2.2 2 Stacklights E26 Series Contents Stacklights--E26 Series Description 2 Page E26 Series Product Identification . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Replacement Parts . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting Instructions . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 2 V7-T2-33 V7-T2-34 V7-T2-35 V7-T2-40 V7-T2-41 V7-T2-42 V7-T2-43 V7-T2-44 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Product Description Features The E26 stacklight unit is a modular system that provides illuminated and audible status indication in all directions. Easily assembled plug-in modular units include constant, flashing and strobe light units, as well as monotonal, bi-tonal, intermittent audible alarms. Stacklights may be assembled in a variety of configurations, which are identified in the Maximum Configurations table on Page V7-T2-33. Several lamp, color and mounting options further enhance the stacklight's versatility. 2 Modular construction Six lens colors Variety of lamp types and voltages Mono-tonal, bi-tonal and intermittent audible alarms Benefits Combination of visible and audible alarms Modular components reduce inventory requirements, increase flexibility Steady and flashing modes allow one light to signal multiple conditions No-tools assembly permits easy lamp replacement Standards and Certifications CE 60947-5-1 UL 508--File No. E131568 cUL C22.2 No. 14--File No. E131568 Ingress Protection Stacklight base and light units: IP65, NEMA 4, 4X and 13 Alarm units: IP20, NEMA 1 Electrical Shock Protection Stacklight base and light unit: IP2X Alarm units: IP0X 2 2 2 2 2 2 2 2 2 V7-T2-32 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com 2.2 Stacklights E26 Series Product Identification 2 Complete Stacklight Modules Level 3 Level 2 Standard Stacklight Base For use with incandescent or standard LEDs for steady, non-flashing illumination or with flashing LEDs for flashing illumination. Bases include terminal block for wiring, stacklight cover and gasket. See Page V7-T2-38. Flashing Stacklight Base Allows configuration of each light in the stack for either steady or 60 times per minute flashing illumination. Flashing circuit for use with incandescent lamps only. (Maximum allowable number of light modules is 2 at 12V, 4 at 24V and 6 at 48V and above.) See Page V7-T2-38. For flashing LEDs use standard base with flashing LED light module. Level 1 Xenon Strobe Sets are similar to standard lens/diffuser units, except each set consists of two lens units. The lower unit includes the electronics and is permanently fused to the upper unit which contains the Xenon lamp. Xenon units may be placed in any position in a complete stacklight unit. They will flash 60 times per minute when used with a standard or flashing base. See Page V7-T2-36. Alarms Stacklight Base Stacklights accept a maximum of six incandescent or LED light modules or two Xenon Flasher modules and can be mounted in any position on the stack. Alarm units are mounted in the top most position only. 2 2 2 2 2 2 Extension Tube 2 Mounting Base 2 2 2 Maximum Configurations Incandescent or LED Modules Xenon Modules Alarm Modules Max. Number of Modules 6 -- -- 6 5 -- 1 6 4 1 -- 5 3 1 1 5 2 2 -- 4 1 2 1 4 2 2 2 2 2 2 May be fitted to the top of a complete stacklight unit or directly to the stacklight bases, if desired. Available in three versions, each with adjustable sound levels. See Page V7-T2-39. 2 2 2 2 2 Light Modules 2 Available in a variety of colors for both incandescent lamps and LED lamps. To maximize illumination and light dispersion, incandescent units include an opal white diffuser while LED diffusers are clear. See Page V7-T2-36. 2 2 2 2 2 2 2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com V7-T2-33 2.2 Stacklights E26 Series 2 Catalog Number Selection 2 Stacklight Catalog Numbering System E26X 9 KM L 39R W - V 4 2 2 Mounting Base 1 Description Code 2 W 4 8 9 2 2 None (base mount) 3/4 in NPT hub, chrome Standard three-hole Standard four-hole 2 Code 2 W 2 HM JM KM MM 2 HU JU KU MU RU 2 2 Extension Tube 5 Description None (base mount) Gray Aluminum 20 mm 3/4 in NPT 160 mm 3/4 in NPT 360 mm 3/4 in NPT 760 mm 3/4 in NPT Black Aluminum 20 mm 3/4 in NPT 160 mm 3/4 in NPT 360 mm 3/4 in NPT 760 mm 3/4 in NPT Right angle 3/4 in NPT 2 Code 2 L F 2 Component Catalog No. -- E26S104 E26S108 E26S109 Code W Q N P Component Catalog No. -- E26BHM E26BJM E26BKM E26BMM E26BHU E26BJU E26BKU E26BMU E26BRU Stacklight Base Description Component Catalog No. 2 Standard E26BL E26BF_ Flashing 6 M E U V K Z X0 X2 X3 X4 X6 X9 2 2 2 2 2 2 None Mono-tonal Bi-tonal Intermittent Code V1 V2 V3 V4 V5 4 Component Catalog No. 2 -- E26BQ_ E26BN_ E26BP_ Light Module Description Code 0 2 3 4 6 9 W R G Y B A W1 R1 G1 Y1 B1 A1 Alarm Description Voltage 3 Description 12V 24V 48V 120V 240V Component Catalog No. 2 E26B0_ E26B2_ E26B3_ E26B4_ E26B6_ E26B9_ E26BW_ E26BR_ E26BG_ E26BY_ E26BB_ E26BA_ E26BW1_ E26BR1_ E26BG1_ E26BY1_ E26BB1_ E26BA1_ Clear incandescent Red incandescent Green incandescent Yellow incandescent Blue incandescent Amber incandescent White cluster LED with clear lens Red cluster LED with red lens Green cluster LED with green lens Yellow cluster LED with yellow lens Blue cluster LED with blue lens Amber cluster LED with amber lens White cylindrical LED with clear lens 4 Red cylindrical LED with red lens 4 Green cylindrical LED with green lens 4 Yellow cylindrical LED with yellow lens 4 Blue cylindrical LED with blue lens 4 Amber cylindrical LED with amber lens 4 Flashing white cluster LED with clear lens Flashing red cluster LED with red lens Flashing green cluster LED with green lens Flashing yellow cluster LED with yellow lens Flashing blue cluster LED with blue lens Flashing amber cluster LED with amber lens Xenon flasher with clear lens Xenon flasher with red lens Xenon flasher with green lens Xenon flasher with yellow lens Xenon flasher with blue lens Xenon flasher with amber lens E26BM_ E26BE_ E26BU_ E26BV_ E26BK_ E26BZ_ E26BX0_ E26BX2_ E26BX3_ E26BX4_ E26BX6_ E26BX9_ Voltage Codes 2 Voltage Code (Blank) No lamp supplied No LED supplied No LED supplied -- -- 2 V1 12 Vac/Vdc 12 Vac/Vdc 12 Vac/Vdc 12 Vac/Vdc 12 Vac/Vdc 2 V2 24 Vac/Vdc 24 Vac/Vdc 24 Vac/Vdc 24 Vac/Vdc 24 Vac/Vdc V3 48 Vac/Vdc 48 Vac/Vdc 48 Vac/Vdc 48 Vac/Vdc 48 Vac/Vdc 2 V4 120 Vac/Vdc 120 Vac 120 Vac 120 Vac 120 Vac/Vdc V5 240 Vac/Vdc 240 Vac -- 240 Vac 240 Vac/Vdc 2 Notes 1 Unless base mount is specified, an extension tube must be selected for a complete unit. 2 Component catalog numbers for flashing bases, alarm units and light modules are incomplete and require the addition of a suffix code to specify the required voltage rating. See table above. 3 If no voltage is specified, assembled stacklight will be supplied without lamps or LEDs. 4 240V not available for cylindrical LEDs. 5 For complete length (extension tube and base), see Page V7-T2-39. 6 Flashing base is for use with incandescent lamps. 2 2 2 V7-T2-34 Incandescent Lamp Cluster LED Cylindrical LED Xenon Flasher Flasher Base/Alarm Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com 2.2 Stacklights E26 Series Product Selection 2 Assembled Units 2 One-, Two- and Three-Light Assembled Stacklights Base mountable Incandescent or LED versions 24V and 120V versions 2 2 2 One-Light Unit Stacklight Volts AC/DC Alarm First Level Color Illumination Type Catalog Number 24V None Red Incandescent--steady E26XWWL2W-V2 24V None Red Cylindrical LED--steady E26XWWLR1W-V2 24V None Green Incandescent--steady E26XWWL3W-V2 24V None Green Cylindrical LED--steady E26XWWLG1W-V2 24V None Amber Incandescent--steady E26XWWL9W-V2 24V None Amber Cylindrical LED--steady E26XWWLA1W-V2 120V None Red Incandescent--steady E26XWWL2W-V4 120V 1 None Red Cylindrical LED--steady E26XWWLR1W-V4 120V None Green Incandescent--steady E26XWWL3W-V4 120V 1 None Green Cylindrical LED--steady E26XWWLG1W-V4 120V None Amber Incandescent--steady E26XWWL9W-V4 120V 1 None Amber Cylindrical LED--steady E26XWWLA1W-V4 2 2 2 2 2 2 2 2 2 2 Two-Light Unit Stacklight Volts AC/DC Alarm First Level Color 24V Illumination Type Second Level Color None Green Illumination Type Catalog Number Incandescent--steady Red Incandescent--steady E26XWWL32W-V2 24V None Green Cylindrical LED--steady 120V None Green Incandescent--steady Red Cylindrical LED--steady E26XWWLG1R1W-V2 Red Incandescent--steady E26XWWL32W-V4 120V 1 None Green Cylindrical LED--steady Red Cylindrical LED--steady E26XWWLG1R1W-V4 2 2 2 2 Three-Light Unit Stacklight Volts AC/DC 24V 24V Alarm First Level Color None Green None Green Illumination Type Second Level Color Incandescent--steady Amber Cylindrical LED--steady 2 Illumination Type Third Level Color Illumination Type Catalog Number Incandescent--steady Red Incandescent--steady E26XWWL392W-V2 Amber Cylindrical LED--steady Red Cylindrical LED--steady E26XWWLG1A1R1W-V2 2 120V None Green Incandescent--steady Amber Incandescent--steady Red Incandescent--steady E26XWWL392W-V4 120V 1 None Green Cylindrical LED--steady Amber Cylindrical LED--steady Red Cylindrical LED--steady E26XWWLG1A1R1W-V4 2 2 2 Note 1 LED modules have very low current draw and should not be used with triac output devices like PLC triac output modules. It is recommended that dry contact outputs be used to switch 120 Vac modules. 2 2 2 2 2 2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com V7-T2-35 2.2 2 2 2 2 2 E26 Series Light and Xenon Strobe Modules Light modules include lens diffusers which provide even illumination and eliminate hot spots. Light/LED Module Without bulb or LED 2 Xenon Strobe Module 2 2 12 Vac/Vdc 2 2 2 Xenon strobes emit a bright attention-getting white flashing light. Flash rate = 60/min. Xenon strobe modules occupy two positions in the stacklight assembly. Light and Xenon Strobe Modules 1 LED/Lamp Voltage 2 2 Stacklights Incandescent Cylindrical LED Cluster LED Cluster LED Xenon Lens Color Steady or Flashing Catalog Number Steady Only Catalog Number Steady Catalog Number Flashing Catalog Number Flashing Catalog Number Red E26B2 E26B E26BR E26BR -- Green E26B3 E26BG E26BG E26BG -- Yellow E26B4 E26BY E26BY E26BY -- Blue E26B6 E26BB E26BB E26BB -- Amber E26B9 E26BA E26BA E26BA -- Clear E26B0 E26BW E26BW E26BW -- Red E26B2V1 E26BR1V1 E26BRV1 E26BEV1 E26BX2V1 Green E26B3V1 E26BG1V1 E26BGV1 E26BUV1 E26BX3V1 Yellow E26B4V1 E26BY1V1 E26BYV1 E26BVV1 E26BX4V1 Blue E26B6V1 E26BB1V1 E26BBV1 E26BKV1 E26BX6V1 Amber E26B9V1 E26BA1V1 E26BAV1 E26BZV1 E26BX9V1 Clear E26B0V1 E26BW1V1 E26BWV1 E26BMV1 E26BX0V1 Red E26B2V2 E26BR1V2 E26BRV2 E26BEV2 E26BX2V2 2 Green E26B3V2 E26BG1V2 E26BGV2 E26BUV2 E26BX3V2 2 Yellow E26B4V2 E26BY1V2 E26BYV2 E26BVV2 E26BX4V2 Blue E26B6V2 E26BB1V2 E26BBV2 E26BKV2 E26BX6V2 Amber E26B9V2 E26BA1V2 E26BAV2 E26BZV2 E26BX9V2 24 Vac/Vdc 2 Clear E26B0V2 E26BW1V2 E26BWV2 E26BMV2 E26BX0V2 Red E26B2V3 E26BR1V3 E26BRV3 E26BEV3 E26BX2V3 Green E26B3V3 E26BG1V3 E26BGV3 E26BUV3 E26BX3V3 Yellow E26B4V3 E26BY1V3 E26BYV3 E26BVV3 E26BX4V3 2 Blue E26B6V3 E26BB1V3 E26BBV3 E26BKV3 E26BX6V3 Amber E26B9V3 E26BA1V3 E26BAV3 E26BZV3 E26BX9V3 2 Clear E26B0V3 E26BW1V3 E26BWV3 E26BMV3 E26BX0V3 Red E26B2V4 E26BR1V4 E26BRV4 E26BEV4 E26BX2V4 2 Green E26B3V4 E26BG1V4 E26BGV4 E26BUV4 E26BX3V4 2 Yellow E26B4V4 E26BY1V4 E26BYV4 E26BVV4 E26BX4V4 Blue E26B6V4 E26BB1V4 E26BBV4 E26BKV4 E26BX6V4 Amber E26B9V4 E26BA1V4 E26BAV4 E26BZV4 E26BX9V4 Clear E26B0V4 E26BW1V4 E26BWV4 E26BMV4 E26BX0V4 Red E26B2V5 -- E26BRV5 E26BEV5 E26BX2V5 Green E26B3V5 -- E26BGV5 E26BUV5 E26BX3V5 2 Yellow E26B4V5 -- E26BYV5 E26BVV5 E26BX4V5 2 Blue E26B6V5 -- E26BBV5 E26BKV5 E26BX6V5 Amber E26B9V5 -- E26BAV5 E26BZV5 E26BX9V5 Clear E26B0V5 -- E26BWV5 E26BMV5 E26BX0V5 2 48 Vac/Vdc 2 120 Vac 2 2 2 240 Vac 2 2 Notes 1 Include lens, diffusers and lamps unless otherwise noted. 2 Incandescent bulbs are AC/DC rated, LEDs are AC rated only. 2 2 2 V7-T2-36 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com Stacklights E26 Series 2.2 LEDs--Cylindrical or Cluster Cylindrical Stacklight LED 2 Cylindrical or Cluster LEDs Cylindrical LED Cluster LED Cluster LED 2 Voltage Color Steady Only Catalog Number Steady Catalog Number Flashing Catalog Number 2 12 Vac/Vdc Red E26S110 E26S15 E26S48 Green E26S114 E26S19 E26S53 2 Yellow E26S112 E26S23 E26S58 Blue E26S115 E26S27 E26S63 White E26S116 E26S71 E26S75 Amber E26S111 E26S79 E26S84 Red E26S117 E26S16 E26S49 Green E26S121 E26S20 E26S54 Yellow E26S119 E26S24 E26S59 Blue E26S122 E26S28 E26S64 White E26S123 E26S72 E26S76 Cluster LED 24 Vac/Vdc 48 Vac/Vdc 120 Vac/Vdc 240 Vac/Vdc Amber E26S118 E26S80 E26S85 Red E26S124 E26S17 E26S50 Green E26S128 E26S21 E26S55 Yellow E26S126 E26S25 E26S60 Blue E26S129 E26S29 E26S65 White E26S130 E26S73 E26S77 Amber E26S125 E26S81 E26S86 Red E26S138 E26S18 E26S51 Green E26S142 E26S22 E26S56 Yellow E26S140 E26S26 E26S61 Blue E26S143 E26S30 E26S66 White -- E26S74 E26S78 Amber E26S139 E26S82 E26S87 Red -- E26S44 E26S52 Green -- E26S45 E26S57 Yellow -- E26S46 E26S62 Blue -- E26S47 E26S67 White -- E26S101 E26S102 Amber -- E26S83 E26S88 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com V7-T2-37 2.2 2 2 Stacklights E26 Series Mounting Bases Components Standard Base Flashing Base 2 2 C 2 or 4 2 3 or 2 2 2 1 2 or 7 8 1 or - C Factory Wiring or Field Wiring - C 1 2 3 4 5 1 2 3 4 5 6 Flashing Circuit 8 External Switching Devices 7 Description Steady Circuit 9 10 Flashing Orange Module Wire Catalog Number 12 Vac/Vdc to 240 Vac/Vdc E26BL 12 Vdc E26BFV1 24 Vac/Vdc E26BFV2 2 48 Vac/Vdc E26BFV3 120 Vac/Vdc E26BFV4 2 240 Vac/Vdc E26BFV5 Voltage Catalog Number 2 Flashing Base For use with steady incandescent or steady/flashing LED Enables configuration of incandescent light modules for steady or flashing operation 2 2 Flasher Max. Allowable No. of Light Modules 12 Vdc 2 24 Vac/Vdc 4 48 Vac/Vdc 6 120 Vac/Vdc 6 240 Vac/Vdc 6 Flasher Base Voltage 6 Supply 2 Orange Flasher Wire External Switching Devices Supply Voltage 2 9 10 2 2 Standard Base 2 1 2 3 4 5 6 2 2 2 C 1 2 3 2 2 1 2 or 5 1 2 3 4 5 6 2 4 or 6 or 5 2 2 1 2 2 or 6 Mounting Bases and Hubs Description Standard Three-Hole Mounting Base Mounting Base Standard three-hole mounting base -- E26S108 Standard Four-Hole Mounting Base Standard four-hole mounting base -- E26S109 Myers Type Hub Myers Type Hub -- E26S104 2 2 2 2 2 3/4 in NPT threaded hub 2 2 Notes 1 Audible alarm units must be wired via the steady circuit on flashing base units. 2 Audible alarm units can be wired in positions as shown but only one unit is permitted on each stack and unit must occupy the last or top mounting position. 2 2 V7-T2-38 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com Stacklights E26 Series 2.2 Alarm Units and Extension Tubes Components 2 Audible Alarm Units-NEMA Type 1 (IP20) E26B_ Description 2 1 Voltage Catalog Number 12 Vac/Vdc E26BQV1 12.6 mA 24 Vac/Vdc E26BQV2 9.4 mA 48 Vac/Vdc E26BQV3 11.5 mA 120 Vac/Vdc E26BQV4 5.1 mA 240 Vac/Vdc E26BQV5 2 4.5 mA 12 Vac/Vdc E26BNV1 2 12.6 mA 24 Vac/Vdc E26BNV2 9.4 mA 48 Vac/Vdc E26BNV3 11.5 mA 120 Vac/Vdc E26BNV4 5.1 mA 240 Vac/Vdc E26BNV5 12 Vac/Vdc E26BPV1 12.6 mA 24 Vac/Vdc E26BPV2 9.4 mA 48 Vac/Vdc E26BPV3 11.5 mA 120 Vac/Vdc E26BPV4 5.1 mA 240 Vac/Vdc E26BPV5 2 Mono-Tonal 4.5 mA 2 2 Bi-Tonal 2 2 2 Intermittent 4.5 mA 2 2 2 2 Extension Tubes Voltage Catalog Number 2 0.79 in (20 mm) extension -- E26BHM 2 6.30 in (160 mm) extension -- E26BJM 14.17 in (360 mm) extension -- E26BKM 29.92 in (760 mm) extension -- E26BMM 0.79 in (20 mm) extension -- E26BHU 6.30 in (160 mm) extension -- E26BJU 14.17 in (360 mm) extension -- E26BKU 29.92 in (760 mm) extension -- E26BMU Right angle extension tube -- E26BRU Description Extension Tube A Extension Tube A E26BRU Extension "A" 2 2 2 Extension "A" 3 2 2 2 2 2 2 Notes 1 Volume adjustment range: 64 dB to 90 dB typical current draw (mA). 2 For use with standard mounting base or 3/4 in NPT threaded hub--gray aluminum. 3 For use with standard mounting base or 3/4 in NPT threaded hub--black aluminum. 2 2 2 2 2 2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com V7-T2-39 2.2 Stacklights E26 Series 2 Replacement Parts 2 Stacklight Replacement Parts 2 Description Notes Replacement cover Normally included with stacklight base 1 E26S68 Replacement lens O-ring Normally included with light modules 2 E26S106 1 Replacement lenses Clear 3 E26S38 2 2 Typical Stacklight Assemblies Number in Diagram Catalog Number 2 Red E26S39 Green E26S40 2 Yellow E26S41 Blue E26S42 2 2 2 Amber Replacement Xenon strobe dual high (does not include lenses) 2 2 Replacement diffusers E26S34 48 Vac/Vdc E26S35 120 Vac E26S36 2 2 12V Lens 3 4 Light Diffuser E26S37 4 Clear -- normally supplied with LED light modules Replacement lamps 2 2 O-Ring E26S33 24 Vac/Vdc White -- normally supplied with incandescent light modules Alarm E26S43 4 240 Vac 2 2 12 Vac/Vdc 1 Cover Lamp 5 E26S31 Terminal Board E26S32 5 E26S8 24V E26S9 48V E26S10 120V E26S11 240V E26S12 2 Replacement extension tube O-rings Normally included with extension tubes 6 E26S107 2 Replacement mounting gasket 4 Normally included with stacklight base 7 E26S105 2 Lamp removal tool For E26 and E22 incandescent lamps O-Ring 2 3 E22BA3 Set Screw Recommended Tightening Torque Is 7 in-lb (0.79 Nm) 7 Mounting Gasket Stacklight Base O-Rings 6 Extension Tube 2 2 Mounting Base 2 Typical Stacklight Assembly (Exploded View) 2 2 2 Panel 2 Myers Type ST-2 or ST-2CP Hub 2 2 2 2 Alternate Conduit Hub Notes 1 Sold in packages of 5 pieces. 2 For replacement LEDs, see table on Page V7-T2-37. 3 Sold in packages of 10 pieces. 4 Mounting gaskets have two sets of mounting holes--one set with center-to-center spacing of 1.75 in (44.5 mm) and another set with center-to-center spacing of 1.65 in (42 mm). V7-T2-40 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com Stacklights E26 Series 2.2 Technical Data and Specifications 2 General Specifications Description Specification 2 11 ms, 15g 2 Mechanical Ratings Shock (IEC 68-2-27) 2 Vibration (IEC 68-2-6) 10 sweeps 10-150 Hz, 2g Bump (IEC 68-2-29) 1000 pulses, 6 ms, 15g 2 Operating Maximum 104F (40C) at 95% RH, Temperature -4 to 140F (-20 to 60C) 2 Storage Temperature -40 to 176F (-40 to 80C) 2 Cover Polycarbonate Lenses Polycarbonate 2 Stacklight base Nylon Extension tubes Aluminum Mounting base Zinc die cast 2 Single conductor 14-30 AWG (2.5-0.05 mm2) 2 Two conductors (same size)) 18-26 AWG (0.75-0.14 mm2) Do not mix solid and stranded wire in the same terminal 2 Recommended tightening torque 4.4-5.3 lb-in (0.5-0.6 Nm) 2 Insulation voltage (Ui) 690V 2 Operational voltage (Ue) 250V Impulse withstand voltage (Uimp) 1.5 kV 2 Incandescent lamp type BA15d 2 Maximum lamp wattage 6W 2 Incandescent 7,000 to 12,000 hrs. (based on voltage) 2 Xenon flasher 20,000 hrs. LED 60,000 to 100,000 hrs. (based on colors) Climate Conditions Materials 2 Terminals Electrical Ratings Bulb Specifications Bulbs--average life 2 2 LED/Incandescent Comparison Incandescent lamps Average operating life of 7,000 hours Each lamp can be used with any color lens Low cost results in short term savings LED lamps Average operating life of 60,000 to 100,000 hours Low power consumption Extended life results in long-term savings 2 2 2 2 2 2 2 2 2 2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com V7-T2-41 2.2 2 Stacklights E26 Series Ratings 2 Published theoretical lamp lives are based on ideal laboratory conditions and should be used for comparison only. Actual life may be shorter due to various application conditions. 2 Stacklight Incandescent Application Data 2 Type of Light Lamp Used Approximate Current, mA per Light Theoretical Lamp Life, Hours as Applied 2 12V BA15d 417 7,000 24V BA15d 208 7,000 48V BA15d 104 7,000 110-140V BA15d 36-50 7,000 220-260V BA15d 23-27 12,000 2 2 2 Xenon Flasher Application Data 2 Type of Light 2 12V 2 24V 2 48V Lamp Used Approximate Current, mA per Light LED Application Data Type of Light Color Cluster LED Approximate Current, mA at Rated Volts Cylindrical LED Approximate Current, mA at Rated Volts Theoretical Lamp Life, Hours as Applied Continuous/Flashing Stacklight LED 12 Vac/Vdc Theoretical Lamp Life, Hours as Applied 24 Vac/Vdc Red 92 92 100,000 Amber 92 92 100,000 Yellow 92 92 100,000 Green 60 60 80,000 Blue 60 60 60,000 White 60 60 60,000 Red 47 47 100,000 100,000 DC 460 mA 20,000 AC 780 mA 20,000 Amber 47 47 20,000 Yellow 47 47 100,000 59 59 80,000 60,000 DC 190 mA AC 320 mA 20,000 Green DC 100 mA 20,000 Blue 59 59 AC 150 mA 20,000 White 59 59 60,000 Red 25 25 100,000 Amber 25 25 100,000 Yellow 25 25 100,000 Green 18 18 80,000 Blue 31 31 60,000 White 31 31 60,000 Red 25 25 100,000 Amber 25 25 100,000 Yellow 25 25 100,000 Green 18 18 80,000 Blue 17 17 60,000 White 17 17 60,000 Red 24 24 100,000 2 Amber 24 24 100,000 Yellow 24 24 100,000 2 Green 17 17 80,000 Blue 16 16 60,000 White 16 16 60,000 2 2 1 20,000 20,000 120V AC 60 mA 240V AC 30 mA 1 48 Vac/Vdc 2 2 60 Vac/Vdc 2 2 2 2 120 Vac/Vdc 2 Note 1 Represents average current draw, 1.6A peak for 120V and 0.8A peak at 240V. 2 2 2 2 2 2 2 V7-T2-42 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com Stacklights E26 Series 2.2 Mounting Instructions Stacklight bases may be mounted without the use of an extension tube or mounting base. If additional height is required, choose Base Mounting Customer Supplied 0.8-30 in (20-760 mm) extension tubes that fit between the mounting base and stacklight base. The extension tubes are threaded with 3/4 in NPT threads, allowing for direct connection to conduit fittings or threaded holes without the use of a mounting base. Utilizing Extension Tube and Mounting Base Utilizing Extension Tube and 3/4 In (19.1 mm) Conduit Hub Set Screw Recommended Tightening Torque Is 7 in-lb (0.79 Nm) Set Screw Recommended Tightening Torque Is 7 in-lb (0.79 Nm) Stacklight Base Stacklight Base Mounting Gasket Panel 2 2 2 2 2 2 2 Stacklight Base O-Rings O-Rings Extension Tube Extension Tube Mounting Base Myers Type ST-2 or ST-2CP Hub Mounting Gasket Customer Supplied 2 2 2 2 2 2 2 Panel 2 Panel 2 2 (Use Rubber-Jawed Pliers for Installation to Avoid Scratching the Black Anodized Coating) 2 2 Mounting Dimensions Approximate Dimensions in Inches (mm) Base Mounting 0.18 (4.6) Dia. or #8-32 Thread or (M4 x 0.7) 2 Three-Hole Mounting for E26S108 Four-Hole Mounting for E26S109 0.87 (22.1) Dia. 0.87 (22.1) Dia. 2 2 1.06 Dia. (27) 2.12 (53.8) Dia. 1.92 (48.8) Dia. 0.87 Dia. (22.1) Conduit Hub for E26S104-- 3/4 In (19.1 mm) 2 2 2 1.75 (44.5) or 1.65 (42.0) a 90 120 0.18 (4.6) Dia. or #8-32 Thread or (M4 x 0.7) 2 0.20 (5.08) Dia. or #10-32 Thread or (M5 x 0.7) 2 2 Note 1 Stacklight base and gasket are supplied as standard with two sets of base mount holes. One set with center-to-center spacing of 1.75 in (44.5 mm) and another set with center-to-center spacing of 1.65 in (42 mm). 2 2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com V7-T2-43 2.2 2 Stacklights E26 Series Dimensions Approximate Dimensions in Inches (mm) 2 2 Standard and Flashing Bases 1 2 2 2 1.75 (44) 2 2 2 2 Assembled Extension Tubes 2.32 (59) A Alarm Units 2.56 (65) 2 0.59 (15) 2 1.69 (42.9) 2 2 Tube Extension Height A 0.79 (20) 1.77 (45) 6.30 (160) 7.28 (185) 14.17 (360) 15.16 (385) 29.92 (760) 30.91 (785) Right Angle Extension Tubes 2 2 2.00 (50.8) 2 2 2 2 2.50 (63.5) Notes 1 Bases also suitable for mounting with extension tubes listed on Page V7-T2-39. 2 Mounting gasket and cover are supplied as standard with stacklight bases. 2 2 2 2 2 2 2 2 2 2 2 V7-T2-44 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com Stacklights E26 Series 2.2 Approximate Dimensions in Inches (mm) 2 One-Light Unit Stacklight Standard With Alarm 2 2.56 (65) 2.56 (65) 2.56 (65) 2 With Xenon Flasher 2 0.59 (15) 0.59 (15) 2.72 (69) 2.24 (57) 2 2.72 (69) Light Unit 2.72 (69) 1.73 (44) Alarm Xenon Light Unit (2 High) Light Unit 2 2 2.72 (69) Base 1.73 (44) 2 Base 1.73 (44) Base 2 2 Two-Light Unit Stacklight Standard With Alarm 2.56 (65) 2.56 (65) Light Unit 2.24 (57) 2 Xenon Light Unit (2 High) Light Unit Light Unit 2 2 2.72 (69) 2.72 (69) 1.73 (44) 2 Alarm 2.72 (69) 2.72 (69) 2.72 (69) 2 2.56 (65) 0.59 (15) 0.59 (15) 2.72 (69) 2 With Xenon Flasher 2 Light Unit Base 1.73 (44) 2.72 (69) Light Unit 1.73 (44) Base 2 2 Base 2 2 2 2 2 2 2 2 2 2 2 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com V7-T2-45 2.2 2 2 2 Three-Light Unit Stacklight Standard 2 2.72 (69) 2 With Alarm 2.56 (65) 2 2 E26 Series Approximate Dimensions in Inches (mm) 0.59 (15) 2 Stacklights 2.56 (65) 2.24 (57) Light Unit 2.72 (69) 2.72 (69) Light Unit 2.72 (69) Light Unit 1.73 (44) Base Alarm 2.72 (69) Light Unit 2.72 (69) 2.72 (69) 1.73 (44) Light Unit Light Modules 2 Standard 2 2 a 2.72 (69) Light Unit 2.72 (69) Light Unit 1.73 (44) Base Light Unit Base 2 2 Xenon Light Unit (2 High) 2.72 (69) 2 2 2.56 (65) 0.59 (15) 2 2 With Xenon Flasher Xenon 2.56 (65) a 0.59 (15) 0.59 (15) 2.72 (69.1) 2.72 (69.1) 2.56 (65) 2 2 2.72 (69.1) 2 2 Note 1 Cover included with stacklight base. 2 2 2 2 2 2 2 2 2 V7-T2-46 Volume 7--Logic Control, Operator Interface and Connectivity Solutions CA08100008E--March 2014 www.eaton.com