1© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3051_C9T_RADIAL 3/29/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
One world. One KEMET
Benets
VDE Approved
Overpressure safety device
High capacitance density
Long lifetime
3-phase delta connections
Overview
The C9T capacitor is a polypropylene metallized lm
capacitor with a cylindrical, aluminium can-type design
lled with resin. It uses a 3-phase delta connection and
safety device FPU.
Applications
Typical applications power factor correction.
Aluminum Can Power Film Capacitors
C9T, 415 – 440 VAC, 3–Phase PFC
Part Number System
C9T S5 M D 6137 AAR X
Series Type
Rated Voltage
(VAC)
Terminal Style
Internal
Connection
Capacitance
Code (pF)
Internal Code Tolerance
C9T =
Cylindrical
Three-Phase
Capacitors
S = Slim 5 = 415
6 = 440
M = Screw
clamp Terminal
D = Delta Digits 2–4
indicate the
rst three
digits of the
capacitance
value. First
digit indicates
the number
of zeros to be
added.
AAR = Standard X = −5%/+10%
2© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3051_C9T_RADIAL 3/29/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Aluminum Can Power Film Capacitors
C9T, 415 – 440 VAC, 3–Phase PFC
Dimensions – Millimeters
10
10
Ø(D+4)
36±2
H±2
16±0.5
M12
19
44
Ø7
15
48
44
Ø D+/0.5
D H Mounting Stud
(M)
±0.5 ±2
75
160
M12 x 16
75
230
M12 x 16
75
280
M12 x 16
85
160
M12 x 16
85
230
M12 x 16
85
280
M12 x 16
Qualications
Reference Standards IEC 8311/2
Approved VDE-REG.Nr.F064
Protected 10,000 AFC 25°C to +70°C
General Technical Data
Reference Standards
IEC 608311/2
Approved VDE-REG.Nr.F064
UL810 compliant
Dielectric Polypropylene lm
Non–Inductive type winding
Climatic Category
25/D - IEC 608311
Maximum: 55°C
Highest mean over any period of 24 hours: 45°C
Highest mean over any period of one year: 35°C
Maximum Hot Spot Temperature +70°C
Endurance Test IEC 60831-2 IEC 60831–2 clause 17.117.2
3© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3051_C9T_RADIAL 3/29/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Aluminum Can Power Film Capacitors
C9T, 415 – 440 VAC, 3–Phase PFC
Electrical Characteristics
Rated Voltage Un = (see table) Vrms
Over Voltage
IEC 608311 clause 20:
1,10*UN – 8 hours in every 24 hours
1,15* UN – 30 minutes in every 24 hours
1,20* UN – 5 minutes in the lifetime
1,30* UN – 1 minutes in the lifetime
Capacitance Tolerance −5% +10% (X)
Mechanical Characteristics
Maximum Torque: 6 [N*m] for Terminal screw
12 [N*m] for M12 Bolt
Installation Whatever position
Aluminum deck with self extinguishing UL94 V0 plastic cover
Life Expectancy
Life Expectancy 100,000 hours at Urms with Ths ≤ 70°C
Capacitance drop at end of life −5% (typical)
Failure rate IEC 61709 300*10–9 components/hours
Test Method
Test voltage term to term (Utt) 2,15*Urms for 2 seconds at 25°C
Test voltage term to case (Utc) 3600 V – 50 Hz for 2 seconds
Relative Humidity
Annual average ≤ 80% at 24°C
On 30 days/year permanently 100%.
On other days occasionally 90%.
Dewing not admitted
Capacitance Deviation in
Temperature Range (−40..+50°C) ±1.5% maximum on capacitance value at 20°C
Damp Heat IEC 60068–2–78
Change of Temperature IEC 60068214
Vibration Strength IEC 60068–2–6
NOTICE: Care should be taken to ensure that there still is electrical clearance of 15 mm between terminations and other live or earthed parts above the
capacitor, in case of safety device activation.
4© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3051_C9T_RADIAL 3/29/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Aluminum Can Power Film Capacitors
C9T, 415 – 440 VAC, 3–Phase PFC
Table 1 – Ratings & Part Number Reference
Capacitance
Value Voltage Dimensions
(mm)
Rated
Current Qn Operating
Frequency dV/dt Packaging
Quantity Part Number
μF VAC Ø H A kVAr Hz V/μs
3 x 31.1 415 75 160 95.0 50 30 12 C9TS5MD5311AARX
3 x 46.0 415 75 160 14 7.5 50 30 12 C9TS5MD5460AARX
3 x 61.5 415 85 160 18 10.0 50 30 9C9TS5MD5615AARX
3 x 77.0 415 75 230 23 12.5 50 30 12 C9TS5MD5770AARX
3 x 92.2 415 85 230 27 15.0 50 30 9C9TS5MD5920AARX
3 x 108.0 415 75 280 32 17.5 50 30 12 C9TS5MD6108AARX
3 x 123.0 415 75 280 36 20.0 50 30 12 C9TS5MD6123AARX
3 x 154.0 415 85 280 45 25.0 50 30 9C9TS5MD6154AARX
3 x 27.4 440 75 160 95.0 50 30 12 C9TS6MD5274AARX
3 x 41.1 440 75 160 13 7.5 50 30 12 C9TS6MD5411AARX
3 x 54.8 440 85 160 17 10.0 50 30 9C9TS6MD5548AARX
3 x 68.5 440 75 230 21 12.5 50 30 12 C9TS6MD5685AARX
3 x 83.0 440 85 230 26 15.0 50 30 9C9TS6MD5830AARX
3 x 96.0 440 75 280 30 17.5 50 30 12 C9TS6MD5960AARX
3 x 110.0 440 75 280 34 20.0 50 30 12 C9TS6MD6110AARX
3 x 137.0 440 85 280 43 25.0 50 30 9C9TS6MD6137AARX
(*) Maximum admissible RMS current. Ths ≤ 70°C.
Marking
Manufacturer Logo
Safety Warning
Self-healing Dielectric and Approval
Part Number, Batch Number and Production Date
Rated Reactive Power and Current
Rated Voltage and Insulating Level
Rated Frequency and Internal Connections
Climatic Class
5© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3051_C9T_RADIAL 3/29/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Aluminum Can Power Film Capacitors
C9T, 415 – 440 VAC, 3–Phase PFC
Environmental Compliance
As a leading global supplier of electronic components and an environmentally conscious company, KEMET continually
aspires to improve the environmental effects of our manufacturing processes and our nished electronic components.
In Europe (RoHS Directive) and in some other geographical areas such as China (China RoHS), legislation has been enacted
to prevent or otherwise limit the use of certain hazardous materials, including lead (Pb), in electronic equipment. KEMET
monitors legislation globally to ensure compliance and endeavors to adjust our manufacturing processes and/or electronic
components as may be required by applicable law.
For military, medical, automotive, and some commercial applications, the use of lead (Pb) in the termination is necessary
and/or required by design. KEMET is committed to communicating RoHS compliance to our customers. Information related
to RoHS compliance will be provided in data sheets and using specic identiers on the packaging labels.
All KEMET power lm capacitors are RoHS compliant.
Materials & Environment
The selection of raw materials that KEMET uses for the production of its electronic components is the result of extensive
experience. KEMET directs specic attention toward environmental protection. KEMET selects its suppliers according to
ISO 9001 standards and performs statistical analyses on raw materials before acceptance for use in manufacturing our
electronic components. All materials are, to the best of KEMET’s knowledge, non-toxic and free from cadmium; mercury;
chrome and compounds; polychlorine triphenyl (PCB); bromide and chlorinedioxins bromurate clorurate; CFC and HCFC;
and asbestos.
Dissipation Factor
Dissipation factor is a complex function involved with capacitor ineciency. The tgδ may vary up and down with increased
temperature. For more information, refer to Performance Characteristics.
Sealing
Hermetically Sealed Capacitors
As the temperature increases, the pressure inside the capacitor increases. If the internal pressure is high enough, it can
cause a breach in the capacitor. Such a breach can result in leakage, impregnation, lling uid, or moisture susceptibility.
Barometric Pressure
The altitude at which hermetically sealed capacitors are operated controls the capacitor's voltage rating. As the barometric
pressure decreases, the susceptibility to terminal arc-over increases. Non-hermetic capacitors can be affected by internal
stresses due to pressure changes. These effects can be in the form of capacitance changes, dielectric arc-over, and/or low
insulation resistance. Altitude can also affect heat transfer. Heat that is generated in an operation cannot be dissipated
properly, and high RI2 losses and eventual failure can result.
6© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard F3051_C9T_RADIAL 3/29/2019
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
Aluminum Can Power Film Capacitors
C9T, 415 – 440 VAC, 3–Phase PFC
KEMET Electronics Corporation Sales Offi ces
For a complete list of our global sales o ces, please visit www.kemet.com/sales.
Disclaimer
All product speci cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET speci cally disclaims – any warranty concerning suitability for a speci c customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes
no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury
or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
KEMET is a registered trademark of KEMET Electronics Corporation.