Rated operational current 240 V IeA 1
240 V Contacts Quantity 1
DC−23A, motor load switch L/R
= 15 ms
24 V
Rated operational current IeA 10
Contacts Quantity 1
48 V
Rated operational current IeA 10
Contacts Quantity 2
60 V
Rated operational current IeA 10
Contacts Quantity 3
120 V
Rated operational current IeA 5
Contacts Quantity 3
240 V
Rated operational current IeA 5
Contacts Quantity 5
DC−13, Control switches L/R =
50 ms
Rated operational current IeA 10
Voltage per contact pair in series V 32
Control circuit reliability at 24 V
DC, 10 mA Fault probability HF< 10 −5, < 1 fault in 100000
operations
Notes
Notes For mechanical shock
resistance: T3.../I... >12g
Applies to T0(3).../SVB:
isolating characteristics to
IEC/EN 60947 Ufor rated
operational voltage up to
500 V AC
Applies to rated
uninterrupted current Iu of
the contact: with
T5−4−8344/I5 max. 95 A
For terminal capacity solid,
stranded and flexible:
T0(3), (6), (8)...: Maximum
of 2 cross−section sizes
difference admissible
between 2 conductors
T5(B)−...: Maximum of 1
4