93
TRANSFORMERS /
RELAYSINDEX
TRANSFORMERS /
RELAYS
CLASS 2 TRANSFORMERS AND FAN CENTERS 94 – 98
Description Model(s) Page(s)
Class 2 Transformers .................................................................................... 90-T ....................................................................... 94
Class 2 Transformers .................................................................................... S82 / S84 ............................................................... 95
Fan Control Center ........................................................................................ 90-112 / 90-113 / 90-118E / 90-130 / 90-340 ......... 96 – 97
Blower Relay / Relay Transformer ................................................................. 8A04 / 8A05 ........................................................... 98
RELAYS 99 – 100
Description Model(s) Page(s)
Enclosed Relays ............................................................................................ 90-290Q Thru 90-295Q ......................................... 99
Heavy Duty Enclosed Relays ........................................................................ 90-360 Thru 90-486 ............................................... 100
DC POWER (CONTACTORS) 101 – 102
Description Model(s) Page(s)
DC Power Contactors (SPNO) ...................................................................... Type 70 / Type 120 ................................................ 101
DC Power Contactors (SPNO/SPDT)............................................................ Type 124 / Type 586 .............................................. 102
CLASS 2
TRANSFORMERS
90-T40S1 THRU 90-T75C3 24 VOLT SECONDARY
CLASS 2 TRANSFORMERS ENERGY LIMITING
For Industrial, Heating and Air Conditioning Controls Applications
SPECIFICATIONS
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L.lenumberE33334
FEATURES
•Colorcodedprimaryleads.
•Multi-mountstylesavailable.
90-T40F1
90-T75C3
MULTI-MOUNT (CLOSED CONSTRUCTION) UNIVERSAL MOUNTING WITH PLATE
Model
Number
Mars
Part No.
Jard
Part No. VA Hz Primary Connections Sec. Connections
90-T40M1 50302 4011M 40 50/60 120V Leads 24V Leads
90-T40M2 50303 4021M 40 50 / 60 208 / 240V Leads 24V Leads
90-T40M3 50304 4031M 40 60 120 / 208 / 240V Leads 24V Leads
90-T50M3 50314 5031M 50 60 120 / 208 / 240V Leads 24V Leads
FOOT-MOUNT (OPEN CONSTRUCTION)
Model
Number
Mars
Part No.
Jard
Part No. VA Hz Primary Connections Sec. Connections
90-T40F1 50352 4011F 40 50/60 120V Leads 24V Leads
90-T40F2 50353 4021F 40 50 / 60 208 / 240V Leads 24V Leads
90-T40F3 50354 4031F 40 60 120 / 208 / 240V Leads 24V Leads
90-T50F3 50308* 5031F 50 60 120 / 208 / 240V Leads 24V Leads
* 50308 is 50/60 Hz
FOOT-MOUNT (MANUAL RESET, OPEN CONSTRUCTION)
Model
Number
Mars
Part No.
Jard
Part No. VA Hz Primary Connections Sec. Connections
90-T50C3 50327 5041C 50 50 / 60 120 / 208 / 240V Leads 24V Leads
90-T60C3 50327 6041C 60 50 / 60 120 / 208 / 240V Leads 24V Leads
90-T75C3 50321 7541C 75 50 / 60 120 / 208 / 240V Leads 24V Leads
90-T100C4 50540 10041C 100 50/60 120 / 208 / 240
/ 480
Leads 24V Leads
TRANSFORMER LEAD COLOR CODING
Primary Side Secondary Side
Common 120V 208V 240V Common 24V
* Black White Red Orange Blue Yellow
*Blackiscommonwithrespecttothetransformerwinding,nottheexternalcircuit.
www.white-rodgers.com
94
TRANSFORMERS /
RELAYS
95
CLASS 2 TRANSFORMERS – ENERGY LIMITING
VariousStandardCongurationsofStepDownTransformers
Designed to Power 24 VAC Control Systems
FEATURES
•Energylimitingdesign,unaffectedbymomentaryshortcircuit.
•Continuedshortcircuitofsecondarywillcauseprimarywindingtoopenin1to2
minuteswithoutcreatingarehazard.
•Maximumambienttemperatureis150°F.
SPECIFICATIONS
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L.lenumberE33334
S84Z-90
S84A-410
Model Primary to Output Terminations
Number Secondary Voltages Rating Line Load
S84-11 120v to 25v 60Hz 40 VA 10leads Screw terminals
S84Z-90 120 / 208 / 240v to 25v 60Hz 40 VA 10leads Screw terminals
UNIVERSAL MOUNTED TYPES (Plate, Foot or Hub Mount)
Model Primary to Output Terminations
Number Secondary Voltages Rating Line Load
S84A-410 120v to 25v 60Hz 40 VA 10leads Screw terminals
PLATE MOUNTED TYPE
Model Primary to Output Terminations
Number Secondary Voltages Rating Line Load
S82A-310 120v to 25v 20 VA 10leads Screw / spade terminals
HUB MOUNT Class 2 Not Wet / Class 3 Wet(C.S.A.CertiedandU.L.Listed)
Model Primary to Output Terminations
Number Secondary Voltages Rating Line Load
S84A-310 120v to 25v 40 VA 10leads Screw / spade terminals
UNIVERSAL MOUNTED TYPES (Plate, Foot or Hub Mount)
Class 2 Not Wet / Class 3 Wet (C.S.A.CertiedandU.L.Listed)
CLASS 2
TRANSFORMERS
S84A-310
S82A-310
Indicates Canadian Model Number: call 1-800-305-6953 to order
TRANSFORMERS /
RELAYS
FAN CONTROL CENTER
RELAY & TRANSFORMER
90-112 THRU 90-130
FAN CONTROL CENTER
Transformer and Relay Combination for Easy Installation on a
4x 4Junction Box
SPECIFICATIONS
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L.lefancenterE73641
FEATURES
•Linevoltageconnectionspre-wired.
•EnergylimitingclassIItransformerdesign.
•Colorcodedpre-strippedleads.
•Lowvoltageconnectionsonterminalboard.
Approximate Overall Dimensions
21/8 x 17/8 x 21/4
90-112 THRU 90-130
U.L. Recognized
Model Number Replaces Relay On Description
90-340 90-112, 90-113, 90-117 DPDT Universal
90-118E, 90-119, 90-130 Plug-in Relay
REPLACEMENT RELAY FOR FAN CONTROL CENTER
90-340
Transformer Contact Ratings
Model Mars Primary Secondary 120 VAC (amps) 240 VAC (amps)
Number Number Voltage Hz Connections Voltage VA Connections Relay Full Load Locked Rotor Full Load Locked Rotor
90-112 24010 120 60 Color coded 24V 40 Terminal board DPDT 13.8 82.8 6.9 41.4
leads, with 5 screw
pre-stripped terminals
90-113 24013 120 60 Color coded 24V 40 Terminal board SPDT 13.8 82.8 6.9 41.4
leads, with 5 screw
pre-stripped terminals
90-118E 24012 120 60 Color coded 24V 40 Terminal board SPNO / 13.8 82.8 6.9 41.4
leads, with 5 screw SPNC
pre-stripped terminals
90-130 24010 120 / 50 / 60 Color coded 24V 40 Terminal board DPDT 13.8 82.8 6.9 41.4
208 / 240 leads, with 5 screw
pre-stripped terminals
BROWN N.C.
RED
BLACK
RED N.C.
CONTACT
COMMON
CONTACT
COMMON
CONTACT
COMMON
CONTACT
COMMON
CONTACT
COMMON
BLACK
C
Y
G
WHITE
W
R
COM
BLACK N.O.
COIL
BLACK
Y
RED N.O.
VIOLET
C
G
W
COIL
R
BLACK
G
BLACK
R
RED/YEL N.O.
120 V
60 HZ
90-112
120 V
60 HZ
90-118E
G
120 V
60 HZ
WHITE
R
W
C
208/240 V
60 HZ
Y
W
G
WHITE
R
W
BLACK
BROWN N.C.
BLACK
BROWN N.C.
RED N.O.
Y
C
COIL
240
RED
208
BLUE
WHITE
90-119
Y
BLACK
YELLOW N.C.
COIL
90-113
RED N.O.
120 V
60 HZ
BLACK
C
RED
COIL
90-117
RED N.O.
*
* Black is common with respect to transformer
winding, not external circuit.
Note: Record the lead wire color with it's
corresponding terminal for future reference.
Unused transformer input leads must be
insulated.
120
WHITE
BLACK
BROWN N.C.
BLACK
COIL
VIOLET
CONTACT
COMMON
CONTACT
COMMON
YELLOW N.C.
RED/YEL N.O.
240
RED
BLUE
Y
W
R
RED N.O.
208
120/208/240 V 50/60 HZ
60 HZ
C
G
COM
90-130
*
When the fan relay transformer is energized and the thermostat completes the con-
nection from R to G the fan relay coil energizes. Line voltage power applied to contact
commonpathtravelstoselectedblowerspeedtap.AdditionalterminalYandWare
isolated tie point terminals to connect thermostat wiring to compressor and furnace
(if required).
www.white-rodgers.com
96
TRANSFORMERS /
RELAYS
97
90-340 THRU 90-342 RELAYS – WR/RBM TYPE 91
A Two Pole Double Throw Semi-Enclosed Relay
90-340 Fits Fan Control Centers 90-112, 90-113, 90-118E and 90-119
SPECIFICATIONS
Temperature Range ................ -40°F to 130°F
Mechanical Life (no load) ............ 1,000,000 operations, 120 operations/min.
Electrical Life (rated load)............ 100,000 operations, 6 operations/min.
Loadtestmakinginrushratings(0.4to
0.5P.F.);breaking100%continuousrating
(0.65 to 0.8 P.F.)
Weight (approximate) ............... 6 oz
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . U.L.lenumberE12139
C.S.A.lenumberLR13360
Coils, Frequency................... 50 / 60 Hz
Coils, Insulation ................... Class B
Coils, Termination .................. 1/4QuickConnect
Coils, Operate..................... 85% of nominal coil voltage;
110% maximum safe operate
Coils, Duty Cycle .................. Continuous
FEATURES
•Easytoinstall.
•Suitedforuseinvendingmachines,appliances,heatingandairconditioning
applications and general purpose switching.
Approximate Overall Dimensions
21/8 x 17/8 x 21/4
2 POLE
SWITCHING RELAYS
Voltage: 24 VAC
Cycle: 50 / 60 Hz
Volt: Amps
Inrush: 21.5
Sealed: 9.5
Resistance: 17.5 ± 10%
COIL RATING
12FLA / 60LRA
125 VAC
6FLA 35LRA
250 / 277 VAC
15A 277 VAC RES
1/2HP 125 / 250 VAC
CONTACT RATINGS
6
2
1
4
3
5
1.640
1.859
2.109 2.078
2.375
2.156
2.218
90-340
Model Coil Voltage Terminals Terminals COIL DATA
Number (50 / 60 Hz) 1-2-3 4-5-6 DC Res. MA Nom. VA Inrush VA
90-340 24 Power Power 17.5 334 9.5 22
90-341 115 / 120 Power Power 420 66 9.5 22
90-342 208 / 240 Power Power 1600 38 9.5 22
TWO POLE DOUBLE THROW (2PDT) Fits Fan Control Center Receptacles
?
PAGE
202
TRANSFORMERS /
RELAYS
BLOWER RELAY /
TRANSFORMERS
FAN RELAYS SPDT
For 24V AC Control of Blowers and Other Line Voltage Loads on
Heating, Cooling or Heating/Cooling Systems where 24V Power
Supply is Already Available
FEATURES
•Compactsize–1/2 conduit hub permits mounting to standard junction box.
•Provisionsformountingtoatsurface.
•Permitscontrolofsingleortwospeedfanmotor.
•5colorcoded,endstrippedleadsforeasywiring.
SPECIFICATIONS
Dimensions........................ 211/16H x 215/16W x 11/2D
Finish ............................ Grey
Mounting.......................... Mounting tabs or 1/2 conduit hub
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. listed and C.S.A. approved
8A04-1
RELAY/TRANSFORMER COMBINATIONS
DPST Relay Models Enclosed with a Transformer Capable of
Powering External Loads up to 35VA. Ideal for Use on Boilers without
Domestic Coil. Equally Adaptable for Zoned and Unzoned Systems
FEATURES
•Lowvoltagescrewterminals–colorcoded,endstrippedlinevoltageleads.
•Internaltransformercanpowerupto35VAexternalloads.
•Mountsto4x 4 junction box.
•Dustproofsteelcase.
SPECIFICATIONS
Dimensions........................ 41/4H x 23/4W x 23/4D
Finish ............................ Grey
Mounting.......................... To 4 x 4 junction box
Transformer ....................... 35 VA maximum connected external load
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. recognized and C.S.A. approved
Contact Ratings
Motor Rating Valves & Relays
120 VAC Terminals
Model Thermostat Full Locked V1 & V2
Number Input Voltage Switch Action Current Load Rotor 30 VAC 0.3-12v DC
8A05A-4 120 VAC, 60 Hz DPST 0.28A 10.0A/16.0A 60.0A/96.0A
8A05A-101 120 VAC, 60 Hz DPST 0.13A 8.0A/14.0A 48.0/84.0A
Contact Ratings
Model Coil Coil N.O. (Black-Red) N.C. (Black-Brown)
Number Input Voltage Switch Action Current 120 VAC 240 VAC 120 VAC 240 VAC
8A04-1 24 VAC, 60 Hz SPDT 0.28A 16.0 FLA/96.0 LRA 8.0 FLA/48.0 LRA 9.8 FLA/58.8 LRA 6.9 FLA/41.4 LRA
Indicates Canadian Model Number: call 1-800-305-6953 to order
www.white-rodgers.com
98
TRANSFORMERS /
RELAYS
99
Approximate Overall Dimensions
23/8 x 15/8 x 11/2
90-290Q THRU 90-295Q RELAYS – WR/RBM TYPE 84
Used for Switching Single or Two Speed Fan Motors, Solenoids,
Relays, Resistive Loads and General Purpose Switching
SPECIFICATIONS
Temperature Range ................. -40°F to 150°F
Mechanical Life (no load) ............. 1,000,000 operations, 60 operations/min.
Electrical Life (rated load)............. 100,000 operations, 6 operations/min.
Loadtestmakinginrushrating(0.4to
0.5P.F.);breaking100%continuousrating
(0.64 to 0.8 P.F.)
Weight (approximate) ................ 2.5 oz.
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L.lenumberE12139orE22381
C.S.A.lenumberLR13360
Coils, Frequency.................... 50 / 60 Hz
Coils, Insulation .................... Class B
Coils, Termination ................... 1/4QuickConnect
Coils, Operate...................... 85% of nominal coil voltage;
110% maximum safe operate
Coils, Duty Cycle ................... Continuous
FEATURES
•Compact,totallyencloseddesign.
•Forheatingandcoolingapplicationsandgeneralswitching.
•Quiet,reliableandeconomical.
SINGLE POLE NORMALLY OPEN (SPNO), SINGLE POLE DOUBLE THROW (SPDT)
Inductive Resistive
8 Amps
Continuous
25 Amps. Inrush
CONTACT RATING 125 / 250 VAC
16 Amps
Continuous
SPNO
SPDT
WIRING DIAGRAMS
ENCLOSED
RELAYS
Model Number Coil Voltage AC
(50/60 Hz)
Res DC
OHMS
Coil Data Inrush
VASPNO SPDT Nom. Current MA Nominal VA Sealed
90-290Q 90-293Q 24 90 125 3 4
90-291Q 90-294Q 120 2,000 25 3 4
90-292Q 90-295Q 240 7,000 12.5 3 4
TRANSFORMERS /
RELAYS
HEAVY-DUTY
ENCLOSED RELAYS
90-360 THRU 90-486 RELAYS – WR/RBM TYPE 184
Heavy-Duty General Purpose Relay Operates in Any Position
SPECIFICATIONS
Temperature Range ................ -40°F to 150°F
Mechanical Life (no load) ............ 1,000,000 operations, 120 operations/min.
Electrical Life (rated load)............ 100,000 operations, 6 operations/min.
Loadtestmakinginrushrating(0.4to
0.5P.F.);breaking100%continuousrating
(0.65 to 0.8 P.F.)
Weight (approximate) ............... 2.3 oz.
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . U.L.lenumberE12139orE22381
C.S.A.lenumberLR13360
Coils, Frequency................... 50 / 60 Hz
Coils, Insulation ................... Class B
Coils, Termination .................. 1/4QuickConnect
Coils, Operate..................... 85% of nominal coil voltage;
110% maximum safe operate
Coils, Duty Cycle .................. Continuous
FEATURES
•Compact,totallyencloseddesign.
•Forheatingandcoolingapplicationsandgeneralswitching.
•Quiet,reliableandeconomical.
Model Number Coil Voltage AC
(50/60 Hz)
Res DC
OHMS
Coil Data Inrush
VASPNO SPDT SPNO/SPNC Nom. Current MA Nominal VA Sealed
90-360 90-370 90-380 24 77 125 3 4
90-362 90-372 90-382 120 2,000 25 3 4
90-374 90-384 240 6,050 12.5 3 4
90-466 90-476 90-486 277 10,300 10.8 3 4
SINGLE POLE NORMALLY OPEN, SINGLE POLE DOUBLE THROW (SPDT) ISOLATED CONTACTS (SPNO / SPNC)
Totally Enclosed Relay
Operates in Any Position
IsolatedCoilandMountingBracket
13
56
24
1.500
MAX.
1.265
MAX.
1.265
.500
1.842 2.156 2.670
.150 DIA.
Inductive Resistive
12 Amps. Continuous
60 Amps. Inrush 18 Amps.
@ 125 VAC Continuous
8 Amps. Continuous @ 277 VAC
48 Amps. Inrush
@ 250 VAC
CONTACT RATING
SPNO
SPDT
WIRING DIAGRAMS
SPNO / SPNC
www.white-rodgers.com
100
TRANSFORMERS /
RELAYS
101
TYPE 70 CONTACTORS – SPNO
Single Pole Normally Open Contact, Case is Dust Resistant and
Isolated from Ground
SPECIFICATIONS
Dimensions.......................... 2.47L x 3.48W x 2.40H
Weight ................................. 14 oz.
Temperature Range ................... -40°to+122°F
Terminations, Contacts ................. 5/16-24 UNF-2A thread
Terminations, Coil ..................... #10-32 UNF-2A thread
Recommended Mounting ................... Plunger vertical with cap down
Hardware Torque, Contact Terminal ........... 45-55 in. lbs.
Hardware Torque, Coil Terminal .............. 12-18 in. lbs.
Caution:Aback-upwrenchmustbeusedtoholdthebottomnutstationary.
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. 538 Recognized, File AU2138
“3A”=CoilGroundedtoCase
“4”=IsolatedCoil
Coil resistance in Ohms @ 25°C
Intermittent duty designs available.
TYPE 120 CONTACTORS – SPNO
Single Pole Normally Open Contact, Dust Resistant, Water Resistant
andCaseisIsolatedfromBracket
SPECIFICATIONS
Dimensions ......................... 2.13L x 2.88W x 3.09H(Std.Bracket)
Dimensions ......................... 2.50L x 3.00W x 3.03H (L-ShapedBracket)
Weight ................................. 6.0 oz.
Temperature Range, Intermittent Duty ..... -20°to+150°F
Temperature Range, Continuous Duty ..... -20°to+120°F
Terminations, Contacts ................. 5/16-24 studs, .495 min. length
Terminations, Coil ..................... #10-32, .451 min. length
Recommended Mounting ................... Coil terminals up or horizontal
Hardware Torque, Contact Terminal ........... 45-55 in. lbs.
Hardware Torque, Coil Terminal .............. 12-18 in. lbs.
Caution:Aback-upwrenchmustbeusedtoholdthebottomnutstationary.
Type 120 SPNO
DC POWER
CONTACTORS – SPNO
IntermittentDutyCycle=30seconds“ON”maximumand6minutes“OFF”
“4”=IsolatedCoil
Coil resistance in Ohms @ 25°C
InrushCurrent:Currentappliedwithintherst1/2secondofcontactclosure
Coilgroundedtobracket
NOTE: CAUTION must be used in coil selection for use in 12 volt
systems where battery charging may expose coil to continuous,
higher-than-rated voltage. 14 volt coils are recommended.
White-Rodgers will not be responsible for consequences of
misapplied solenoids.
WARNING – FIRE HAZARD
Must be installed in a dry and protected
place. Failure to protect solenoid from water
and other contaminants could result in Fire,
Property Damage, Serious Personal Injury,
or Death.
Type 70 SPNO
Model
Number
Duty
Cycle
Terminal
Type
Pole
Form
Bracket
Style
Coil
Voltage
D.C.
Coil
Resistance
(Ohms)
Contact
Material
Contact Rating (Amps) – Inductive Load
Voltage Normally Open
D.C. Continuous Inrush
70-111225 Continuous 3A SPNO Standard 12 16 Copper 12 80 150
70-111224 Continuous 4 SPNO Standard 12 16 Copper 12 80 150
70-117224 Continuous 4 SPNO Standard 24 60 Copper 24 50 50
70-120224 Continuous 4 SPNO Standard 36 114 Copper 36 50 50
Model
Number
Duty
Cycle
Terminal
Type
Pole
Form
Bracket
Style
Coil
Voltage
D.C.
Coil
Resistance
(Ohms)
Contact
Material
Contact Rating (Amps) – Inductive Load
Voltage Normally Open
D.C. Continuous Inrush
120-105711 Continuous 4 SPNO Standard 12 16 Silver Alloy 12 100 400
120-105851 Continuous 3A SPNO Standard 12 16 Silver Alloy 12 100 400
120-106131 Intermittent 4 SPNO Standard 12 6.0 Copper 12 80 400
120-106132 Intermittent 4 SPNO L 12 6.0 Copper 12 80 400
120-107112 Continuous 4 SPNO L 14 26.0 Silver Alloy 14 100 400
TRANSFORMERS /
RELAYS
Model
Number
Duty
Cycle
Terminal
Type
Bracket
Style
Coil
Voltage
D.C.
Coil
Resistance
(Ohms)
Contact
Material
Contact Rating (Amps) – Inductive Load
Voltage Normally Open Normally Closed
D.C. Continuous Inrush Continuous Inrush
124-105111 Continuous 4 Standard 12 13.2 Silver Alloy 12 150 400
124-305111 Continuous 6 Standard 12 13.2 Silver Alloy 12 150 400 50 100
124-114111 Continuous 4 Standard 24 53.0 Silver Alloy 24 150 400
124-314111 Continuous 6 Standard 24 53.0 Silver Alloy 24 150 400 50 100
124-117111 Continuous 4 Standard 36 120.0 Silver Alloy 36 100 400
124-317111 Continuous 6 Standard 36 120.0 Silver Alloy 36 100 400 50 100
TYPE 124 CONTACTORS
Single Pole Normally Open, or Single Pole Double Throw Contacts.
DustResistantandEndcapsareIsolatedfromBracket
SPECIFICATIONS
Dimensions, 124-105111,-114111,-117111 ..... 3.56L x 3.13W x 2.19H
Dimensions, 124-305111,-314111 ........... 4.69L x 3.13W x 2.19H
Weight, 124-105111,-114111,-117111 .......... 16.0 oz.
Weight, 124-305111,-314111 .................. 19.0 oz.
Temperature Range ...................... -40°to+149°F
Terminations, Contacts .................... 5/16-24 UNF-2A thread
Terminations, Coil ........................ #10-32 UNF-2A thread
Recommended Mounting ....................... Vertical plane with coil terminals up
Hardware Torque, Contact Terminal ............... 60 in. lbs. max.
Hardware Torque, Coil Terminal .................. 12-18 in. lbs.
Caution:Aback-upwrenchmustbeusedtoholdthebottomnutstationary.
Type 124
“4”=IsolatedCoil,SPNO
“6”=IsolatedCoil,SPDT
Coil resistance in Ohms @ 25°C
InrushCurrent:Currentappliedwithintherst1/2secondofcontactclosure
TYPE 586 CONTACTORS
Single Pole Normally Open, or Single Pole Double Throw Contacts.
WaterResistantandCaseisIsolatedfromBracket
SPECIFICATIONS
Dimensions, 586-114111,-117111 ........... 3.69L x 3.30W x 2.90H
Dimensions, 586-317111 .................. 4.61L x 3.30W x 2.90H
Weight, 586-114111,-117111 .................. 24.0 oz.
Weight, 586-317111 ......................... 26.0 oz.
Temperature Range ...................... -40°to+149°F
Terminations, Contacts .................... 5/16-24 UNF-2A thread
Terminations, Coil ........................ #10-32 UNF-2A thread
Recommended Mounting ....................... Vertical plane with coil terminals up
Hardware Torque, Contact Terminal ............... 60 in. lbs. max.
Hardware Torque, Coil Terminal .................. 12-18 in. lbs.
Type 586 SPNO
“4”=IsolatedCoil,SPNO
“6”=IsolatedCoil,SPDT
Coil resistance in Ohms @ 25°C
InrushCurrent:Currentappliedwithintherst1/2secondofcontactclosure
Ideal for 12V charging systems
NOTE: CAUTION must be used in coil selection for use in 12 volt
systems where battery charging may expose coil to continuous,
higher-than-rated voltage. 15 volt coils are recommended.
White-Rodgers will not be responsible for consequences of
misapplied solenoids.
DC POWER
CONTACTORS
Model
Number
Duty
Cycle
Terminal
Type
Bracket
Style
Coil
Voltage
D.C.
Coil
Resistance
(Ohms)
Contact
Material
Contact Rating (Amps) – Inductive Load
Voltage Normally Open Normally Closed
D.C. Continuous Inrush Continuous Inrush
586-105111 Continuous 4 Standard 12 21.0 Silver Alloy 12 200 600
586-108111 Continuous 4 Standard 15 32.8 Silver Alloy 15 200 600
586-114111 Continuous 4 Standard 24 84.0 Silver Alloy 24 200 600
586-117111 Continuous 4 Standard 36 189.0 Silver Alloy 36 200 600
586-120111 Continuous 4 Standard 48 336.0 Silver Alloy 36 200 600
586-314111 Continuous 6 Standard 24 53 Silver Alloy 24 200 600 100 200
586-317111 Continuous 6 Standard 36 120 Silver Alloy 36 200 600 100 200
www.white-rodgers.com
102
TRANSFORMERS /