Relays with forcibly guided contacts Product catalogue 2008 ELESTA relays - Swiss High-Tech Injection moulding die Coil fabrication The company Products ELESTA relays GmbH established in the Swiss town of Bad Ragaz is one of the leading producers in the field of safety relays with forcibly guided contacts. A very comprehensive programme of safety relays enables ELESTA relays to offer the right product for just about all application areas. Specializing in relays with forcibly guided contacts, ELESTA relays impresses its customers and the market over and over again with innovation which sets distinct benchmarks in the world of safety relays. Relays made by ELESTA are used in safety applications all over the world. The application areas are highly diverse and range from e.g. emergency-off switching devices over transport systems (lifts, escalators, etc.) right to complex machine controls. The focus is on ELESTA relays wherever humans and expensive equipment need to be protected from injuries and damage, respectively. 2 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland ELESTA relays attaches great importance to quality. With a rigid quality programme applied during the entire production process and 100% inspection before delivery we combine "Safety without compromises" and "Quality without compromises". Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 Assembly station Depending on the type of relay, our production sequences are fully or partly automated, whereby highest quality is also guaranteed in the few manual operations. All products are made exclusively at our factory in Bad Ragaz, Switzerland. in performance and safety Set of contacts Set of contacts with actuator Open relay Customer value Safety requirements Our strengths With ELESTA relays, however, the high quality is not only reflected in the products. Our maxim must stand up to highest demands also in the close cooperation with our customers. The majority of our deliveries, for example, are shipped within one week from receipt of the order, and we promise to deal with your technical enquiries within 24 hours. Relays with forcibly guided contacts are used in safety-oriented applications for the decoupling of different voltage potentials. These relays permit implemention of self-monitoring systems. Complying with the European standard EN50205, a relay with forcibly guided contacts consists of at least one N.C. and one N.O. contact. Break and make contact must never be closed at the same time during the entire life of the relay. In case of a fault the contact gap must be at least 0.5 mm. Additionally, the insulation values are subject to higher standards and pollution degree 2 is defined for relays with forcibly guided contacts. For the contact spring assemblies and other conducting parts in the relay it must be ensured that no short circuits or conducting connections result in case such parts should ever fracture or become loose. As an acknowledged specialist in the production of relays with forcibly guided contacts ELESTA relays offers its customers a comprehensive range covering virtually all application cases. Permanent observation of the market, the participation in standardization committees and a close cooperation with suppliers, research institutions and directly with the users enable us to offer our clientele innovative products to suit their requirements in good time. With our outstanding customer support, high flexibility and on time deliveries we provide the services which buyers of such products rightly expect. Our strengths are: An intensive cooperation with our customers is very important to us. Our specialists are ready to support you in the choice of the correct relays for your application, train your personnel in matters of safety relays and make their know-how available to you in complex cases. * Relays for switching currents from 5mA to 16A * 2 to 10 contacts * Minimum coil capacities * Minimum space requirements * Wide coil working ranges * High insulation values * Customized relay variants * RoHS-conforming and safe at higher solder process temperatures * Reliable and rapid support * Short delivery times All statements made in this catalogue are believed to be true and are not legally binding. We reserve the right to make technical alterations. ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 3 Products for every application - page 7-8 SIS 3 Contacts SIS 3 Contacts sensitive SIS 4 Contacts page 9 page 15-16 SGR282Z (2 CO) page 13-14 SIR282 (2 CO) SIR282 (2 CO) sensitive SGR282Z (2 CO) sensitive SIM 2 Contacts page 17 SIS 2 Contacts page 6 - PCB relay with forcibly guided contacts and protective separation between coil/control contact and output contacts (> 10mm). - 2 contacts for 5mA...6A - PCB relay with forcibly guided contacts and protective separation between coil and contacts (leakage and creepage distance > 14mm); protective separation between the contacts facing each other - 2 change-over contacts for 10mA...6A SIR 4 Contacts page 21-23 SIR 4 Contacts Power" SIR 4 Contacts sensitive - PCB relay with forcibly guided contacts and protective separation between coil/control contacts and output contacts (> 10mm) as well as protective separation between the output contacts themselves (> 8mm) - 4 contacts for 10mA...10A 4 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland - PCB relay with forcibly guided - PCB relay with forcibly guided con- contacts and protective separation between coil/control contacts tacts and protective separation and output contacts (> 8mm) and between coil/control contact and output contacts in one row output contacts (> 8mm). (> 5.5mm). - 3 contacts for 5mA...6A - 4 contacts for 5mA...6A - PCB relay with forcibly guided contacts and protective separation between coil and contacts (leakage and creepage distance > 14mm); protective separation between the contacts facing each other - 2 change-over contacts for 10mA...8A - PCB relay with forcibly guided contacts and protective separation between coil and contacts (leakage and creeping distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) - 2 contacts for 10mA...8A SIR 6 Contacts page 24-25 SIR 8 Contacts page 26 - PCB relay with forcibly guided conSIR 6 Contacts sensitive tacts and protective separation - PCB relay with forcibly guided conbetween coil/contacts (> 10mm) tacts and protective separation and contacts in one row (> 8mm) between coil/control contacts and and as left to right contact side (> output contacts (> 10mm) as well 10mm) as protective separation between - 8 contacts for 10mA...10A the output contacts themselves (> 8mm) - 6 contacts for 10mA...10A Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com multifunctional and safety C D 2V4~VAC1 0 422A 25 97 SIF -Nr8. 3009 DC C1 242V50V~A 312 8A 53 SIF r. 3010 E-N ade in land itzer Sw E Made in 44 pe Ty A Sw itze 24 12 33 23 11 rela rla nd 05 64 49 44 63 21 33 54 22 43 53 A2 11 34 34 43 ar lest S us c M m s.co elay w.e ww 0602 12 m .co A1 ys sta A2 le w.e ww A1 us c S Typ eA SIS 6 Contacts page 10 SIF 4 Contacts page 11 SIF 6 Contacts page 12 SIM 3 Contacts - PCB relay with forcibly guided contacts and protective separation between coil and contacts (leakage and creeping distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) - 3 contacts for 10mA...8A page 18 SIM 4 Contacts - PCB relay with forcibly guided contacts and protective separation between coil and contacts (leakage and creeping distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) - 4 contacts for 10mA...8A page 19 SLR 4 Contacts page 20 SIR 10 Contacts page 27 SIP 6 Contacts page 28 - PCB relay with forcibly guided contacts and protective separation between coil/control contacts and output contacts (> 8mm) and output contacts in one row (> 5.5mm). - 6 contacts for 5mA...6A - PCB relay with forcibly guided contacts and protective separation between coil/control contacts and output contacts (> 8mm) and output contacts in one row (> 8mm) and as left to right contact side (> 10mm) - 10 contacts for 10mA...10A - PCB relay with forcibly guided contacts and protective separation between coil/contacts (> 5.5mm) and contacts side by side (> 5.5mm) - 4 contacts for 5mA...8A - PCB relay with forcibly guided contacts and protective separation between coil/control contacts and output contacts (> 8mm) and output contacts in one row (> 8mm). - 2 control contacts for 5mA...6A - 4 output contacts for 10mA...16A ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland - PCB relay with forcibly guided concon tacts and protective separation between coil/contacts (> 5.5mm) and contacts side by side (> 5.5mm) - 6 contacts for 5mA...8A - PCB relay with forcibly guided contacts and protective separation between coil/control contacts and output contacts (> 8mm) as well as protective separation between the output contacts themselves (> 10mm) - 4 contacts for 10mA...10A Accessories pages 29-31 - Plug sockets for print assembly or DIN rail assembly and module Certificate Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 page 32 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 5 SIS 2 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distances > 10mm) - EN 50205, type A - Double and reinforced insulation between the contacts - Contact mounting: SIS112 1NO/1NC - Small external dimensions - Mean coil power 0.27W - Holding power 0.08 W - for Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime Output side 5000 Basic insulation Double or reinforced insulation 1,6 1,6 0,2 1,6 0,4 0,3 0,4 18,7 6 1,6 2,3 10 16,6 11 3,3 3,3 2,2 1 ,3 O1 2,3 3,3 [mm] 4,2 15 7,7 2,3 29,2 Contact material Type of contact AgCuNi+0,2-0,4m Au Single contact with notched crown Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 30A for 20ms Switching voltage range 5 to 250VDC/VAC Switching current range* 5mA to 6A Switching capacity range* 60mW to 1'500W (VA) Contact resistance (as delivered) <100m /28V/100 mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 6 9 12 18 24 48 60 < 3,5 < 4,2 < 6,3 < 8,4 < 12,6 < 16,8 < 33,6 < 42,0 > > > > > > > > 54,9 46,1 30,5 23,0 15,2 11,4 5,7 4,5 91 130 295 520 1`180 2`100 8`350 13`100 10 10 10 10 10 10 13 15 0,5 0,6 0,9 1,2 1,8 2,4 4,8 6,0 Ordering example SIS 1 1 2 24VDC Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time (NO closed) typically 10ms Drop-out time** (NC closed) typically 3ms Bounce time of NO contact typically 2ms Bounce time of NC contact typically 15ms Shock resistance 16ms NO contact 17g NC contact 7g Vibration resistance NO contact 7g 10-200Hz NC contact 2g Test voltage coil/control contact 2'500Veff 1min Test voltage 5'000Veff 1min coil- control contact/output contact Test voltage contact open 1'500Veff 1min Insulation resistance at Up 500V 108 Creepage resistance CTI 175 Weight approx. 18g Mounting position any Ambient temperature -40C to +70C Type of protection RT III Solder bath temperature 270C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 6A circuiting gL/gG (pre-fuse) ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland DC1: 24V AC1: 230V 100 AC15: 230V 50 DC13: 24V 10 0,5 0,1 Load limit curve with direct current 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 3,0 1 2,5 2,0 1,5 1,0 Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 3 4 5 6 78910 Max. switching characteristics (determined acc. to DIN EN 60947-4-1 / EN 60947-5-1): AC 1: 250V/6A AC 15: 230V/3A DC 1: 24V/6A DC 13: 24V/5A/0,1 Hz UL 508: B300 / R300 Insulation terms Coil to control contact: Basic insulation Coil/control contact to output contact: Double or reinforced insulation > 10mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 5 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 2 1 Switching current (A) ** without spark suppression UB UN 2 0,5 0 0 20 40 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 6 No. of operations x 1000 SIS112 500 Current (A) Control side 1000 16,6 2,8 16,5 0,2 29,2 10000 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com SIS 3 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distance > 8mm) - EN 50205, type A - Double and reinforced insulation between the contacts - Contact mounting: SIS212 2NO/1NC - Small external dimensions - Mean coil power 0.6W - Holding power 0.18 W Circuit diagram (view on relay upper side) Contact lifetime 2 Output side Control side 1000 SIS212 0,2 16,5 0,2 Basic insulation Double or reinforced insulation 6,5 12,2 0,4 1 0,2 2,3 6 10 16,6 11 3,3 3,3 2,2 0,3 ,3 O1 2,3 3,3 [mm] 4,2 6,5 8,5 7,7 2,3 29,2 Contact material Type of contact AgCuNi+0.2-0.4m Au Single contact with notched crown Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 30A for 20ms Switching voltage range 5 to 250VDC/VAC Switching current range* 5mA to 6A Switching capacity range* 60mW to 1'500W (VA) Contact resistance (as delivered) < 100m/28V/100mA * Guide values Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % < 3,5 > 0,5 < 6,3 > 0,9 < 8,4 > 1,2 < 12,6 > 1,8 < 16,8 > 2,4 < 33,6 > 4,8 < 42,0 > 6,0 < 77,0 > 11,0 120,0 66,6 50,0 33,3 25,0 12,5 10,0 5,4 41,5 135 240 540 960 3'840 6'000 20'150 10 10 10 10 10 10 13 15 Min. pick-up voltage at 20C Nominal voltage VDC Standard coils for direct current (other voltages on request) 5 9 12 18 24 48 60 110 Mechanical life > 10 x 10 operations Switching frequency, mechanical 15Hz Response time (all NO closed) typically 10ms Drop-out time** (all NC closed) typically 3ms Bounce time of NO contact typically 2ms Bounce time of NC contact typically 15ms Shock resistance 16ms NO contact 17g NC contact 10g Vibration resistance NO contact 7g 10-200Hz NC contact 3g Test voltage coil/control contact 2'500Veff 1min Test voltage 4'000Veff 1min output contacts as against each other Test voltage contact open 1'500Veff 1min Insulation resistance at Up 500V 108 Creepage resistance CTI 175 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT III Solder bath temperature 270C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 6A circuiting gG (pre-fuse) Ordering example AC1: 230V 100 AC15: 230V 50 DC13: 24V 10 2 1 3 4 5 6 7 8910 Switching current (A) Max. switching characteristics (determined acc. to DIN EN 60947-4-1 / EN 60947-5-1): AC 1: 250V/6A AC 15: 230V/3A DC 1: 24V/6A DC 13: 24V/5A/0,1 Hz UL 508: B300 / R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 6A Load limit curve with direct current 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Insulation terms Coil to control contact: Basic insulation Coil/control contact to output contacts: Double or reinforced insulation > 8mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 5 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 0,5 0,1 Excitation voltage range ** without spark suppression SIS 2 1 2 24VDC DC1: 24V 500 6 2,8 0,4 No. of operations x 1000 2 16,6 5000 Current (A) 29,2 25,2 10000 2,5 1 2,0 1,5 1,0 UB UN 2 0,5 0 0 20 40 60 70 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 7 SIS 3 Contacts sensitive Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distance > 8mm) - EN 50205, type A - Double and reinforced insulation between the contacts - Contact mounting: SIS212 2NO/1NC - Small external dimensions - Mean coil power 0.4W - Holding power 0.14 W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 2 16,5 0,2 2 16,6 Output side 5000 Control side 1000 SIS212 Basic insulation Double or reinforced insulation Mechanical life > 10 x 10 operations Switching frequency, mechanical 15Hz Response time (all NO closed) typically 10ms Drop-out time** (all NC closed) typically 3ms Bounce time of NO contact typically 2ms Bounce time of NC contact typically 15ms Shock resistance 16ms NO contact 17g NC contact 10g Vibration resistance NO contact 7g 10-200Hz NC contact 3g Test voltage coil/control contact 2'500Veff 1min Test voltage 4'000Veff 1min output contacts as against each other Test voltage contact open 1'500Veff 1min Insulation resistance at Up 500V 108 Creepage resistance CTI 175 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT III Solder bath temperature 270C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 6A circuiting gG (pre-fuse) DC1: 24V 500 AC1: 230V 100 AC15: 230V 50 DC13: 24V 10 1 0,2 2,3 6 3,3 10 16,6 11 ,3 O1 2,3 3,3 [mm] 4,2 6,5 8,5 7,7 2,3 29,2 Contact material Type of contact AgCuNi+0.2-0.4m Au Single contact with notched crown Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 30A for 20ms Switching voltage range 5 to 250VDC/VAC Switching current range* 5mA to 6A Switching capacity range* 60mW to 1'500W (VA) Contact resistance (as delivered) <100m /28 V/100mA * Guide values Standard coils for direct current (other voltages on request) Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % ** without spark suppression 5 6 9 12 18 24 48 60 < 3,75 < 4,5 < 6,75 < 9,0 < 13,5 < 18,0 < 36,0 < 45,0 > > > > > > > > 80,0 66,6 44,5 33,3 22,2 16,6 8,3 6,6 62,5 90 202 360 810 1'440 5'750 9'000 10 10 10 10 10 10 13 15 0,5 0,6 0,9 1,2 1,8 2,4 4,8 6,0 Maximal contact load at AC 1 with 230V: 2 contacts each with 6A Load limit curve with direct current 6 4 3 2 SIS 2 1 2 24VDC SEN sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,5 1 2,0 1,5 2 1,0 UB UN 0,5 0 0 20 40 60 70 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation Ordering example ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland 3 4 5 6 7 8910 Max. switching characteristics (determined acc. to DIN EN 60947-4-1 / EN 60947-5-1): AC 1: 250V/6A AC 15: 230V/3A DC 1: 24V/6A DC 13: 24V/5A/0,1 Hz UL 508: B300 / R300 Insulation terms Coil to control contact: Basic insulation Coil/control contact to output contacts: Double or reinforced insulation > 8mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 5 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 2 1 Switching current (A) Current (A) 0,2 6,5 12,2 2,8 0,4 3,3 2,2 0,3 0,5 0,1 6 0,4 8 No. of operations x 1000 29,2 25,2 10000 No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com SIS 4 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distance > 8mm) - EN 50205, type A - Double and reinforced insulation between the contacts - Contact mounting: SIS312 3NO/1NC SIS222 2NO/2NC - Small external dimensions - Mean coil power 0.5W - Holding power 0.15 W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 10000 5000 16,6 16,5 0,2 SIS222 0,2 2,3 1 Double or reinforced insulation for safety low voltage > 8mm leakage and creeping distance Basic insulation > 4mm leakage and creeping distance 2,8 8,5 12 2,3 10 16,7 11 3,3 0,3 ,3 O1 4 6,5 13 8,5 13,7 2,3 16,6 16,5 0,2 48 0,3 13 18,7 1 11 2 5 7 2,3 10 3,3 2,8 0,4 0,2 SIS312 ,3 O1 [mm] 2,3 4 13 15 8,7 5 2,3 Contact material Type of contact AgCuNi+0,2-0,4m Au Single contact with notched crown Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 30A for 20ms Switching voltage range 5 to 250VDC/VAC Switching current range* 5mA to 6A Switching capacity range* 60mW to 1'500W (VA) Contact resistance (as delivered) <100m/28 V/100mA * Guide values Standard coils for direct current (other voltages on request) Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time (all NO closed) typically 15ms Drop-out time** (all NC closed) typically 5ms Bounce time of NO contact typically 2ms Bounce time of NC contact typically 15ms Shock resistance 16ms NO contact 10g NC contact 10g Vibration resistant NO contact 10g 10-200Hz NC contact 4g Test voltage coil/control contacts*** 2'500Veff 1min Test voltage 4'000Veff 1min output contacts as against each other Test voltage contact open 1'500Veff 1min Insulation resistance at Up 500V 108 Creepage resistance CTI 175 Weight approx. 30g Mounting position any Ambient temperature -40C to +70C Type of protection RT III Solder bath temperature 270C/5s Thermal resistance 45K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 6A circuiting gG (pre-fuse) AC15: 230V 50 DC13: 24V 10 0,5 2 1 3 4 5 6 7 8910 Switching current (A) Max. switching characteristics (determined acc. to DIN EN 60947-4-1 / EN 60947-5-1): AC 1: 250V/6A AC 15: 230V/3A DC 1: 24V/6A DC 13: 24V/5A/0.1 Hz UL 508: B300 / R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 6A / 3 contacts each with 4A Load limit curve with direct current 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 3,0 2,5 1 2,0 1,5 1,0 UB UN 2 0,5 0 0 20 40 Ambient temperature C Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage Nominal current in mA Resistance in Ohm at 20 C Tolerance in % ** without spark suppression *** SIS222 4000Veff 1min Insulation terms Coil/control contacts: Basic insulation SIS312 Double or reinforced insulation > 8mm SIS222 Coil/control contacts to output contacts: Double or reinforced insulation > 8mm 5 9 12 18 24 48 60 110 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 > 0,5 > 0,9 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 100 56,2 42,1 28,1 20,8 10,4 8,3 4,5 50 160 285 640 1'150 4'600 7'200 24'200 10 10 10 10 10 13 13 15 Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 5 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland AC1: 230V 100 0,1 Double or reinforced insulation for mains circuits > 8mm leakage distance, > 5,5mm creeping distance SIS222 2 6,5 SIS312 DC1: 24V 500 Current (A) 48 0,4 No. of operations x 1000 1000 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Ordering example S I S 3 1 2 24VDC Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 9 SIS 6 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between control and load circuit (leakage and creepage distance > 8mm) - EN 50205, type A - Double and reinforced insulation between the contacts - Contact mounting: SIS422 4NO/2NC - Small external dimensions - Mean coil power 0.66W - Holding power 0.20W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime Double or reinforced insulation for mains circuits > 8mm leakage distance, > 5,5mm creeping distance 0,2 16,5 0,2 2,8 8,5 11 2 6,5 6,5 10,2 5 7 1 2,3 10 3,3 0,3 ,3 O1 2,3 [mm] 4 6,5 6,5 6,5 8,5 8,7 5 2,3 Contact material Type of contact AgCuNi+0.2-0.4m Au Single contact with notched crown Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 30A for 20ms Switching voltage range 5 to 250VDC/VAC Switching current range* 5mA to 6A Switching capacity range* 60mW to 1'500W (VA) Contact resistance (as delivered) < 100m / 28 V / 100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 9 12 18 24 48 60 110 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 > 0,5 > 0,9 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 133 73,7 55,8 37,1 29,7 13,9 11,1 6,0 37,5 122 215 485 860 3'450 5'400 18'300 10 10 10 10 10 10 13 15 Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time (all NO closed) typically 15ms Drop-out time** (all NC closed) typically 5ms Bounce time of NO contact typically 2ms Bounce time of NC contact typically 15ms Shock resistance 16ms NO contact 10g NC contact 9g Vibration resistant NO contact 10g 10-200Hz NC contact 3g Test voltage coil/control contacts 2'500Veff 1min Test voltage 4'000Veff 1min output contacts as against each other Test voltage contact open 1'500Veff 1min Insulation resistance at Up 500V 108 Creepage resistance CTI 175 Weight approx. 35g Mounting position any Ambient temperature -40C to +70C Type of protection RT III Solder bath temperature 270C/5s Thermal resistance 45K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 6A circuiting gG (pre-fuse) ** without spark suppression Insulation terms Coil/control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 8mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 5 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Ordering example No. of operations x 1000 AC1: 230V 100 AC15: 230V 50 DC13: 24V 10 0,5 0,1 2 1 3 4 5 6 7 8910 Switching current (A) Max. switching characteristics (determined acc. to DIN EN 60947-4-1 / EN 60947-5-1): AC 1: 250V/6A AC 15: 230V/3A DC 1: 24V/6A DC 13: 24V/5A/0.1 Hz UL 508: B300 / R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 6A 3 contacts each with 4A 4 contacts each with 3A Load limit curve with direct current 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,5 1 2,0 1,5 1,0 UB UN 2 0,5 0 0 20 40 60 70 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation S I S 4 2 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 10 DC1: 24V 500 Current (A) Basic insulation > 4mm leakage and creeping distance SIS422 0,4 5000 1000 Double or reinforced insulation for safety low voltage > 8mm leakage and creeping distance 16,6 48 10000 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com C D C1 242V50V~A 312 8A 53 SIF r. 3010 E-N ade in SIF 4 Contacts land itzer Sw w S 0602 us 34 pe Ty A 23 11 Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (> 5.5 mm) and contacts side by side (> 5.5 mm) - EN 50205 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact mounting: SIF312 3AK/1RK - Compact height: only 10.9mm - Mean coil power 0.70W - Holding power 0.21 W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 7,5 7,5 7,5 34 23 1,2 1 4,2 1,6 10,5 6,4 15,8 18,2 * * [mm] 5,1 28,3 3,1 4,8 21 23,2 3 1, 3,1 * O 4,2 * 7,6 *Do not drill when SMD arrangement. Contact material Type of contact AgCuNi + 0.2 m Au Single contact with notched crown Rated switching capacity 250VAC 8A AC1 2`000VA Electr. life AC1 (360 S/h) approx.100`000 Inrush current max 30A for 20ms Switching voltage range 5 to 250VDC/VAC Switching current range* 5mA to 8A Switching capacity range* 60mW to 2`000W (VA) Contact resistance (as delivered) < 100m/28 V/100mA * Guide values Resistance in Ohm at 20 C Tolerance in % < 3.5 > 0.5 < 8.4 > 1.2 < 12.6 > 1.8 < 14.0 > 2.0 < 16.8 > 2.4 < 33.6 > 4.8 < 42.0 > 6.0 < 77,0 > 11,0 Nominal current in mA Drop-out voltage at 20 C VDC Min. pick-up voltage at 20C VDC Nominal voltage VDC Standard coils for direct current (other voltages on request) 5 12 18 20 24 48 60 110 No. of operations x 1000 33 24 11 12 A1 A2 140.0 58.5 39.1 35.0 29.2 14.6 11.7 6,3 35.7 205 460 570 820 3`280 5`100 17`250 10 10 10 10 10 10 13 13 Ordering example 1000 SIF-312 100 10 0.1 0.5 1 3 4 5 6 7 8 910 2 Switching current (A) Double or reinforced insulation Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 12ms Drop-out time** typically 5ms Bounce time of NO contact typically 3ms Bounce time of NC contact typically 12ms Shock resistance NO contact 15g NC contact 6g Vibration resistance NO contact 10g 10-200Hz NC contact 2g Test voltage coil to contacts 4`000Veff 1min Test voltage 4'000Veff 1min contacts against each other Test voltage contact open 1'500Veff 1min Insulation resistance at Up 500V 108 Creepage resistance CTI 175 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270C/5s Thermal resistance 60K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to 1`000A SCPD 10A short circuiting gL/gG (pre-fuse) Max. switching characteristics (DIN EN 60947-4-1/ EN 60947-5-1): AC 1: 250V/8A AC 15: 230V/6A DC 1: 24V/8A DC 13: 24V/5A/0.1Hz UL508: B300/R300 Maximal contact load at AC 1with 230V: 2 contacts each with 8A 3 contacts each with 6A Load limit curve with direct current (Resistive load) 500 300 300 W 250 W 200 200 W 150 W 100 Voltage (VDC) 2,9 15,4 44 3,1 4,2 4,2 0,3 1,5 10000 3,1 23,2 3,1 2,2 10,9 5,1 1,6 A2 A1 43 29,4 37,8 12 33 General data 1,5 7,6 24 43 Relay data 41 44 c M com s. elay star .ele ww 100 W 70 80 W 50 60 W 40 W 30 20 20 W 10 10 W 0.1 0.2 0.3 0.5 0.7 1.0 2 3 4 5 6 7 8 10 Current (A) ** without spark suppression Insulation terms Double or reinforced insulation >5.5mm between all current circuits Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 6 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Excitation voltage range 2.5 2.0 UB UN 1.5 1 1.0 2 0.5 0 0 20 40 60 70 80 10 0 Ambient temperature C SIF 3 1 2 24VDC 1) Max. excitation voltage with contact load < 6A 2) Min. excitation voltage (guaranteed values) without previous operation Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 11 C D 2V4~VAC1 0 2 5 42 A 2 97 SIF r8. 3009 S E-Nde in SIF 6 Contacts om A1 e Typ Contact lifetime 15,8 15,8 15,8 3,3 * 7,5 7,5 4,1 3,1 * 3 15,4 1, O * [mm] 3,1 1,5 * *Do not drill when SMD arrangement. Contact material Type of contact AgCuNi + 0.2 m Au Single contact with notched crown Rated switching capacity 250VAC 8A AC1 2`000VA Electr. life AC1 (360 S/h) approx.100`000 Inrush current max. 30A for 20ms Switching voltage range 5 to 250VDC/VAC Switching current range* 5mA to 8A Switching capacity range* 60mW to 2`000W (VA) Contact resistance (as delivered))< 100m / 28 V / 100mA * Guide values Resistance in Ohm at 20 C Tolerance in % < 3.5 > 0.5 < 8.4 > 1.2 < 12,6 > 1,8 < 14.0 > 2.0 < 16.8 > 2.4 < 33.6 > 4.8 < 42.0 > 6.0 < 77.0 > 11.0 33 43 11 21 44 22 A2 A1 SIF-422 1000 100 10 0.1 133.3 55.8 38,9 33.3 27.5 13.8 11.1 6.0 37.5 215 462 600 870 3`460 5`400 18`300 10 10 10 10 10 10 13 15 Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 20ms Drop-out time** typically 8ms Bounce time of NO contact typically 3ms Bounce time of NC contact typically 12ms Shock resistance NO contact 10g NC contact 6g Vibration resistance NO contact 10g 10-200Hz NC contact 2g Test voltage coil to contacts 4`000Veff 1min Test voltage contacts against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance at Up 500V 108 Creepage resistance CTI 175 Weight approx. 35g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270C/5s Thermal resistance 47K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to 1`000A SCPD 10A short circuiting gL/gG (pre-fuse) 1 3 4 5 6 7 8 910 2 Insulation terms Double or reinforced insulation >5.5mm between all current circuits Max. switching characteristics (DIN EN 60947-4-1/ EN 60947-5-1): AC 1: 250V/8A AC 15: 230V/6A DC 1: 24V/8A DC 13: 24V/5A/0.1Hz UL508: B300/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 8A 3 contacts each with 6A 4 contacts each with 4.5A Load limit curve with direct current (Resistive load) 500 300 300 W 250 W 200 200 W 150 W 100 100 W 70 80 W 50 60 W 40 W 30 20 20 W 10 10 W 0.1 2 3 4 5 6 7 8 10 Excitation voltage range 2.5 Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 6 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 2.0 1 1.5 1.0 UB 2 0.5 0 0 20 40 60 70 80 10 0 Ambient temperature C 1) Max. excitation voltage with contact load < 6A 2) Min. excitation voltage (guaranteed values) without previous operation SIF 4 2 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 0.2 0.3 0.5 0.7 1.0 Current (A) UN ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland 0.5 Switching current (A) Ordering example 12 No. of operations x 1000 63 ** without spark suppression Nominal current in mA Drop-out voltage at 20 C VDC Min. pick-up voltage at 20C VDC Nominal voltage VDC Standard coils for direct current (other voltages on request) 5 12 18 20 24 48 60 110 12 53 Voltage (VDC) 2,9 1,6 4,1 3,1 34 64 Double or reinforced insulation 0,3 0,4 A 10000 54 1,5 1,2 2,2 10,9 0,5 1 A2 21 11 S Circuit diagram (view on relay upper side) 30,4 22 43 33 ys.c - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (> 5.5 mm) and contacts side by side (> 5.5 mm) - EN 50205 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact mounting: SIF422 4NO/2NC - Compact height: only 10.9mm - Mean coil power 0.66W - Holding power 0.20 W - For Railway Applications EN50155 33,5 44 63 53 rela Diagrams 1,6 64 49 sta le w.e ww General data 3,1 05 d 34 Relay data 47,4 an 12 c 53,6 zerl 54 Ma us 3,1 wit No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com SGR282Z Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation diagonally between left and right contact side (leakage and creeping distances > 5.5mm) - EN 50205, type B - 2 CO contacts - Mean coil power 1 W - Holding power 0.31 W Circuit diagram (view on relay upper side) Contact lifetime for AgCuNi 1000 SGR282Z 1 2,6 5 5 15 2,6 O 7,5 1,3 [mm] 2,5 / 2,54 Contact material AgCuNi Type of contact Single contact Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 15A for 20ms Switching voltage range 50 to 250 VDC/VAC Switching current range* 20mA to 6A Switching current range** 10mA to 6A Switching capacity range* 0.12VA(W) to 1'500VA Switching capacity range** 0.06VA(W) to 1'500VA Contact resistance (as delivered)< 100m / 28 V / 100mA * Guide values ** Values for AgCuNi + 4-6 m Au Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 5 6 12 18 24 48 60 110 3,75 4,5 9,0 13,5 18,0 36,0 45,0 82,5 > 0,5 > 0,6 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 181,8 166,6 85,7 66,6 33,3 20,8 13,6 11,0 27,5 36 140 270 720 2'300 4'400 10'000 10 10 10 10 10 10 13 15 SGR282Z 24VDC AU6 08 Type designation Coil voltage Gold plating 4 - 6m Au Wash-resistant / with O-ring Insulation terms Coil/contacts: Double or reinforced insulation > 14mm Left to right contact side: Double or reinforced insulation > 5.5mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 1 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V1 DC 1: 24V AC 1: 230V 100 AC 15: 230V DC 13: 24V 10 0.5 0.1 10 Maximal contact load at AC 1 with 230V: 2 contacts each with 6A Gold contacts with 4-6m layer thickness When high voltages and currents are switched, the layer of gold is destroyed already after a few switching operations. Once the gold layer is damaged due to the switching of high loads, such a contact must not be used any more for signal and control current circuits. Safe contact making is then only possible at high loads with the formation of sparks. Load limit curve with direct current 8 6 4 3 1 2 2 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 1 1,5 1,0 Options, accessories Contact material SGR282Z..VDC AgCuNi +4 - 6m Au PCB socket, DIN rail socket see page 29 Wash-resistant with O-Ring Sealed RT III on request 5.0 1.0 Switching current (A) Max. switching characteristics (acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/3A, DC13: 24V/4A UL 508: C300 *** without spark suppression Standard coils for direct current (other voltages on request) Ordering example Mechanical life > 50 x 106 operations Switching frequency, mechanical 20Hz Response time typically 12ms Drop-out time*** typically 5ms Bounce time of NO contact typically 4ms Bounce time of NC contact typically 8ms Vibration resistance 10-55Hz, AK 10g, RK 1.5g Test voltage coil/contacts 5'000Veff 1min Test voltage contact set/contact set 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 550 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT II / RT III optionally Solder bath temperature 270C/5s Thermal resistance 50K/W Temperature limit for coil 120C Pollution degree 2 Resistance to 1`000A SCPD 6A short circuiting gL/gG (pre-fuse) Current (A) 3,7 0,3 25,6 Double or reinforced insulation No. of operations x 1000 Control side Output side 12,7 30,2 10 000 UB UN 2 0,5 0 0 20 40 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 13 SGR282Z sensitive Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation diagonally between left and right contact side (leakage and creeping distances > 5.5mm) - EN 50205, type B - 2 CO contacts - Mean coil power 0.7 W - Holding power 0.21 W Circuit diagram (view on relay upper side) Contact lifetime for AgCuNi 1000 SGR282Z 1 2,6 5 5 15 2,6 O 7,5 1,3 [mm] 2,5 / 2,54 Contact material AgCuNi Type of contact Single contact Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 15A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 20mA to 6A Switching current range** 10mA to 6A Switching capacity range* 0.12VA(W) to 1'500VA Switching capacity range** 0.06VA(W) to 1'500VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values ** Values for AgCuNi + 4-6 m Au Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 5 6 12 18 24 48 60 110 3,75 4,5 9,0 13,5 18,0 36,0 45,0 82,5 > 0,5 > 0,6 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 144,0 120,0 60,0 40,0 30,0 15,0 12,0 6,5 34,7 50 200 450 800 3'200 5'000 16'800 10 10 10 10 10 10 13 15 SGR282Z 24VDC SEN AU6 08 Type designation Coil voltage sensitive coil Gold plating 4 - 6m Au Wash-resistant / with O-ring 14 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Insulation terms Coil/contacts: Double or reinforced insulation > 14mm Left to right contact side: Double or reinforced insulation > 5.5mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 1 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V1 DC 1: 24V AC 1: 230V 100 AC 15: 230V DC 13: 24V 10 0.5 0.1 5.0 1.0 10 Switching current (A) Max. switching characteristics (acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/3A, DC13: 24V/4A UL508: C300 Maximal contact load at AC 1 with 230V: 2 contacts each with 6A Gold contacts with 4-6m layer thickness When high voltages and currents are switched, the layer of gold is destroyed already after a few switching operations. Once the gold layer is damaged due to the switching of high loads, such a contact must not be used any more for signal and control current circuits. Safe contact making is then only possible at high loads with the formation of sparks. Load limit curve with direct current 8 6 4 3 1 2 *** without spark suppression Standard coils for direct current (other voltages on request) Ordering example Mechanical life > 50 x 106 operations Switching frequency, mechanical 20Hz Response time typically 12ms Drop-out time*** typically 5ms Bounce time of NO contact typically 4ms Bounce time of NC contact typically 8ms Vibration resistance 10-55Hz, AK 10g, RK 1.5g Test voltage coil/contacts 5'000Veff 1min Test voltage contact set/contact set 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 550 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT II / RT III optionally Solder bath temperature 270C/5s Thermal resistance 50K/W Temperature limit for coil 120C Pollution degree 2 Resistance to 1`000A SCPD 6A short circuiting gL/gG (pre-fuse) Current (A) 3,7 0,3 25,6 Double or reinforced insulation No. of operations x 1000 Control side Output side 12,7 30,2 10 000 2 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 1 1,5 1,0 Options, accessories Contact material SGR282Z..VDC S AgCuNi +4 - 6m Au PCB socket, DIN rail socket see page 29 Wash-resistant with O-Ring Sealed RT III on request UB UN 2 0,5 0 0 20 40 60 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com SIR282 Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation diagonally between left and right contact side (leakage and creeping distances > 5.5mm) - EN 50205, type B - 2 CO contacts - Mean coil power 1W - Holding power 0.31 W Circuit diagram (view on relay upper side) Contact lifetime for NO contact 7,5 1,3 [mm] 2,5 / 2,54 Contact material AgSnO2+0.2m Au Type of contact Single contact Rated switching capacity 250VAC 8A AC1 2'000VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 15A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 8A Switching capacity range* 0.12VA(W) to 2'000VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Standard coils for direct current (other voltages on request) Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 5 6 12 18 24 48 60 110 3,75 4,5 9,0 13,5 18,0 36,0 45,0 82,5 > 0,5 > 0,6 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 181,0 166,0 85,7 66,6 33,3 20,8 13,6 11,0 27,5 36 140 270 720 2'300 4'400 10'000 10 10 10 10 10 10 13 15 Ordering example 24VDC 08 Type designation Coil voltage Wash-resistant / with O-ring No. of operations x 1000 Control side Output side Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 1 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V1 DC 1: 24V AC 1: 400V 100 DC 13: 24V 10 0.1 0.5 1.0 10 5.0 Switching current (A) Contact lifetime for NC contact 10 000 1000 AC 15: 230V 100 DC 1: 24V AC 1: 230V DC 13: 24V 10 0.1 0.5 1.0 10 5.0 Switching current (A) Max. switching characteristics (acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/2A, DC13: 24V/3A Load limit curve with direct current 8 6 4 3 ** without spark suppression Insulation terms Coil/contacts: Double or reinforced insulation > 14mm Left to right contact side: Double or reinforced insulation > 5.5mm AC 15: 230V Max. switching characteristics (acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A, DC13: 24V/6A; UL 508: C300 Maximal contact load at AC 1 with 230V: 2 contacts each with 8A 2 1 2 Current (A) 2,6 Mechanical life > 50 x 106 operations Switching frequency, mechanical 20Hz Response time typically 12ms Drop-out time** typically 5ms Bounce time of NO contact typically 4ms Bounce time of NC contact typically 8ms Vibration resistance 10-55Hz, AK 10g, RK 1.5g Test voltage coil/contacts 5'000Veff 1min Test voltage contact set/contact set 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 550 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT II / RT III optionally Solder bath temperature 270C/5s Thermal resistance 50K/W Temperature limit for coil 120C Pollution degree 2 Resistance to 1`000A SCPD 10A short circuiting gL/gG (pre-fuse) No. of operations x 1000 0,3 25,6 3,7 15 O SIR282 SIR282 Double or reinforced insulation 1 5 5 AC 1: 230V 1000 12,7 30,2 2,6 10 000 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 1 1,5 Options, accessories Wash-resistant with O-Ring Sealed RT III PCB socket, DIN rail socket 2 1,0 on request see page 29 UB UN 0,5 0 0 20 40 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 15 SIR282 sensitive Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation diagonally between left and right contact side (leakage and creeping distances > 5.5mm) - EN 50205, type B - 2 CO contacts - Mean coil power 0.7W - Holding power 0.21 W Circuit diagram (view on relay upper side) Contact lifetime for NO contact 7,5 1,3 [mm] 2,5 / 2,54 Contact material AgSnO2+0.2m Au Type of contact Single contact Rated switching capacity 250VAC 8A AC1 2'000VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 15A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 8A Switching capacity range* 0.12VA(W) to 2'000VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 5 6 12 18 24 48 60 110 3,75 4,5 9,0 13,5 18,0 36,0 45,0 82,5 > 0,5 > 0,6 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 144,0 120,0 60,0 40,0 30,0 15,0 12,0 6,5 34,7 50 200 450 800 3'200 5'000 16'800 10 10 10 10 10 10 13 15 Ordering example 24VDC SEN 08 No. of operations x 1000 Control side Output side Insulation terms Coil/contacts: Double or reinforced insulation > 14mm Left to right contact side: Double or reinforced insulation > 5.5mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 1 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V1 DC 1: 24V AC 1: 400V 100 DC 13: 24V 10 0.1 0.5 1.0 10 000 1000 AC 15: 230V 100 DC 1: 24V AC 1: 230V DC 13: 24V 10 0.1 0.5 1.0 Max. switching characteristics (acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/2A, DC13: 24V/3A Load limit curve with direct current 8 6 4 3 2 1 2 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 1 Options, accessories Wash-resistant with O-Ring Sealed RT III PCB socket, DIN rail socket on request see page 29 1,0 UB UN 2 0,5 0 0 20 40 60 80 100 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland 10 5.0 Switching current (A) 1,5 Type designation Coil voltage sensitive coil Wash-resistant / with O-ring 16 10 5.0 Switching current (A) Contact lifetime for NC contact ** without spark suppression Standard coils for direct current (other voltages on request) AC 15: 230V Max. switching characteristics (acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A, DC13: 24V/6A; UL 508: C300 Maximal contact load at AC 1 with 230V: 2 contacts each with 8A Current (A) 2,6 Mechanical life > 50 x 106 operations Switching frequency, mechanical 20Hz Response time typically 12ms Drop-out time** typically 5ms Bounce time of NO contact typically 4ms Bounce time of NC contact typically 8ms Vibration resistance 10-55Hz, AK 10g, RK 1.5g Test voltage coil/contacts 5'000Veff 1min Test voltage contact set/contact set 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 550 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT II / RT III optionally Solder bath temperature 270C/5s Thermal resistance 50K/W Temperature limit for coil 120C Pollution degree 2 Resistance to 1`000A SCPD 10A short circuiting gL/gG (pre-fuse) No. of operations x 1000 0,3 25,6 3,7 15 O SIR282 SIR282 Double or reinforced insulation 1 5 5 AC 1: 230V 1000 12,7 30,2 2,6 10 000 Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com SIM 2 Contacts General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) - EN 50205, type A - Contact mounting: SIM112 1NO/1NC - Small external dimensions - Mean coil power 0.5W - Holding power 0.15 W Circuit diagram (view on relay upper side) Contact lifetime for NO contact 5 2,8 3,7 0,5 2,5 7,5 1 2,5 [mm] 5 No. of operations x 1000 AC 1: 230V DC 1: 24V 100 AC 15: 230V DC 13: 24V 10 0.1 0.5 1.0 10 5.0 Switching current (A) O 1,3 15,9 SIM112 1000 3,7 Contact material AgSnO2+0.2m Au Type of contact Crest contact Rated switching capacity 250VAC 8A AC1 2'000VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 20A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 8A Switching capacity range* 0.06VA(W) to 2'000VA Contact resistance (as delivered) <100m/28V/100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 6 12 21 24 48 60 110 3,5 4,2 8,4 14,7 16,8 33,6 42,0 77,0 > 0,5 > 0,6 > 1,2 > 2,1 > 2,4 > 4,8 > 6,0 > 11,0 111,0 85,7 44,4 23,8 21,8 10,9 8,7 5,5 45 70 270 880 1'100 4'400 6'850 20'000 10 10 10 10 10 13 15 15 Ordering example SIM 1 1 2 24VDC Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 10ms Drop-out time** typically 3ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g Vibration resistance 10-200Hz NO contact > 10g Test voltage coil/contacts 5'000Veff 1min Test voltage left to right contact sides 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 20g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/3A DC 13: 24V/4A DC 13: 24V/6A/0,1Hz UL 508: C150/R300 Load limit curve with direct current 8 6 4 3 2 2 1 Current (A) 2,9 0,3 0,4 15,9 2,5 7,5 2,5 2,8 10 000 Double or reinforced insulation 12,5 26,2 27,4 Control side Output side Relay data 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 60 80 250 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 3,0 1 2,5 2,0 ** without spark suppression 1,5 Insulation terms Coil/contacts: Double or reinforced insulation > 14mm Left to right contact side: Double or reinforced insulation > 5.5mm 1,0 UB 0,5 UN 0 2 0 20 40 100 Ambient temperature C Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 17 SIM 3 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) - EN 50205, type A - Contact mounting: SIM212 2NO/1NC - Small external dimensions - Mean coil power 0.75W - Holding power 0.21 W Circuit diagram (view on relay upper side) Contact lifetime for NO contact 26,2 2,9 0,3 0,4 5 5 5 15,9 2,5 7,5 2,5 2,8 O 2,8 0,5 2,5 1,3 1 2,5 7,5 [mm] Variante 1 Standard 15,9 5 5 5 2,5 7,5 2,5 2,8 2,4 2,4 O 1,3 Variante 2 KV2 15,9 5 5 5 2,4 Contact material AgSnO2+0.2m Au Type of contact Crest contact Rated switching capacity 250VAC 8A AC1 2'000VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 20A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 8A Switching capacity range* 0.06VA(W) to 2'000VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Standard coils for direct current (other voltages on request) Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 3,75 4,5 9,0 15,75 18,0 36,0 45,0 82,5 > 0,5 > 0,6 > 1,2 > 2,1 > 2,4 > 4,8 > 6,0 > 11,0 151,0 125,0 63,1 35,5 30,0 15,4 12,5 6,8 33 48 190 590 800 3'100 4'800 16'000 10 10 10 10 10 10 13 15 Ordering example SIM 2 1 2 24VDC 2 KV2 Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Variante 1 Variante 2 Standard KV2 Basic insulation Double or reinforced insulation Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 10ms Drop-out time** typically 4ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g Vibration resistance 10-200Hz NO contact > 10g Test voltage coil/contacts 5'000Veff 1min Test voltage left to right contact sides 4'000Veff 1min Test voltage contacts as one after the other 2'500Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 25g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 50K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) No. of operations x 1000 Control side Output side SIM212 AC 1: 230V DC 1: 24V 100 AC 15: 230V DC 13: 24V 10 0.1 0.5 1.0 10 5.0 Switching current (A) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/3A DC 13: 24V/4A DC 13: 24V/6A/0,1Hz UL 508: C150/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 8A Load limit curve with direct current 8 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 60 80 250 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 ** without spark suppression 5 6 12 21 24 48 60 110 18 SIM212 1000 Current (A) 12,5 36,1 10 000 1 Insulation terms Coil/contacts: Double or reinforced insulation > 14mm Left to right contact side: Double or reinforced insulation > 5.5mm Contacts in one row: Basic insulation 1,5 1,0 UB UN 2 0,5 0 0 20 40 100 Ambient temperature C Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Options, accessories PCB socket, DIN rail socket Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 see page 30 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. SIM 4 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) - EN 50205, type A - Contact mounting: SIM312 3NO/1NC SIM222 2NO/2NC - Small external dimensions - Mean coil power 1W - Holding power 0.29W Circuit diagram (view on relay upper side) Contact lifetime for NO contact 2,9 0,3 0,4 5 5 5 15,9 2,5 7,5 2,5 2,8 2,8 2,4 O 0,5 2,5 1 2,5 7,5 1,3 [mm] 15,9 5 5 5 2,4 Contact material AgSnO2+0,2m Au Type of contact Crest contact Rated switching capacity 250VAC 8A AC1 2'000VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 20A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 8A Switching capacity range* 0,06VA(W) to 2'000VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Standard coils for direct current (other voltages on request) SIM222 Basic insulation Double or reinforced insulation No. of operations x 1000 Output side Control side SIM312 1000 Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 3,75 4,5 9,0 15,75 18,0 36,0 45,0 82,5 > 0,5 > 0,6 > 1,2 > 2,1 > 2,4 > 4,8 > 6,0 > 11,0 181,8 166,0 85,7 46,6 40,0 20,8 16,6 9,6 27,5 36 140 450 600 2'300 3'600 12'000 10 10 10 10 10 10 13 15 Ordering example Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 8ms Drop-out time** typically 4ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g Vibration resistance 10-200Hz NO contact > 10g Test voltage coil/contacts 5'000Veff 1min Test voltage left to right contact sides 4'000Veff 1min Test voltage contacts as one after the other 2'500Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 25g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 50K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) 100 AC 15: 230V DC 13: 24V 10 0.5 1.0 10 5.0 Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/3A DC 13: 24V/4A DC 13: 24V/6A/0,1Hz UL 508: C150/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 8A 3 contacts each with 6A Load limit curve with direct current 8 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 1 Insulation terms Coil/contacts: Double or reinforced insulation > 14mm Left to right contact side: Double or reinforced insulation > 5.5mm Contacts in one row: Basic insulation Tests, regulations Approvals SEV, UL, cUL, TUV UL File E18895 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 SIM 3 1 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation DC 1: 24V Switching current (A) ** without spark suppression 5 6 12 21 24 48 60 110 AC 1: 230V 0.1 Current (A) 12,5 26,2 36,1 10 000 1,5 1,0 UB UN 2 0,5 0 0 20 40 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Options, accessories PCB socket, DIN rail socket see page 30 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 19 SLR 4 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 8mm) as well as protective separation between the output contacts themselves (> 10mm) - EN 50205, type A - Contact mounting: SLR312 3NO/1NC SLR222 2NO/2NC - Small external dimensions - Mean coil power 0.6W - Holding power 0.18W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 0,3 16,5 2,9 0,4 0,6 20,5 6,4 10,7 6,4 6,4 3 4 1 13,7 11,3 1,4 16,7 3 2,9 2,9 20,5 16,7 5,4 4 12,7 25 O1,3 [mm] 6,4 10,7 6,4 6,4 Contact material AgSnO2+0,2m Au Type of contact Crest contact Rated switching capacity 250VAC 10A AC1 2'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 25A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 10A Switching capacity range* 0.06VA(W) to 2'500VA Contact resistance (as delivered) <100m/28V/100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 6 12 18 24 48 60 110 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 > 0,5 > 0,6 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 121,0 100,0 50,0 33,3 25,2 12,6 10,0 5,5 41 60 240 540 950 3'800 6'000 20'000 10 10 10 10 10 10 13 15 Ordering example SLR 3 1 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 20 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Basic insulation Double or reinforced insulation Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 15ms Drop-out time** typically 4ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 6g Vibration resistance NO contact > 5g 10-200Hz NC contact 1.5g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 30g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) No. of operations x 1000 Control Output side side SLR222 SLR312 AC 1: 230V Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com AC 15: 230V 100 DC 13: 24V 10 0.1 0.5 1.0 5.0 10 Switching current (A) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A DC 13: 24V/7.5A/0.1 Hz UL 508: C600/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 10A 3 contacts each with 8.4A Load limit curve with direct current 10 8 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 1 1,5 ** without spark suppression Insulation terms Coil/control contacts NO: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 8mm Output contacts as against each other: Reinforced insulation > 10mm DC 1: 24V 1000 Current (A) 33,4 53,3 10 000 1,0 UB UN 2 0,5 0 0 20 40 60 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. SIR 4 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 10mm) as well as protective separation between the output contacts themselves (> 8mm) - EN 50205, type A - Contact mounting: SIR312 3NO/1NC SIR222 2NO/2NC - Small external dimensions - Mean coil power 0.6W - Holding power 0.18W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 2,9 0,7 30,7 16 0,4 21 5 10,5 5 3 3 1 10 3 3 1,9 3 10 O 1,9 1,3 [mm] 21 5 10,5 5 3 Contact material AgSnO2+0.2m Au Type of contact Crest contact Rated switching capacity 250VAC 10A AC1 2'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 25A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 10A Switching capacity range* 0.06VA(W) to 2'500VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 6 12 18 24 48 60 110 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 > 0,5 > 0,6 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 121,0 100,0 50,0 33,3 25,2 12,6 10,0 5,5 41 60 240 540 950 3'800 6'000 20'000 10 10 10 10 10 10 13 15 Ordering example SIR 3 1 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation SIR222 Basic insulation Double or reinforced insulation Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 15ms Drop-out time** typically 4ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 6g Vibration resistance NO contact > 5g 10-200Hz NC contact 1,5g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 30g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) No. of operations x 1000 Output side Control side SIR312 AC 1: 230V AC 15: 230V 100 DC 13: 24V 10 0.1 0.5 1.0 10 5.0 Switching current (A) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A DC 13: 24V/7.5A/0.1 Hz UL 508: C600/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 10A 3 contacts each with 8.4A Load limit curve with direct current 10 8 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 2,0 1 ** without spark suppression 1,5 Insulation terms Coil to control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 10mm Output contacts as against each other: Double or reinforced insulation > 8mm 1,0 Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 DC 1: 24V 1000 Current (A) 46,4 10 000 UB UN 2 0,5 0 0 20 40 60 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Options, accessories PCB socket see page 31 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 21 SIR 4 Contacts Power" Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 10mm) and output contacts side by side (> 8mm) - EN 50205, type A - Contact mounting: SIR312P Power" Control contacts1NO/1NC Output contacts 2NO SIR222P Power" Control contacts 2NC Output contacts 2NO - Inrush current 60A / continuous current 12A - Mean coil power 0.75W - Holding power 0.23 W Circuit diagram (view on relay upper side) contacts each with (output contacts) 2,9 0,7 30,7 16 0,4 21 5 10,5 5 3 3 1 10 3 3 1,9 3 10 O 1,9 1,3 [mm] 21 5 10,5 5 3 Control Contacts Contact material AgSnO2+0.2m Au Rated switching capacity 250VAC 6A AC1 1`500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 15A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 5mA to 6A Switching capacity range* 60mW to 1'500W (VA) Contact resistance (as delivered) <100m/28 V/100mA * Guide values Output contacts Contact material Rated switching capacity AgSnO2 250VAC (440VAC) 12A AC1 3`000VA Electr. life AC1 (360 cycles/h) approx. 250`000 Inrush current max. 60A for 20ms Switching voltage range 5 to 480 VDC/VAC Switching current range* 10mA to 12A Switching capacity range* 120mW to 3`000W (VA) Contact resistance (as delivered) <100m/28 V/100mA * Guide values 22 Resistance in Ohm at 20 C Tolerance in % Drop-out voltage at 20 C VDC < 3.5 > 0.5 < 8.4 > 1.2 < 12,6 > 1,8 < 14.0 > 2.0 < 16.8 > 2.4 < 33.6 > 4.8 < 42.0 > 6.0 < 77.0 > 11.0 Nominal current in mA 5 12 18 20 24 48 60 110 Min. pick-up voltage at 20C VDC Nominal voltage VDC Standard coils for direct current (examples) other voltages on request 151.0 63.1 41,6 37.7 31.5 15.7 12.5 6.8 33 190 432 530 760 3`050 4`800 16`000 10 10 10 10 10 10 10 15 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland SIR222P Basic insulation Double or reinforced insulation Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 15ms Drop-out time** typically 4ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact 17g NC contact 7g Vibration resistance NO contact 10g 10-200Hz NC contact 4,5g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 32g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short circuiting 1`000A SCPD 6A control contacts gG (pre-fuse) Resistance to short circuiting 1`000A SCPD 16A output contacts gL/gG (pre-fuse) ** without spark suppression Insulation terms Coil to control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 10mm Output contacts as against each other: Double or reinforced insulation > 8mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Options, accessories PCB socket: Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 see page 31 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com No. of operations x 1000 Output side Control side SIR312P DC 1: 24V 1000 DC 14: 24V DC-13: 24V 100 DC-13: 24V 10 1 5 10 16 Switching current (A) Contact lifetime (output contacts) 10 000 1000 No. of operations x 1000 46,4 10 000 AC 1: 230V AC 1: 400V AC 3: 230V AC15: 230V AC 3: 400V 100 10 10 5 1 16 Switching current (A) Maximal contact load at AC 1 with 230V: 2 contacts each with 12A Excitation voltage range 2,0 UB UN 1,5 1 1,0 2 0,5 0 0 20 40 60 80 100 Ambient temperature C 1) Max. excitation voltage with contact load < 2A control contacts / < 10A output contacts 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Ordering example SIR 3 1 2 P 24VDC Coil voltage Power version Soldering tags Number of NC contacts Number of NO contacts Type designation SIR 4 Contacts sensitive Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 10mm) as well as protective separation between the output contacts themselves (> 8mm) - EN 50205, type A - Contact mounting: SIR312 3NO/1NC SIR222 2NO/2NC - Small external dimensions - Mean coil power 0.36W - Holding power 0.12W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 2,9 0,7 30,7 16 0,4 21 5 10,5 5 3 3 1 10 3 3 1,9 3 10 O 1,3 [mm] 21 1,9 5 10,5 5 3 Contact material AgSnO2+0.2m Au Type of contact Crest contact Rated switching capacity 250VAC 10A AC1 2'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 25A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 10A Switching capacity range* 0.06VA(W) to 2'500VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 6 9 12 18 24 48 60 3,75 4,5 6,75 9,0 13,5 18,0 36,0 45,0 > > > > > > > > 72,0 60,0 40,0 30,0 20,0 15,0 7,5 6,0 69,4 100 225 400 900 1'600 6'400 10'000 10 10 10 10 10 10 13 15 0,5 0,6 0,9 1,2 1,8 2,4 3,6 4,5 Ordering example SIR 3 1 2 24VDC SEN Sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation SIR222 Basic insulation Double or reinforced insulation Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 18ms Drop-out time** typically 5ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 6g Vibration resistance NO contact > 5g 10-200Hz NC contact 1,5g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 30g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) No. of operations x 1000 Output side Control side SIR312 AC 1: 230V DC 1: 24V 1000 AC 15: 230V 100 DC 13: 24V 10 0.1 1.0 10 5.0 Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A DC 13: 24V/7.5A/0.1 Hz UL 508: C600/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 10A 3 contacts each with 8.4A Load limit curve with direct current 10 8 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 3,0 ** without spark suppression 2,5 Insulation terms Coil to control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 10mm Output contacts as against each other: Double or reinforced insulation > 8mm 2,0 1 1,5 2 1,0 UB 0,5 UN 0 0 Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 0.5 Switching current (A) Current (A) 46,4 10 000 20 40 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Options, accessories PCB socket see page 31 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 23 SIR 6 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 10mm) as well as protective separation between the output contacts themselves (> 8mm) - EN 50205, type A - Contact mounting: SIR332 3NO/3NC SIR422 4NO/2NC SIR512 5NO/1NC - Small external dimensions - Mean coil power 0.75W - Holding power 0.22W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 0,7 30,7 2,9 1 0,4 1,9 21 5 10,5 5 7,5 5 3 3 3 10 10 3 O1,3 3 [mm] 1,9 21 5 10,5 5 7,5 5 3 Contact material AgSnO2+0.2m Au Type of contact Crest contact Rated switching capacity 250VAC 10A AC1 2'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 25A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 10A Switching capacity range* 0.06VA(W) to 2'500VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 6 12 18 24 48 60 110 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 > 0,5 > 0,6 > 1,2 > 1,8 > 2,4 > 4,8 > 6,0 > 11,0 151,0 125 63,1 41,6 31,5 15,7 12,5 6,8 33 48 190 432 760 3'050 4'800 16'000 10 10 10 10 10 10 13 15 Ordering example SIR 4 2 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 24 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland SIR512 Basic insulation Double or reinforced insulation 16 58,9 SIR422 AC 1: 230V DC 1: 24V 1000 AC 15: 230V 100 DC 13: 24V 10 0.1 0.5 1.0 10 5.0 Switching current (A) Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 15ms Drop-out time** typically 4ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 6g Vibration resistance NO contact > 5g 10-200Hz NC contact 2g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 35g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A DC 13: 24V/7.5A/0.1 Hz UL 508: C600/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 10A 3 contacts each with 8.4A 4 contacts each with 7.3A 5 contacts each with 6A Load limit curve with direct current 10 8 6 4 3 2 2 1 Current (A) SIR332 No. of operations x 1000 Control side Output side 10 000 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range ** without spark suppression 2,0 Insulation terms Coil to control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 10mm Output contacts as against each other: Double or reinforced insulation > 8mm UB UN 1,5 1 1,0 2 0,5 0 0 20 40 60 Ambient temperature C Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Options, accessories PCB socket Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 see page 31 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. SIR 6 Contacts sensitive Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 10mm) as well as protective separation between the output contacts themselves (> 8mm) - EN 50205, type A - Contact mounting: SIR332 3NO/3NC SIR422 4NO/2NC SIR512 5NO/1NC - Small external dimensions - Mean coil power 0.50W - Holding power 0.18W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 0,7 30,7 2,9 1 0,4 1,9 21 10,5 5 7,5 5 5 3 3 3 10 10 3 O1,3 3 [mm] 21 1,9 10,5 5 5 7,5 5 3 Contact material AgSnO2+0.2m Au Type of contact Crest contact Rated switching capacity 250VAC 10A AC1 2'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 25A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 10A Switching capacity range* 0.06VA(W) to 2'500VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Nominal voltage VDC Min. pick-up voltage at 20C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % Standard coils for direct current (other voltages on request) 5 6 9 12 18 24 48 60 3,75 4,5 6,75 9,0 13,5 18,0 36,0 45,0 > > > > > > > > 100,0 83,3 56,2 41,6 27,7 20,8 10,4 8,3 50 72 160 288 648 1'150 4'600 7'200 10 10 10 10 10 10 13 15 0,5 0,6 0,9 1,2 1,8 2,4 3,6 4,5 Ordering example SIR 4 2 2 24VDC SEN SIR512 Basic insulation Double or reinforced insulation 16 58,9 SIR422 Sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation AC 1: 230V DC 1: 24V 1000 AC 15: 230V 100 DC 13: 24V 10 0.1 0.5 1.0 10 5.0 Switching current (A) Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 18ms Drop-out time** typically 5ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 6g Vibration resistance NO contact > 5g 10-200Hz NC contact 2g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 35g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 55K/W Temperature limit for coil 120C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A DC 13: 24V/7.5A/0.1 Hz UL 508: C600/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 10A 3 contacts each with 8.4A 4 contacts each with 7.3A 5 contacts each with 6A Load limit curve with direct current 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range ** without spark suppression 3,0 Insulation terms Coil to control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 10mm Output contacts as against each other: Double or reinforced insulation > 8mm 2,5 Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 2 1 Current (A) SIR332 No. of operations x 1000 Control side Output side 10 000 1 2,0 1,5 2 1,0 UB 0,5 UN 0 0 20 40 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Options, accessories PCB socket see page 31 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 25 SIR 8 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil and output contacts (> 10mm) and contacts in one row (> 8mm) and as left to right contact side (> 10mm) - EN 50205, type A - Contact mounting: SIR262 2NO/6NC SIR352 3NO/5NC SIR442 4NO/4NC SIR532 5NO/3NC SIR622 6NO/2NC SIR712 7NO/1NC - Small external dimensions - Mean coil power 1.3W - Holding power 0.39W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime 2,9 0,3 32 20 0,4 2 5 7,5 5 7,5 5 7,5 5 3,75 37,9 0,5 3,1 3,75 1 3,75 12,5 12,5 O1,3 3,75 [mm] 37,9 2 5 7,5 5 7,5 5 7,5 5 3,1 Contact material AgSnO2+0,2m Au Type of contact Crest contact Rated switching capacity 250VAC 10A AC1 2'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 25A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 10A Switching capacity range* 0,06VA(W) to 2'500VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values SIR442 SIR532 SIR622 SIR712 Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 4,2 > 0,6 > 1,2 8,4 12,6 > 1,8 > 2,4 16,8 > 4,8 33,6 42,0 > 6,0 77,0 > 11,0 154,0 > 22,0 218 109 72 54,5 27,2 11,8 6,8 5,9 27,5 110 250 440 1'760 2'750 9'250 37'000 10 10 10 10 10 10 13 15 Ordering example SIR 3 5 2 24VDC Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 15ms Drop-out time** typically 4ms Bounce time of NO contact typically 6ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 6g Vibration resistance NO contact > 5g 10-200Hz NC contact 2g Test voltage 5'000Veff 1min coil- contacts Test voltage contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 60g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 40K/W Temperature limit for coil 125C Pollution degree 2 Overvoltage category III Resistance to short 1'000A SCPD 10A circuiting gG (pre-fuse) Insulation terms Coil to contacts: Double or reinforced insulation > 10mm All contacts in one row: Double or reinforced insulation > 8mm All contacts as left to right contact side: Double or reinforced insulation > 10mm ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland 100 DC 13: 24V 10 0.1 Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 0.5 1.0 10 5.0 Switching current (A) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A DC 13: 24V/7.5A/0.1 Hz UL 508: C600/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 10A 3 contacts each with 8.4A 4 contacts each with 7.3A 5 contacts each with 6.5A 6 contacts each with 6A Load limit curve with direct current 10 8 6 4 3 2 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 60 80 250 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 1 2,0 1,5 1,0 UB UN Tests, regulations DC 1: 24V AC 15: 230V Double or reinforced insulation Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 26 No. of operations x 1000 SIR352 ** without spark suppression Drop-out voltage at 20 C 6 12 18 24 48 60 110 220 Min. pick-up voltage at 20C Nominal voltage VDC Standard coils for direct current (other voltages on request) SIR262 AC 1: 230V 1000 Current (A) 85,5 10 000 2 0,5 0 0 20 40 100 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. SIR 10 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 8mm) and output contacts in one row (> 8mm) and as left to right contact side (> 10mm) - EN 50205, type A - Contact mounting: SIR372 3NO/7NC SIR462 4NO/6NC SIR552 5NO/5NC SIR642 6NO/4NC SIR732 7NO/3NC SIR822 8NO/2NC SIR912 9NO/1NC - Small external dimensions - Mean coil power 1.3W - Holding power 0.39W Circuit diagram (view on relay upper side) Contact lifetime 20 SIR462 SIR552 SIR642 0,3 3,75 5 7,5 5 7,5 5 7,5 5 7,5 5 0,5 3,1 3,75 12,5 1 3,75 12,5 O1,3 3,75 [mm] 2,0 25,4 5 7,5 5 7,5 5 7,5 5 7,5 5 3,1 Contact material AgSnO2+0.2m Au Type of contact Crest contact Rated switching capacity 250VAC 10A AC1 2'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 25A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 10mA to 10A Switching capacity range* 0.06VA(W) to 2'500VA Contact resistance (as delivered) <100m/28 V/100mA * Guide values Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 6 12 18 24 48 60 110 220 4,2 > 0,6 8,4 > 1,2 > 1,8 12,6 > 2,4 16,8 > 4,8 33,6 > 6,0 42,0 77,0 > 11,0 154,0 > 22,0 218 109 72 54,5 27,2 11,8 6,8 5,9 27,5 110 250 440 1'760 2'750 9'250 37'000 10 10 10 10 10 10 13 15 Min. pick-up voltage at 20C Nominal voltage VDC Standard coils for direct current (other voltages on request) Ordering example SIR 5 5 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 100 DC 13: 24V 10 0.5 1.0 10 5.0 Switching current (A) SIR732 32 2,9 0,4 25,4 DC 1: 24V AC 15: 230V 0.1 SIR822 SIR912 Basic insulation Double or reinforced insulation 2,0 No. of operations x 1000 SIR372 AC 1: 230V 1000 Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 18ms Drop-out time** typically 5ms Bounce time of NO contact typically 8ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 8g Vibration resistance NO contact > 10g 10-200Hz NC contact 5g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 60g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270 C/5s Thermal resistance 40K/W Temperature limit for coil 125C Pollution degree 2 Overvoltage category III Resistance to short circuiting output contacts 1'000A SCPD 10A gG (pre-fuse) Max. switching characteristics (determined acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/5A DC 13: 24V/7.5A/0.1 Hz UL 508: C600/R300 Maximal contact load at AC 1 with 230V: 2 contacts each with 10A 3 contacts each with 8.4A 4 contacts each with 7.3A 5 contacts each with 6.5A 6 contacts each with 6A 8 contacts each with 5A 9 contacts each with 4.2A Load limit curve with direct current 10 8 6 4 3 2 2 1 Current (A) 85,5 10 000 1 0,8 0,6 0,4 0,3 0,2 0,1 0 50 100 150 200 250 60 80 100 Voltage (VDC) 1) Inductive load, L/R 40 ms 2) Resistive load Excitation voltage range 1 2,0 1,5 ** without spark suppression Insulation terms Coil to control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 8mm All output contacts in one row: Double or reinforced insulation > 8mm All output contacts as left to right contact side: Double or reinforced insulation > 10mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 3 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland 1,0 UB UN 2 0,5 0 0 20 40 Ambient temperature C 1) Max. excitation voltage with contact load < 2A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 27 SIP 6 Contacts Relay data General data Diagrams - PCB relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (> 8mm) and output contacts in one row (> 8mm). - EN 50205, type A - Contact mounting: SIP512 Control contacts 1NO/1NC Output contacts 4NO SIP422 Control contacts 2NC Output contacts 4NO - Small external dimensions - Mean coil power 1.3W - Holding power 0.39W - For Railway Applications: EN 50155 Circuit diagram (view on relay upper side) Contact lifetime (output contacts) 32 0,3 12,5 0,4 25,4 6,5 3,75 2,1 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 1 3 14 3,75 6,5 12,5 O1,3 4,1 0,5 3 3,75 5 8,5 5 6,5 5 6,5 5 6,5 5 3,75 2,1 14 2,9 SIP512 [mm] 4,1 Control contacts Contact material AgSnO2+0.2m Au Rated switching capacity 250VAC 6A AC1 1'500VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 15A for 20ms Switching voltage range 5 to 250 VDC/VAC Switching current range* 5mA to 6A Switching capacity range* 0.06VA(W) to 1'500VA Contact resistance (as delivered) <100m/28 V/100mA Output contacts Contact material AgSnO2 Rated switching capacity 250VAC (440VAC) 16A AC1 4'000VA Electr. life AC1 (360 cycles/h) approx. 250'000 Inrush current max. 60A for 20ms Switching voltage range 5 to 480 VDC/VAC Switching current range* 10mA to 16A Switching capacity range* 0.12VA(W) to 4'000VA Contact resistance (as delivered)< 100m / 28 V / 100mA * Guide values 28 Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Tolerance in % 6 12 18 24 48 60 110 220 4,2 > 0,6 > 1,2 8,4 12,6 > 1,8 > 2,4 16,8 33,6 > 4,8 > 6,0 42,0 77,0 > 11,0 154,0 > 22,0 218 109 72,5 54,5 27,2 11,8 6,8 5,9 27,5 110 248 440 1'760 2'750 9'250 37'000 10 10 10 10 10 10 13 15 Min. pick-up voltage at 20C Nominal voltage VDC Standard coils for direct current (other voltages on request) ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Basic insulation Double or reinforced insulation Mechanical life > 10 x 106 operations Switching frequency, mechanical 15Hz Response time typically 18ms Drop-out time** typically 5ms Bounce time of NO contact typically 8ms Bounce time of NC contact typically 12ms Shock resistance 16ms NO contact > 10g NC contact 8g Vibration resistance NO contact > 10g 10-200Hz NC contact 5g Test voltage coil/control contacts 2'500Veff 1min Test voltage 5'000Veff 1min coil-control contacts/output contacts Test voltage output contacts as against each other 4'000Veff 1min Test voltage contact open 1'500Veff 1min Insulation resistance 1011 Creepage resistance CTI 250 Weight approx. 60g Mounting position any Ambient temperature -40C to +70C Type of protection RT II Solder bath temperature 270C/5s Thermal resistance 40K/W Temperature limit for coil 125C Pollution degree 2 Overvoltage category III Resistance to short circuiting control contacts 1'000A SCPD 6A gG (pre-fuse) Resistance to short circuiting output contacts 1'000A SCPD 16A gG (pre-fuse) No. of operations x 1000 Output side Control side SIP422 SIP512 DC 1: 24V 1000 DC 14: 24V 100 DC-13: 24V 10 5 1 10 16 Switching current (A) Contact lifetime (output contacts) 10 000 No. of operations x 1000 20 84,6 10 000 1000 AC 1: 230V AC 1: 400V 100 AC15: 230V 10 AC 3: 230V AC 3: 400V 5 1 10 16 Switching current (A) UL 508: A600/R150 Maximal contact load at AC 1 with 230V: 2 contacts each with 16A 3 contacts each with 12A 4 contacts each with 10A Excitation voltage range 1 2,0 1,5 1,0 2 ** without spark suppression UB Insulation terms Coil to control contacts: Basic insulation Coil/control contacts to output contacts: Double or reinforced insulation > 8mm All output contacts in one row: Double or reinforced insulation > 8mm Tests, regulations Approvals SEV, UL, cUL, TUV UL File E188953 Sec. 4 Insulation class IEC 60664-1 250VAC Protection class II VDE 0106 Fire protection requirements UL 94 / V0 Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 UN 0,5 0 0 20 40 60 80 100 Ambient temperature C 1) Max. excitation voltage with contact load: Control contacts <2A, output contacts <5A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Ordering example SI P 4 2 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com Accessories PCB socket SRP-SGR2 DIN rail socket SRD-SGR2 Modules for DIN rail sockets - - Module SRD-SGR2-M01 - For DIN rail socket SRD-SGR2 - Diode 6VDC to 230VDC (+ on terminal A1) PCB socket for SGR282Z, SIR282 With hold down clip Soldering tags for PCB 2.5mm pinning DIN rail socket for SGR282Z, SIR282 With plastic grip and marking tag (1 pc) Screw terminals 5mm pinning Assembly on DIN rail 35mm or single-hole mounting with M3 screw A1 + A2 - Module SRD-SGR2-M02 - For DIN rail socket SRD-SGR2 - Diode with red Led, 6VDC to 24VDC (+ on terminal A1) 15 24 42,5 4,8 12,7 3,2 A1 + 68,5 9,0 3 4,8 Module SRD-SGR2-M03 - For DIN rail socket SRD-SGR2 - Diode with green Led, 6VDC to 24VDC (+ on terminal A1) A2 - 6 10,8 60 31 [mm] 12 22 COIL A2 A1 NC NO 11 COM 24 14 21 15,5 O 1,5 [mm] 37,5 75 Technical data Rated current 2x8A Rated voltage 300VAC Test voltage coil/contacts 5'000Veff Insulation class (IEC 60664-1) 250VAC Creepage resistance CTI 250 Weight approx. 4g Ambient temperature -40C to +80C Packing unit 100 pcs Approvals UL, cUL UL File E113714 Technical data Rated current 2x8A Rated voltage 300VAC Test voltage coil/contacts 4'000Veff Insulation class (IEC 60664-1) 250VAC Creepage resistance CTI 250 Weight approx. 40g Ambient temperature -25C to +80C Cross sections for connection with - wires 2x2.5mm2 - end sleeves for strands 2x1.5mm2 Torque max. 0,8 Nm Packing unit 20 pcs Approvals UL, cUL UL File E113714 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Module SRD-SGR2-M04 - For DIN rail socket SRD-SGR2 - Red Led, 6VDC to 24VDC (+ on terminal A1) Module SRD-SGR2-M05 - For DIN rail socket SRD-SGR2 - Green Led, 6VDC to 24VDC (+ on terminal A1) Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 A1 + A2 - E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 29 Accessories PCB socket SRP-SIM4 DIN rail socket SRD-SIM4 - PCB socket for SIM 3 and 4 Contacts - With integrated retaining/ejector handles - Soldering tags for PCB - DIN rail socket for SIM 3 and 4 Contacts With integrated retaining/ejector handles Screw terminals Assembly on DIN rail 35mm or with 2xM3 screws 11,5 A2 A1 11 [mm] 31 24/21 44 23/22 31 33 46,7 16 SA-SIM4 ELESTA 4,1 71 7,5 34 12 O 1,5 15,9 43 5 5 5 3,4 0,5 40,2 60 SRD-SIM4 (SIM312...) 30 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Technical data Rated current 8A Rated voltage 250VAC Test voltage coil/contacts 2'500Veff Insulation class (IEC 60664-1) 250VAC Creepage resistance CTI 250 Weight approx. 65g Ambient temperature -25C to +70C Cross sections for connection with - wires 2x2.5mm2 - end sleeves for strands 2x1.5mm2 Torque max. 0.8 Nm Packing unit 10 pcs Approvals UL, cUL UL File E301947 Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 44 33 23 11 34 24 12 A1 A2 SRD-SIM4 (SIM222...) 43 44 33 21 11 34 22 12 A1 A2 [mm] 60 75,1 Technical data Rated current 7A Rated voltage 250VAC Test voltage coil/contacts 4'000Veff Insulation class (IEC 60664-1) 250VAC Creepage resistance CTI 250 Weight approx. 11g Ambient temperature -25C to +70C Packing unit 20 pcs Approvals UL, cUL UL File E301947 43 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com Accessories PCB socket SRP-SIR6 - PCB socket for SIR 4 Contacts - With integrated retaining/ejector handles - Soldering tags for PCB - PCB socket for SIR 6 Contacts - With integrated retaining/ejector handles - Soldering tags for PCB 21 SR-SIR4 ELESTA O 1,5 10 0,5 5 7,5 5 10,5 5 21 7,2 SR-SIR6 ELESTA [mm] 57 Technical data Rated current 7A Rated voltage 250VAC Test voltage coil/contacts 4'000Veff Insulation class (IEC 60664-1) 250VAC Creepage resistance CTI 250 Weight approx. 15g Ambient temperature -25C to +70C Packing unit 20 pcs Approvals UL, cUL UL File E301947 O 1,5 10 3,4 5 19,4 5 10,5 19,4 0,5 3,4 44,7 44,7 PCB socket SRP-SIR4 [mm] 69,5 Technical data Rated current 7A Rated voltage 250VAC Test voltage coil/contacts 4'000Veff Insulation class (IEC 60664-1) 250VAC Creepage resistance CTI 250 Weight approx. 17g Ambient temperature -25C to +70C Packing unit 20 pcs Approvals UL, cUL UL File E301947 ELESTA relays GmbH, Heuteilstrasse 18, CH - 7310 Bad Ragaz, Switzerland Phone: +41 (0)81 303 54 00 Fax: +41 (0)81 303 54 01 E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com 31 CERTIFICATE Certificate of environmental compatibility Compatibility with the environment is of particular importance to ELESTA relays GmbH. All materials we process, the consumables, packaging products, cleaning agents etc. we use have been selected with a view to their eco-friendliness already for many years. Careful handling of the natural resources, lowest possible energy consumption, pendulum systems for input and auxiliary materials as well as optimized recycling processes are a matter of course for us. They extend far beyond what legislation demands. Conformity with the EU guideline 2002/95/EG of 27 January 2003 (RoHS) Our products comply with the legal requirements according to the EU guideline 2002/95/EG dated 27 January 2003 (RoHS: Restriction of Hazardous Substances). None or our products contain any of the substances listed below: * * Lead, mercury, cadmium, hexavalent chromium Polybromated biphenyle (PBB), polybromated diphenyle ether (PBDE) Soldering processes and suitability for the process Our products are suitable for all common soldering processes based on higher temperatures. It is the user`s responsibility, however, to check and confirm the suitability for the particular process in the individual case. Application consultancy ELESTA relays GmbH offers its customers comprehensive application consultancy also in the context of the RoHS directives and the environmental compatibility of ELESTA relays products. Bad Ragaz, 01 March 2005 Martin Kunschert General Manager Markus Gloor Quality Manager ELESTA relays GmbH Heuteilstrasse 18 CH - 7310 Bad Ragaz Switzerland Phone: Fax: E-Mail: Internet: +41 (0)81 303 54 00 +41 (0)81 303 54 01 admin@elestarelays.com http://www.elestarelays.com Quality without compromises Being specialized in the production of safety relays, we protect humans and equipment alike and assume a particular responsibility for our products. Every employee of ELESTA relays GmbH is aware of this obligation in his/her daily work. In numerous recorded inspection steps from the incoming materials over the production process with 100% checking right to dispatch we guarantee the safety and product quality required for relays with forcibly guided contacts - for the benefit of man and machine! Production mostly on the premises, sophisticated equipment and an experienced as well as highly motivated workforce ensure that our products are of highest quality. Extremely short delivery times are possible thanks to highly flexible order processing, even when special coils and customized relay variations or supplies of samples and pilot series are concerned. It is a matter of course for us to develop products with and for our clientele. In this way we guarantee that our customers get the right products for their specific applications. Our innovation leadership in relays with forcibly guided contacts is evident in the development, production, logistics as well as the selection of available relays and our competent application consultancy - for the benefit of our customers! Our process-oriented management system guarantees flat structures and short decision making. Continuous improvement processes, further education, contribution to standardizations and close contact to customers and suppliers are firmly in place. Swiss Quality" is a reality at ELESTA relays GmbH. 33 Notes 34 Notes 35 Switzerland ELESTA relays GmbH Heuteilstrasse 18 CH-7310 Bad Ragaz Switzerland Phone: Fax: E-Mail: Internet: +41 (0)81 303 54 00 +41 (0)81 303 54 01 admin@elestarelays.com http://www.elestarelays.com Germany ELESTA relays GmbH Sales office Frankfurt Grabenstrae 15 D-63500 Seligenstadt Germany Phone: Fax: E-Mail: Internet: +49 (0)6182 7876854 +49 (0)6182 7876857 admin@elestarelays.com http://www.elestarelays.com ELESTA relays GmbH Sales office Leipzig Unterer Haselberg 32 D-04683 Nauenhof Germany Phone: Fax: E-Mail: Internet: +49 (0)34293 473818 +49 (0)34293 459988 admin@elestarelays.com http://www.elestarelays.com See internet: http://www.elestarelays.com Worldwide Your ELESTA relays - partner: Er 050601 en / 11.2007 International sales