63www.burgess-switch.comburgess-switch@johnsonelectric.omBurgess switches
Miniature
Operating Characteristics
Actuating Operation Free Contact gap at
Actuator Reference Force Position Position total travel
Maximum Minimum
(N) (ozf) (mm) (in) (mm) (in) (mm) (in)
Plunger KB5FULS 3,00 10,8 16,8 0,66 19,3 0,76 2 T 3.0 2 T 0.12
1 At contact separation of 2 • 1,5 mm
K Lever KB5FKULS 2,25 8,0 19,2 0,76 26,0 1,02 2 T 3.0 2 T 0.12
KR Lever KB5FKRULS 2,25 8,0 31,0 1,22 36,5 1,40 2 T 3.0 2 T 0.12
Recommended minimum contact separation 2 • 1,5 mm (2 • 0,6) indicated when groove in plunger lines up with case.
Operating characteristics are specified from mounting holes.
Total travel: Plunger can be depressed flush with housing. The housing should not be used as an end stop.
Basic type KB5
Terminals F Faston 6.3 • 0.8 mm
Actuators No symbol, without lever
K Plain lever 33.5 mm
KR Roller lever 30.5 mm
Approvals ULS UL 100 k operations and CSA approved
Special Features /□□□□ Burgess specialise in customer specific solutions.
Additional product variants are available or can be provided.
If your requirements cannot be satisfied from the options listed,
please contact us.
Ordering Reference
Example: KB5 F K ULS
KB5