M295 (01/17)
1pulseelectronics-milaero.com
GATE DRIVE TRANSFORMER
Military/Aerospace Grade
Storage & Operating Temperature: -55ºC to +125ºC
60 V - µsec MAX
Lead fi nish: SN100
MSL: 3
1500Vrms isolation (380Vrms continuous)
X-1622NL Mechanical Schematic
Electrical Speci cations 25°C
Part 3,4
Number Turns Ratio Pri-Sec
Insulation
Max1
(V*µsec)
Primary Inductance
(µH MIN)
Leakage 2
Inductance
DCR Primary
(Ω MAX)
DCR Secondary
(Ω MAX)
X-1622NL 1:1:1 1500 VRMS 60 1800 0.60 1.60 1.60
1. The maximum volt-µsec rating limits the peak flux density to 2800 Gauss
when used in a unipolar drive application. For bi-polar drive applications a
maximum volt-µsec of two times this rating is acceptable (ie: 2* (volt*µsec
rating) Volt*µsec = (voltage applied to the primary) * dutycycle / Frequecy = V
* alpha / Freq_Hz = V * µsec
2. Leakage inductance is measured at primary terminals with all secondaries
shorted.
3. Optional Tape & Reel packaging can be ordered by adding a “T” suffix to
the part number (i.e. X-1622NL becomes X-1622NLT). Pulse complies to
industry standard tape and reel specification EIA481.
4.
The “NL” suffix indicates an RoHS-compliant part number. Sn63Pb37 Lead
Finish available on request.
5. The temperature of the component (ambient plus temperature rise) must
be within the stated operating temperature range.