Rev. 1.1 6/15 Copyright © 2015 by Silicon Laboratories Si7023-A10
Si7023-A10
HUMIDITY/TEMPERATURE SENSOR WITH PWM OUTPUT
Features
Applications
Description
The Si7023 Humidity and Temperature Sensor is a monolithic CMOS IC
integrating humidity and temperature sensor elements, an analog-to-digital
converter, signal processing, calibration data, and a PWM output. The PWM
output may be filtered to produce an analog voltage output. The patented use of
industry-standard, low-K polymeric dielectrics for sensing humidity enables the
construction of low-power, monolithic CMOS Sensor ICs with low drift and
hysteresis, and excellent long term stability.
The humidity and temperature sensors are factory-calibrated and the calibration
data is stored in the on-chip non-volatile memory. This ensures that the sensors
are fully interchangeable, with no recalibration or software changes required.
The Si7023 is available in a 3x3 mm DFN package and is reflow solderable. It can
be used as a hardware- and software-compatible drop-in upgrade for existing RH/
temperature sensors in 3x3 mm DFN-6 packages, featuring precision sensing
over a wider range and lower power consumption. The optional factory-installed
cover offers a low profile, convenient means of protecting the sensor during
assembly (e.g., reflow soldering) and throughout the life of the product, excluding
liquids (hydrophobic/oleophobic) and particulates.
The Si7023 offers an accurate, low-power, factory-calibrated digital solution ideal
for measuring humidity, dew-point, and temperature, in applications ranging from
HVAC/R and asset tracking to industrial and consumer platforms.
Precision Relative Humidity Sensor
 ± 3% RH (max), 0–80% RH
High Accuracy Temperature Sensor
±0.4 °C (max), –10 to 85 °C
0 to 100% RH operating range
–40 to +125 °C operating range
Wide operating voltage
(1.9 to 3.6 V)
Low Power Consumption
Factory-calibrated
PWM Output
3x3 mm DFN Package
Excellent long term stability
Optional factory-installed cover
Low-profile
Protection during reflow
Excludes liquids and particulates
HVAC/R
Thermostats/humidistats
Respiratory therapy
White goods
Indoor weather stations
Micro-environments/data centers
Automotive climate control and
defogging
Asset and goods tracking
Mobile phones and tablets
Patent Protected. Patents pending
Ordering Information:
See page 18.
Pin Assignments
Si7023
Top View
Si7023-A10
2 Rev. 1.1
Functional Block Diagram
Si7023-A10
Rev. 1.1 3
TABLE OF CONTENTS
Section Page
1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Typical Application Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3. Bill of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
4.1. Relative Humidity Sensor Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4.2. Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.3. Prolonged Exposure to High Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.4. PCB Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.5. Protecting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4.6. Bake/Hydrate Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4.7. Long Term Drift/Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
5. PWM Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
6. Pin Descriptions: Si7023 (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
7. Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
8. Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
8.1. Package Outline: 3x3 6-pin DFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
8.2. Package Outline: 3x3 6-pin DFN with Protective Cover . . . . . . . . . . . . . . . . . . . . . .20
9. PCB Land Pattern and Solder Mask Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
10. Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
10.1. Si7023 Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
10.2. Top Marking Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
11. Additional Reference Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Si7023-A10
4 Rev. 1.1
1. Electrical Specifications
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
Parameter Symbol Test Condition Min Typ Max Unit
Power Supply VDD 1.9 3.6 V
Operating Temperature TA–40 +125 °C
Table 2. General Specifications
1.9 < VDD < 3.6 V; TA = –40 to 125 °C unless otherwise noted.
Parameter Symbol Test Condition Min Typ Max Unit
Input Voltage High VIH SELECT pin 0.7xVDD ——V
Input Voltage Low VIL SELECT pin 0.3xVDD V
Input Voltage Range VIN SELECT pin with respect to GND 0.0 VDD V
Input Leakage IIL SELECT pin 1 A
Output Voltage High VOH PWM1, PWM2 pins, IOH = –10 A VDD – 0.1
V
PWM1, PWM2 pins pin,
IOH = –0.5 mA, VDD = 2.0 V
VDD – 0.2
PWM1, PWM2 pins,
IOH = –1.7 mA, VDD = 3.0 V
VDD – 0.4
Output Voltage Low VOL PWM1, PWM2 pins; IOL = 2.5 mA;
VDD = 3.3 V
0.6 V
PWM1, PWM2 pins; IOL = 1.2 mA;
VDD = 1.9 V
0.4 V
Sample Rate RH and Temperature 2 Hz
Current
Consumption
IDD Average Current 150 300 A
Powerup Time tPU From VDD 1.9 V to PWM output
enabled, 25 °C
—4855
ms
From VDD 1.9 V to PWM output
enabled, full temperature range
——110
Si7023-A10
Rev. 1.1 5
Figure 1. PWM Interface Timing Diagram
Table 3. PWM Interface Specifications
1.9 VDD 3.6 V; TA = –40 to +125 °C unless otherwise noted.
Parameter Symbol Test Condition Min Typ Max Unit
PWM Frequency FPWM 1.00 1.22 1.40 kHz
PWM Duty Cycle DCPWM tH / tPWM 0 100 %
SELECT Setup Time tSS From SELECT transition to
PWM valid
500 ms
Si7023-A10
6 Rev. 1.1
Figure 2. RH Accuracy at 30 °C
Table 4. Humidity Sensor
1.9 VDD 3.6 V; TA = 30 °C
Parameter Symbol Test Condition Min Typ Max Unit
Operating Range1Non-condensing 0 100 %RH
Accuracy2, 3 0 – 80% RH ±2 ±3 %RH
80 – 100% RH See Figure 2
Repeatability/Noise 0.025 %RH RMS
Resolution 11 Bits
Response Time463% 1 m/s airflow, with or without cover 6 S
Drift vs. Temperature 0.05 %RH/°C
Hysteresis ±1 %RH
Long Term Stability3< 0.25 %RH/yr
Notes:
1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged
operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.
2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See section “4.1. Relative Humidity Sensor Accuracy” for more details.
3. Drift due to aging effects at typical room conditions of 30 °C and 30% to 50% RH. May be impacted by dust, vaporized
solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See section “4.7. Long
Term Drift/Aging” .
4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.
Si7023-A10
Rev. 1.1 7
Figure 3. Temperature Accuracy
Table 5. Temperature Sensor
1.9 VDD 3.6 V; TA = –40 to +125 °C unless otherwise noted.
Parameter Symbol Test Condition Min Typ Max Unit
Operating Range –40 +125 °C
Accuracy –10 °C< tA < 85 °C ±0.3 ±0.4 °C
–40 < tA < 125 °C Figure 3
Repeatability/Noise 0.04 °C RMS
Resolution 11 Bits
Response Time* 63% Unmounted device 0.7 s
Si7023-EB board 5.1
Long Term Stability 0.01 °C/Yr
*Note: Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary
dependent on system thermal mass and air-flow.
Si7023-A10
8 Rev. 1.1
Table 6. Thermal Characteristics
Parameter Symbol Test Condition DFN-6 Unit
Junction to Air Thermal Resistance JA JEDEC 2-Layer board,
No Airflow
256 °C/W
Junction to Air Thermal Resistance JA JEDEC 2-Layer board,
1 m/s Airflow
224 °C/W
Junction to Air Thermal Resistance JA JEDEC 2-Layer board,
2.5 m/s Airflow
205 °C/W
Junction to Case Thermal Resistance JC JEDEC 2-Layer board 22 °C/W
Junction to Board Thermal Resistance JB JEDEC 2-Layer board 134 °C/W
Table 7. Absolute Maximum Ratings1
Parameter Symbol Test Condition Min Typ Max Unit
Ambient temperature
under bias
–55 125 °C
Storage Temperature2–65 150 °C
Voltage on I/O pins –0.3 VDD+0.3V V
Voltage on VDD with
respect to GND
–0.3 4.2 V
ESD Tolerance HBM 2 kV
CDM 1.25 kV
MM 250 V
Notes:
1. Absolute maximum ratings are stress ratings only, operation at or beyond these conditions is not implied and may
shorten the life of the device or alter its performance.
2. Special handling considerations apply; see application note, “AN607: Si70xx Humidity Sensor Designer’s Guide”.
Si7023-A10
Rev. 1.1 9
2. Typical Application Circuits
The primary function of the Si7023 is to measure relative humidity and temperature. Figure 4 demonstrates the
typical application circuit to achieve these functions.
Figure 4. Typical Application Circuit for Relative Humidity and Temperature Measurement
Si7023-A10
10 Rev. 1.1
3. Bill of Materials
Table 8. Typical Application Circuit BOM for Relative Humidity and Temperature Measurement
Reference Description Mfr Part Number Manufacturer
C1 Capacitor, 0.1 F, 16 V, X7R, 0603 Various Various
R1 Resistor, 100 k, ±5%, 1/16W, 0603 Various Various
C2 Capacitor, 1 F, 16 V, X7R, 0603 Various Various
R2 Resistor, 100 k, ±5%, 1/16W, 0603 (optional) Various Various
C3 Capacitor, 1 F, 16 V, X7R, 0603 (optional) Various Various
U1 IC, Digital Temp/Humidity Sensor Si7023-A10 Silicon Labs
Si7023-A10
Rev. 1.1 11
4. Functional Description
Figure 5. Si7023 Block Diagram
The Si7023 is a digital relative humidity and temperature sensor that integrates temperature and humidity sensor
elements, an analog-to-digital converter, signal processing, calibration, polynomial non-linearity correction, and a
PWM output all in a single chip. The Si7023 is individually factory-calibrated for both temperature and humidity,
with the calibration data stored in on-chip, non-volatile memory. This ensures that the sensor is fully
interchangeable, with no recalibration or changes to software required. Patented use of industry-standard CMOS
and low-K dielectrics as a sensor enables the Si7023 to achieve excellent long term stability and immunity to
contaminants with low drift and hysteresis. The Si7023 offers a low power, high accuracy, calibrated and stable
solution ideal for a wide range of temperature, humidity, and dew-point applications including medical and
instrumentation, high reliability automotive and industrial systems, and cost-sensitive consumer electronics.
While the Si7023 is largely a conventional mixed-signal CMOS integrated circuit, relative humidity sensors in
general and those based on capacitive sensing using polymeric dielectrics have unique application and use
requirements that are not common to conventional (non-sensor) ICs. Chief among those are:
The need to protect the sensor during board assembly, i.e., solder reflow, and the need to subsequently
rehydrate the sensor.
The need to protect the senor from damage or contamination during the product life-cycle.
The impact of prolonged exposure to extremes of temperature and/or humidity and their potential effect on
sensor accuracy.
The effects of humidity sensor “memory”.
Each of these items is discussed in more detail in the following sections.
Si7023-A10
12 Rev. 1.1
4.1. Relative Humidity Sensor Accuracy
To determine the accuracy of a relative humidity sensor, it is placed in a temperature and humidity controlled
chamber. The temperature is set to a convenient fixed value (typically 25–30 °C) and the relative humidity is swept
from 20 to 80% and back to 20% in the following steps: 20% – 40% – 60% – 80% – 80% – 60% – 40% – 20%. At
each set-point, the chamber is allowed to settle for a period of 60 minutes before a reading is taken from the
sensor. Prior to the sweep, the device is allowed to stabilize to 50%RH. The solid trace in Figure 6, “Measuring
Sensor Accuracy Including Hysteresis,” shows the result of a typical sweep.
Figure 6. Measuring Sensor Accuracy Including Hysteresis
The RH accuracy is defined as the dotted line shown in Figure 6, which is the average of the two data points at
each relative humidity set-point. In this case, the sensor shows an accuracy of 0.25%RH. The Si7023 accuracy
specification (Table 4) includes:
Unit-to-unit and lot-to-lot variation
Accuracy of factory calibration
Margin for shifts that can occur during solder reflow
The accuracy specification does not include:
Hysteresis (typically ±1%)
Effects from long term exposure to very humid conditions
Contamination of the sensor by particulates, chemicals, etc.
Other aging related shifts ("Long-term stability")
Variations due to temperature (see Drift vs. Temperature in Table 4). RH readings will typically vary with
temperature by less than 0.05% C.
Si7023-A10
Rev. 1.1 13
4.2. Hysteresis
The moisture absorbent film (polymeric dielectric) of the humidity sensor will carry a memory of its exposure
history, particularly its recent or extreme exposure history. A sensor exposed to relatively low humidity will carry a
negative offset relative to the factory calibration, and a sensor exposed to relatively high humidity will carry a
positive offset relative to the factory calibration. This factor causes a hysteresis effect illustrated by the solid trace
in Figure 6. The hysteresis value is the difference in %RH between the maximum absolute error on the decreasing
humidity ramp and the maximum absolute error on the increasing humidity ramp at a single relative humidity
setpoint and is expressed as a bipolar quantity relative to the average error (dashed trace). In the example of
Figure 6, the measurement uncertainty due to the hysteresis effect is ±1.0%RH.
4.3. Prolonged Exposure to High Humidity
Prolonged exposure to high humidity will result in a gradual upward drift of the RH reading. The shift in sensor
reading resulting from this drift will generally disappear slowly under normal ambient conditions. The amount of
shift is proportional to the magnitude of relative humidity and the length of exposure. In the case of lengthy
exposure to high humidity, some of the resulting shift may persist indefinitely under typical conditions. It is generally
possible to substantially reverse this effect by baking the device (see section “4.6. Bake/Hydrate Procedure” ).
4.4. PCB Assembly
4.4.1. Soldering
Like most ICs, Si7023 devices are shipped from the factory vacuum-packed with an enclosed desiccant to avoid
any RH accuracy drift during storage and to prevent any moisture-related issues during solder reflow. The following
guidelines should be observed during PCB assembly:
Si7023 devices are compatible with standard board assembly processes. Devices should be soldered
using reflow per the recommended card reflow profile. See Section “9. PCB Land Pattern and Solder Mask
Design” for the recommended card reflow profile.
A "no clean" solder process is recommended to minimize the need for water or solvent rinses after
soldering. Cleaning after soldering is possible, but must be done carefully to avoid impacting the
performance of the sensor. See AN607 for more information on cleaning.
It is essential that the exposed polymer sensing film be kept clean and undamaged. This can be
accomplished by careful handling and a clean, well-controlled assembly process. When in doubt or for
extra protection, a heat-resistant, protective cover such as Kapton™ KPPD-1/8 polyimide tape can be
installed during PCB assembly.
Si7023s may be ordered with a factory-fitted, solder-resistant protective cover. This cover provides protection
during PCB assembly or rework but without the time and effort required to install and remove the Kapton tape. It
can be left in place for the lifetime of the product, preventing liquids, dust or other contaminants from coming into
contact with the polymer sensor film. See Section “7. Ordering Guide ” for a list of ordering part numbers that
include the cover.
Si7023-A10
14 Rev. 1.1
4.4.2. Rehydration
The measured humidity value will generally shift slightly after solder reflow. A portion of this shift is permanent and
is accounted for in the accuracy specifications in Table 4. After soldering, an Si7023 should be allowed to
equilibrate under controlled RH conditions (room temperature, 45–55%RH) for at least 48 hours to eliminate the
remainder of the shift and return the device to its specified accuracy performance.
4.4.3. Rework
To maintain the specified sensor performance, care must be taken during rework to minimize the exposure of the
device to excessive heat and to avoid damage/contamination or a shift in the sensor reading due to liquids, solder
flux, etc. Manual touch-up using a soldering iron is permissible under the following guidelines:
The exposed polymer sensing film must be kept clean and undamaged. A protective cover is
recommended during any rework operation (Kapton® tape or the factory installed cover).
Flux must not be allowed to contaminate the sensor; liquid flux is not recommended even with a cover in
place. Conventional lead-free solder with rosin core is acceptable for touch-up as long as a cover is in
place during the rework.
If possible, avoid water or solvent rinses after touch-up. Cleaning after soldering is possible, but must be
done carefully to avoid impacting the performance of the sensor. See AN607 for more information on
cleaning.
Minimize the heating of the device. Soldering iron temperatures should not exceed 350 °C and the contact
time per pin should not exceed 5 seconds.
Hot air rework is not recommended. If a device must be replaced, remove the device by hot air and solder
a new part in its place by reflow following the guidelines above.
*Note: All trademarks are the property of their respective owners.
Figure 7. Si7023 with Factory-Installed Protective Cover
Si7023-A10
Rev. 1.1 15
4.5. Protecting the Sensor
Because the sensor operates on the principal of measuring a change in capacitance, any changes to the dielectric
constant of the polymer film will be detected as a change in relative humidity. Therefore, it is important to minimize
the probability of contaminants coming into contact with the sensor. Dust and other particles as well as liquids can
affect the RH reading. It is recommended that a cover is employed in the end system that blocks contaminants but
allows water vapor to pass through. Depending on the needs of the application, this can be as simple as plastic or
metallic gauze for basic protection against particulates or something more sophisticated such as a hydrophobic
membrane providing up to IP67 compliant protection.
The Si7023 may be ordered with a factory-fitted, solder-resistant cover that can be left in place for the lifetime of
the product. It is very low-profile, hydrophobic and oleophobic. See section “7. Ordering Guide ” for a list of
ordering part numbers that include the cover. A dimensioned drawing of the IC with the cover is included in section
“8. Package Outline ” . Other characteristics of the cover are listed in Table 9.
4.6. Bake/Hydrate Procedure
After exposure to extremes of temperature and/or humidity for prolonged periods, the polymer sensor film can
become either very dry or very wet, in each case the result is either high or low relative humidity readings. Under
normal operating conditions, the induced error will diminish over time. From a very dry condition, such as after
shipment and soldering, the error will diminish over a few days at typical controlled ambient conditions, e.g., 48
hours of 45 %RH 55. However, from a very wet condition, recovery may take significantly longer. To accelerate
recovery from a wet condition, a bake and hydrate cycle can be implemented. This operation consists of the
following steps:
Baking the sensor at 125 °C for 12 hours
Hydration at 30 °C in 75% RH for 10 hours
Following this cycle, the sensor will return to normal operation in typical ambient conditions after a few days.
4.7. Long Term Drift/Aging
Over long periods of time, the sensor readings may drift due to aging of the device. Standard accelerated life
testing of the Si7023 has resulted in the specifications for long-term drift shown in Table 4 and Table 5. This
contribution to the overall sensor accuracy accounts only for the long-term aging of the device in an otherwise
benign operating environment and does not include the effects of damage, contamination, or exposure to extreme
environmental conditions.
Table 9. Specifications of Protective Cover
Parameter Value
Material PTFE
Operating Temperature –40 to 125 °C
Maximum Reflow Temperature 260 °C
IP Rating (per IEC 529) IP67
Si7023-A10
16 Rev. 1.1
5. PWM Output
During operation, the Si7023 takes a relative humidity and temperature measurement once per second and
converts the result into a pulse width modulated waveform. Two output pins are available for reading the
measurement results: PWM1 and PWM2. The information output on each pin is determined by the SELECT pin as
follows:
The duty cycle of the waveform on the PWM outputs corresponds to the relative humidity and temperature results
shown in the following equations. The PWM duty cycle varies linearly with the measurement result between the
minimum and maximum values:
Equation 1.
Equation 2.
In the typical application, the PWM output is filtered using an RC network to provide an analog output voltage that
varies linearly with RH and temperature. See Section “2. Typical Application Circuits” for the recommended
application circuit.
Due to normal variations in RH accuracy of the device as described in Table 4, it is possible for the measured value
of %RH to be slightly less than 0 when the actual RH level is close to or equal to 0. Similarly, the measured value
of %RH may be slightly greater than 100 when the actual RH level is close to or equal to 100. This is expected
behavior.
Table 10. PWM Outputs
Voltage on SELECT Pin PWM1 Output PWM2 Output
High RH Temperature
Low Temperature RH
RH 6125 DCPWM
+=
Temperature 46.85175.72 DCPWM
+=
Si7023-A10
Rev. 1.1 17
6. Pin Descriptions: Si7023 (Top View)
Pin Name Pin # Pin Description
PWM1 1 Pulse width modulated output #1
GND 2 Ground. This pin is connected to ground on the circuit board through a trace. Do not
connect directly to GND plane.
DNC 3 This pin should be soldered to pads on the PCB for mechanical stability. It can be electri-
cally floating or tied to VDD (do not tie to GND).
PWM2 4 Pulse width modulated output #2
VDD 5 Power. This pin is connected to power on the circuit board.
SELECT 6 Digital input that toggles between RH and temperature outputs on PWM1 and PWM2.
This pin should be pulled high or low (do not leave floating).
TGND Paddle This pad is connected to GND internally. This pad is the main thermal input to the on-
chip temperature sensor. The paddle should be soldered to a floating pad.
Si7023-A10
18 Rev. 1.1
7. Ordering Guide
Table 11. Device Ordering Guide
P/N Description Max. Accuracy Pkg Operating
Range (°C)
Protective
Cover
Packing
Format
Temp RH
Si7023-A10-IM Digital temperature/ humidity sensor –
industrial temp range
±0.4 °C ± 3% DFN 6 –40 to +125 °C N Tube
Si7023-A10-IMR Digital temperature/ humidity sensor –
industrial temp range
±0.4 °C ± 3% DFN 6 –40 to +125 °C N Tape &
Reel
Si7023-A10-IM1 Digital temperature/ humidity sensor –
industrial temp range
±0.4 °C ± 3% DFN 6 –40 to +125 °C Y Cut Tape
Si7023-A10-IM1R Digital temperature/ humidity sensor –
industrial temp range
±0.4 °C ± 3% DFN 6 –40 to +125 °C Y Tape &
Reel
Si7023-A10-YM0 Digital temperature/ humidity sensor –
automotive
±0.4 °C ± 3% DFN 6 –40 to +125 °C N Tube
Si7023-A10-YM0R Digital temperature/ humidity sensor –
automotive
±0.4 °C ± 3% DFN 6 –40 to +125 °C N Tape &
Reel
Si7023-A10-YM1 Digital temperature/ humidity sensor –
automotive
±0.4 °C ± 3% DFN 6 –40 to +125 °C Y Cut Tape
Si7023-A10-YM1R Digital temperature/ humidity sensor –
automotive
±0.4 °C ± 3% DFN 6 –40 to +125 °C Y Tape &
Reel
Note: The “A” denotes product revision A and “10” denotes firmware version 1.0.
Si7023-A10
Rev. 1.1 19
8. Package Outline
8.1. Package Outline: 3x3 6-pin DFN
Figure 10. 3x3 6-pin DFN
Table 12. 3x3 6-pin DFN Package Diagram Dimensions
Dimension Min Nom Max
A 0.70 0.75 0.80
A1 0.00 0.02 0.05
b 0.35 0.40 0.45
D 3.00 BSC.
D2 1.40 1.50 1.60
e 1.00 BSC.
E 3.00 BSC.
E2 2.30 2.40 2.50
H1 0.85 0.90 0.95
H2 1.39 1.44 1.49
L 0.35 0.40 0.45
aaa 0.10
bbb 0.10
ccc 0.05
ddd 0.10
eee 0.05
fff 0.05
Notes:
1. All dimensions shown are in millimeters (mm).
2. Dimensioning and Tolerancing per ANSI Y14.5M-1994.
Si7023-A10
20 Rev. 1.1
8.2. Package Outline: 3x3 6-pin DFN with Protective Cover
Figure 8 illustrates the package details for the Si7023 with the optional protective cover. Table 13 lists the values
for the dimensions shown in the illustration.
Figure 8. 3x3 6-pin DFN with Protective Cover
Table 13. 3x3 6-pin DFN with Protective Cover Package Diagram Dimensions
Dimension Min Nom Max
A 1.21
A1 0.00 0.02 0.05
A2 0.70 0.75 0.80
b 0.35 0.40 0.45
D 3.00 BSC.
D2 1.40 1.50 1.60
e 1.00 BSC.
E 3.00 BSC.
E2 2.30 2.40 2.50
F1 2.70 2.80 2.90
F2 2.70 2.80 2.90
h 0.76 0.83 0.90
L 0.35 0.40 0.45
R1 0.45 0.50 0.55
aaa 0.10
bbb 0.10
ccc 0.05
ddd 0.10
eee 0.05
Notes:
1. All dimensions are shown in millimeters (mm).
2. Dimensioning and Tolerancing per ANSI Y14.5M-1994.
Si7023-A10
Rev. 1.1 21
9. PCB Land Pattern and Solder Mask Design
Figure 9. Si7023 PCB Land Pattern
Table 14. PCB Land Pattern Dimensions
Symbol mm
C1 2.90
E 1.00
P1 1.60
P2 2.50
X1 0.45
Y1 0.85
Notes:
General
1. All dimensions shown are at Maximum Material Condition (MMC). Least Material
Condition (LMC) is calculated based on a Fabrication Allowance of 0.05 mm.
2. This Land Pattern Design is based on the IPC-7351 guidelines.
Solder Mask Design
3. All metal pads are to be non-solder mask defined (NSMD). Clearance between the
solder mask and the metal pad is to be 60 m minimum, all the way around the
pad.
Stencil Design
4. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls
should be used to assure good solder paste release.
5. The stencil thickness should be 0.125 mm (5 mils).
6. The ratio of stencil aperture to land pad size should be 1:1 for all perimeter pins.
7. A 2x1 array of 1.00 mm square openings on 1.30 mm pitch should be used for the
center ground pad to achieve a target solder coverage of 50%.
Card Assembly
8. A No-Clean, Type-3 solder paste is recommended.
9. The recommended card reflow profile is per the JEDEC/IPC J-STD-020
specification for Small Body Components.
Si7023-A10
22 Rev. 1.1
10. Top Marking
10.1. Si7023 Top Marking
10.2. Top Marking Explanation
Mark Method: Laser
Font Size 0.30 mm
Pin 1 Indicator: Circle = 0.30 mm Diameter
Upper-Left Corner
Line 1 Marking: TTTT = Mfg Code
Si7023-A10
Rev. 1.1 23
11. Additional Reference Resources
AN607: Si70xx Humidity Sensor Designer’s Guide
Si7023-A10
24 Rev. 1.1
DOCUMENT CHANGE LIST
Revision 0.9 to Revision 0.91
Modified pin numbering on page 1, in Figure 4,
and in Section 6.
Revision 0.91 to Revision 1.0
Updated Table 2, “General Specifications,” on
page 4
Updated Table 3, “PWM Interface
Specifications,” on page 5
Updated Table 4, “Humidity Sensor,” on page 6
Revision 1.0 to Revision 1.1
Updated Section 4.5.
Updated Table 9.
Updated Table 13.
Si7023-A10
Rev. 1.1 25
CONTACT INFORMATION
Silicon Laboratories Inc.
400 West Cesar Chavez
Austin, TX 78701
Tel: 1+(512) 416-8500
Fax: 1+(512) 416-9669
Toll Free: 1+(877) 444-3032
Please visit the Silicon Labs Technical Support web page:
http://www.siliconlabs.com/support/pages/contacttechnicalsupport.aspx
and register to submit a technical support request.
Patent Notice
Silicon Labs invests in research and development to help our customers differentiate in the market with innovative low-power, small size, analog-
intensive mixed-signal solutions. Silicon Labs' extensive patent portfolio is a testament to our unique approach and world-class engineering team.
Silicon Laboratories and Silicon Labs are trademarks of Silicon Laboratories Inc.
Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holders.
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice.
Silicon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from
the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed fea-
tures or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warran-
ty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Silicon Laboratories assume any
liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation
consequential or incidental damages. Silicon Laboratories products are not designed, intended, or authorized for use in applications intend-
ed to support or sustain life, or for any other application in which the failure of the Silicon Laboratories product could create a situation where
personal injury or death may occur. Should Buyer purchase or use Silicon Laboratories products for any such unintended or unauthorized
application, Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Silicon Laboratories:
Si7023-A10-IM1 Si7023-A10-IM Si7023-A10-IM1R Si7023-A10-IMR