1190A Coax - CATV Cable
For more information please
call
1-800-Belden1
See Put-ups and Colors
Description:
Series 6, 18 AWG solid .040" bare copper-covered steel conductor with Coreguard®, gas-injected foam polyethylene insulation, with
Coreguard® and flooding compound, Duobond® IV quad shield (60% and 40% coverage), polyethylene jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Coax 1
Total Number of Conductors 1
Series Type Series 6
AWG 18
Stranding Solid
Conductor Diameter .040 in.
Conductor Material BCCS - Bare Copper Covered Steel
INSULATION:
Insulation Material Gas-injected FPE - Foam Polyethylene
Insulation Diameter .180 in.
OUTER SHIELD:
Outer Shield Material Trade Name Duobond® IV
Outer Shield Type Tape/Braid/Tape/Braid
Outer Shield Material :
Layer Number Trade Name Type Material % Coverage (%)
1 Bonded Duofoil® Tape Bonded Aluminum Foil-
Polyester Tape-Aluminum
Foil
100
2 Braid AL - Aluminum 60
3 Duofoil® Tape Aluminum Foil-Polyester
Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Shield %Coverage 100 %
Outer Shield Flooding Grease CoreGuard®
OUTER JACKET:
Outer Jacket Material PE - Polyethylene
OVERALL NOMINAL DIAMETER:
Page 1 of
3
1190A Coax - CATV Cable
Overall Nominal Diameter .298 in.
MECHANICAL CHARACTERISTICS:
Operating Temperature Range -55°C To +80°C
Bulk Cable Weight 29 lbs/1000 ft.
Max. Recommended Pulling Tension 162 lbs.
Min. Bend Radius (Install) 3 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
EU CE Mark (Y/N) No
EU RoHS Compliant (Y/N) Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
SWEEP TEST:
Sweep Testing 5 MHz - 1 GHz
SUITABILITY:
Suitability - Burial Yes
PLENUM/NON-PLENUM:
Plenum (Y/N) N
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance 75 +/- 3 Ohms
Nom. Inductance .097 µH/ft
Nom. Capacitance Conductor to Shield 16.2 pF/ft
Nominal Velocity of Propagation 83 %
Nominal Delay 1.2 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C 2.8 Ohms/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg.C 4.8 Ohms/1000 ft
Minimum Structural Return Loss :
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Minimum Structural
Return Loss (dB)
5 1000 20
Max. Attenuation :
Page 2 of
3
1190A Coax - CATV Cable
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Max. Attenuation
(dB/100 ft.)
5 0.67
55 1.60
211 2.87
270 3.24
300 3.43
350 3.72
400 4.00
450 4.26
550 4.71
750 5.59
870 6.00
1000 6.54
Max. Operating Voltage - Non-UL 350 V RMS
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
1190A 0031000 #18 GIFHDLDPE
DBL SH PE 1000 31 ORANGE
C
1190A 0101000 #18 GIFHDLDPE
DBL SH PE 1000 30 BLACK
C
C = CRATE REEL PUT-UP.
Revision Number: 2 Revision Date: 09-07-2006
© Copyright 2006 Belden, Inc
All Rights Reserved.
Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment
For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-
2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU
ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-
2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the
Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information
provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product
itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory
information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations
based on their individual usage of the product.
Page 3 of
3