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Physical Dimension, Tape and Reel Information Package Name www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 WSON008X2120 18/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 BH1745NUC Revision History Date Revision Changes 30.Jun.2014 001 New Release 23.May.2016 002 Correct description of VALID register. Correct register name. Correct "Operational Notes". www.rohm.com (c) 2014 ROHM Co., Ltd. All rights reserved. TSZ2211115001 19/19 TSZ02201-0M3M0F616080-1-2 23.May.2016 Rev.002 Notice Precaution on using ROHM Products 1. Our Products are designed and manufactured for application in ordinary electronic equipments (such as AV equipment, OA equipment, telecommunication equipment, home electronic appliances, amusement equipment, etc.). If you (Note 1) intend to use our Products in devices requiring extremely high reliability (such as medical equipment , transport equipment, traffic equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car accessories, safety devices, etc.) and whose malfunction or failure may cause loss of human life, bodily injury or serious damage to property ("Specific Applications"), please consult with the ROHM sales representative in advance. Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of any ROHM's Products for Specific Applications. (Note1) Medical Equipment Classification of the Specific Applications JAPAN USA EU CHINA CLASS CLASSb CLASS CLASS CLASS CLASS 2. ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which a failure or malfunction of our Products may cause. The following are examples of safety measures: [a] Installation of protection circuits or other protective devices to improve system safety [b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure 3. Our Products are designed and manufactured for use under standard conditions and not under any special or extraordinary environments or conditions, as exemplified below. Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the use of any ROHM's Products under any special or extraordinary environments or conditions. If you intend to use our Products under any special or extraordinary environments or conditions (as exemplified below), your independent verification and confirmation of product performance, reliability, etc, prior to use, must be necessary: [a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents [b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust [c] Use of our Products in places where the Products are exposed to sea wind or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves [e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items [f] Sealing or coating our Products with resin or other coating materials [g] Use of our Products without cleaning residue of flux (even if you use no-clean type fluxes, cleaning residue of flux is recommended); or Washing our Products by using water or water-soluble cleaning agents for cleaning residue after soldering [h] Use of the Products in places subject to dew condensation 4. The Products are not subject to radiation-proof design. 5. Please verify and confirm characteristics of the final or mounted products in using the Products. 6. In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse. is applied, confirmation of performance characteristics after on-board mounting is strongly recommended. Avoid applying power exceeding normal rated power; exceeding the power rating under steady-state loading condition may negatively affect product performance and reliability. 7. De-rate Power Dissipation depending on ambient temperature. When used in sealed area, confirm that it is the use in the range that does not exceed the maximum junction temperature. 8. Confirm that operation temperature is within the specified range described in the product specification. 9. ROHM shall not be in any way responsible or liable for failure induced under deviant condition from what is defined in this document. Precaution for Mounting / Circuit board design 1. When a highly active halogenous (chlorine, bromine, etc.) flux is used, the residue of flux may negatively affect product performance and reliability. 2. In principle, the reflow soldering method must be used on a surface-mount products, the flow soldering method must be used on a through hole mount products. If the flow soldering method is preferred on a surface-mount products, please consult with the ROHM representative in advance. For details, please refer to ROHM Mounting specification Notice-PGA-E (c) 2015 ROHM Co., Ltd. All rights reserved. Rev.003 Precautions Regarding Application Examples and External Circuits 1. If change is made to the constant of an external circuit, please allow a sufficient margin considering variations of the characteristics of the Products and external components, including transient characteristics, as well as static characteristics. 2. You agree that application notes, reference designs, and associated data and information contained in this document are presented only as guidance for Products use. Therefore, in case you use such information, you are solely responsible for it and you must exercise your own independent verification and judgment in the use of such information contained in this document. ROHM shall not be in any way responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of such information. Precaution for Electrostatic This Product is electrostatic sensitive product, which may be damaged due to electrostatic discharge. Please take proper caution in your manufacturing process and storage so that voltage exceeding the Products maximum rating will not be applied to Products. Please take special care under dry condition (e.g. Grounding of human body / equipment / solder iron, isolation from charged objects, setting of Ionizer, friction prevention and temperature / humidity control). Precaution for Storage / Transportation 1. Product performance and soldered connections may deteriorate if the Products are stored in the places where: [a] the Products are exposed to sea winds or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2 [b] the temperature or humidity exceeds those recommended by ROHM [c] the Products are exposed to direct sunshine or condensation [d] the Products are exposed to high Electrostatic 2. Even under ROHM recommended storage condition, solderability of products out of recommended storage time period may be degraded. It is strongly recommended to confirm solderability before using Products of which storage time is exceeding the recommended storage time period. 3. Store / transport cartons in the correct direction, which is indicated on a carton with a symbol. Otherwise bent leads may occur due to excessive stress applied when dropping of a carton. 4. Use Products within the specified time after opening a humidity barrier bag. Baking is required before using Products of which storage time is exceeding the recommended storage time period. Precaution for Product Label A two-dimensional barcode printed on ROHM Products label is for ROHM's internal use only. Precaution for Disposition When disposing Products please dispose them properly using an authorized industry waste company. Precaution for Foreign Exchange and Foreign Trade act Since concerned goods might be fallen under listed items of export control prescribed by Foreign exchange and Foreign trade act, please consult with ROHM in case of export. Precaution Regarding Intellectual Property Rights 1. All information and data including but not limited to application example contained in this document is for reference only. ROHM does not warrant that foregoing information or data will not infringe any intellectual property rights or any other rights of any third party regarding such information or data. 2. ROHM shall not have any obligations where the claims, actions or demands arising from the combination of the Products with other articles such as components, circuits, systems or external equipment (including software). 3. No license, expressly or implied, is granted hereby under any intellectual property rights or other rights of ROHM or any third parties with respect to the Products or the information contained in this document. Provided, however, that ROHM will not assert its intellectual property rights or other rights against you or your customers to the extent necessary to manufacture or sell products containing the Products, subject to the terms and conditions herein. Other Precaution 1. This document may not be reprinted or reproduced, in whole or in part, without prior written consent of ROHM. 2. The Products may not be disassembled, converted, modified, reproduced or otherwise changed without prior written consent of ROHM. 3. In no event shall you use in any way whatsoever the Products and the related technical information contained in the Products or this document for any military purposes, including but not limited to, the development of mass-destruction weapons. 4. The proper names of companies or products described in this document are trademarks or registered trademarks of ROHM, its affiliated companies or third parties. Notice-PGA-E (c) 2015 ROHM Co., Ltd. All rights reserved. Rev.003 Datasheet General Precaution 1. Before you use our Pro ducts, you are requested to care fully read this document and fully understand its contents. ROHM shall n ot be in an y way responsible or liabl e for fa ilure, malfunction or acci dent arising from the use of a ny ROHM's Products against warning, caution or note contained in this document. 2. All information contained in this docume nt is current as of the issuing date and subj ect to change without any prior notice. Before purchasing or using ROHM's Products, please confirm the la test information with a ROHM sale s representative. 3. The information contained in this doc ument is provi ded on an "as is" basis and ROHM does not warrant that all information contained in this document is accurate an d/or error-free. ROHM shall not be in an y way responsible or liable for an y damages, expenses or losses incurred b y you or third parties resulting from inaccur acy or errors of or concerning such information. Notice - WE (c) 2015 ROHM Co., Ltd. All rights reserved. Rev.001 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: ROHM Semiconductor: BH1745NUC-E2