SFH 309
SFH 309 FA
NPN-Silizium-Fototransistor
Silicon NPN Phototransistor
Lead (Pb) Free Product - RoHS Compliant
SFH 309 SFH 309 FA
2007-04-02 1
Wesentliche Merkmale
Speziell geeignet für Anwendunge n im Bereich
von 380 nm bis 1180 nm (SFH 309) und bei
880 nm (SFH 309 FA)
Hohe Linearität
•3 mm-Plastikbauform im LED-Gehäuse
Gruppiert lieferbar
Anwendungen
Lichtschranken für Gleich- und
Wechsellichtbetrieb
Industrieelektronik
„Messen/Steuern/Regeln“
Typ
Type Bestellnummer
Ordering Code Typ
Type Bestellnummer
Ordering Codes
SFH 309 Q62702P0859 SFH 309 FA Q62702-P0941
SFH 309-3/4 Q62702P3592 SFH 309 FA-3/4 Q62702-P3590
SFH 309-4 Q62702P0998 SFH 309 FA-4 Q62702-P0178
SFH 309-4/5 Q62702P3593 SFH 309 FA-4/5 Q62702-P3591
SFH 309-5 Q62702P0999 SFH 309 FA-5 Q62702-P0180
SFH 309-5/6 Q62702P3594 SFH 309 FA-5/6 Q62702-P5199
Features
Especially suitable for applications from
380 nm to 1180 nm (SFH 309) and of 880 nm
(SFH 309 FA)
High linearity
•3 mm LED plastic package
Available in groups
Applications
Photointerrupters
Industrial electronics
For control and drive circuits
2007-04-02 2
SFH 309, SFH 309 FA
Grenzwerte
Maximum Ratings
Bezeichnung
Parameter Symbol
Symbol Wert
Value Einheit
Unit
Betriebs- und Lagertemperatur
Operating and storage temperature range Top; Tstg – 40 + 100 °C
Kollektor-Emitterspannung
Collector-emitter voltage VCE 35 V
Kollektorstrom
Collector curr ent IC15 mA
Kollektorspitzenstrom, τ < 10 μs
Collector surge current ICS 75 mA
Verlustleistung, TA = 25 °C
Total power dissipation Ptot 165 mW
Wärmewiderstand
Thermal resistance RthJA 450 K/W
SFH 309, SFH 309 FA
2007-04-02 3
Kennwerte (TA = 25 °C, λ = 950 nm)
Characteristics
Bezeichnung
Parameter Symbol
Symbol Wert
Value Einheit
Unit
SFH 309 SFH 309 FA
Wellenlänge der max. Fotoempfindlichkeit
Wavelength of max. sensitivity λS max 860 900 nm
Spektraler Bereich der Fotoempfindlichkeit
S = 10% von Smax
Spectr al range of sens itivity
S = 10% of Smax
λ380 1150 730 1120 nm
Bestrahlungsempfindliche Fläche (220 μm)
Radiant sensitive area A0.038 0.038 mm2
Abmessungen der Chipfläche
Dimensions of chip area L × B
L × W0.45 × 0.45 0.45 × 0.45 mm × mm
Abstand Chipoberfläche zu
Gehäuseoberfläche
Distance chip front to case surface
H2.4 2.8 2.4 2.8 mm
Halbwinkel
Half angle ϕ± 12 ± 12 Grad
deg.
Kapazität, VCE = 0 V, f = 1 MHz, E = 0
Capacitance CCE 5.0 5.0 pF
Dunkelstrom
Dark current
VCE = 25 V, E = 0
ICEO 1 (200) 1 (200) nA
2007-04-02 4
SFH 309, SFH 309 FA
Directional Characteristics Srel = f (ϕ)
Die Fototransistoren werden nach ihrer Fotoempfindlichkeit gruppiert und mit arabischen Ziffern
gekennzeichnet.
The phototransistors are grouped according to their spectral sensitivity and distinguished by
arabian figures.
Bezeichnung
Parameter Symbol
Symbol Wert
Value Einheit
Unit
-2 -3 -4 -5 -6
Fotostrom, λ = 950 nm
Photocurrent
Ee = 0.5 mW/cm2, VCE = 5 V
SFH 309:
Ev = 1000 Ix, Normlicht/
standard light A, VCE = 5 V
IPCE
IPCE
0.4
0.8
1.5
0.63
1.25
2.8
1.0
2.0
4.5
1.6
3.2
7.2
2.5
5.0
11.2
mA
mA
Anstiegszeit/Abfallzeit
Rise and fall time
IC = 1 mA, VCC = 5 V, RL = 1 kΩ
tr, tf56 789μs
Kollektor-Emitter-
Sättigungsspannung
Collector-emitter saturation
voltage
IC = IPCEmin1) × 0.3,
Ee = 0.5 mW/cm2
VCEsat 200 200 200 200 200 mV
1) IPCEmin ist der minimale Fotostrom der jeweiligen Gruppe.
1) IPCEmin is the min. photocurrent of the specified group.
SFH 309, SFH 309 FA
2007-04-02 5
Relative Spectral Sensitivity,
SFH 309 Srel = f (λ)
Total Power Dissipation
Ptot = f (TA)
Dark Current
ICEO = f (TA), VCE = 25 V , E = 0
λ
OHF01121
0
rel
S
400 600 800 1000 1200
20
40
60
80
%
100
nm
T
OHF01530
A
CEO
Ι
-1
10
10 0
10 1
10 2
10 3
-25
nA
0 25 50 75 100
˚C
Relative Spectral Sensitivity,
SFH 309 FA Srel = f (λ)
Photocurrent
IPCE = f (VCE), Ee = Parameter
Capacitance
CCE = f (VCE), f = 1 MHz, E = 0
V
OHF01528
CE
-2
10
CE
C
10
-1
10
0
10
1
10
2
0V
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
pF
Photocurrent
IPCE = f (Ee), VCE = 5 V
Dark Current
ICEO = f (VCE), E = 0
Photocurrent
IPCE/IPCE25° = f (TA), VCE = 5 V
V
OHF01527
CE
CEO
Ι
-3
10
10
-2
10
-1
10
0
10
1
0 5 10 15 20 25 30 35V
nA
T
OHF01524
A
0
-25
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0 25 50 75 100
Ι
PCE
PCE
Ι
25
C
2007-04-02 6
SFH 309, SFH 309 FA
Maßzeichnung
Package Outlines
Maße in mm (inch) / Dimensions in mm (inch).
0.6 (0.024)
0.4 (0.016)
4.0 (0.157)
3.6 (0.142)
ø3.1 (0.122)
ø2.9 (0.114)
4.1 (0.161)
3.9 (0.154)
5.2 (0.205)
4.5 (0.177)
3.5 (0.138)
6.3 (0.248)
5.9 (0.232)
1.8 (0.071)
1.2 (0.047)
29 (1.142)
27 (1.063)
2.54 (0.100)
spacing
0.7 (0.028)
0.4 (0.016)
Chip position
Collector (Transistor)
Area not flat
GEOY6653
0.4 (0.016)
0.8 (0.031)
Cathode (Diode)
SFH 309, SFH 309 FA
2007-04-02 7
Lötbedingungen
Soldering Conditions
Wellenlöten (TTW) (nach CECC 00802)
TTW Soldering (acc. to CECC 00802)
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organiza tion.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components 1 , may only be used in life-supp ort devices or systems 2 with the express written approval of OSRAM OS.
1 A critical componen t is a component usedin a life-support device or syste m whose failure can reasonably be expected
to cause the failure of that life-support devic e or system, or to a ffect its safety or e ffectiveness of that device or system.
2 Life support devices or syste ms are intended (a) to be implanted in the human body, o r (b) to support and/or maintain
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
OHLY0598
0
050 100 150 200 250
50
100
150
200
250
300
T
t
C
s
235 C
10 s
C... 260
1. Welle
1. wave
2. Welle
2. wave
5 K/s 2 K/s
ca 200 K/s
CC... 130100
2 K/s Zwangskühlung
forced cooling
Normalkurve
standard curve
Grenzkurven
limit curves