https://www.phoenixcontact.com/us/products/2904963 Repeater power supply - MACX PL-EX-RPSS-2I-2I - 2904963 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-wire measuring transducers and transmits the 4 - 20 mA signal from the Ex area to the safe area. 5-way electrical isolation, PLd, screw connection Product Features Key commercial data Packing unit 1 pc Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 12.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 C ... 60 C (Any mounting position) Ambient temperature (storage/transport) -40 C ... 80 C Maximum altitude 2000 m Permissible humidity (operation) 10 % ... 95 % (non-condensing) 05/18/2015 Page 1 / 5 https://www.phoenixcontact.com/us/products/2904963 Repeater power supply - MACX PL-EX-RPSS-2I-2I - 2904963 Technical data Ambient conditions Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Degree of protection IP20 Input data Signal input Intrinsically safe Current input signal 4 mA ... 20 mA Transmitter supply voltage > 16 V (at 20 mA) Output data Signal output Current output Current output signal 4 mA ... 20 mA (active) Transmission Behavior 1:1 to input signal Load/output load current output 450 (20 mA) 375 (24 mA) Output behavior in the event of an error < 3.6 mA (In the event of cable break at the input (as per NE 43)) > 22.5 mA (In the event of cable short circuit at the input (as per NE 43)) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%)) Max. current consumption < 100 mA (24 V / 20 mA) Power consumption < 1.4 W (at 24 V DC / 20 mA) Connection data Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 7 mm Screw thread M3 Connection method Screw connection Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm General Maximum transmission error < 0.1 % (of final value) Transmission error, typical < 0.05 % (of final value) 05/18/2015 Page 2 / 5 https://www.phoenixcontact.com/us/products/2904963 Repeater power supply - MACX PL-EX-RPSS-2I-2I - 2904963 Technical data General Maximum temperature coefficient < 0.01 %/K Step response (10-90%) < 1.3 ms (for 4 mA ... 20 mA step) Status display Green LED (supply voltage) Inflammability class according to UL 94 V0 Pollution degree 2 Surge voltage category II Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Emitted interference EN 61000-6-4 Housing material PA 66-FR Color yellow Designation Input/output, power supply Electrical isolation 300 Vrms (Rated insulation voltage (surge voltage category II; pollution degree 2, safe isolation as per EN 61010-1)) 2.5 kV (50 Hz, 1 min., test voltage) Designation Input/output Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Input/power supply Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Output 1/output 2/ power supply Electrical isolation 1.5 kV (50 Hz, 1 min., test voltage) Conformance CE-compliant, additionally EN 61326 ATEX II (1) G [Ex ia Ga] IIC/IIB II (1) D [Ex ia Da] IIIC II 3(1) G Ex nA [ia Ga] IIC T4 Gc IECEx [Ex ia Ga] IIC/IIB [Ex ia Da] IIIC Ex nA [ia Ga] IIC T4 Gc UL, USA / Canada UL 61010 Listed Data communication (bypass) HART function Yes Protocols supported HART Safety data Max. output voltage Uo 25.2 V Max. output current Io 93 mA Max. output power Po 587 mW Group IIC 05/18/2015 Page 3 / 5 https://www.phoenixcontact.com/us/products/2904963 Repeater power supply - MACX PL-EX-RPSS-2I-2I - 2904963 Technical data Safety data Max. external inductivity Lo 2 mH Max. external capacity Co 107 nF Group IIB Max. external inductivity Lo 4 mH Max. external capacity Co 820 nF Safety-related maximum voltage Um 253 V AC (125 V DC) Classifications eCl@ss eCl@ss 5.1 27210121 eCl@ss 6.0 27200206 eCl@ss 8.0 27210121 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 Approvals Approvals Approvals UL Listed / cUL Listed / GL / Functional Safety / cULus Listed Ex Approvals ATEX / IECEx / UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details UL Listed 05/18/2015 Page 4 / 5 https://www.phoenixcontact.com/us/products/2904963 Repeater power supply - MACX PL-EX-RPSS-2I-2I - 2904963 Approvals cUL Listed GL Functional Safety cULus Listed Drawings Block diagram OUT IN Sensor / Field PLC / DCS AI passive 4.2 - 4.2 CH1 + 4.1 4.1 3.2 3.2 CH1 active 3.1 3.1 HHT + HHT passive 5.2 - 5.2 CH2 + 5.1 5.1 active 2.2 2.2 CH2 2.1 HHT GND +24V 2.1 - + HHT 1.2 1.1 Power GND +24V Zone 0,1,2 Zone 20,21,22 Zone 2 Div. 1,2 Div. 1 Phoenix Contact 2015 (c) - all rights reserved http://www.phoenixcontact.com 05/18/2015 Page 5 / 5