www.bitechnologies.com
MAGNETIC COMPONENTS SELECTOR GUIDE 2006 EDITION
We reserve the right to change specifications without prior notice.
66
HM90-24240 Flyback 300kHz 60W 5 1 23.5 0.47 100.0 10.0 – 1000Vac
48V to 23V 5A
HM90-29240 Flyback 300kHz 60W 5 1 23.5 0.47 100.0 10.0 – 1000Vac
48V to 23V 5A
HM90-27141 Half Bridge 100kHz 125W 8 1:1 140.0 0.40 35.0 3.5 3.5 1200Vdc
48V to 5V 25A
HM90-30181 Forward 300kHz 55W 10 2:3 180.0 0.40 54.0 5.0 9.0 1500Vdc
48V to 5V 8A/3.3V 4.5A
Specifications
Pri, P1 Leakage DCR(3)
Inductance(1) Inductance(2) mΩ Max. Pri-Sec
(µH) (µH) Isolation
Pri Sec Min. Typ. P1 S1 S2
• Operating Temperature Range -25°C to +125°C
• Ambient Temperature, Maximum 85°C
Electrical / Environmental
Surface Mount Planar Transformers
Notes: (1) Inductance is measured at 100kHz. 0.1V without DC current.
(2) Leakage inductance is measured at P1 with all other windings shorted.
(3) DC resistance is measured at 25°C.
Outline Dimensions (mm) / Schematics
HM90-24240
Top View Side View Recommended PCB Pattern Schematic
HM90-29240
Top View Side View SchematicRecommended PCB Pattern
Part Number Power Rating
Turns Ratio