Eaton.com/epdu Eaton ePDU Product Catalog Switch N to Eaton. 2 eaton corporation Enclosure Power Distribution Units Product line overview ................................................................................................................................................................................... 4 Choosing ePDU technologies ...................................................................................................................................................................... 5 Understanding ePDU technologies ............................................................................................................................................................. 6 Table of Contents Table of contents ePDU software options.................................................................................................................................................................................. 9 Data Center ePDU units ............................................................................................................................................................................... 10 Designed specifically for data centers and IT environments, Eaton's Data Center ePDUs range from basic power distribution to the ability to monitor and manage power consumption Basic ePDUs ................................................................................................................................................................................. 10 Provides reliable and cost-effective power distribution FlexPDUs and Hot Swap Maintenance Bypass. ................................................................................................................... 14 Increase power distribution from a single UPS / Enables easy UPS replacement without interruption to the connection load Monitored ePDUs......................................................................................................................................................................... 16 Remotely monitors the current draw of the unit and individual sections Advanced Monitored ePDUs ..................................................................................................................................................... 19 Provides outlet level monitoring for capacity planning and energy management Switched ePDUs .......................................................................................................................................................................... 20 Provides remote power monitoring of both voltage and current and provides outlet-level control for on/off/reboot capabilities Managed ePDUs .......................................................................................................................................................................... 22 Monitors and controls critical factors such as voltage, current and power factor down to the individual outlet Eaton Automatic Transfer Switches......................................................................................................................................... 25 Automatically transfers power from the primary source to the secondary source Industrial ePDUs ........................................................................................................................................................................................... 27 Frequently used in test and measurement applications, many of Eaton's Industrial ePDUs are designed to be controlled with Remote Emergency Power Off Rack Power Module .................................................................................................................................................................................... 41 Delivers up to 36 kW of power to loads of various voltages, power cords and layouts ePDU plugs and receptacles ...................................................................................................................................................................... 42 Power cables and accessories ................................................................................................................................................................. 43 Space-saving mounting options ................................................................................................................................................................ 44 Cable restraint and management .............................................................................................................................................................. 45 Racks and airflow management ................................................................................................................................................................ 46 Eaton provides a full line of racks and airflow management solutions to store, cool, power and secure critical IT equipment eaton.com/epdu 1.800.356.5794 3 Product line overview Product line overview Broad product portfolio Eaton(R) offers the largest selection of rack mounted power distribution units available on the market, we call these Eaton ePDU(R) units. Our complete suite of products is designed specifically to help you meet rapidly escalating requirements. High density power solutions Eaton offers a number of ePDUs to meet your high power density needs. We offer both rackmount, and vertical mount three-phase models ranging from 50A to 80A input capacities. These sophisticated units allow an entire rack of equipment to be powered from a single power cord input. 24x7 reliability through circuit breakers ePDUs use individual UL-rated branch circuit breakers that protect load segments (outlet groups), ensuring that an overloaded circuit does not affect other load segments, therefore increasing reliability. Typically, circuit breakers have flat rockers or are fully shrouded to prevent accidental on/off operation. Rugged design for optimal performance and quick installation Eaton ePDUs are designed to meet global safety standards. These units are engineered with rugged construction, have flexible mounting options, and multiple features ensuring the highest quality and customer satisfaction. Eaton engineers unique solutions for the most power intense environments. Interact with our ePDUs online! Please visit eaton.com/epdu to interact with different ePDU technologies. These tools provide you with an in-depth look of the technology of the units, plugs, receptacles and much more! 4 eaton corporation Enclosure Power Distribution Units Eaton ePDU product search wizard makes it easy! On eaton.com/epdu, Eaton's product search wizard is a simple interface that allows you to search over 1,000 products for the perfect solution. You can explore features, benefits and learn basic fundamentals of ePDUs, as well as interact with live demos. This search wizard allows you to filter ePDUs by: * Input plug * Output receptacle * Power rating * Function * TAA compliance The live search wizard walks you through power requirements and allows you to pick from specific ePDU inventories. Making the right decisions from the start can make a difference in the dependability and efficiency of an infrastructure. If you need help or have questions with a selection, you can use the live chat icon or call one of the listed support numbers on our website. Choosing ePDU technologies Choosing ePDU technologies Eaton's complete offering of ePDU products in the search wizard and in this catalog are designated as either: Top seller ePDUs - Eaton's most popular units Build-to-order ePDUs - Specialized units Custom ePDUs - Fully engineered unique configurations built to meet your desired solution Eaton ePDU catalog numbering system Eaton's smart style numbers help you understand our numbering system. Follow the example below to see what the letters and numbers mean within this ePDU catalog. Please note that this numbering scheme represents the majority of our part numbers, but not all. PW 1 04 BA 0U 006 Unique three-digit model identifier Branding 001-999 Unique for every model Note that alphas signify international style numbers PW = Eaton style number Form factor Input phase 1 = Single- / Split-phase 3 = Three-phase OU, 1U, 2U Function / communications Max kW rounded Two characters, 01- 23 BA = Basic MI = Ethernet Monitored SW = Switched AM = Advanced Monitored Eaton has introduced new part numbers to our product portfolio. Please see details below: ePBZ BZ = Basic eMA MA = Managed eAM AM = Advanced Monitored eaton.com/epdu 1.800.356.5794 5 Understanding ePDU technologies Understanding ePDU technologies Eaton's ePDU technologies satisfy the demand of every data center. Eaton ePDUs offer single and dual chassis, five technology options, the broadest power range in the market and the ability to manufacture custom ePDUs. They also offer an arrangement of outlets (number and type) for every region. Eaton ePDUs are distinguished for their quality, dependability and versatility. All products are designed for a specific application with an emphasis on safety and reliability. The Eaton line includes an extensive range of vertical, zero U products, which do not occupy server space in racks, as well as 1U and 2U formats. Environmental monitoring options are also available. Feature Rugged Construction Horizontal Products Vertical Products Local Current Display Current Monitoring Type Basic (BA) 3 3 3 Monitored Network (MI) Advanced Monitored (AM) 3 3 3 3 3 Section Switched (SW) Managed (MA) 3 3 3 3 3 3 3 3 3 Outlet Section Outlet 3 3 3 3 3 3 3 3 3 3 Voltage Monitoring Serial Interface Ethernet Interface Environmental Sensors 3 3* Automatic Transfer (AT) 3 3 *Available on some models Industrial ePDUs Frequently used in test and measurement applications, Eaton offers a variety of Industrial ePDU options, many which are designed to be controlled with Remote Emergency Power Off. Eaton offers a full range of products with this feature from basic North American models to 3-Phase international units. Use your own switches or simply plug-in our Remote Control Panel (RCP) into an ePDU. For more information on Eaton's line of Industrial ePDUs, refer to pages 27-40. 6 eaton corporation Enclosure Power Distribution Units Designed for reliable and cost-effective power distribution, Basic ePDUs have the form factor and receptacle choices to meet the needs of the demanding data center architect. With power levels ranging from 1.4 kW all the way to 17 kW, Eaton has the right Basic ePDU for any application. FlexPDUs and Hot Swap Maintenance Bypass (page 14) The Eaton FlexPDUs provide flexible output receptacle options from a single UPS. These products have a three-foot input cord, enabling them to be mounted in close proximity to the UPS. Ideal for maintenance and UPS replacement, the Eaton Hot Swap Maintenance Bypass facilitates hot-swappable UPS replacement without shutting down equipment connected to the UPS. Monitored Network (MI) (page 16) Understanding ePDU technologies Basic (BA) - rugged construction and flexible mounting options (page 10) Eaton Monitored ePDUs provide remote monitoring of the current draw of individual sections via Ethernet or serial communication. This capability, combined with state-of-the-art software allows you to aggregate the information from hundreds of ePDUs in one location. All Monitored ePDUs also include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers. Advanced Monitored (AM) - Current Monitoring Per Outlet (page 19) Eaton Advanced Monitored ePDUs provide high accuracy monitoring for high-density, mission-critical server applications. By monitoring power consumption and energy trends at the outlet level, you are able to truly manage your data center. Integrated with Eaton's management software, you can monitor these units from any computer on the network. The new advanced LCD display provides outlet and section current information, voltage and kilowatt-hour readings, all at a single glance. Switched (SW) - individual outlet switching and sequencing (page 20) Designed for data centers needing remote site management, the Switched ePDUs provide remote power monitoring of both voltage and current. The current is also displayed on a local two-digit current meter. These units also monitor both temperature and humidity. Managed (MA) (page 22) Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor. This level of information allows you to make the right decision when it comes to energy consumption in your data center. You can also control the power at the individual outlet level, switching it on, off or rebooting it. Integrated with Eaton's management software, you can control these units from any computer on the network server. The new advanced LCD display provides outlet and section current information, voltage add kilowatt-hour readings, all at a single glance. Eaton Automatic Transfer Switches (AT) (page 25) Designed for switching non phase synchronized AC power sources, the automatic transfer switch ePDUs intelligent circuitry monitors both inputs, providing a fast switch transfer from primary to secondary source power critical equipment without interruption. These ePDUs assure the highest level of redundancy to mission-critical applications. eaton.com/epdu 1.800.356.5794 7 Understanding ePDU technologies Why monitor? The unique monitoring function of Eaton ePDUs allows you to remotely monitor the current draw of individual outlets or sections over a network. This, combined with state-of-the-art software, allows the user to aggregate the information from hundreds of ePDUs in one location. All monitored ePDUs also include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers. This feature allows remote monitoring of current for capacity planning and energy management. Key features and benefits * * * Access circuit-level and ePDU-level information worldwide Get a global view across your ePDUs from any PC or server with Intelligent Power(R) Manager software (you can learn more about Intelligent Power Manager on page 9) Receive warnings and alarms remotely Advanced Monitoring Advanced monitoring allows you to monitor down to the individual outlet. Key features: * * * * * * Monitor power consumption in kilowatt hours at the individual outlet level requirement Readings available via Ethernet connection over a network (utilizing Eaton's Intelligent Power Manager software) Power consumption readings allow for power usage effectiveness (PUE) calculations Easy-read LCD screen reduces local monitoring time UL Listed (UL489) branch circuit breakers meet industry requirements Cisco EnergyWise Certified- Eaton's new ePDUs are Cisco EnergyWise Certified 400-volt solution Eaton 400V ePDUs limit energy loss through transformers by avoiding the 480-208V conversion. These units use European standard, three-phase 400V phase-to-phase and 230V phase-to-neutral to replace 208V phase-to-phase in the U.S. Operating power supplies at 230V versus 208V typically increases power supply efficiency. 400V ePDUs also distribute almost twice the power on the same copper to achieve multiple reductions. Eaton offers a unique power distribution solution for 400V applications. These applications include: * * * Containerized data centers Customers looking for global standard Progressive data centers looking for cost reductions and efficiency gains You can find 400V ePDUs featured in the Monitored, Switched and Managed sections of this catalog, as well as on eaton.com/epdu. 400V ePDU part numbers (for reference) Monitored * VPC2864-3861 * VPC2864-3862 8 Switched * IPV70U1-EP1-09L * IPV70U2-EP1-09L eaton corporation Enclosure Power Distribution Units Managed * eMA013 * eMA014 Eaton offers a number of software management tools for you based on the number of ePDUs you need to manage. Software Rack Quantity Best Supported Web Browser / Email Type of Software Application Cost 1-25 Included requires web browser Data Closet Small Network Stand Alone Included SNMP 1-1000 Integrates to Third party software Small to Large Enterprise Low-High IPM 1-200 Eaton software free to try Small to Medium Enterprise Low-Medium Power Xpert(R) 100-1000 Eaton enterprise solution Facility or Large Enterprise High ePDU software options ePDU software options Web browser / email alerts Every network connected ePDU comes standard with built-in web server and email alert capability. To connect to any ePDU using a standard web browser to configure, monitor and control. If your network allows connection to an SMTP server, the ePDU can be configured to send email alerts using a Post Office Protocol 3 email account. SNMP Every network-connected ePDU supports SNMP alerts and has a standard MIB available for integration into third party software solutions. SNMP supports full monitoring and control with read/write capability for all major variables. Cisco EnergyWise certification Cisco EnergyWise certification confirms Eaton's dedication to engineering quality IT products and speaks to the importance of power consumption and measurement in today's data center space. With Eaton ePDUs and Cisco Energywise Software you can monitor voltage, frequency, amps and watts for each receptacle on your network (available with Advanced Montiored and Managed ePDUs). Intelligent Power Manager (IPM) Eaton's Intelligent Power Manager software integrates seamlessly with our ePDUs, giving you the tools you need to monitor and manage the power in your data center environment. You can also measure power consumption and kWH, which will help you calculate power usage effectiveness of the devices attached. Better yet, our software is fully compatible with the most popular management platforms in the industry, including VMware, Microsoft and Citrix. Our software is free of charge for up to 10 nodes. Download and learn more today at eaton.com/intelligentpowermanager. Power Xpert software Eaton's IPM dashboard allows you to easily monitor your network Ideal as a facility enterprise solution, Power Xpert supports the full offering of Eaton's electrical products and offers support for thirdparty products. Power Xpert monitors alarms, logs current readings and environmental sensors on ePDU. There is a web-based dashboard view that allows you to drill down to a specific ePDU. Using the optional reporting package, it can generate customized power utilization reports. Power Xpert also allows you to customize the conditions under which alarms are triggered and can run deployment validation tools during installation so all key setup requirements are automatically validated. To learn more, please visit eaton.com/pxs. eaton.com/epdu 1.800.356.5794 9 Basic ePDUs Basic ePDUs - 0U Eaton Basic ePDUs provide reliable and cost-effective power distribution. Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) ePBZ98 ePBZ98 5-15P 15A 1.44 BA 6 0U (18) 5-15R 48.0 x 1.5 x 1.5 ePBZ89 ePBZ89 C14 None 1.44 BA 6 0U (16) C13 28.0 x 1.9 x 2.2 ePBZ75 ePBZ75 5-15P None 1.44 BA 15 0U (14) 5-15R 23.9 x 1.5 x 1.5 ePBZ73 ePBZ73 5-15P (1) 15A 1.44 BA 15 0U (18) 5-15R 48.0 x 1.5 x 1.5 ePBZ97 ePBZ97 5-20P (1) 20A 1.92 BA 6 0U (24) 5-20R 60.0 x 1.5 x 1.5 ePBZ96 ePBZ96 L5-20P (1) 20A 1.92 BA 6 0U (24) 5-20R 60.0 x 1.5 x 1.5 ePBZ74 ePBZ74 L5-20P/5-20P None 1.92 BA 15 0U (14) 5-20R 23.9 x 1.5 x 1.5 ePBZ72 ePBZ72 L5-20P/5-20P (1) 20A 1.92 BA 15 0U (18) 5-20R 48.0 x 1.5 x 1.5 ePBZ77 ePBZ77 L5-20P/5-20P (1) 20A 1.92 BA 15 0U (24) 5-20R 60.0 x 1.5 x 1.5 ePBZ71 ePBZ71 L5-20P/5-20P (1) 20A 1.92 BA 15 0U (30) 5-20R 72.0 x 1.5 x 1.5 ePBZ90 ePBZ90 L5-30P (2) 20A 2.88 BA 15 0U (24) 5-20R 40.0 x 1.9 x 2.1 V70BC2-N-SL-009 L5-30P (2) 20A 2.88 BA 9 0U (24) 5-20R 66.0 x 2.0 x 1.89 ePBZ93 L6-20P (1) 20A 3.33 BA 6 0U (20) C13, (4) C19 42.0 x 1.9 x 2.4 V70NB4-N-SL-009 L6-20P None 3.33 BA 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89 ePBZ93 ePBZ93 L6-20P None 3.33 BA 10 0U (20) C13, (4) C19 40.0 x 1.9 x 2.2 ePBZ92 ePBZ92 L6-30P (2) 20A 4.99 BA 6 0U (20) C13, (4) C19 42.0 x 1.9 x 2.2 PW105BA0U239 V70BF5-N-SL-009 L6-30P (2) 20A 4.99 BA 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89 PW105BA0U412 LPC1224-1P L14-30P (6) 15A 4.99 BA 6 0U (12) 5-15R 10.0 x 7.75 x 3.0 ePBZ80 L6-30P (2) 20A 4.99 BA 10 0U (30) C13, (6) C19 52.9 x 1.9 x 2.2 PW306BA0U241 VPC2864-A2-3846 L21-20P None 5.76 BA 9 0U (30) 5-20R 66.0 x 2.0 x 1.89 PW306BA0U244 VPC2864-3850 L21-20P None 5.76 BA 9 0U (36) C13, (6) C19 66.0 x 2.0 x 1.89 PW306BA0U246 VPC2864-3856 L21-20P None 5.76 BA 9 0U (18) 5-20R, (6) L6-20R 66.0 x 2.0 x 1.89 PW309BA0U409 VPC3106-C2-15 L21-30P (3) 20A 8.65 BA 9 0U (24) 5-20R 70.0 x 2.0 x 3.8 PW314BA0U251 VPC2864-3858 CS8365 (2) 20A (1) 30A 14.4 BA 9 0U (24) C13, (4) C19, (2) L6-30R 66.0 x 2.0 x 1.89 PW314BA0U253 VPC2864-3853 CS8365 (3) 20A 14.4 BA 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.89 Catalog Number PW103BA0U257 ePBZ93 PW103BA0U237 ePBZ80 10 eaton corporation Enclosure Power Distribution Units Basic ePDUs ePBZ89 ePBZ97 ePBZ93 PW105BA0U239 PW306BA0U244 PW314BA0U253 eaton.com/epdu 1.800.356.5794 11 Basic ePDUs Basic ePDUs - 1U Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101BA1U140 T982A1-N-SS-009 5-15P (1) 15A 1.44 BA 9 1U (12) 5-15R 1.75 x 19.0 x 7.0 ePBZ86 ePBZ86 5-15P None 1.44 BA 10 1U (12) 5-15R 1.7 x 17.3 x 2.3 ePBZ83 ePBZ83 5-15P None 1.44 BA 15 1U (12) 5-15R 1.7 x 17.3 x 2.3 T982A2-N-SS-009 5-20P (1) 20A 1.92 BA 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 ePBZ99 L5-20P (1) 20A 1.92 BA 6 1U (12) 5-20R 1.75 x 19 x 2.4 T982A2-N-SL-009 L5-20P (1) 20A 1.92 BA 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 ePBZ85 ePBZ85 5-20P None 1.92 BA 10 1U (12) 5-20R 1.7 x 17.3 x 2.3 ePBZ82 ePBZ82 L5-20P/5-20P1 None 1.92 BA 15 1U (12) 5-20R 1.7 x 17.3 x 2.3 T982C2-N-SL-009 L5-30P (2) 20A 2.88 BA 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 ePBZ84 ePBZ84 L5-30P (2) 20A 2.88 BA 10 1U (10) 5-20R 1.7 x 17.0 x 3.5 ePBZ78 ePBZ78 L5-30P (2) 20A 2.88 BA 15 1U (20) 5-20R 1.7 x 17.0 x 3.5 ePBZ88 ePBZ88 C20 None 3.33 BA 6 1U (10) C13, (2) C19 1.72 x 19.0 x 2.4 PW103BA1U405 TPC2104 C20 (1) 20A 3.33 BA 9 1U (16) C13 1.75 x 19.0 x 7.0 ePBZ95 ePBZ95 L6-20P None 3.33 BA 6 1U (12) C13, (1) C19 1.72 x 19.0 x 2.4 T982B3-N-SL-009 L6-20P (1) 20A 3.33 BA 9 1U (12) C13 1.75 x 19.0 x 7.0 ePBZ94 L6-30P (2) 20A 4.99 BA 6 1U (6) C19 1.72 x 19.0 x 2.4 PW103BA1U406 TPC2105-1-107 L6-30P (2) 15A 3.33 BA 9 1U (16) C13 1.75 x 19.0 x 7.0 PW105BA1U163 T982F3-N-SL-009 L6-30P (2) 15A 4.99 BA 9 1U (12) C13 1.75 x 19.0 x 7.0 PW105BA1U192 T982F4-N-SL-009 L6-30P (2) 15A 4.99 BA 9 1U (8) C13, (4) C19 1.75 x 19.0 x 7.0 PW105BA1U404 T982G1-N-SL-009 L14-30P (2) 15A 4.99 BA 9 1U (12) 5-15R 1.75 x 19.0 x 7.0 ePBZ91 ePBZ91 L6-30P (2) 20A 4.99 BA 10 1U (10) C13 1.7 x 17.0 x 3.5 ePBZ79 ePBZ79 L6-30P (2) 20A 4.99 BA 15 1U (16) C13, (4) C19 1.7 x 17.0 x 5.1 T17C19250-3-009 CS8365 (6) 20A 14.4 BA 9 1U (6) C19 1.75 x 19.0 x 7.0 PW102BA1U158 ePBZ99 PW102BA1U159 PW103BA1U190 PW103BA1U191 ePBZ94 PW314BA1U193 1. These units ship with an adapter allowing for 5-20P input plug. 12 eaton corporation Enclosure Power Distribution Units Rear view Basic ePDUs Front view PW101BA1U140 ePBZ99 ePBZ88 ePBZ95 ePBZ94 Front view Rear view PW105BA1U163 Front view Rear view PW314BA1U193 eaton.com/epdu 1.800.356.5794 13 FlexPDUs and Hot Swap Maintenance Bypass FlexPDUs Eaton FlexPDUs increase power distribution from a single UPS. * 3-foot cord allows easy connection close to UPS without cable clutter * Mounting bracket attaches directly to UPS * Mounting bracket allows for vertical, 1U or UPS attachment Hot Swap MBP mounted in rack with 3U UPS Style Number Input Plug Breaker Max kW Function Cord (ft)1 Orientation Receptacles Dimensions (H x W x D, in) EFLX1500R-PDU1U 58015 5-15P None 1.44 BA 3 1U (12) 5-15R, (1) C19 1.7 x 17.3 x 2.3 EFLX2000R-PDU1U 58020 5-20P None 1.92 BA 3 1U (12) 5-20R 1.7 x 17.3 x 2.3 EFLX2000R-PDU1UL 58021 5-20P None 1.92 BA 3 1U (5) L5-20R 2.0 x 17.3 x 3.0 EFLXI3000R-PDU1UIEC 68438 C20 Inlet (2) 20A 3.33 BA 3 1U (12) C13, (1) C19 1.7 x 17.3 x 2.3 Catalog Number 1. Includes C19 to C14 and C19 to C20 jumper cables Hot Swap Maintenance Bypass Hot Swap MBPs enable easy UPS replacement without interruption to the connected load. Placing the Hot Swap MBP in bypass mode provides utility power to equipment while the UPS is being serviced. Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) EHBPL1500R-PDU1U 58115 5-15P None 1.44 BA 8 2U (6) 5-15R 2.1 x 17.3 x 3.8 EHBPL2000R-PDU1U 58120 5-20P None 1.92 BA 8 2U (6) 5-15R 2.1 x 17.3 x 3.8 EHBPL3000R-PDU1U 58130 L5-30P (2) 20A 2.88 BA 3.3 2U (5) 5-20R 2.1 x 17.3 x 3.8 Catalog Number 14 eaton corporation Enclosure Power Distribution Units FlexPDUs and Hot Swap Maintenance Bypass FlexPDU mounted with 2U UPS EFLX1500R-PDU1U EFLX2000R-PDU1UL EFLXI3000R-PDU1UIEC EHBPL3000R-PDU1U eaton.com/epdu 1.800.356.5794 15 Monitored ePDUs Monitored ePDUs - 0U Eaton Monitored ePDUs enable you to remotely monitor the current draw of the unit and individual sections. Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101MI0U233 V70NA1-N-SS-109 5-15P None 1.44 MI 9 0U (24) 5-15R 66.0 x 2.0 x 1.89 PW102MI0U234 V70NA2-N-SS-109 5-20P None 1.92 MI 9 0U (24) 5-20R 66.0 x 2.0 x 1.89 PW102MI0U235 V70NA2-N-SL-109 L5-20P None 1.92 MI 9 0U (24) 5-20R 66.0 x 2.0 x 1.89 PW103MI0U236 V70BC1-N-SL-109 L5-30P (1) 15A 2.88 MI 9 0U (24) 5-15R 66.0 x 2.0 x 1.89 PW103MI0U238 V70NB4-N-SL-109 L6-20P None 3.33 MI 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89 PW105MI0U240 V70BF5-N-SL-109 L6-30P (2) 20A 4.99 MI 9 0U (24) C13, (4) C19 66.0 x 2.0 x 1.89 PW105MI0U255 V70BJ3-N-SL-109 L14-30P (2) 20A 4.99 MI 9 0U (24) C13, (4) C19, (4) 5-20R 66.0 x 2.0 x 1.89 PW306MI0U242 VPC2864-A2-3847 L21-20P None 5.76 MI 9 0U (30) 5-20R 66.0 x 2.0 x 1.89 PW306MI0U243 VPC2864-3848 L21-20P None 5.76 MI 9 0U (24) C13, (3) C19, (6) 5-20R 66.0 x 2.0 x 1.89 PW306MI0U408 VPC2864-A1 L21-20P None 5.76 MI 9 0U (30) 5-15R 66.0 x 2.0 x 1.89 PW306MI0U245 VPC2864-3851 L21-20P None 5.76 MI 9 0U (36) C13, (6) C19 66.0 x 2.0 x 1.89 PW306MI0U247 VPC2864-3857 L21-20P None 5.76 MI 9 0U (18) 5-20R, (6) L6-20R 66.0 x 2.0 x 1.89 PW306MI0U416 VPC2864-3436 L21-20P None 5.76 MI 10 0U (42) C13 66.0 x 2.0 x 1.89 PW309MI0U248 VPC2864-3849 L21-30P (3) 20A 8.64 MI 9 0U (24) C13, (3) C19, (6) 5-20R 66.0 x 2.0 x 1.89 PW309MI0U250 VPC2864-3726 L21-30P (3) 15A 8.64 MI 9 0U (36) C13 66.0 x 2.0 x 1.89 PW309MI0U256 VPC2864-3852 L21-30P (3) 20A 8.64 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.89 PW314MI0U252 VPC2864-3859 CS8365 (2) 20A (1) 30A 14.4 MI 9 0U (24) C13, (4) C19, (2) L6-30R 66.0 x 2.0 x 1.89 PW314MI0U254 VPC2864-3854 CS8365 (3) 20A 14.4 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.89 PW317MI0U222 VPC3690 IEC309 460P9W (6) 20A 17.3 MI 7 0U (12) C13, (12) C19 66.0 x 4.0 x 1.89 VPC2864-3861 400V VPC2864-3861 IEC309 516P6W None 14.4 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.83 VPC2864-3862 400V VPC2864-3862 IEC309 532P6W (3) 20A 14.4 MI 9 0U (30) C13, (6) C19 66.0 x 2.0 x 1.83 These units have available temperature monitoring. Optional sensors SENSOR - T1-10 (1) Temperature sensor, 10' cable SENSOR - T2-10 (2) Temperature sensor, 10' cable each 16 eaton corporation Enclosure Power Distribution Units Monitored ePDUs PW306MI0U247 PW309MI0U248 PW309MI0U250 PW309MI0U256 PW317MI0U222 eaton.com/epdu 1.800.356.5794 17 Monitored ePDUs Monitored ePDUs - 1U/2U Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101MI1U221 T982A1-N-SS-109 5-15P (1) 15A 1.44 MI 9 1U (12) 5-15R 1.75 x 19.0 x 7.0 PW101MI1U403 T982A2-F-SS-109 5-20P (1) 20A 1.92 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 PW102MI1U160 T982A2-N-SL-109 L5-20P (1) 20A 1.92 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 PW103MI1U161 T982C2-N-SL-109 L5-30P (2) 20A 2.88 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 PW103MI1U162 T982B3-N-SL-109 L6-20P (1) 20A 3.33 MI 9 1U (12) C13 1.75 x 19.0 x 7.0 PW105MI1U164 T982F3-N-SL-109 L6-30P (2) 15A 4.99 MI 9 1U (12) C13 1.75 x 19.0 x 7.0 PW105MI1U165 T982F4-N-SL-109 L6-30P (2) 15A 4.99 MI 9 1U (8) C13, (4) C19 1.75 x 19.0 x 7.0 PW105MI2U402 PC3783 L6-30P (2) 20A 4.99 MI 15 2U (20) C13 3.44 x 19.0 x 7.0 PW317MI2U141 PC3623 IEC309 460P9W (6) 20A 17.29 MI 10 2U (12) C19 3.5 x 19.0 x 13.5 These units have available temperature monitoring. Optional sensors SENSOR - T1-10 (1) Temperature sensor, 10' cable SENSOR - T2-10 (2) Temperature sensor, 10' cable each Front view Rear view PW102MI1U160 Front view Rear view PW103MI1U162 Front view Rear view PW105MI1U165 Front view Rear view PW317MI2U141 18 eaton corporation Enclosure Power Distribution Units Eaton Advanced Monitored ePDU provides maximum power for both standard and blade server. Additionally this technology provides outlet level monitoring for capacity planning and energy management. Outlet Level Monitoring Input Plug1 Breakers Max kW Orientation Receptacles Dimensions (H x W x D, in) eAM008 3 L6-20P2 None 3.3 0U (20) C13, (4) C19 60.0 x 2.2 x 2.6 eAM001 3 L6-30P (2) 20A 5.8 0U (20) C13, (4) C19 68.0 x 2.2 x 2.6 eAM002 3 L21-20P None 5.8 0U (21) C13, (3) C19 60.0 x 2.2 x 2.6 eAM004 3 L21-30P (3) 20A 8.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6 eAM003 3 CS8365 (3) 20A 12.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6 eAM005 3 IEC 309-460P9W (6) 20A 17.3 0U (12) C13, (12) C19 72.4 x 2.2 x 2.6 Catalog Number Advanced Monitored ePDUs Advanced Monitored ePDUs 1. 10-ft cord length, all units 2. Detachable cordset, C20 cord is also included; 120V cords are optional. Please see accessories. Optional sensors EMP001 Environmental Monitoring Probe for Advanced Monitored and Managed ePDUs Key technology features * Outlet-level monitoring * High accuracy monitoring * Advanced LCD display * Flexible mounting * Color-coded section labeling eAM008 eAM004 eAM005 eaton.com/epdu 1.800.356.5794 19 Switched ePDUs Switched ePDUs Eaton switched ePDUs provide remote power monitoring of both voltage and current and provide outlet-level control for on/off/reboot capabilities. Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101SW0U224 IPV70A1-EP1-09S 5-15P None 1.44 SW 9 0U (16) 5-15R 66.0 x 2.0 x 1.89 PW102SW0U150 IPV42A2-EP1-09L L5-20P None 1.92 SW 9 0U (8) 5-15R 42.0 x 2.0 x 1.89 PW102SW0U151 IPV70A5-EP1-09L L5-20P None 1.92 SW 9 0U (24) 5-15R 66.0 x 2.0 x 1.89 PW103SW0U152 IPV70C5-EP1-09L L5-30P (2) 15A 2.88 SW 9 0U (16) 5-15R 66.0 x 2.0 x 1.89 PW103SW0U153 IPV70B2-EP1-10L L6-20P None 3.33 SW 10 0U (24) C13 66.0 x 2.0 x 1.89 PW105SW0U154 IPV70F3-EP1-09L L6-30P (2) 15A 4.99 SW 9 0U (16) C13 66.0 x 2.0 x 1.89 PW306SW0U155 IPV70K1-EP1-09L L21-20P None 5.76 SW 9 0U (24) 5-15R 66.0 x 2.0 x 1.89 PW306SW0U156 IPV70M1-EP1-09L L21-20P None 5.76 SW 9 0U (24) C13 66.0 x 2.0 x 1.89 PW309SW0U178 IPV70R1-EP1-09L L21-30P (3) 20A 8.64 SW 9 0U (24) C13 66.0 x 2.0 x 3.5 PW317SW0U400 IPV70T2-EP1-12L IEC309 460P9W (6) 20A 17.29 SW 12 0U (18) C13, (6) C19 66.0 x 2.0 x 4.0 PW317SW0U401 IPV70T1-EP1-12L IEC309 460P9W (6) 20A 17.29 SW 12 0U (12) C13, (12) C19 66.0 x 2.0 x 4.0 IPV70U1-EP1-09L IPV70U1-EP1-09L IEC309 516P6W None 14.4 SW 9 0U (24) C13 66.0 x 2.0 x 1.83 IPV70U2-EP1-09L IPV70U2-EP1-09L IEC309 516P6W None 14.4 SW 9 0U (18) C13, (6) C19 70.0 x 2.0 x 4.0 PW103SW2U4131 IPC3401-NET C20 (1) 20A 3.33 SW NA2 1U (8) C13 1.7 x 19.0 x 9.5 PW103SW2U4141 IPC3402-NET C20 (1) 20A 3.33 SW NA2 1U (8) 5-15R 1.7 x 19.0 x 9.5 PW105SW2U415 IPC36F4N2USW15L L6-30P (2) 20A 4.99 SW 9 2U (20) C13, (4) C19 3.5 x 19.0 x 9.5 PW105SW2U223 IPC36F4N2USW09L L6-30P (2) 20A 4.99 SW 9 2U (20) C13, (4) C19 3.5 x 19.0 x 9.5 1. Model does not have local or remote current or voltage monitoring but features local on/off buttons in addition to remote switching. 2. Input power cord sold separately. These units have available temperature monitoring. Optional sensors SENSOR - T1-10 (1) Temperature sensor, 10' cable SENSOR - T2-10 (2) Temperature sensor, 10' cable each 20 eaton corporation Enclosure Power Distribution Units SENSOR - T1H1-10 (1) Temperature and humidity sensor, 10' cable SENSOR - T2H1-10 (1) Temperature and humidity sensor, 10' cable (1) Temperature sensor, 10' cable Switched ePDUs PW101SW0U224 PW102SW0U150 PW103SW0U152 PW103SW0U153 PW105SW0U154 PW309SW0U178 eaton.com/epdu 1.800.356.5794 21 Managed ePDUs Managed ePDUs Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor down to the individual outlet. Outlet Level Monitoring Outlet Level Switching Input Plug1 Breakers Max kW Orientation Receptacles Dimensions (H x W x D, in) eMA012 3 3 L6-20P2 None 3.3 0U (20) C13, (4) C19 60.0 x 2.2 x 2.6 eMA006 3 3 L21-20P None 5.8 0U (21) C13, (3) C19 60.0 x 2.2 x 2.6 eMA010 3 3 L6-30P (2) 20A 5.8 0U (20) C13, (4) C19 68.0 x 2.2 x 2.6 eMA011 3 3 L21-30P (3) 20A 8.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6 3 3 IEC 309-516P6W None 11.5 0U (12) C13, (12) C19 68.0 x 2.2 x 2.6 eMA007 3 3 CS8365 (3) 20A 12.6 0U (21) C13, (3) C19 68.0 x 2.2 x 2.6 eMA009 3 3 IEC 309-460P9W (6) 20A 17.3 0U (12) C13, (12) C19 72.4 x 2.2 x 2.6 3 3 IEC 309-532P6W (6) 20A 17.3 0U (12) C13, (12) C19 72.4 x 2.2 x 2.6 Catalog Number eMA013 eMA014 400V 400V 1. 10-ft cord length, all units 2. Detachable cordset, C20 cord is also included; 120V cords are optional. Please see accessories. Optional sensors EMP001 Environmental Monitoring Probe for Advanced Monitored and Managed ePDUs 22 eaton corporation Enclosure Power Distribution Units Key technology features * Outlet-level monitoring * Outlet-level power switching (on/off/reboot) * High accuracy monitoring * Advanced LCD display * Flexible mounting * Color-coded section labeling Managed ePDUs Color-coded receptacles Advanced LCD display eMA012 eMA010 eMA009 eaton.com/epdu 1.800.356.5794 23 Managed ePDUs Managed Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor down to the individual outlet. Key features: * * * * * * Monitor and control power consumption at the outlet level, including on, off and reboot Advanced LCD display offers easy user-interface and vast power information Single-phase and three-phase configurations provide solutions for SMB and networking closets, large data centers and blade server applications PUE level 3 rating determines high energy efficiency Environmental monitoring probe tracks internal and external temperatures, giving you key information to help reduce cooling costs - needs to be ordered separately Cisco EnergyWise Certified- Eaton's new ePDUs are Cisco EnergyWise Certified Color-coded receptacles Environmental monitoring You can utilize the Environmental Monitoring Probe to track internal and external temperatures, humidity and contact closure. This information allows you to operate the ePDU up to 50C (122 F), in turn reducing cooling costs. (Part number EMP001). LEDs represent each outlet Advanced LCD display This new advanced LCD display provides outlet and section current information, voltage and kilowatt-hour readings, all at a single glance. The display is accompanied with a three-button interface that allows you to navigate through the user-friendly menu structure. Dual-color display blinks when a system alarm is detected, providing local notification. Network management interface 24 eaton corporation Enclosure Power Distribution Units Local buttons allow for easy navigation of the menu Serial port for local configuration and environmental monitoring, 10/100 Ethernet port for network connectivity The Eaton eATS ePDUs automatically transfer power from the primary source to a secondary source. Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PWATSS515002 T2235-A1-NNB09S (2) 5-15P None 1.44 AT 9 1U (8) 5-15R 1.72 x 19.0 x 7.0 66027 (2) 5-15P None 1.44 AT 6 1U (6) 5-15R 1.72 x 19.0 x 9.8 PWATSS520003 T2235-A2-NNB09S (2) 5-20P None 1.92 AT 9 1U (8) 5-20R 1.72 x 19.0 x 7.0 PWATSL520004 T2235-A2-NNB09L (2) L5-20P None 1.92 AT 9 1U (8) 5-20R 1.72 x 19.0 x 7.0 PWATSL530005 T2235-C2-CNB09L (2) L5-30P (1) 20A 2.88 AT 9 1U (8) 5-20R 1.72 x 19.0 x 9.5 PWATSL530007 T2235-3369 (2) L5-30P (1) 30A 2.88 AT 9 1U (1) L5-30R 1.72 x 19.0 x 7.0 PWATSSC20001 T2235-AB-NNBC20 (2) C20 None 1.92 AT NA1 1U (8) C13, (1) C19 1.72 x 19.0 x 7.0 66028 (2) C20 None 3.33 AT 6 1U (6) C13, (1) C19 1.72 x 19.0 x 9.8 PWATSL630006 T2235-F3-CNB09L (2) L6-30P (2) 15A 4.99 AT 9 1U (12) C13 1.72 x 19.0 x 7.0 PWATSL630008 T2235-3358 (2) L6-30P None 4.99 AT 9 1U (1) L6-30R 1.72 x 19.0 x 7.0 PULSTS1400R-1U PULSTS16AMPR-1U Eaton Automatic Transfer Switches Eaton Automatic Transfer Switches 1. Input power cord sold separately. eaton.com/epdu 1.800.356.5794 25 Eaton Automatic Transfer Switches Front view Rear view PWATSS515002 Front view Rear view PWATSL530007 Front view Rear view PWATSSC20001 Front view Rear view PWATSL630006 26 eaton corporation Enclosure Power Distribution Units Full Load Receptacles Circuit Breaker EMI/RFI Filter Surge Suppression Input Plug IPC3401 1920 VA @ 120V~ 3840 VA @ 240V~ (8) C13 (2) 20A 20A 270V C20 Inlet IPC3401-NET 1920 VA @ 120V~ 3840 VA @ 240V~ (8) C13 (2) 20A 20A 270V C20 Inlet IPC3402 1920 VA (8) 5-15R (1) 20A 20A 270V C20 Inlet IPC3402-NET 1920 VA (8) 5-15R (1) 20A 20A 270V C20 Inlet IPC3402-A2 1920 VA (8) 5-20R (1) 20A 20A 270V C20 Inlet IPC3402-A2-NET 1920 VA (8) 5-20R (1) 20A 20A 270V C20 Inlet IPC3402-2756 2880 VA (4) 5-20R, (4) 5-15R (1) 20A, (1) 10A N/A 270V L5-30P IPC3402-2930 2880 VA (8) 5-15R (1) 20A, (1) 10A N/A 270V L5-30P Catalog Number Ethernet Control Serial Control (RS232) Dimensions (H x W x D, in) No Yes 1.7 x 19.0 x 9.5 Yes Yes 1.7 x 19.0 x 9.5 No Yes 1.7 x 19.0 x 9.5 Yes Yes 1.7 x 19.0 x 9.5 No Yes 1.7 x 19.0 x 9.5 Yes Yes 1.7 x 19.0 x 9.5 10 Yes Yes 1.7 x 19.0 x 9.5 10 Yes Yes 1.7 x 19.0 x 9.5 Cord (ft) Power cables must be ordered separately. Refer to page 43 for power cable options. Industrial ePDUs Intelligent Power Control Please refer to page 43 for power cable assemblies to match your country specific requirements. (11) Indicator lights Outlet status * Main power to system-CB on * Individual power on to outlets 1-8 * Data acquisition and remote disable * Query the IPC for Outlet and Watch Dog status Remote or local control * Serial RS232 port (DB9 Male) for direct computer or modem connection * RS485 input/output for strapping up to 10 systems together over CAT.5 cable * Local: one on/off switch for each outlet * NET SYSTEMS ONLY: RJ45 for network connections (Ethernet) Remote disable With the push of a button, disable remote access to the IPC when needed Power supply Strapping * Strapping allows up to 10 IPCs (80 outlets) to be controlled at one address * Units are connected together via the RS485 "IN" and "OUT" connectors Multiple time delay (MTD) * Sequence power up and power down to outlets with a one second time delay (factory set) * Set power on sequence to any combination of outlets Set the MTD timing from 1 second to 999 seconds, i.e. 009 = 9 seconds Software controls The IPC3401 series features a full range power supply for operation at 100-240 Vac input/output * Multi-platform compatible * Control via terminal emulation software * Web interface for browser control EMI/RFI filtering Commands available * Common mode - line to ground * Differential mode - line to line * Filtered inlet isolates noise before entering the system * Refer to chart 3 on page 40 * IPC3402-2756 and IPC3402-2930 do not have filtering * All outlets on/off or specific outlets on/off * Set up and sequence on/off all outlets * Create password and unit address * Outlet naming (8 characters) * Set up, enable or disable Watch Dog * Display outlet and Watch Dog timer status * Automatically receive update outlet status whenever there's a change * Auto-reboot outlet 1 with a five-second delay on restart Spike/surge suppression (TVSS) * Line to line * Refer to chart 1 on page 40 * Multi-stage, both MOVs and SAPs eaton.com/epdu 1.800.356.5794 27 Industrial ePDUs Intelligent Power Control IPC3600 Series Full Load Ethernet/ Serial Receptacles Circuit Breaker EMI/RFI Filter Surge Suppression Input Plug Cord (ft) Dimensions (H x W x D, in) IPC3601 1920 VA @ 120V~ 3840 VA @ 240V~ Yes (8) C13 (1) 20A 20A Yes C20 Inlet Not Included 1.7 x 19.0 x 19.5 IPC3602 1920 VA Yes (8) 5-15R (1) 20A 20A Yes C20 Inlet Not Included 1.7 x 19.0 x 19.5 IPC3601-F3-3316 5760 VA Yes (8) C13 (2) 15A No Yes L6-30P 10 1.7 x 19.0 x 19.5 Catalog Number Rear view Front view IPC3601 Rear view IPC36XX IPC3602 (12) Indicator lights * Main power system on * Power on to outlets 1-8 * Two data and ethernet link EMI/RFI filtering * Common mode - line to ground * Differential mode -line to line * Filtered inlet isolates noise before entering the system * Refer to chart 4 on page 40 Software security * User name/password security * Settings allow the administrator to disable unused interfaces Software features * Serial RS232 via RJ22 connector on the rear. 6' RJ22 to DB9 cable included * Serial baud rate is 9600 default or 38,400 maximum * Ethernet (10/100) network via RJ45 connector on the rear. 6' network cable included * Network setup allows DHCP or any static public/private IP address * Administrator and multiple users can be configured * User level access can be limited to specific outlets * Unit and outlet names can be configured * Outlet groups can be created to perform an action on multiple outlets * Outlet control includes individual, group and all outlet global control * Outlet actions include on or off and reboot * Global sequence allows all the outlets to be turned on or off in a preset sequence up to 999 seconds * Outlet reboot automatically turns an outlet off and back on with one command at a preset time up to 999 seconds * Email notification allows up to two email addresses to receive notifications of alerts or events Software interfaces Auto-event scheduling * Web interface provides a graphic control interface through a Web browser * Telnet interface provides a text menu control interface with any terminal emulation software * SNMP allows read/write capability with trapping * Email notification system provides email alerts or logs showing user activity Administrator can configure on or off events for outlets or groups. The event occurs at the preset time daily or weekly. Spike/surge suppression * Line to neutral (or line) * Refer to chart 1 on page 40 Serial/ethernet 28 * Serial interface provides a text menu control interface with any terminal emulation software * FTP utility allows firmware upgrades eaton corporation Enclosure Power Distribution Units Catalog Number Full Load Receptacles EMI/RFI Filter Surge Suppression Cord (ft) Power Input Plug Serial Control (RS232) Ethernet Control Dimensions (H x W x D, in) IPC3400-A1 1440 VA (4) 5-15R 15A 270V 9 5-15P Yes No 3.4 x 9.0 x 5.8 IPC3400-A1-NET 1440 VA (4) 5-15R 15A 270V 9 5-15P Yes Yes 3.4 x 9.0 x 5.8 IPC3400-AB 1440 VA/2880 VA (4) C13 15A 270V 8 C14 Yes No 3.4 x 9.0 x 5.8 IPC3400-AB-NET 1440 VA/2880 VA (4) C13 15A 270V 8 C14 Yes Yes 3.4 x 9.0 x 5.8 Front view Industrial ePDUs Intelligent Power Control IPC3400 series Rear view IPC3400-A1-NET (6) Indicator lights Password protection * (1) Main power * (1) Data light * (4) Power on to outlets 1-4 For added security, a password feature is included which allows you to assign a three alphanumeric character password Communications The IPC comes with a default address but you can also create your own with any four alphanumeric characters * RS232, Serial: 9600 baud only * Optional ethernet control via RJ45 connector (add -NET to part number) * Data terminal emulation software is required to communicate with the IPC internal command codes such a telnet or hyperterminal EMI/RFI filtering * Common mode - line to ground * Differential mode - line to line * Refer to chart 2 on page 40 Spike/surge suppression * L-N, L-G, N-G * Refer to chart 1 on page 40 Outlet status Query the IPC for Outlet and Watchdog status, i.e. outlets are (on or off) Addressing Watch-dog/auto-reboot * The IPC monitors the control connection and automatically reboot itself if the connection locks up. The auto-reboot is activated by the time-out period running down to zero. When this occurs the IPC shuts down all outlets for four seconds and restart in the default or user defined sequence * Set the time out period to any number 0-9 where each digit represents 30 seconds, i.e. 3 = 120 seconds (user defined) Commands available * All outlets on/off * Individual outlet on/off * Set up and sequence on/off all outlets * Create password and unit address * Name outlets with eight character name * Set up, enable or disable Watchdog * Display outlet and Watchdog timer status Multiple time delay (MTD) * Turn outlets on or off at one time * Sequence power up and power down to outlets 1 - 4 with a four-second time delay (factory set) * Set power on sequence to any combination of outlets * Set the MTD timing from one second to 999 seconds, i.e. 009 = 9 seconds eaton.com/epdu 1.800.356.5794 29 Industrial ePDUs North American TPC115-10 series single-phase systems 120V~ OR 240V~, 15A, 20A and 30A, 50/60 Hz Catalog Number Full Load Receptacles Circuit Breaker EMI/RFI Filter Multi-Stage Surge Suppression Cord (ft) Input Plug Dimensions (H x W x D, in) TPC115-10-A 1440 VA (10) 5-15R (1) 15A 20A 270V/150V 9 5-15P 1.7 x 19.0 x 8.0 TPC115-10-A2 1920 VA (10) 5-20R (1) 20A 20A 270V/150V 9 5-20P 1.7 x 19.0 x 8.0 TPC115-10-B 2880 VA (10) 6-15R (2) 15A 20A 320V/270V 9 N/A 1.7 x 19.0 x 8.0 TPC115-10-C 2880 VA (10) 5-15R (2) 15A 30A 270V/150V 15 L5-30P 1.7 x 19.0 x 8.0 TPC115-10-D 2880 VA (10) 5-20R (2) 15A 30A 270V/150V 15 L5-30P 1.7 x 19.0 x 8.0 TPC115-10-F 5760 VA (10) 6-15R (2) 15A 30A 320V/270V 15 L6-30P 1.7 x 19.0 x 8.0 Front view Rear view TPC115-10-D (10) NEMA outlets Multiple time delay (MTD) * Two unswitched on front and eight switched on rear panel. Unswitched outlets are tied to the SW-II outlet section * Activated locally or remotely, SW-I outlets power up immediately, followed four seconds later by SW-II outlets which is followed four seconds later by the sequenced remote I/O port. * Add /MTD after part number, i.e. TPC115-10-A/MTD (3) Indicator lights * Main breaker power on and power to the unswitched outlets * Power on to the SW-I outlets * Power on to the SW-II outlets Spike/surge suppression * L-N, L-G, N-G * Refer to Chart 1 on page 40 EMI/RFI filtering * Common mode line to ground * Differential mode line to line * Refer to page 40 Local/off/remote switching * Local: Power on or off to the switched outlets * Off: When breaker is on but this switch is in the off mode, you have power to the unswitched outlets only * Remote: Power on or off to the switched outlets via a remote device * Latching remote, on LT systems, has the selection switch wired for remote/off/remote - There is no local control 30 eaton corporation Enclosure Power Distribution Units Remote I/O ports * Three front/two rear (see page 39) * Remote on/off and EPO control, EPO overrides remote and local control * Sequence power up additional equipment down line (third connector on front panel) * Latching remote feature - (N/C) EPO, momentary start - Add -LT to the part number when the MTD feature is not being used - Add /LT to the part number when the MTD feature is used 110-125V/200-240V~,16A, Single Phase, 50/60 Hz Catalog Number Circuit Breaker Multiple Time Delay EMI/RFI Filter Surge Suppression Receptacles Remote Control Cord (ft) Input Plug Dimensions (H x W x D, in) TPC2365 (1) 20A No Yes (20A) 320V (12) C13 Standard Not Included C20 Inlet 1.7 x 19.0 x 8.0 TPC2365/MTD (1) 20A Yes Yes (20A) 320V (12) C13 Standard Not Included C20 Inlet 1.7 x 19.0 x 8.0 TPC2365-LT (1) 20A No Yes (20A) 320V (12) C13 Latching Not Included C20 Inlet 1.7 x 19.0 x 8.0 TPC2365/LT (1) 20A Yes Yes (20A) 320V (12) C13 Latching Not Included C20 Inlet 1.7 x 19.0 x 8.0 TPC2365-2980 (1) 10A Yes Yes (30A) 320V (12) C13 Latching 15 Bare Wire 1.7 x 19.0 x 8.0 TPC2365-3732 (1) 10A Yes Yes (30A) 320V (12) C13 Latching 15 L6-30P 1.7 x 19.0 x 8.0 Front view Industrial ePDUs International TPC2365 series single-phase systems Rear view TPC2365 EMI/RFI filter Remote interface * Differential mode - line to line * Common mode - line to ground * Refer to Chart 4 on page 40 * Remote on/off and EPO control - EPO overrides remote and local control * Sequence power up additional equipment down line (standard on all units * Latching remote LT models only - normally closed EPO, momentary start Spike/surge suppression * Line to line * Refer to Chart 1 on page 40 Remote selection switch * Local: Power on or off to the switched outlets * Off: When breaker is on but this switch is in the off mode, you do not have power to the outlets * Remote: Power on or off to the switched outlets via a remote device * Latching remote on LT models only, the selection switch is wired for remote/off/remote - There is no local control * Refer to page 39 for remote configurations Optional multiple time delay (MTD) * Activated locally or remotely, section 1 powers up, followed four seconds later by section 2 which is followed four seconds later section 3 then four seconds later the sequenced remote activates the next system in line (5) Indicator lights * Power to section 1, 2 and 3 * 115 Vac or 230 Vac input selected Auto-voltage selection The AVS system automatically senses the input voltage and adjusts the internal components to use that voltage for the output eaton.com/epdu 1.800.356.5794 31 Industrial ePDUs North American TPC4100 series three-phase systems 120/208V~ Three-Phase WYE, 20A and 30A, 50/60 Hz Receptacles Circuit Breaker Remote EMI/RFI Filter Surge Suppression Cord (ft) Input Plug Dimensions (H x W x D, in) TPC4100-A2 (12) 5-20R (3) 20A No 30A 150V 9 L21-20P 1.7 x 19.0 x 9.5 TPC4100-B (12) 6-15R (3) 15A No 30A 270V 9 L21-30P 1.7 x 19.0 x 9.5 (6) 5-15R, (6) 6-15R (3) 15A No 30A 150V 9 L21-30P 1.7 x 19.0 x 9.5 TPC4100-C (12) 5-15R (3) 15A No 30A 150V 9 L21-30P 1.7 x 19.0 x 9.5 TPC4100-D (12) 5-20R (3) 20A No 30A 150V 9 L21-30P 1.7 x 19.0 x 9.5 (6) 5-20R, (6) 6-20R (3) 20A Yes Latching No 150V 9 L21-30P 1.7 x 19.0 x 9.5 Catalog Number TPC4100-AB TPC3474 Front view Rear view TPC4100-AB EMI/RFI filtering * Common mode - line to ground * Differential mode - line to line * Refer to Chart 8 on page 40 Spike/surge suppression * Line to line * Refer to Chart 1 on page 40 (3) Indicator lights Provided for each phase power on via breaker 32 eaton corporation Enclosure Power Distribution Units 120/208V~ Three-Phase WYE, 30A, 50/60 Hz Catalog Number Main Secondary Unswitched Full Circuit EMI/ Circuit Duplex Surge Cord Load Per Receptacles Breaker RFI Breakers Circuit Suppression (ft) Phase (on/off Filter Per Phase Breaker switch) PC2641-D 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A 320V PC2641D-LT 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A PC2641-D/ MTD 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A PC2641-D/LT 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A Remote Control Multiple Time Delay 15 Standard Remote No L21-30P 3.4 x 19.0 x 14.5 320V 15 Latching Remote No L21-30P 3.4 x 19.0 x 14.5 30A 320V 15 Standard Remote Yes L21-30P 3.4 x 19.0 x 14.5 30A 320V 15 Latching Remote Yes L21-30P 3.4 x 19.0 x 14.5 Front view Input Plug Dimensions (H x W x D, in) Industrial ePDUs North American PC2641 series three-phase systems Rear view PC2641-D (14) NEMA outlets Multiple time delay (MTD) * Two unswitched outlets * 12 switched outlets, four per phase * PH-X powers up immediately, followed four seconds later by PH-Y, which is followed four seconds later PH-Z, then four seconds later the sequenced remote activates the next system in line * PC2641-D/MTD and PC2641-D/LT only models (4) Indicator lights * Main breaker power on to system and unswitched duplex * Power on to PH-X, -Y, -Z outlets Spike/surge suppression * 320V MOV L-N * Refer to Chart 1 on page 40 EMI/RFI filtering * Common mode - line to ground * Differential mode - line to line * Refer to Chart 9 on page 40 (4) Remote I/O ports * Remote on/off and EPO control, EPO overrides remote and local control * Sequence power up additional equipment down line (standard on all units) * Latching remote - normally closed EPO, momentary start. Units with LT in part number, i.e. PC2641-D-LT or /LT Local/off/remote switching * Local: Power on or off to the switched outlets * Off: When breaker is on but this switch is in the off mode, you will have power to the unswitched outlets only * Remote: Power on or off to the switched outlets via a remote device * When using the latching remote, the selection switch is wired for remote/off/remote. There is no local control. This system is designed to be controlled locally or remotely via a remote control panel (refer to pages 38-39). eaton.com/epdu 1.800.356.5794 33 Industrial ePDUs North American PC975 series three-phase systems 120/208V~ Three-Phase WYE, 30A, 50/60 Hz Main Circuit Secondary Unswitched Breaker Circuit Duplex (on/off Breakers Circuit switch) Per Phase Breaker EMI/RFI Filter Surge Suppression Receptacles Cord (ft) Input Plug Dimensions (H x W x D, in) Catalog Number Full Load Per Phase PC975, PC975-LT 2880 VA (4) 30A (3) 2-Pole 20/20 20A thermal reset 30A 270V (8) 5-20R and (3) L6-20R 15 L21-30P 3.4 x 19.0 x 14.5 PC975-1969, PC975-1969/LT 2880 VA (4) 30A N/A 20A thermal reset 30A 270V (8) 5-20R and (3) L21-30R 15 L21-30P 3.4 x 19.0 x 14.5 PC975-2109, PC975-2109-LT 2880 VA (4) 30A (3) 1-Pole 20 15A thermal reset 30A 270V (8) 5-15R and (3) L5-30R 15 L21-30P 3.4 x 19.0 x 14.5 Front view Rear view PC975 EMI/RFI filtering Multiple time delay (MTD) * Common mode - line to ground * Differential mode - line to line * Refer to Chart 9 on page 40 * Activated locally or remotely, PH-X powers up, followed four seconds later by PH-Y, which is followed four seconds later PHZ, then four seconds later the sequenced remote activates the next system in line Spike/surge suppression * 270V MOV L-N * Refer to Chart 1 on page 40 (4) Indicator lights * Main breaker power on * Power on to PH-X, Y and Z (4 N/O) Remote I/O ports * Remote on/off and EPO control, EPO overrides remote and local control * Sequence power up additional equipment down line (standard on all units) * Latching remote - (N/C) EPO, momentary start. LT systems Local/off/remote switching * Local: Power on or off to the switched outlets * Off: When breaker is on but this switch is in the off mode, you have power to the unswitched outlets only * Remote: Power on or off to the switched outlets via a remote device * When using the latching remote option, the selection switch is wired for remote/off/remote. There is no local control This system is designed to be controlled locally or remotely via a remote control panel (refer to pages 38-39). 34 eaton corporation Enclosure Power Distribution Units 120/208V~ or 230/400V~ Three-Phase WYE, 20A, 50/60Hz Catalog Number Full load Per Phase Main Circuit Breaker Receptacles EMI/RFI Filter Per Phase Surge Suppression Input Dimensions (H x W x D, in) PC302-I/MTD 1920 VA or 3680 VA (1) 20A (14) C13 20A 270V Terminal Block 3.4 x 19.0 x 14.5 PC302-I/LT 1920 VA or 3680 VA (1) 20A (14) C13 20A 270V Terminal Block 3.4 x 19.0 x 14.5 Front view Industrial ePDUs International PC302-I/MTD three-phase systems Rear view PC302-I/MTD EMI/RFI filter Remote control * Differential mode * Common mode * Refer to Chart 2 on page 40 * Remote on/off and EPO control, EPO overrides remote and local control * Sequence power up additional equipment down line * Latching remote - (N/C) EPO, momentary start on PC302-LT only Spike/surge suppression Multiple time delay (MTD) * Line to line * Refer to Chart 1 on page 40 Voltage selection switch * Select 120/208V~ or 230/400V~ input * 120/208V~ input with 120V~ output * 230/400V~ input with 230V~ output Local/off/remote switching * Local: on/off to switched outlets * Off: When breaker is on but this switch is in the off mode, you will have power to the unswitched outlets only * Remote: on/off to switched outlets via a remote control device * Latching remote, the selection switch is wired for remote/off/ remote. There is no local control on the PC302-I/LT Required Cable Assembly Options: * Activated locally or remotely, PH-X powers up, followed four seconds later by PH-Y, which is followed four seconds later PH-Z, then four seconds later the sequenced remote activates the next system in line (6) Indicator lights * Main power on * Power to phase X, Y and Z * 120/208V~ input selected * 230/400V~ input selected See pages 38-39 for optional control panels. CBL100: 20A with 12/5 cable 9' long terminated with a NEMA L21-20P for use in North America at 120/208V~ CBL102: 20A with 5x2.5mm Harmonized cable 9' long. A plug is not provided so that you can provide the country specific plug for use in Europe at 230/400V~ eaton.com/epdu 1.800.356.5794 35 Industrial ePDUs International PC2672 series three-phase systems 120/208V~ OR 230V/400V~, Three-Phase WYE, 30A, 50/60 Hz Catalog Number PC2672 Full Load Per Phase Circuit Breaker Secondary Listed Breakers, (1) Each For The C19 Outlets Secondary Listed Breakers, (1) Each For A Pair of C13 Outlets Receptacles EMI/RFI Filter Cord (ft) Dimensions (H x W x D, in) 2880 VA at 120/208V or 5520 VA at 230/400V (3) 30A (4) 16A (6) 10A (12) C13 (4) C19 (1) IEC309 32A 30A 5 5.2 x 19.0 x 16.5 Cable Assembly Options: CBL113: 10/5 cable 9' long terminated with a NEMA L21-30P at one end and a mating IEC309 connector at the other end. For use in North America at 120/208V~ CBL114: 5x4.0 mm harmonized cable 9' long with an IEC309 connector at both ends. For use in Europe at 230/400V~ Front view Voltage Selectable Rear view EMI/RFI filtering (4) Remote I/O ports * Common mode - line to ground * Differential mode - line to line * Refer to Chart 9 on page 40 * Two front / Two rear: one on each side is sequence and the other is for remote on/off and EPO control. The PC2672 is controlled remotely only * Latching remote - (N/C) EPO between pins 2 & 3, momentary start between pins 1 & 3 (3) Indicator lights * Power on to PH-X, -Y, -Z This system is designed to be controlled locally or remotely via a remote control panel (refer to pages 38-39). 36 eaton corporation Enclosure Power Distribution Units UPS extension systems Catalog Number Circuit Breaker Input Voltage Output Voltage EMI/RFI Filtering Surge Suppression Receptacles Cord (ft) Input Plug Dimensions (H x W x D, in) (4) 15A 120V~ / 30A 20V~ / 30A N/A N/A (8) 5-15R1 6 L5-30P 3.0 x 7.8 x 10.0 240V~ / 30A 240V~ / 30A N/A N/A (4) L6-30R 6 L6-30P 3.0 x 7.8 x 10.0 LPC120P LPC208-1P N/A LPC208-2P (3) 20A 240V~ / 30A 240V / 30A N/A N/A (3) L6-20R, (1) L6-30R 6 L6-30P 3.0 x 7.8 x 10.0 LPC1224-1P (6) 15A 120-240V~ / 30A 120V N/A N/A (12) 5-15R1 6 L14-30P 3.0 x 7.8 x 10.0 LPC2872-1 N/A 100-240V~ / 20A 100-240V~ / 20A N/A N/A (6) C13 C20 Inlet N/A 3.0 x 7.8 x 10.0 Industrial ePDUs Non-rackmount power distribution units 1. 15A thermal reset breaker for each duplex 2. Each L6-30R with a 2-pole 20A breaker and kick guard and (1) L6-30R unswitched outlet LPC120P LPC208-1P LPC1224-1P LPC208-2P LPC2872-1 eaton.com/epdu 1.800.356.5794 37 Industrial ePDUs Remote control panels Allows immediate and complete `power off' control from one button. Remote Type Dimensions (H x W x D, in) Color Receptacle Switch/EPO RCP100-GRY Standard 1.73 x 19.0 x 2.0 Gray None 2-position/normally open RCP100-BLK Standard 1.73 x 19.0 x 2.0 Black None 2-position/normally open RCP100-GRY-LT1 Latching 1.73 x 19.0 x 2.0 Gray None 3-position/normally closed RCP100-BLK-LT1 Latching 1.73 x 19.0 x 2.0 Black None 3-position/normally closed Model 1. Latching (LT) control panels must be ordered with power distribution units that are latching, identified by LT at the end of the part number. RCP100-BLK-LT Rack mounted On/off switch * Flush mounted, 18 GA. Steel * Painted FED-STD 595 #26559 light texture gray * Optional: Painted FED-STD 595 #26038 black * Remote cable is 15' long * RCP100-GRY: 2-position ON/OFF switch * RCP100-GRY-LT: 3-position spring return dial switch for OFF (turns unit off and holds off), ON (puts unit in a standby mode), START is a momentary action and powers up the unit Emergency Power Off (EPO) * RCP100-GRY: Locking (N/O) EPO button for PDUs with the standard 3-pin remote I/O port. Turn to reset. * RCP100-GRY-LT: Locking (N/C) EPO button for PDUs with the latching (LT) option. Turn to reset. * Per European requirements, there is a yellow square behind the EPO button 38 RCP100-GRY eaton corporation Enclosure Power Distribution Units Industrial ePDUs Sample remote circuits Standard remote control interface REMOTE START REQUIRES (2) CONDITIONS: 1. The on/off/remote switch must be in the remote position. 2. A maintained closure between pins 1 & 3 turns the unit on. REMOTE POWER OFF REQUIRES (1) CONDITION: Opening the maintained connection between pins 1 & 3 turns off the switched outlets. REMOTE EPO REQUIRES (1) CONDITION: A maintained contact between pins 2 & 3 turns off the switched outlets regardless of the position of the on/off/ remote switch. SEQUENCED REMOTE: Connect pins 1, 2 & 3 of the sequence port to pins 1, 2 & 3 on any remote port of the slave unit. (Do not connect to another sequence port!) The sequence port of the master unit activates four seconds after the final set of outlets turn on. Additional units may be daisy chained in this fashion. CAUTION! THIS TYPE OF REMOTE IS NOT TO BE SUBSTITUTED FOR A SAFETY INTERLOCK! EPO is normally open, so removing the EPO connection will not shut down the power to the unit. Latching remote LT control interface REMOTE START REQUIRES (2) CONDITIONS: 1. A maintained contact between pins 2 & 3. 2. A momentary contact between pins 1 & 3. REMOTE POWER OFF OR EPO REQUIRES (1) CONDITION: Opening the maintained connection between pins 2 & 3. Additional EPO or stop buttons can be connected in series between pins 2 & 3. This turns off the switched outlets regardless of the remote switch position. SEQUENCE REMOTE: Connect pins 1 & 2 of the sequence port to any remote port on another -LT unit. The sequence port activates four seconds after the final set of outlets turn on. (Do not connect to another sequence port!) NOTE: LT units are designed for remote operation only. Even when the REMOTE/OFF/LOCAL switch is set to LOCAL, the unit still requires a power request from the remote ports to turn the unit on. REMOTE OPERATION: Most Eaton units have more than one remote connector. Unless labeled as SEQUENCE they are wired in parallel. Connection to only one remote connector is required. It is recommended that an Eaton control panel be ordered for use with your PDU. Connectors are provided for those who wish to wire their own switches or control panels. We recommend using 14 AWG wire and not exceeding 50 feet for any remote cable. Mating control panels can be seen on our website at eaton.com/epdu. If additional remote connectors are needed: The female AMP connectors used in our Power Controllers are: three pin - part number 1-480304-0 and four pin part number 1-480425-0, and are used with AMP Socket Terminals, part number 60619-1. The mating male AMP connector is: three pin part number 1-480305-0, and four pin - part number 1-480426-0 and are used with AMP male contacts part number 60620-1. eaton.com/epdu 1.800.356.5794 39 Industrial ePDUs Industrial ePDUs environmental, surge suppression and EMI/RFI filter performance Chart 1: Chart 5: 025-3021 TVSS (Transient Voltage Surge Suppression) MOV Specifications EMI/RFI Filtering Common Mode Insertion Loss Mhz. Continuous AC Voltage 150 Vac 270 Vac 320 Vac Continuous DC Voltage 200 Vdc 360 Vdc 420 Vdc Max. DC Leakage 200 A 200 A 200 A Low Varistor Voltage Limit 212 Vdc 389 Vdc 462 Vdc Mhz. High Varistor Voltage Limit 243 Vdc 453 Vdc 540 Vdc dB. Nominal Varistor Voltage 236 Vdc 424 Vdc 503 Vdc Current For Varistor Voltage 1 mA 1 mA 1 mA Max. Clamp Voltage 8x20 s 360V 680V 810V Max. Clamp Voltage Test Current 100A 100A 100A Peak Current Rating (1 Pulse) 12000A 10000A 10000A Peak Current Rating (2 Pulse) 9000A 6500A 6500A Energy Rating (10x1000 s) 170J 325J 385J Energy Rating (8x20 s) Capacitance Impulse Response Time 170J 325J 385J 1700 pF 970 pF 820 pF 50 ns 50 ns 50 ns dB. .15 .50 1.0 5.0 10.0 30.0 6 19 28 42 45 50 Differential Insertion Loss .15 .50 1.0 5.0 10.0 30.0 2 40 60 65 57 55 Chart 6: 025-2833 EMI/RFI Filtering Common Mode Insertion Loss Mhz. .1 .5 1.0 5.0 10.0 20.0 50.0 dB. 18 40 48 62 80 70 60 Differential Insertion Loss Mhz. .1 .5 1.0 5.0 10.0 20.0 dB. 21 33 41 50 50 50 Chart 2: 001-3000 Chart 7: 025-4000 EMI/RFI Filtering Common Mode Insertion Loss EMI/RFI Filtering Common Mode Insertion Loss Mhz. .2 1.0 2.0 10.0 dB. 15 25 45 50 Mhz. .2 1.0 2.0 10.0 dB. 10 22 32 50 Mhz. dB. .05 .20 1.0 5.0 20.0 100.0 0 35 71 75 66 48 Differential Insertion Loss Mhz. dB. Differential Insertion Loss Mhz. .05 .20 1.0 2.0 5.0 10.0 dB. 20 30 72 63 58 51 Chart 3: 010-0317 Chart 8: 025-3031 EMI/RFI Filtering Common Mode Insertion Loss EMI/RFI Filtering Common Mode Insertion Loss .01 1 10 20 50 100 Mhz. 8 29 40 50 68 40 dB. .05 .15 .50 1.5 5.0 20.0 4 18 38 44 50 50 Differential Insertion Loss Mhz. dB. Differential Insertion Loss .01 1 10 20 50 100 Mhz. .05 .15 .50 1.5 5.0 20.0 8 23 45 58 32 28 dB. 12 20 40 60 50 50 Chart 4: 025-2023 EMI/RFI Filtering Common Mode Insertion Loss Mhz. dB. .15 .50 1.0 5.0 10.0 30.0 6 19 28 42 45 50 Differential Insertion Loss Mhz. dB. 40 .15 .50 1.0 5.0 10.0 30.0 6 6 30 50 30 30 eaton corporation Enclosure Power Distribution Units The Rack Power Module (RPM) delivers up to 36 kW (hardwire option required, BladeUPS connector limits to 12 kW) of power to loads of various voltages, power cords and layouts. The 3U RPM can be deployed in the same rack with the UPS and IT equipment; there's no need for a dedicated infrastructure rack. The resulting architecture has fewer cables to manage, fewer distribution points to monitor and greater flexibility for IT personnel to make changes without an electrician. This unit is typically deployed with the Eaton BladeUPS units. Features: * * * * * * * * Provides plug-and-play primary distribution of power from a three-phase input source to secondary power distribution devices Serves data center loads with various voltages, power cord configurations and layouts Distributes three-phase power to 12 poles, grouped into two sets of six poles, with choice of output receptacle types Power Equalizer LED display gives quick visual indication of each circuit's load, reducing possibility of overloads and breakers tripped off line Load information available from the front of the rack, no need to check individual power strips in the rear of the cabinet (hot isle) Branch circuit monitoring option allows easy load monitoring over the network Installs in only 3U of space in EIA 19" rack or enclosure (or wall mounted), all hardware included Enables customer installation and changes without the services of a licensed electrician Front view Rack Power Module Rack Power Module Rear view RPM part number guide (Base 3U RPM distribution box) Y 0 3 0 0 0 0 0 0 Input voltage 1 = 208V 2 = 400V Input cords/connection 0 = Hardwire 1 = BladeUPS Connector 208V 2 = IEC309-60 5 wire 3 = L21-30P 4 = BladeUPS Connector 400V Input cords length 0 = Hardwire 1 = 6 feet 2 = 10 feet 3 = 15 feet 4 = 20 feet Metering choices 1 = Power Equalizer 2 = Energy Management System, NO Card 3 = Energy Management System, with card Output receptacle plate #1 & #2 1 = L21-20R 9 = L14-30R 2 = L21-30R A = C13 (208V) 3 = L6-15R B = C19 (208V) 4 = L6-20R C = C13 (230V) International 5 = L6-30R D = C19 (230V) International 6 = 5-15R E = L15-20R 7 = 5-20R F = L15-30R 8 = L14-20R eaton.com/epdu 1.800.356.5794 41 ePDU plugs and receptacles ePDU plugs and receptacles Standard NEMA plugs 5-15 120V 15A 1 phase straight blade 6-20 208V 20A 1 phase straight blade L21-20 120/208V 20A, 3 phase wye L22-20 277/480V 20A 3 phase wye 5-20 120V 20A 1 phase straight blade L6-20 208V 20A 1 phase twist lock L21-30 120/208V 30A 3 phase wye L22-30 277/480V 30A 3 phase wye L5-20 120V 20A 1 phase twist lock L6-30 208V 30A, 1 phase L15-20 208V 20A 3 phase delta L5-30 120V 30A 1 phase twist lock L14-30 120/240V 30A 2 phase (split phase) L15-30 208V 30A 3 phase delta IEC320 C13 North American Europe C14 15 amp 10 amp C19 250 volts 250 volts C20 20 amp 16 amp 250 volts 250 volts The IEC advantage: The IEC320 and IEC309 connectors described below are the most commonly specified. The IEC connector system is used throughout the world. By utilizing an Eaton ePDU with the IEC connectors, you can attach the correct cable assembly for British, Australian, Continental European, North American and many other cable/connector configurations. This allows you to purchase and inventory one ePDU for shipment anywhere in the world. IEC309 30A 60A 30A 60A 60A 60A General ePDU environmental specifications Y X G 360P6 250V 332P6 250V 50A, 2P3W 250V 460P9 3O250V 50A, 3P4W 3O250V Y Y X X G HBLCS8265C 42 532P6 3OY230/400V G Z HBLCS8365C eaton corporation Enclosure Power Distribution Units 560P9 3OY120/208V 563P6 3OY230/400V * Operating temperature is 0 to 50C (32-122F) * Storage temperature is -40 to 70C (-40 to 158F) * Altitude maximum 10,000 ft. * Relative humidity is 95% max non-condensing By turning to Eaton, you can enjoy one-stop shopping for a full range of power quality and power distribution needs, including power cables. The Eaton cable portfolio includes nearly two dozen choices in three product categories including adapters, jumpers and splitters. All Eaton power cables are tested and certified for use with Eaton products, such as ePDUs, rack power modules (RPMs) and UPSs-- proven to deliver the reliability and service life needed for the most rigorous data center applications. Splitter cables Adapter cables CBL139 Splitter Cable L14-30R to (2) L6-30R (4 ft/2 ft) CBL143 Splitter Cable L14-30R to (2) L5-30R (4 ft/2 ft) 010-0032: C14 to 5-15R 125V, 15A 1 foot, 16 AWG/3-wire 010-9334: 5-15P to C19 125V, 15A straight blade 8-foot, 14 AWG/3-wire 010-9335: 5-20P to C19 125V, 20A straight blade 8-foot, 12 AWG/3-wire 010-9336: 6-15P to C19 250V, 15A straight blade 8-foot, 14 AWG/3-wire 010-9337: 6-20P to C19 250V, 20A straight blade 8-foot, 12 AWG/3-wire 010-9338: L5-15P to C19 125V, 15A twist-lock 8-foot, 14 AWG/3-wire 010-9339: L5-20P to C19 125V, 20A twist-lock 8-foot, 12 AWG/3-wire 010-9340: L6-15P C19 to 250V, 15A twist-lock 8-foot, 14 AWG/3-wire 010-9341: L6-20P to C19 250V, 20A twist-lock 8-foot, 12 AWG/3-wire CBL148 Splitter Cable L14-20R to (2) L5-20R (4 ft/2 ft) Jumper Cables 010-9342: C20 Male to C19 20A 8-foot, 12 AWG/3-wire CBL149 Splitter Cable L21-30R to (3) L5-30R (4 ft/2 ft/1 ft) 010-0034: 8-foot, 12 AWG/3-wire C19 to bare wire (Pig Tail) CBL150 Splitter Cable L21-20R to (3) L5-20R (4 ft/2 ft/1 ft) Additional accessories Power cables and accessories Power cables and accessories 010-0025: 8-foot 010-0027: 6-foot 010-0028: 4-foot 010-0029: 2-foot C14 to C13 010-9365 C14 to C19, 8-foot 010-9369-03 C20 to C13, 3-foot 010-9369-06 C20 to C13, 6-foot Outlet Caps 035-0113: C13 outlet cap 035-0119: C19 outlet cap Temperature & humidity sensors Optional sensors SENSOR - T1-10 (1) Temperature sensor, 10' cable EMP001 Environmental Monitoring Probe Advanced Monitored and Managed ePDUs only SENSOR - T2-10 (2) Temperature sensor, 10' cable each SENSOR - T1H1-10 (1) Temperature and humidity sensor, 10' cable SENSOR - T2H1-10 (1) Temperature and humidity sensor, 10' cable (1) Temperature sensor, 10' cable eaton.com/epdu 1.800.356.5794 43 Space-saving mounting options Space-saving mounting options Installing your new ePDU is quick and easy. There are models that mount horizontally in minimal rack space (1U or 2U), or vertically in rack side pockets or rear channels--or on a wall or floor, saving traditional U space for IT equipment. The units come with all mounting hardware included, ready to install. There's no need to purchase additional mounting hardware or accessories. Some units use a button-mount system and can be mounted in keyhole-type openings in popular racks, with no tools required. Space-saving mounting options Horizontal mounting Rack Mounting Hole Specification Table Mounting Brackets Are Detachable With Several Mounting Options Shown Front Flush Optional Zero-U Bracket Part Number - 001-1928-1 HOLE SPECIFICATION TABLE A 1.75 3.5 5.25 Y .25 .875 .875 Z 1.25 1.75 3.5 Vertical mounting Industry standard keyhole button mounting Tool-less Mounting Variable clip-foot mounting SUB-HRDWARE-017 Standard mounting included, brackets come attached to units. Attach clip foot to rail Snap ePDU to clip foot Mounting style for eAM and eMA only Benefits of vertical mounts Button mount with clip feet Blind mount to rail with clip feet Bracket mount with clip feet Mounting style for vertical Basic models with part numbers that start with EPBZ. For a detailed mounting process, please refer to our mounting video on eaton.com/epdu 44 eaton corporation Enclosure Power Distribution Units Eaton ePDUs can be mounted vertically, allowing you to save valuable space. You can mount them vertically in rack side pockets, rear channels - or on a wall, which allows you to save traditional U space for IT equipment. KIT-CABLRES-01 Transverse mounting KIT-CABLRES-08 * Prevent downtime and accidental disconnection * Secure cables/plugs to PDU * Cable ties provide highest level of retention * Black adjustable bracket versions allow front or rear mounting - KIT-CABLRES-01 - fits 9.5" deep units - KIT-CABLRES-03 - fits 7" deep units * Fixed bracket versions allow attachment to rear only - KIT-CABLRES-08 - Black Cable restraint and management Cable restraints and management Transverse mounting Vertical Models Cable Tray Rackmount Models Cable Tray V42 Series KIT-CABLRES-21 IPC34XX Series KIT-CABLRES-01 V70A1 Series KIT-CABLRES-24 IPC36XX Series KIT-CABLRES-01 V70A2 Series KIT-CABLRES-24 T17 KIT-CABLRES-03 V70AB Series KIT-CABLRES-22 T982 Series KIT-CABLRES-03 V70Bx Series KIT-CABLRES-24 TPC115-10 Series KIT-CABLRES-08 V70Cx Series KIT-CABLRES-24 T9092 Series KIT-CABLRES-08 V70F1 Series KIT-CABLRES-24 TPC2104 Series KIT-CABLRES-08 V70F2 Series KIT-CABLRES-24 TPC2105 Series KIT-CABLRES-03 TPC2234 Series KIT-CABLRES-08 V70F3 Series KIT-CABLRES-24 T2235-Ax Series (Black 7") KIT-CABLRES-03 V70F4 Series KIT-CABLRES-24 T2235-Cx Series (Black 9.5") KIT-CABLRES-01 V70G1 Series KIT-CABLRES-24 T2235-Fx Series (Black 9.5") KIT-CABLRES-01 V70H1 Series KIT-CABLRES-24 TPC4100 Series KIT-CABLRES-01 V70J1 Series KIT-CABLRES-24 VPC1917-1 KIT-CABLRES-23 VPC1917-4,-5 KIT-CABLRES-23 VPC1917-6 KIT-CABLRES-24 VPC1917-7 KIT-CABLRES-23 VPC2769-A2 KIT-CABLRES-24 VPC2769-B2 KIT-CABLRES-23 VPC2864 Series KIT-CABLRES-23 VPC3106 Series KIT-CABLRES-23 AM/MA Series KBLT01 You must purchase cables separately. eaton.com/epdu 1.800.356.5794 45 Racks and airflow management Racks and airflow management Once you've decided which Eaton ePDU is best for your application, it's time to find the perfect rack to install them in. Eaton's provides a full line of racks and airflow management solutions, for you to store, cool, power, manage and secure your critical IT equipment. To view our entire portfolio of solutions, please visit powerquality.eaton.com. Eaton Paramount enclosure system Our premier enclosure platform, Paramount not only supports an industry leading 2,200 pounds of equipment in a fully welded frame, but it is also designed to adapt to the ever-changing requirements of the data center through a scalable and modular approach. Speed of deployment is essential to any company when considering time to market. Paramount's modularity and building block design ensures quick reconfigurations and minimizes downtime, protecting your initial investment. Eaton Vantage S2 enclosure system The Vantage S2 enclosure platform was designed with change in mind, which is why so many Fortune 500 companies have standardized on it. Eaton's forward-thinking design engineers continue to develop scalable enclosure solutions to help customers store their latest technology without having to change enclosure platforms, allowing them to maximize their original investment. 46 eaton corporation Enclosure Power Distribution Units Racks and airflow management Active Airflow Manager Eaton's HCS pressure based system with active airflow, when combined with best practices, improves performance metrics considerably. Allocating the correct amount of airflow at known intake locations is the key to reducing energy consumption while increasing equipment performance. Best practices such as blanking panels, proper perforated tile placement and the reduction of bypass airflow must be employed to ensure desired results. HCS for third-party racks Convert existing enclosures to the HCS to eliminate the incremental capital expense associated with having to add more CRAC units or other supplemental cooling. Eaton Heat Containment System (HCS) Eaton's HCS is a simple, scalable and low cost rack-based solution to cool up to 25 kW or more per enclosure without the expense of adding supplemental CRAC units to your data center. This patented technology is available on Eaton's Paramount and Vantage S2 enclosure systems and can also be field retrofitted to most manufacturers' enclosures. The HCS contains and directs the heat exhaust of your IT equipment through the chimney that is attached to the top rear of the enclosure. The hot air is then ducted to your existing CRAC units through a plenum ceiling or high air returns. Photo courtesy of Humana Visit powerquality.eaton.com to view Eaton's entire portfolio of racks, enclosures and airflow management solutions eaton.com/epdu 1.800.356.5794 47 UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 Toll Free: 1.800.356.5794 Eaton.com/epdu CANADA Ontario: 416.798.0112 Toll free: 1.800.461.9166 LATIN AMERICA Aruba: 001 866 898 8812 Argentina (South Cone): +5411 4124 4000 Bahamas: 1 800 389 0368 Brazil: +55 113616 8500 Colombia: 01 800 518 1490 Costa Rica: 0 800 012 1716 Dominican Republic: 1 888 751 4862 Ecuador: from Andinatel: 1 999 170 (code after 800 is WSC 5649) El Salvador: 800 6772 Mexico: + 52 (55) 9000-5252 or 01 800 08 EATON (32866) Miami: 1 866 248 2224 Guatemala: 1 800 624 0099 Jamaica: 800 534 2102 Nicaragua: 001 800 220 1992 Panama: 00 800 226 6524 Peru: 0 800 54 514 Puerto Rico: 1 877 740 1707 Trinidad & Tobago: 1 800 206 0981 Venezuela: 0 800 100 8474 Eaton, Powerware, Power Xpert and ePDU are trade names, trademarks, and/or service marks of Eaton Corporation or its subsidiaries and affiliates. (c)2012 Eaton Corporation All Rights Reserved Printed in USA EPDUCAT March 2012