Uninterruptible Power Supplies S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time from external to internal power. When utility power fails, your critical load remains supported by a seamless flow of power. Rack or tower configurable, the SolaHD S4KC UPS offers customers a higher power factor, longer battery life, higher reliability and reduced cost of ownership. Housed in a slim 2U package, the SolaHD S4KC protects equipment from virtually all power disturbances due to blackouts, brownouts, sags, surges or noise interference. The UPS includes internal batteries. Optional, matching external battery cabinets, also in a slim 2U (3.5") size, offer extended battery runtime. ENPC The LED display indicates battery capacity, percentage of UPS load, battery operation, bypass operation and UPS fault condition. The rack-tower models are also supplied with securing flanges and rack slide mounting hardware is available separately, if required. Units can be easily hardwired by removing the attached line cord and receptacle plate. All units include a conduit knockout cover in the box. Applications * Industrial Automation Systems * Critical Microprocessors and PC Based Systems * Robotics and Process Control * Programmable Logic Controllers (PLC) * Mission Critical and High Speed Networks * Enterprise Telecommunication Systems * Pharmaceutical and Medical Diagnosis Equipment * Printing and Publishing Machinery Features * Hardwire capability for permanent installation * Small 2U height maximizes available space * Input and output noise suppression * Higher output power factor of 0.90 * PWM (pulse-width modulation) inverter reduces output voltage distortion * Add on batteries for extended back-ups * Integral sealed non-spillable batteries * Hot swappable user replaceable battery * Automatic restart E179213 * Automatic and manual battery test * Rack-mount or stand-alone tower mounting *Units are field configurable with a PC as a frequency converter (bypass will be disabled) * Select S4KC models use an average of 35% less energy than their standard counterparts * Select S4KC models provide continuous uptime for the connected equipment, with capacity and battery back-up delivered in cabinets that use 2U of rack space * Integral dynamic bypass reduces shutdowns * Compatible with most standby generators * Two year limited warranty Certifications and Compliances All Models * ABS Type Approved * RoHS Compliant * ISTA Procedure 1A S4K2U-C, S4K2U3000-5C: * Listed, UPS Equipment - UL 1778 - CSA C22.2 No. 107.3 S4K2U-C: * ENERGY STAR certified: - 700, 1000, 1500, 2000, 3000 VA 120V input S4K2U-5C: * : EC/EN/AS 62040-1-1:2008 * EAC: TR CU 004/2011 - Technical Regulation of Custom Union "On the safety of low-voltage equipment" Note: The securing flanges do not support the weight of the UPS. Rack slides or shelves are required (sold separately). EAC applies only to certain CE models. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 75 Uninterruptible Power Supplies Selection Table - S4K2U-C & S4K2U-5C Tower/Rack-Mount Models Capacity (VA/W) Catalog Number Typical Back-up Times * (minutes) Input Plug/Output Receptacle Approx. Ship Weight - lbs (kg) 700/630 S4K2U700-C 11/27 5-15P / (6) 5-15R 1000/900 S4K2U1000-C 7/17 5-15P / (6) 5-15R 1500/1350 S4K2U1500-C 4/11 5-15P / (6) 5-15R 57.3 (26.00) 2000/1800 S4K2U2000-C 3/11 5-20P / (6)5-20R (15/20 amp type) 61.7 (28.00) 3000/2700 S4K2U3000-C 3/11 L5-30P / (5)5-20R (15/20 amp type): (1) L5-30R 70.5 (32.00) 120 Vac, 50/60 Hz Models 52.9 (24.00) 230 Vac, 50/60 Hz International Models 1000/900 S4K2U1000-5C 6/17 IEC 320-C14 / (6) IEC 320/C13 44.0 (20.00) 2000/1800 S4K2U2000-5C 3/11 IEC 320-C20 / (6) IEC 320-C13 61.7 (28.00) 3000/2700 S4K2U3000-5C 3/11 IEC 320-C20 / (6) IEC 320-C13 (1) IEC 320-C19 70.5 (32.00) * Full/Half Load (in minutes) at rated wattage. 76 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies S4K2U-C, 120 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number S4K2U700C S4K2U1000C S4K2U1500C S4K2U2000C S4K2U3000C dimensions, d x w x h, in. (mm) Unit Shipping 19.70 x 16.90 x 3.40 (500.4 x 430.0 x 86.4) 23.70 x 16.90 x 3.40 (602.0 x 430.0 x 86.4) 25.50 x 23.90 x 10.60 (648.0 x 607.1 x 270.0) 29.40 x 23.40 x 10.60 (747.0 x 594.4 x 270.0) weight, lbs. (kg) Unit 37.0 (16.80) 51.1 (23.20) 51.1 (23.20) 71.4 (32.40) Shipping 44.1 (20.00) 57.3 (26.00) 57.3 (26.00) 79.4 (36.00) input ac Parameters 120 Vac nominal; variable based on output load Voltage Range (typical) 90% to 100% Loading 90 Vac/140 Vac 102 Vac/140 Vac 70% to 90% Loading 86 Vac/140 Vac 96 Vac/140 Vac 30% to 70% Loading 77 Vac/140 Vac 84 Vac/140 Vac 0% to 30% Loading 60 Vac/140 Vac 60 Vac/140 Vac 0.99 Power Factor 40 Hz to 70 Hz; auto sensing Frequency Input Power Cord * 10 ft. attached with NEMA 5-15P plug 10 ft. attached with NEMA 5-20P plug 10 ft. attached with NEMA L5-30P plug 5-20R x 6 L5-30R x 1 + 5-20R x 6 output ac parameters 5-15R x 6 Output Receptacles * 110/115/120/127 Vac (user-configurable) 3% Voltage Sine wave Waveform Utility (Vac) Mode Overload 200% for 2 seconds; 150% for 50 seconds with transfer to bypass 0.90 Power Factor battery Valve-regulated, non-spillable, lead acid Type Qty x V x Rating Battery Mfr./Part Number Recharge Time 4 x 12 V x 5.0 Ah 4 x 12 V x 7.2 Ah YUASA/NPH5-12; CSB/HR 1221W Panasonic/UP- RW1245; CSB/UPS12460F2 4 x 12 V x 9.0 Ah 6 x 12 V x 9.0 Ah Panasonic/UP-RW1245; CSB/UPS12460F2 3 hours to 90% capacity after full discharge with 100% load until UPS auto shutdown (internal batteries only) Environmental Requirements Operating Temperature Storage Temperature Relative Humidity 0C to +40C; See Operating Temperature Parameters -15C to +50C 0% to 95%, non-condensing Operating Elevation Up to 10,000 ft. [3,000 m] Storage Elevation 50,000 ft. [15,000 m] max. Notes: * Input power cord and output receptacles can be removed for hardwired applications. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 77 Uninterruptible Power Supplies S4K2U-C, 120 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications - continued Catalog Number Audible Noise S4K2U700C S4K2U1000C S4K2U1500C <43 dBA max. @ 3 ft. [1 m] front & sides; <46 dBA max. @ 3 ft. [1 m] rear <45 dBA max. @ 3 ft. [1 m] front & sides; <50 dBA max. @ 3 ft. [1 m] rear S4K2U2000C <46 dBA max. @ 3 ft. [1 m] front & sides; <45 dBA max. @ 3 ft. [1 m] rear S4K2U3000C <48 dBA max. @ 3 ft. [1 m] front & sides; <48 dBA max. @ 3 ft. [1 m] rear Standards FCC Part 15, Class A EMC Operating Temperature Parameters Ambient Temperature Maximum output power factor derating at maximum load 78 +25C to +30C +30C to +35C +35C to +40C 100% to 93% 93% to 86% 86% to 79% Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies S4K2U-5C, 230 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number S4K2U1000-5C S4K2U2000-5C S4K2U3000-5C dimensions, d x w x h, in. (mm) Unit Shipping 19.60 x 16.90 x 3.30 (497.0 x 430.0 x 85.0) 23.70 x 16.90 x 3.30 (602.0 x 430.0 x 85.0) 28.20 x 22.40 x 10.30 (717.0 x 570.0 x 262.0) 28.20 x 22.40 x 10.30 (717.0 x 570.0 x 262.0) weight, lbs. (kg) Unit 37.0 (16.80) 51.1 (23.20) 71.4 (32.40) Shipping 44.1 (20.00) 57.3 (26.00) 79.4 (36.00) input ac Parameters 230 Vac nominal; variable based on output load Voltage Range (typical) 90% to 100% Loading 177 Vac/280 Vac 196 Vac/280 Vac 70% to 90% Loading 168 Vac/280 Vac 184 Vac/280 Vac 30% to 70% Loading 150 Vac/280 Vac 161 Vac/280 Vac 0% to 30% Loading 115 Vac/280 Vac 115 Vac/280 Vac 0.99 Power Factor 40 Hz to 70 Hz; auto sensing Frequency Input Power Receptacle * IEC 320 C14 IEC 320 C20 output ac parameters IEC 320 C13 x 6 Output Receptacles * IEC 320 C13 x 6; IEC 320 C19 x 1 220/230/240 Vac (user-configurable) 3% Voltage Frequency 50 Hz or 60 Hz Waveform Sine wave Overload 200% for 2 seconds; 150% for 1 minute with transfer to bypass 200% for 2 seconds; 150% for 50 seconds with transfer to bypass 200% for 2 seconds; 150% for 55 seconds with transfer to bypass 0.90 Power Factor battery Valve-regulated, non-spillable, lead acid Type Qty x V x Rating Battery Mfr./Part Number Recharge Time 4 x 12 V x 5.0 Ah 4 x 12 V x 9.0 Ah YUASA/NPH5-12; CSB/HR 1221W 6 x 12 V x 9.0 Ah Panasonic/UP-RW1245; CSB/UPS12460F2 3 hours to 90% capacity after full discharge with 100% load until UPS auto shutdown (internal batteries only) Environmental Requirements Operating Temperature 0C to +40C; See Operating Temperature Parameters Storage Temperatures -15C to +50C Relative Humidity 0% to 95%, non-condensing Operating Elevation Up to 3,000 m [10,000 ft.] Storage Elevation 15,000 m [50,000 ft.] max. Notes: * Input power cord and output receptacles can be removed for hardwired applications. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 79 Uninterruptible Power Supplies S4K2U-5C, 230 Vac, 50/60 Hz Tower/Rack-Mount Models Specifications Catalog Number Audible Noise S4K2U1000-5C S4K2U2000-5C <43 dBA max. @ 1 m [3 ft.] front & sides; <46 dBA max. @ 1 m [3 ft.] rear S4K2U3000-5C <48 dBA max. @ 1 m [3 ft.] front & sides; <48 dBA max. @ 1 m [3 ft.] rear Standards EMC IEC/EN/AS 62040-2 2 Edition = CISPR22 Class A; IEC62040-2 2nd Edition nd Operating Temperature Parameters Ambient temperature Maximum output power factor derating at maximum load 80 +25C to +30C +30C to +35C +35C to +40C 100% to 93% 93% to 86% 86% to 79% Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies External Battery Cabinets Specifications Catalog Numbers Used with UPS models S4K2U48BATC S4K2U96BATC S4K2U700C, S4K2U1000C (-5), S4K2U1500C, S4K2U2000C (-5) S4K2U3000C (-5) dimensions, d x w x h, in. (mm) Unit Shipping 19.70 x 16.90 x 3.40 (500.4 x 430.0 x 86.4) 23.70 x 16.90 x 3.40 (602.0 x 430.0 x 86.4) 24.30 x 22.40 x 10.30 (617.2 x 570.0 x 262.0) 28.20 x 22.40 x 10.30 (717.0 x 570.0 x 262.0) weight, lbs. (kg) Unit 70.5 (32.00) 93.5 (42.40) Shipping 77.2 (35.00) 101.4 (46.00) battery Type Qty x V x Rating Battery Mfr./Part Number Back-up Time Valve-regulated, non-spillable, lead acid 2 x 4 x 12 V x 9.0 Ah 2 x 6 x 12 V x 9.0 Ah Panasonic/UP-RW1245; CSB/UPS12460F2 Battery Back-up Times Chart Environmental Requirements Operating Temperature 0C to +40C Storage Temperatures -15C to +50C; High ambient temperatures will reduce battery life Relative Humidity 0% to 95%, non-condensing Operating Elevation Up to 10,000 ft. [3,000 m] Storage Elevation 50,000 ft. [15,000 m] max. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 81 Uninterruptible Power Supplies S4K2U-C Battery Back-up Times Model Rating Number of Batteries/Cabinets Load % of Capacity 700 VA 1000 VA 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 105 61 37 32 27 22 18 15 13 11 426 302 163 144 125 106 94 78 69 60 480 433 327 265 201 164 153 142 131 120 480 461 438 344 322 300 213 189 163 155 480 480 457 441 424 336 318 301 213 197 90 37 30 23 17 14 11 9 8 7 332 165 137 108 92 74 61 49 40 38 456 331 222 166 152 137 122 105 95 79 480 441 336 305 209 167 157 146 135 124 480 459 435 339 316 221 199 166 158 149 1500 VA 2000 VA 3000 VA 92 38 23 16 12 9 7 5 4 3 303 140 96 66 49 38 33 28 23 20 431 207 150 124 97 75 61 50 41 38 455 326 197 155 136 111 96 78 68 56 480 424 308 192 157 142 126 107 95 79 82 38 23 16 12 9 7 5 4 3 224 137 95 66 49 41 34 27 23 21 427 202 149 124 98 76 62 50 45 41 452 323 196 155 136 112 98 79 70 60 466 421 307 192 158 143 128 109 97 81 Back-up Time in Minutes Internal battery Internal battery + 1 external battery cabinet Internal battery + 2 external battery cabinets Internal battery + 3 external battery cabinets Internal battery + 4 external battery cabinets 123 52 34 23 18 14 11 9 7 6 335 162 129 96 72 54 46 38 34 31 451 318 187 151 131 107 91 74 64 53 480 426 312 198 160 145 130 111 99 83 480 446 341 309 204 164 153 141 130 112 Note: Run times in this table are approximate. They are based upon new, fully charged standard battery modules at a temperature of 25C (77F) with 100% resistive UPS loading. Run times listed above can vary by +/-5% due to manufacturing variances of the individual batteries 82 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies S4K2U-C Battery Back-up Times - continued Model Rating Number of Batteries/Cabinets Load % of Capacity 700 VA 1000 VA 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 480 480 464 451 438 424 343 329 315 300 480 480 480 462 451 440 428 370 336 324 480 466 446 427 341 322 303 212 193 166 480 480 458 442 426 342 326 309 221 204 1500 VA 2000 VA 3000 VA 480 441 333 225 188 158 145 133 120 104 480 452 422 319 216 185 159 148 137 126 480 439 332 225 190 159 147 135 122 107 480 450 421 319 218 188 160 149 139 129 Back-up Time in Minutes Internal battery + 5 external battery cabinets Internal battery + 6 external battery cabinets 480 458 432 333 306 207 167 158 148 139 480 467 445 422 327 304 208 184 161 153 Note: Run times in this table are approximate. They are based upon new, fully charged standard battery modules at a temperature of 25C (77F) with 100% resistive UPS loading. Run times listed above can vary by +/-5% due to manufacturing variances of the individual batteries Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 83 Uninterruptible Power Supplies S4K2U-5C Battery Back-up Times Model Rating Number of Batteries/Cabinets Load % of Capacity 1000 VA 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 91 38 31 23 17 14 11 9 8 6 334 166 138 108 92 72 56 48 40 37 457 333 224 166 151 135 113 103 92 78 480 442 337 305 208 166 155 144 132 122 480 460 436 340 315 218 195 165 156 147 2000 VA 3000 VA Back-up Time in Minutes Internal battery Internal battery + 1 external battery cabinet Internal battery + 2 external battery cabinets Internal battery + 3 external battery cabinets Internal battery + 4 external battery cabinets 81 37 23 16 12 9 7 5 4 3 222 137 94 66 49 39 34 28 23 20 426 201 149 124 97 75 61 50 41 38 451 322 195 154 136 111 96 78 68 56 466 421 306 192 157 142 127 107 95 80 91 39 23 16 12 9 7 5 4 3 302 139 95 66 48 41 34 27 23 21 431 205 150 124 97 76 63 50 45 41 455 325 196 155 136 112 98 79 70 60 480 423 307 192 157 143 128 109 97 81 Note: S4K2U-5C models are not available in 700VA or 1500VA. Run times in this table are approximate. They are based upon new, fully charged standard battery modules at a temperature of 25C (77F) with 100% resistive UPS loading. Run times listed above can vary by +/-5% due to manufacturing variances of the individual batteries 84 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Uninterruptible Power Supplies S4K2U-C Battery Back-up Times - continued Model Rating Number of Batteries/Cabinets Load % of Capacity 1000 VA 2000 VA 3000 VA Back-up Time in Minutes Internal battery + 5 external battery cabinets Internal battery + 6 external battery cabinets 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 480 467 447 428 341 320 227 208 189 164 480 480 458 442 426 341 323 306 217 201 480 438 331 224 189 158 146 133 120 104 480 450 420 319 217 186 159 148 137 126 480 440 332 225 189 159 147 135 122 106 480 452 421 319 217 187 160 150 139 128 Note: S4K2U-5C models are not available in 700VA or 1500VA. Run times in this table are approximate. They are based upon new, fully charged standard battery modules at a temperature of 25C (77F) with 100% resistive UPS loading. Run times listed above can vary by +/-5% due to manufacturing variances of the individual batteries Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 85