Product Specification 108-79233 10 May 2007 Rev. A1 1 TYPEMODEL 1.1 3-1419145-2 OSA-SS-205DM3,000 1.2 OUTLINE As per Customer Drawing sheet 1.3 CONTACT DN.O ARRANGEMENT 1.4 CONTACT 2 Ag-GS MATERIAL Ag-GS Clad SAFETY STANDARD 2.1 Conform with Japan Product Safety Electrical Appliance & Materials law 2.2 FOREIGN 3 STANDARD Recognized by COIL RATING 3.1 DCV RATED VOLTAGE 3.2 COIL RESISTANCE 3.3 0.53W NORMINAL OPERATING POWER 3.4 about 0.53W MAX. ALLOWABLE COIL VOLTAGE 130% of rated coil voltage (at 23) 213-8535 3-5-8 1 of 6 Tyco Electronics EC K.K. (3-5-8 Hisamoto Takatsu-ku Kawasaki, 213-8535) This document is subject to change. Call local Tyco Electronics for the latest revision. (c) Copyright 2007 by Tyco Electronics EC K.K. All rights reserved. * : Trademark Product Specification 4 108-79233 CONTACT SPECIFICATION 4.1 CONTACT RATING Load Inrush current (A)ACV (A)DC V L/Rms 4.2 curry current Cut off current RATED CONTACT CURRENT 4.3 1 ( reference MIN. APPLICABLE LOAD 4.4 MAX. IN-RUSHING CURRENT: 5 ACV A Cos=1 15ms 250VDC 9A Cos=1 for 15 milli seconds Max. PERFORMANCE 5.1 CONTACT RESISTANCE 5.2 OPERATE VOLTAGE 5.3 RELEASE VOLTAGE 5.4 OPERATE TIME 5.5 RELEASE TIME 5.6 DC6V A 50 Max. (at initial stage) voltage drop test method 6VDC 1A 3.75VDC Max. of rated voltage. (at 23) 0.50VDC Min. of rated voltage. (at 23) 20 20ms Max. at rated voltage. 10 10ms Max. at rated voltage Endurance (1) ELECTRICALLY (2) MECHANICALLY (A) Contact rate A: 10 10 100,000ops. Min. (10 ops/minute) 500 300 5,000,000 ops. at no load. (300 ops./minute) 5.7 mA DIELECTRIC STRENGHT (Leak current: 1mA) (1) BETWEEN CONTACTS (2) 1,000VAC 1 1,200VAC 1 1,000VAC for 1 minute or 1,200VAC for 1 second. 4,000VAC 1 4,800VAC 1 BETWEEN COIL TO CONTACTS 5.8 INSULATION RESISTANCE 5.9 SURGE RESISTIVENESS Rev. A1 4,000VAC for 1 minute or 4,800VAC for 1 second. 500VDC 1,000M Between contacts and coil to contact 1,000M Min. at 500VDC 7kV(1.2/50s) Between coil to contact. 7kV (1.2/50s) 2 of 6 Product Specification 108-79233 5.10 TEMPERATURE RISE (1) COIL 55 55K Max. by resistance method when the rated current is provided to contact and 110% of rated voltage is supplied to relay coil. (2) CONTACT 5A 50 50K Max. by temperature measuring method at Contact: 5A, Coil: rated voltage 5.11 VIBRATION (1) ERROR OPERATION 1.5mm 1055Hz 3 5 1ms No error operation than 1ms Max. when vibrate it from 3 directions for 5 minutes. (Amplitude 1.5mm. 10 - 55Hz) (2) ENDURANCE 1.5mm 1055Hz 3 2 No construction trouble when vibrate it from 3 directions for 2 hours. (Amplitude 1.5mm. 10 - 55Hz) 5.12 SHOCK (1) ERROR OPERATION 98ms 11ms 3 3 ms No error operate by contact more than 1ms Max. when shocks it from 3 directions 3 times. (at Peak acceleration 98 m/s (2) ENDURANCE 980ms 6ms 3 3 No construction trouble when shocks is from 3 directions 3 times. (at Peak acceleration 980 m/s 5.13 Duration 11ms.) Duration 6ms.) 5N 10 TERMINAL STRENGTH No construction and exterior trouble when pull and push into any terminals by 5N for 10sec. 5.14 85 240 2 THERMAL PROOF Not any trouble on construction and characteristic when leave in 85 240h After that, leave it in standard condition for 2 hours. 5.15 40 240 2 COLD PROOF Not any trouble on construction and characteristic when leave in -40 240h After that, leave it in standard condition for 2 hours. Rev. A1 3 of 6 Product Specification 5.16 108-79233 40 90RH 24 2 10M HUMIDITY PROOF Insulation resistance 10M Min. Not any troubles on construction and characteristic when leave in 40 90% 24h. After that, leave it in standard condition for 2 hours. 5.17 (85) 0.5 (-40) 0.5 1 100 2 THERMAL SHOCK Not any troubles on construction and characteristic when leave it in -40 and 85 temp. room for 0.5 h each. That is one cycle. After 100 cycles has done, leave it on standard condition for 2 hours. 5.18 3505 3 2605 10 SOLDERING THERMAL Not any troubles on construction and characteristic. When dipped into soldering bath 3505 3sec. or 2605 10sec. 5.19 SOLDERABILITY 6 260 5 Not any problems solder dipped at 260 5 sec. STANDARDS TEST CONDITION 6.1 TEMPERATURE 6.2 RH HUMIDITY 6.3 DIRECTON OF MEASUREMENT 7 Terminals down position is standard position. OPERATING CONDITION 7.1 TEMPERATURE 7.2 (On conditions without freezing and dew condensation) RH HUMIDITY 7.3 MOUNTING DIRECTION Rev. A1 Terminal down position is standard position 4 of 6 Product Specification 8 108-79233 STORAGE CONDITION 8.1 TEMPERATURE 8.2 (On conditions without freezing and dew condensation) RH HUMIDITY 8.3 ENVIRONMENT (1) Store in locations where the product or container is not expose to corrosive gas such as hydrogen sulfide gas or salty air. (2) Store in location where no visible dust exists. (3) Store in location not subject to direct sunlight. 9 other Rev. A1 5 of 6 Product Specification 108-79233 10 Change Profile A1 A O1 O LTR Rev. A1 Logo Revise Standard Temp.2023 Revise Company Logo New Issue REVISION RECORD EC-FK00-0176-03 EC-FK00-0061-02 ECN May 10, 2007 July 18, 2006 December19, 2003 April30,2002 DATE 6 of 6