ADVANCE TECHNICAL
INFORMATION
Characteristic / Test Conditions
Maximum D.C. Reverse Voltage
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
Maximum Average Forward Current (TC = 85°C, Duty Cycle = 0.5)
RMS Forward Current
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
Symbol
VR
VRRM
VRWM
IF(AV)
IF(RMS)
IFSM
Symbol
VF
IRM
LS
Characteristic / Test Conditions
IF = 15A
Maximum Forward Voltage IF = 30A
IF = 15A, TJ = 150°C
Maximum Reverse Leakage Current VR = VR Rated
VR = VR Rated, TJ = 125°C
Series Inductance (Lead to Lead 5mm from Base)
STATIC ELECTRICAL CHARACTERISTICS (FRED)
UNIT
Volts
Amps
UNIT
Volts
µA
nH
MIN TYP MAX
2.5
2.5
2.2
250
500
10
APT11GF120BRD1
1200
15
29
110
MAXIMUM RATINGS (FRED) All Ratings: TC = 25°C unless otherwise specified.
ULTRAFAST SOFT RECOVERY PARALLEL DIODE
052-6258 Rev F 1-2003
Maximum Reverse Leakage Current
MIN TYP MAX
48 TBD
60
132
192
211
4.0 TBD
7 TBD
126
523
12
18
166
81
UNIT
ns
Amps
nC
Volts
A/µs
Characteristic
Reverse Recovery Time, IF = 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
Reverse Recovery Time TJ = 25°C
IF = 15A, diF/dt = -100A/µs, VR = 650V TJ = 100°C
Forward Recovery Time TJ = 25°C
IF = 15A, diF/dt = 100A/µs, VR = 650V TJ = 100°C
Reverse Recovery Current TJ = 25°C
IF = 15A, diF/dt = -100A/µs, VR = 650V TJ = 100°C
Recovery Charge TJ = 25°C
IF = 15A, diF/dt = -100A/µs, VR = 650V TJ = 100°C
Forward Recovery Voltage TJ = 25°C
IF = 15A, diF/dt = 100A/µs, VR = 650V TJ = 100°C
Rate of Fall of Recovery Current TJ = 25°C
IF = 15A, diF/dt = -100A/µs, VR =650V TJ = 100°C
DYNAMIC CHARACTERISTICS (FRED)
Symbol
trr1
trr2
trr3
tfr1
tfr2
IRRM1
IRRM2
Qrr1
Qrr2
Vfr1
Vfr2
diM/dt
APT11GF120BRD1