5STF 09T1420
ABB s.r.o., Novodvorska 1768/138a, 142 21 Praha 4, Czech Republic
ABB s.r.o. reserves the right to change the data contained herein at any time without notice
TS - TR/255/07 Jul-10 2 of 11
Maximum Ratings Maximum Limits Unit
VRRM
VDRM
Repetitive peak reverse
and off-state voltage
Tj = -40 ÷ 125 °C, note 1
5STF 09T1420..1425
5STF 09T1220..1225 1 400 V
1 200 V V
ITRMS RMS on-state current
Tc = 70 °C, half sine waveform, f = 50 Hz 1 330 A
ITAVm Average on-state current
Tc = 70 °C, half sine waveform, f = 50 Hz 847 A
ITSM Peak non-repetitive surge
half sine pulse, VR = 0 V tp = 10 ms
tp = 8.3 ms 13 000
13 900 A
I2t Limiting load integral
half sine pulse, VR = 0 V tp = 10 ms
tp = 8.3 ms 845 000
800 000 A2s
(diT/dt)cr Critical rate of rise of on-state current
IT = ITAVm, half sine waveform, f = 50 Hz,
VD = 2/3 VDRM, tr = 0.3 µs, IGT = 2 A
800 A/µs
(dvD/dt)cr Critical rate of rise of off-state voltage
VD = 2/3 VDRM 1 000 V/µs
PGAVm Maximum average gate power losses 3 W
IFGM Peak gate current 10 A
VFGM Peak gate voltage 12 V
VRGM Reverse peak gate voltage 10 V
Tjmin - Tjmax Operating temperature range -40 ÷ 125 °C
Tstgmin -
Tstgmax Storage temperature range -40 ÷ 125 °C
Unless otherwise specified Tj = 125 °C
Note 1: De-rating factor of 0.13% VRRM or VDRM per °C is applicable for Tj below 25 °C